• Title/Summary/Keyword: Concrete Roof

Search Result 181, Processing Time 0.023 seconds

Development of Impact and Fire Hazard Analysis on the Steel Roof of LNG Storage Tank (LNG 저장탱크 강재지붕의 충격 및 화재에 대한 안전성평가기법 개발)

  • Lee, Seung-Rim;Park, Jang-Sik;Lee, Young-Soon
    • Journal of the Korean Institute of Gas
    • /
    • v.13 no.1
    • /
    • pp.34-39
    • /
    • 2009
  • Traditionally all concrete roof type LNG storage tank have been constructing in Korea regardless of LNG tank types. But a steel roof LNG storage tank has merits relatively in designing larger scale tanks and construction cost so it is on the table to apply. This study was carried for the standardized development of impact and fire hazard analysis on a 200,000$k{\ell}$ steel roof LNG storage tank designed by KOGAS and for getting quantitative safety data on a steel roof LNG storage tank compared with a conventional concrete roof LNG storage tank by evaluating with this method. Hazard analysis on each four impact and fire scenarios were developed and evaluated by using finite element methods.

  • PDF

A Study on the Architectural Characteristics and Facade Construction of the Brick Masonry Auditorium in Daegu During the Modern Age - Focused on the Auditorium of Namsan Primary School - (근대기 대구지역 벽돌조 강당 건물의 건축특성과 파사드 구성에 관한 연구 - 남산초등학교 강당을 중심으로 -)

  • Yoon, Jae-Woong
    • Journal of architectural history
    • /
    • v.19 no.6
    • /
    • pp.121-135
    • /
    • 2010
  • This study was to analyze the architectural characteristics and facade construction of brick masonry auditorium through the Auditorium of Namsan Primary School in 1936. The results of this study were described separately as follows. 1. The auditorium is located away from the school buildings, and its plane is a chamber of rectangle type with an entrance installed on each of the four sides. 2. The external appearance is Renaissance eclectic style, laid red bricks on the lower wall of the window and having a mansard roof. The front and the rear are symmetric with respect to the projected wall at the center. 3. As to the structure of the building, a concrete lower wall was built on the concrete continuous footing, and the brick wall was constructed on the lower wall. The roof is queen post roof truss, and the wall girders were installed on the brick wall. 4. The auditorium has had a number of repairing and maintenance works, which changed the roof and windows outside and the floor, walls, ceiling, etc. inside. 5. The decorative elements of external appearance include lower wall, brick wall, entrances, windows, roof, and dormer windows. The brick wall gives verticality and solidity to the surface of the wall, and the lower wall and wall girders are connected like a cornice of the wall. The surface of the mansard roof and dormer windows express a stable vertically oriented shape.

Condition assessment of fire affected reinforced concrete shear wall building - A case study

  • Mistri, Abhijit;Pa, Robin Davis;Sarkar, Pradip
    • Advances in concrete construction
    • /
    • v.4 no.2
    • /
    • pp.89-105
    • /
    • 2016
  • The post - fire investigation is conducted on a fire-affected reinforced concrete shear wall building to ascertain the level of its strength degradation due to the fire incident. Fire incident took place in a three-storey building made of reinforced concrete shear wall and roof with operating floors made of steel beams and chequered plates. The usage of the building is to handle explosives. Elevated temperature during the fire is estimated to be $350^{\circ}C$ based on visual inspection. Destructive (core extraction) and non-destructive (rebound hammer and ultrasonic pulse velocity) tests are conducted to evaluate the concrete strength. X-ray diffraction (XRD) and Field Emission Scanning Electron Microscopy (FESEM) are used for analyzing micro structural changes of the concrete due to fire. Tests are conducted for concrete walls and roof slab on both burnt and unburnt locations. The analysis of test results reveals no significant degradation of the building after the fire which signifies that the structure can be used with full expectancy of performance for the remaining service life. This document can be used as a reference for future forensic investigations of similar fire affected concrete structures.

Water conservation effect of concave greenroof system and its influential factors (오목형 옥상녹화의 수자원확보효과와 영향인자)

  • Baek, So-Young;Han, Moo-Young
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.29 no.2
    • /
    • pp.165-169
    • /
    • 2015
  • Green roofs are gaining much interest in many cities around the world due to its multi-purpose effects of water conservation, flood mitigation and aesthetic benefits. However it may cause additional water demand to maintain green plants, which may intensify the current and future water shortage problems. While ordinary concrete roofs and normal green roof drains off rain water, concave green roof system can retain rain water because of its water holding capability. In this study, the water conservation effect of concave green roof was compared to normal roof on #35 building in Seoul National University, Seoul, Korea. For seven rainfall events the amount of stored rainwater and runoff were measured and proved water conservation effect of the concave green roof system. The concave green roof system of which area is 140m2 showed effect of water conservation from 1.8ton to 7.2ton and the most influence factors on water conservation in green roof are rainfall and antecedent day. If this concave green roof is applied to many buildings in the cities, it is expected as a way to water conservation through rainfall storage.

