• 제목/요약/키워드: Concrete Filled Tube

검색결과 496건 처리시간 0.023초

Stiffener configurations of beam to concrete-filled tube column connections

  • Dessouki, Abdelrahim K.;Yousef, Ahmed H.;Fawzy, Mona M.
    • Steel and Composite Structures
    • /
    • 제17권1호
    • /
    • pp.83-103
    • /
    • 2014
  • The objective of this research is to study the ultimate moment capacity of the connections between steel I-beams and concrete-filled steel tube columns using different stiffener configurations. The main parameters considered are column cross section shape, square or circular, and filling the column with concrete. This analytical study includes finite element models using ANSYS program taking geometric and material nonlinearities into consideration. These models are verified against the experimental results obtained from previous researches and current design guides. The results show that using proper stiffener configuration affects the stress distribution through the connection and increases the ultimate moment capacity of the connections. Also, circular column is advantageous than the square column for all stiffener configurations and dimensions.

Compressive performance of RAC filled GFRP tube-profile steel composite columns under axial loads

  • Ma, Hui;Bai, Hengyu;Zhao, Yanli;Liu, Yunhe;Zhang, Peng
    • Advances in concrete construction
    • /
    • 제8권4호
    • /
    • pp.335-349
    • /
    • 2019
  • To investigate the axial compressive performance of the recycled aggregate concrete (RAC) filled glass fiber reinforced polymer (GFRP) tube and profile steel composite columns, static loading tests were carried out on 18 specimens under axial loads in this study, including 7 RAC filled GFRP tube columns and 11 RAC filled GFRP tube-profile steel composite columns. The design parameters include recycled coarse aggregate (RCA) replacement percentage, profile steel ratio, slenderness ratio and RAC strength. The failure process, failure modes, axial stress-strain curves, strain development and axial bearing capacity of all specimens were mainly analyzed in detail. The experimental results show that the GFRP tube had strong restraint ability to RAC material and the profile steel could improve the axial compressive performance of the columns. The failure modes of the columns can be summarized as follow: the profile steel in the composite columns yielded first, then the internal RAC material was crushed, and finally the fiberglass of the external GFRP tube was seriously torn, resulting in the final failure of columns. The axial bearing capacity of the columns decreased with the increase of RCA replacement percentage and the maximum decreasing amplitude was 11.10%. In addition, the slenderness ratio had an adverse effect on the axial bearing capacity of the columns. However, the strength of the RAC material could effectively improve the axial bearing capacity of the columns, but their deformability decreased. In addition, the increasing profile steel ratio contributed to the axial compressive capacity of the composite columns. Based on the above analysis, a formula for calculating the bearing capacity of composite columns under axial compression load is proposed, and the adverse effects of slenderness ratio and RCA replacement percentage are considered.

Performance of composite frame consisting of steel beams and concrete filled tubes under fire loading

  • Shariati, Mahdi;Grayeli, Mohammad;Shariati, Ali;Naghipour, Morteza
    • Steel and Composite Structures
    • /
    • 제36권5호
    • /
    • pp.587-602
    • /
    • 2020
  • In recent years, the composite columns have been widely used in the structures. These columns are mainly used to construct the structures with a large span and high floor height. Concrete filled tubes (CFTs) are a type of composite column, which are popular nowadays due to their numerous benefits. The purpose of this study is to investigate such frames at elevated temperatures. The method used in this research is based on section 2.2 of Eurocode 4. First, for the verification purpose, a comparison was made between the experimental results and the numerical model of the concrete filled tube. Then a composite frame was analyzed under fire temperature with different parameters. The results showed that the failure time decreased with increasing the friction of different models. Moreover, investigation of the concrete moisture content revealed that an increase in the concrete moisture content from 3% to 10% led to extended failure time for different models. For instance, in the second frame model, the failure time has increased up to 8%.

