• 제목/요약/키워드: Concrete Area Ratio

검색결과 312건 처리시간 0.03초

폐콘크리트 분말의 분말도가 모르타르의 품질특성에 미치는 영향 (The Effect on the Quality Properties of Mortar by Surface Area of Waste Concrete Powder)

  • 최연왕;문대중;김성수;정재권;김용직
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 봄학술 발표회 논문집(II)
    • /
    • pp.365-368
    • /
    • 2005
  • Waste concrete powder(WCP) has been estimated with a great value-added material as by-product of waste concrete manufactured to fine and coarse aggregate for concrete, because it is able to utilized for cement clinker and concrete admixture. Experimental tests were performed as such plastic viscosity of paste, flow and compressive strength of mortar by surface area of WCP. As a result, flow and 28days compressive strength of mortar was decreased according to increased replacement ratio of WCP as compared to control mortar. Also, plastic viscosity of paste used WCP1 and WCP2 was decreased with increasing replacement ratio, but WCP3 was increased with increasing replacement ratio.

  • PDF

프리캐스트 콘크리트 세그먼트의 구속효과를 고려한 비선형 해석 (Nonlinear Analysis considered Confinement Effect of Precast Concrete Segment)

  • 이헌민;김태훈;박재근;김영진;신현목
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 춘계 학술발표회 제20권1호
    • /
    • pp.305-308
    • /
    • 2008
  • 이 연구에서는 최근 연구가 활발히 진행되고 있는 조립식 프리캐스트 세그먼트 콘크리트 교각공법에서 사용되어지는 기성 콘크리트 세그먼트의 횡 방향 구속철근에 의한 구속효과에 대한 연구를 수행하였다. 일반적으로 횡방향 구속철근에 의한 콘크리트의 구속효과는 구속효과계수에 의하여 결정되며 구속효과계수는 유효 구속 콘크리트 단면적과 구속 콘크리트 단면적의 비로서 결정된다. 유효 구속 콘크리트 단면적은 횡 방향 구속철근간의 간격에서 발생하는 Arching action에 의하여 결정되어지며 구속 콘크리트 단면적은 교각의 주철근비에 의하여 결정되어진다. 그러나 프리캐스트 콘크리트 세그먼트의 경우 세그먼트 상, 하부에 존재하는 피복을 고려하여야 한다. 즉 최상단 및 최하단에 배근되는 횡방향 구속철근에서 상, 하부 콘크리트 표면의 피복까지의 구속효과를 고려하여야 한다. 이 연구에서는 이에 대한 고려 방법을 제안하였다. 제안한 프리케스트 구속효과를 고려한 콘크리트 재료 모델을 RCAHEST에 적용하여 그 타당성을 검증하였다.

  • PDF

프리캐스트 콘크리트와 현장타설 콘크리트 복합 보의 전단강도 (Shear Strength of Hybrid Beams Combining Precast Concrete and Cast-In-Place Concrete)

  • 김철구;박홍근;홍건호;강수민
    • 콘크리트학회논문집
    • /
    • 제25권2호
    • /
    • pp.175-185
    • /
    • 2013
  • 최근 다른 압축강도로 타설된 프리캐스트 콘크리트(PC)와 현장타설 콘크리트(CIP)의 복합 부재의 사용이 증가하고 있지만 현행 기준에는 서로 다른 강도로 복합화된 부재의 전단강도에 대한 설계 기준이 없다. 그래서 이번 연구에서 서로 다른 압축강도(24 MPa, 60 MPa)로 분리 타설된 보의 전단강도 실험을 수행하여 복합 부재의 전단강도에 대해 알아보았다. 변수로는 단면형상, 휨철근비, 그리고 전단경간비를 고려하였다. 실험 결과 값과 현행 전단 기준식과 단면적비로 계산한 유효 콘크리트 강도를 이용한 예측 값을 비교하였다. 실험 결과를 분석해보면 철근비가 낮고 압축대에 60 MPa가 사용된 실험체들에 대해 설계 기준식을 과대평가하였다. 실험 결과를 기준으로 PC와 CIP 복합부재의 전단설계 기준을 제안하였다.