Waterproofing and Root Barrier Construction Design for Artificial Green Roof System of Residential Apartment Underground Parking Lots (공동주택 지하주차장 상부 인공지반녹화층 방수 및 방근 설계 방안)

  • Lee, Jung-Hun;Kim, Bum-Soo;Song, Je-Young;Kim, Soo-Yeon;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.05a
    • /
    • pp.337-338
    • /
    • 2018
  • In recent years, residential apartment building parking lots are built in underground spaces, and with conjunction to improve the environment of the urban area, artificial greeen roof systems are installed on the upper slabs. However, early plant growth are resulting in root penetration into concrete cracks and in turn into the waterproofing membranes, leading to degradation and damaging of the waterproofing system and structural durability. This issue highlights a problem of conventional maintenance system of concrete structures, and proposals for amendments follow. In this study, a waterproofing and root barrier construction design for the upper slabs of residential building underground parking lots is proposed, and motioned to be added into future construction specifications.

  • PDF

The Analysis of LNG Storage Tank Steel Roof Behavior by the Change of Design Variables (설계 변수 변화에 따른 LNG 저장탱크 Steel Roof 거동 분석)

  • Kim Y,K.;Kim J.H.;Oh B.T,;Yoon I.S.;Yang Y,M.
    • Journal of the Korean Institute of Gas
    • /
    • v.9 no.1 s.26
    • /
    • pp.33-37
    • /
    • 2005
  • This paper deals with parametric studies for the structural response of LNG Storage Tank steel roof behavior acoording to change in design condition. In the design of steel roof, it may be required to represent a stable behavior under many loading conditions and those of combinations. We fulfill the analysis the steel roof behavior during concret placing and additionally change the design variabls like H beam, pressure and steel roof plate thickness. On the basis of the obtained results from this studies a guideline for a more reasonable design of LNG storage tank steel roof is introduced.

  • PDF

Towards guidelines for design of loose-laid roof pavers for wind uplift

  • Mooneghi, Maryam Asghari;Irwin, Peter;Chowdhury, Arindam Gan
    • Wind and Structures
    • /
    • v.22 no.2
    • /
    • pp.133-160
    • /
    • 2016
  • Hurricanes are among the most costly natural hazards to impact buildings in coastal regions. Building roofs are designed using the wind load provisions of building codes and standards and, in the case of large buildings, wind tunnel tests. Wind permeable roof claddings like roof pavers are not well dealt with in many existing building codes and standards. The objective of this paper is to develop simple guidance in code format for design of loose-laid roof pavers. Large-scale experiments were performed to investigate the wind loading on concrete roof pavers on the flat roof of a low-rise building in Wall of Wind, a large-scale hurricane testing facility at Florida International University. They included wind blow-off tests and pressure measurements on the top and bottom surfaces of pavers. Based on the experimental results simplified guidelines are developed for design of loose-laid roof pavers against wind uplift. The guidelines are formatted so that use can be made of the existing information in codes and standards such as American Society of Civil Engineering (ASCE) 7-10 standard's pressure coefficients for components and cladding. The effects of the pavers' edge-gap to spacer height ratio and parapet height to building height ratio are included in the guidelines as adjustment factors.

A Study on the Performance Appraisal for Copper Sheet as Root Barrier Material Appling to Green Roof System (옥상녹화 및 인공지반녹화용 구리시트 방근재의 성능평가에 관한 연구)

  • Cho, Il-Kyu;Kwon, Shi-Won;Kwak, Kyu-Sung;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2007.04a
    • /
    • pp.5-8
    • /
    • 2007
  • Selection of proper root barrier as destination part of greening is very important in Root penetration resistance plan. To select proper root barrier, it need to understand composition of greening part, size, kind of plant, connection with waterproofing layer. In this point of view, we have establish greening on the roof or concrete structure, not been understand the structural mechanism. It means that we misunderstood about purpose of greening and using it. So, chosen materials and construction method was not proper for greening, it caused water leakage and decrease performance of concrete structure. Therefore, we examine the practical use of copper sheet considering environmental condition for green roof. Watertightness by water of greening part, root penetration resistance test by root penetration, bacteria resistance by must or bacteria in soil, chemical resistance by rain and chemical agent of fertilizer, and load resistance by soil depth, sire of plant. These suggested test methods could be referred as guideline to test in green roof system because of not exist any performance appraisal guideline or standard. Consequently, it should be analysis as technical and institutional subdividing test methods and it need to study constantly as varied angles.

  • PDF

The Study of Roof Design for LNG Storage Tank (LNG저장탱크 Roof 설계에 관한 연구)

  • Kim, Y.K.;Lee, K.;Hong, S.H.;Oh, B.T.
    • Proceedings of the KSME Conference
    • /
    • 2001.11a
    • /
    • pp.448-452
    • /
    • 2001
  • Natural gas became one of the major sources of energy in Korea. As the consumption of natural gas increase, the more capacity of the LNG storage tanks is required. Recently, Korea Gas Corp.(KOGAS) has developed the technology of designing the LNG storage tanks. In this study, some of the finite element analysis has been made for designing of the roof structure of LNG storage tanks. The load case and safety code used in this study were followed by BS7777.

  • PDF