• Title/Summary/Keyword: Concrete railway sleeper

Search Result 40, Processing Time 0.052 seconds

Finite Element Analysis of Concrete Railway Sleeper Damaged by Freezing Force of Water Penetrated into the Inserts (고속철도 콘크리트 궤도 매립전 내 침투수의 결빙압에 의한 균열손상해석)

  • Moon, Do-Young;Zi, Goang-Seup;Kim, Jin-Gyun;Jang, Seung-Yup
    • Journal of the Korean Society for Railway
    • /
    • v.14 no.3
    • /
    • pp.240-247
    • /
    • 2011
  • Finite element analysis was undertaken to investigate the effect of freezing force of water unexpectedly penetrated into inserts used in railway sleeper on pullout capacity of anchor bolts for fixing base-plate onto concrete sleeper. Based on the in-situ investigation and measurement of geometry of railway sleeper and rail-fastener, the railway sleeper was modeled by 3D solid elements. Nonlinear and fracture properties for the finite element model were assumed according to CEB-FIP 1990 model code. And the pullout maximum load of anchor bolt obtained from the model developed was compared with experimental pullout maximum load presented by KRRI for verification of the model. Using this model, the effect of position of anchor bolt, amount of fastening force applied to the anchor bolt, and compressive strength of concrete on pull-out capacity of anchor bolts installed in railway sleeper was investigated. As a result, it is found that concrete railway sleepers could be damaged by the pressure due to freezing of water penetrated into inserts. And the pullout capacity of anchor bolt close to center of railway is slightly greater than that of the others.

Application of WAK test to Identify Unstable Concrete Sleeper

  • Ngo, Vu Thanh;Park, Jaehak;Park, Seongbaek;Lim, Yujin
    • International Journal of Railway
    • /
    • v.9 no.2
    • /
    • pp.46-49
    • /
    • 2016
  • In this study a new detection technique based on WAK is introduced that can be used for identifying unstable concrete sleeper installed in ballast by triggering activated wave on the sleeper surface. If a gap exists immediately below the concrete sleeper, static stiffness can be lower than stable case's stiffness. The concrete sleeper is assumed as a single degree of freedom system (SDOF). The static stiffness K can be obtained by iteratively calculated mass (m), stiffness (k) and damping coefficient (c) of SDOF system. Those coefficients are used to specify the ballast condition such as a gap between the sleeper and ballast. Typical test results using a small sleeper model test are summarized and explained for proof of effectiveness of the WAK test for checking unstable condition of the sleeper.

Using the Turnout Reinforced Concrete Sleeper on Slab Track (콘크리트 도상 분기 침목의 R.C 침목화)

  • 이상진;김기훈;신순호;이인세
    • Proceedings of the KSR Conference
    • /
    • 2002.10a
    • /
    • pp.633-641
    • /
    • 2002
  • Wooden-sleeper, which has been adopted as railway turnout in Korea, has created many problems such as short life span and increase of maintenance cost. Especially turnout on Maintenance Free slab track, which has been used in city metro, has been constructed with wooden sleeper buried in concrete roadbed due to complexity of structure. However, such problem as rapid erosion in subground makes it difficult to maintain the sleeper because of frequent replacement required. Therefore, the objective of this paper is to introduce design and construction of reinforced concrete(R.C) sleeper for turnout on the concrete roadbed to facilitate maintainability and economic construction of turnout.

  • PDF

Fibre composite railway sleeper design by using FE approach and optimization techniques

  • Awad, Ziad K.;Yusaf, Talal
    • Structural Engineering and Mechanics
    • /
    • v.41 no.2
    • /
    • pp.231-242
    • /
    • 2012
  • This research work aims to develop an optimal design using Finite Element (FE) and Genetic Algorithm (GA) methods to replace the traditional concrete and timber material by a Synthetic Polyurethane fibre glass composite material in railway sleepers. The conventional timber railway sleeper technology is associated with several technical problems related to its durability and ability to resist cutting and abrading action of the bearing plate. The use of pre-stress concrete sleeper in railway industry has many disadvantages related to the concrete material behaviour to resist dynamic stress that may lead to a significant mechanical damage with feasible fissures and cracks. Scientific researchers have recently developed a new composite material such as Glass Fibre Reinforced Polyurethane (GFRP) foam to replace the conventional one. The mechanical properties of these materials are reliable enough to help solving structural problems such as durability, light weight, long life span (50-60 years), less water absorption, provide electric insulation, excellent resistance of fatigue and ability to recycle. This paper suggests appropriate sleeper design to reduce the volume of the material. The design optimization shows that the sleeper length is more sensitive to the loading type than the other parameters.

Review on the Allowable Sleeper Spacing at a Bridge Expansion Joint (교량 신축부 허용 침목간격 검토)

  • Lee, Ui-Jae;Bae, Sang-Hwan;Lee, Ho-Ryong;Choi, Jin-Yu
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.1248-1253
    • /
    • 2011
  • It is increasing construction of long span railway bridge with concrete track system for speed up of railway and efficient maintenance of track. As the sleeper of the concrete track system layed on a bridge is fixed on deck of the bridge, the displacement of the sleeper and deck is same. Therefore, the spacing between two sleeper installed at the end of the adjacent deck near the expansion joint of bridge becomes vary according to the longitudinal expansion of a deck by temperature change. By the way, if the spacing of sleepers become increase excessively, it causes large bending stress of in a rail, and it can leads failure or reduction of fatigue life of the rail. Further more, the excessive displacement of the rail may induce decrease ride comfort as well as corrugation of rail surface. Therefore, it is required to determine the allowable maximum sleeper spacing to prevent such problems. For the purpose, investigation on the influence factor on sleeper spacing for straight track was carried out. Variation of bending moment in a rail, wheel force, and the ratio of primary and secondary deflection of the rail according to sleeper spacing was investigated, and, as a result, the maximum allowable sleeper spacing at the bridge expansion joint was suggested.