개선된 부착슬립 모델을 적용한 부분 CFST 기둥의 수치해석 (Numerical Approach for a Partial CFST Column using an Improved Bond-Slip Model)

  • 황주영;곽효경
    • 한국전산구조공학회논문집
    • /
    • 제33권3호
    • /
    • pp.153-158
    • /
    • 2020
  • 본 논문에서는 부분 CFST (concrete-filled steel tube) 기둥에 대한 수치해석적 저항력 평가 방법에 대해 소개하고 있다. 기존 RC(reinforced concrete) 기둥에서 소성힌지가 발생할 것으로 예상되는 부분을 강관으로 보강함으로써 완전 CFST 기둥보다는 적은 재료를 사용하여 비슷한 휨 모멘트 저항력을 가지는 부분 CFST 기둥의 디자인 컨셉을 제시하였다. 부분 CFST 기둥에서 외부 강관과 내부 콘크리트 사이의 계면에서 거동을 수치해석적으로 모사하기 위해 개선된 부착슬립모델을 적용한 유한요소모델을 구축하고, 이중곡률 휨-압축시험결과와 비교를 통해 타당성을 검증하였다. 검증된 수치모델을 바탕으로 매개변수 연구를 통해서 P-M 상관도를 그려 단면 조건에 따른 최대 저항력을 평가하였다. 또한, 강관 두께별로 필요 보강길이를 산출하고, 보강 조건에 따른 부분 CFST 기둥에서의 파괴메커니즘을 분석하였다.

콘크리트 강도 및 강관 폭두께비에 따른 각형 CFT 단주의 내력평가 (Strength Evaluation of Rectangular CFT Stub Columns varing with Concrete Strength and Width-to-Thickness Ratio of Steel Tubes)

  • 심종석;한덕전
    • 한국디지털건축인테리어학회논문집
    • /
    • 제11권2호
    • /
    • pp.31-39
    • /
    • 2011
  • Concrete-filled steel tube(CFT) columns have become popular for building construction due to not only composite effect of steel tube and infilled concrete, but also more economical. The purpose of this paper is to propose the applicable boundary formula of width-to-thickness ratio for rectangular steel tube as using CFT column. A parametric study was performed taking width-to-thickness ratio of rectangular steel tube and compressive strength of concrete as the main parameter. The strength of concrete are selected to 30, 60, 90MPa. The non-linear analysis was adopted in order to take into account the effect of concrete strength. Finally, from the test and analysis results, the effect of increasing strength according to concrete strength and width-to-thickness of steel tube and plastic behavior of specimens were verified distinctly.

대구경 콘크리트 충전형 합성기둥의 전단 설계식 분석 (Investigation of Shear Design Expressions of Large-Diameter Concrete-Filled Steel Tubes(CFT))

  • 정은비;염희진;유정한
    • 한국강구조학회 논문집
    • /
    • 제27권4호
    • /
    • pp.399-410
    • /
    • 2015
  • 콘크리트 충전형 합성기둥(Concrete filled steel tube, CFT)은 철근콘크리트, 강구조보다 뛰어난 변형 능력과 강도 갖고 있다. CFT 현장타설말뚝은 지진하중, 토양액상화 등에 의해 큰 국부전단력을 경험하게 되며 이를 방지하기 위해 큰 직경으로 설계되어 진다. 그러나 현행 기준의 전단 설계식은 CFT의 구속효과를 고려하지 못하고 있으며, 상당히 보수적인 설계식을 제시하고 있다. 전단 설계식의 개선을 위한 선행 전단 실험연구가 거의 없으며 그조차 소구경의 실험연구로만 존재한다. 이 연구는 대구경 콘크리트 충전형 합성기둥의 개선된 전단 설계식을 제안하기 위한 기초연구로써, 원형 CFT 기둥 전단의 선행 실험연구와 현행 설계기준 비교분석을 실행하였다.