  • PDF

Preliminary Study on Disposal of Waste Wooden Sleeper by Thermal-Extraction (열추출기술을 이용한 폐목침목처리 기초연구)

  • Kwon, Tae-Soon;Lee, Jae-Young;Jung, Woo-Sung
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.2875-2878
    • /
    • 2011
  • The wooden sleeper has been used at the railway track. Recently the concrete sleeper is pushing the wooden sleeper out, but huge amount of waste wooden sleepers are discharged every year. Due to the contaminant of waste wooden sleeper, its disposal is very difficult. Commonly a wood preservative such as creosote is used in the manufacturing process and it becomes major contaminant after use. And the wooden sleeper is contaminated by diesel from locomotives and lubricant oil from the maintenance of railway turnout. Currently the limitary disposal methods can be used because of high toxicity of waste wooden sleeper. Therefore the preliminary study on thermal-extraction of contaminants such as creosote, diesel and lubricant oil from waste wooden sleeper was conducted and the effects of factors were investigated.

  • PDF

Study on the Maximum Expansion Length of a Bridge with Contrete Track (콘크리트궤도 부설교량의 최대 신축장에 관한 연구)

  • Choi, Yu-Bok;Choi, Jin-Yu;Park, Yong-Gul;Joo, Hwan-Joong;Ki, In-Do
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.436-442
    • /
    • 2011
  • It is increasing construction of long span railway bridge with concrete track system for speed up of railway and efficient maintenance of track. As the sleeper of the concrete track system layed on a bridge is fixed on deck of the bridge, the displacement of the sleeper and deck is same. Therefore, the spacing between two sleeper installed at the end of the adjacent deck near the expansion joint of bridge becomes vary according to the longitudinal expansion of a deck by temperature change. By the way, if the spacing of sleepers become increase excessively, it causes large bending stress of in a rail, and it can leads failure or reduction of fatigue life of the rail. And also the excessive displacement of the rail may induce decrease ride comfort. Therefore, in order to prevent such problems, the allowable maximum sleeper spacing at a bridge expansion joint was mutually determined. And, the determination procedure of the maximum bridge expansion length based on the allowable sleeper spacing was suggested.

  • PDF

A Study on Estimation Method of Concrete Sleeper Strength for Sleeper Floating Track using Rebound Hardness Test Method (반발경도법을 이용한 침목플로팅 궤도의 콘크리트 침목 강도추정 기법 연구)

  • Chung, Jee-Seung;Lee, Jeong-Sug;Choi, Jung-Youl
    • The Journal of the Convergence on Culture Technology
    • /
    • v.8 no.3
    • /
    • pp.277-282
    • /
    • 2022
  • The sleeper floating track (STEDEF) in this study was a track type in which a very soft resilience pad was installed under a relatively thin concrete sleeper (RC Block). Therefore it was expected that the resilience pad could affect the estimation results of the concrete strength. In this study, field applicability evaluation was performed to apply the rebound hardness test method, which was a general method for estimating the compressive strength of concrete in civil structures, to concrete sleepers of railway tracks. In order to analyze the strength estimation technique of concrete sleepers reflecting the characteristics of track structures different from those of civil structures, the parameter experiments that could affect the strength estimation results of concrete sleepers in a serviced line were performed. As a result of the study, the appropriate hitting position was suggested considering the shape of the concrete sleeper, and the difference in strength estimation results according to the condition of the concrete sleeper and supporting conditions was derived.

The Effect of Sleeper Space and Support Stiffness in Concrete Track on Vibration of Structure (콘크리트궤도 침목간격과 궤도지지강성이 진동에 미치는 영향)

  • Sung, Deok-Yong;Kim, Sang-Jin;Yang, Tae-Kyoung;Jang, Ki-Sung;Park, Yong-Gul
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.725-732
    • /
    • 2011
  • The vibration resulting from railway operation is transmitted through the tunnel to adjacent buildings and the transmitted vibration radiates structure-borne noise which is causing a lot of public complaints by its negative effects to the buildings near tunnel. This study performed the parametric study about sleeper space and track support stiffness in order to reduce vibration on the concrete track and near structures. In this study, it was compared and performed vibration analysis and field test about these. In addition, as changing the sleeper space and track support stiffness, vibration of the structures was evaluated. Via this study, in terms of reducing the figure of the sleeper space and track support stiffness to the half, as vibrating acceleration transmitted through concrete round is getting reduced, it transmitted through the tunnel was analysed to the same phenomena. In conclusion, suggested track structure into this study, it can be applied to the track structure of existing line, and it is expected to be a new effective anti-vibration method to prevent public complaints.

  • PDF

Damage Cause Analysis of Concrete Sleepers for Sharp Curved Track on Urban Railway Bridge (도시철도 교량상 급곡선 자갈궤도용 콘크리트침목 손상원인 분석)

  • Choi, Jung-Youl;Shin, Tae-Hyoung;Chung, Jee-Seung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.7 no.3
    • /
    • pp.517-522
    • /
    • 2021
  • In this study, the causes of damage to the concrete sleepers in a ballast track with under sleeper pads attached to the base of the sleepers installed in the sharp curved track(R=180m) of the urban railway bridge were analyzed. The damage types of concrete sleepers were investigated, and the correlation with track irregularity was reviewed. Also, stress generated in the concrete sleeper was reviewed through structural analysis. As a result, most of the cracks of the sleepers occurred in the section with severe track irregularity. In addition, as a result of the analysis, the stress generated in the track components and the sleepers was found to be reduce in the fastening system using the 4-anchor.