Behavior of Hybrid Double Skin Concrete Filled Circular Steel Tube Columns

  • Kim, Jin-Kook;Kwak, Hyo-Gyoung;Kwak, Ji-Hyun
    • Steel and Composite Structures
    • /
    • 제14권2호
    • /
    • pp.191-204
    • /
    • 2013
  • A hybrid double skin concrete filled (HDSCF) circular steel tube column is proposed in this study. The yield strength of the outer steel tube is larger than 690MPa and the inner tube has less strength. In order to achieve efficiency with the high strength outer tube, a feasibility study on reducing the thickness of the tube below the specified design codes for CFTs was conducted based on an experimental approach. The experiment also took variables such as thickness of the inner tube, hollow ratio, and strength of concrete into consideration to investigate the behavior of the HDSCF column. In order to estimate the applicability of design equations for CFTs to the HDSCF column, test results from CFT and HDSCF columns with design codes were compared. It was found that the axial compressive performance of the proposed HDSCF column is equivalent to that of the conventional CFT member irrespective of design variables. Furthermore, the design equation for a circular CFT given by EC4 is applicable to estimate the ultimate strength of the HDSCF circular steel tube column.

다이어프램 선 조립 ㄷ형태 기둥을 이용한 CFT내진보강공법 (CFT seismic reinforcement method using diaphragm pre-assembled ㄷ-shaped column)

  • 우종열;신승훈
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2022년도 가을 학술논문 발표대회
    • /
    • pp.151-152
    • /
    • 2022
  • When reinforcing an existing building with the Concrete Filled Tube(CFT) structure, it is impossible to form a diaphragm inside with the existing method. Therefore, in this study, a construction method was proposed so that the internal diaphragm could be welded on four sides by using a slot to transmit force.

  • PDF

Experiment of Compressive Strength Enhancement of Circular Concrete Column Confined by Carbon Tubes

  • Hong Won-Kee;Kim Hee-Cheul;Yoon Suk-Han
    • KCI Concrete Journal
    • /
    • 제14권4호
    • /
    • pp.139-144
    • /
    • 2002
  • Concrete filled FRP tube has lately attracted attention as the member that can substitute the conventional reinforced concrete. Glass fiber and carbon fiber are some of available materials for FRP tube. Carbon tube is filament wound with specified winding angle to meet the appropriate capacity demands. Confinement effect of carbon tube is varied according to winding angle. In this study, a total 4 of large scale circular specimens of 30cm diameter and 60cm height is tested. To estimate the effect of winding angle and thickness of carbon tube on the increased confined compressive strength, the test tube are wound with $\pm45^{\circ}\;and\;\pm30^{\circ}$ with two types of thickness, 2mm and 3mm, respectively. It is shown that effectively increased confined strength and ductility are observed from the specimens with $\pm45^{\circ}$ winding angle than $\pm30^{\circ}$ winding angle. Increasing thickness is not as effective as adjusting winding angle for the confinement of concrete core.

  • PDF

연성도 및 에너지 소산능력 비교에 따른 콘크리트충전 탄소섬유튜브 기둥의 성능 (Capacity of Concrete Filled Carbon Tube Columns Based on the Comparison of Ductility and Energy Dissipation Capacity)

  • 이경훈;홍원기;이영학;김희철
    • 한국지진공학회논문집
    • /
    • 제11권1호
    • /
    • pp.29-35
    • /
    • 2007
  • 본 연구에서는 반복 횡하중을 받는 콘크리트충전 탄소섬유튜브기둥의 휨성능 평가실험을 수행하였다. 시험체의 단면형상은 각형과 원형이며 탄소삼유튜브의 두께 및 와인딩각도(winding angle)를 실험변수로 채택하였다. 모든 시험체는 건물의 한 층 높이와 유사한 높이를 갖는 full scale 크기로 제작되었으며 3대의 가력기(actuator)를 동시에 가동시켜 축하중과 횡하중을 가력하였다. 실험결과를 분석하여 기둥의 휨강도, 변형능력 및 에너지소산능력을 평가하였으며, 횡하중에 대한 기둥의 연성거동 또한 평가되었다.