해양환경하에 방치한 콘크리트중의 철근의 부식 추정에 대한 연구 (A Study on the Estimation of Steel Corrosion in Concrete Exposed under the Environment of Seawater)

  • 문한영;김성수;류재석
    • 콘크리트학회지
    • /
    • 제6권2호
    • /
    • pp.129-137
    • /
    • 1994
  • 해양환경하에 있는 콘크리트 구조물의 열화를 알아보고 철근의 부식 정도를 추정하기 위한 연구내용으로서 콘크리트 중에 철근을 묻은 공시체를 제작하여 간만의 차가 있는 해변에 1년 동안 노출시킨 상태로 시험을 실시 하여 콘크리트 중의 가용성 염분량, 철근의 자연전위값 및 철근의 부식정도에 대하여 고찰하였다. 본 연구 결과 콘크리트 중의 가용성 염분량은 물-시멘트비가 낮을수록, 혼화재를 혼입할 경우 적게 나타났으며 가용성 염분량이 클수록 철근의 부식이 크게 나타났다. 철근 부식의 정도가 심할수록 자연전위값이 감소하였으며 자연전위와 부식면적율과는 상관관계가 있음을 알 수 있었다.

콘크리트 밀실화에 의한 염해대책 및 방청효과에 관한 실험적 연구 (제2보, 철근의 부식 현황을 중심으로) (An Experimental Study on the Effect of Corrosion Protection by Tighting Concrete Used Fly-ash and Silica Fume (Part2, In the case of Steel Bar s Corrosion))

  • 이상수;김진만;남상일;김문한;김무한
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1994년도 봄 학술발표회 논문집
    • /
    • pp.148-151
    • /
    • 1994
  • Up to now, sea sand without complete removal of salt is being used in the construction works because there is little satisfactory counterplan for the substitute aggregate. In the case that such sea sand is used in the reinforced concrete, the residual salt gives rise to deterioration phenmenon and iron corrosion, reducing durability of the ferro-concrete structures. The paper, an experimental study on the effect of corrosion protection by tighting concrete used SF and FA, is to investigate general steel bar's corrosion and to develop concrete using sea sand economically after it is analyzed and examinated ratio of the corrosion area affected by the autoclave cycle. As a test results, as for corrosion area ratio, it is very effective to use admixrutes such as SF and FA which decrease corrosion area remarkably with increasing the amounts of admixtures. Accordingly the use of admixtures is advantageous for tightening concrete and has an effect of salt damage prevention and rust protection in concrete used sea sand.

  • PDF

부순모래를 사용한 초류동 콘크리트의 배합특성 (The Properties of the Super Flowing Concrete using manufactured sand)

  • 권영호;이상수;안재현;박칠림
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1997년도 가을 학술발표회 논문집
    • /
    • pp.83-88
    • /
    • 1997
  • In this paper, we described the basic elements (relative flowing area ratio and funeling velocity ratio in mortar, flowability and self-compactibility in concrete, and etc.) required for the maximum mix design of the super flowing concrete (SFC) using manufactured sand. Also, manufactured sand and fly ash were used for investigating characteristics of SFC through various experiments (replacement ratio of manufactured sand, optimum mix condition) before producing the concrete in batch plant. As the result of this project, the SFC using manufactured sand up to 50% showed high flowability and self-compactibility in fresh concrete. Furthermore, its compressive strength is higher than normal concrete without manufactured sand. From now on, this study may suggest how to apply manufactured sand in the SFC.

  • PDF

고로슬래그 미분말을 사용한 콘크리트의 방청성능에 관한 연구 (A Study on the Rust-protection Performance of Concrete using Ground Granulated Blast-furnace Slag)

  • 박상준;김동석;원철;이상수;김영진
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 가을 학술발표회 논문집
    • /
    • pp.529-532
    • /
    • 2001
  • In this paper, rust-protection performance of concrete using ground granulated blast-furnace slag are discussed. 4 kinds of W/B in combination with 3 kinds of replacement ratio of ground granulated blast-furnace slag and 2 kinds of chloride ion contents of are selected as experimental parameters. According to the experimental results, as the replacement ratio of ground granulated blast-furnace slag is increased, the corrosion area of steel bar tends to be decreased. However, as the autoclave cycle and chloride ion contents are increased, the corrosion area of steel bar is increased. In conclusion, when the replacement ratio of ground granulated blast-furnace slag is 50%, the strength and rust-protection performance appear to be most excellent.

  • PDF

표면피복종류에 따른 복합열화환경하의 철근콘크리트 부식특성에 관한 실험적 연구 (An experimental study on corrosion properties of reinforcing steel under environment of complex deterioration)

  • 조봉석;김영덕;윤종기;김재환;김용로;김무한
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 가을 학술발표회 논문집
    • /
    • pp.86-89
    • /
    • 2003
  • It is recognized that reinforcement corrosion is the main distress behind the present concern regarding concrete durability. In this study, to confirm corrosion of reinforced concrete affected by thickness of cover, kinds of surface coating, measured electric potential, ratio of corrosion area, weight reduction, corrosion velocity of steel bar under environment of complex deterioration. The results showed that an increase in age also increases corrosion of steel bar. Ratio of corrosion area is largely related to ratio of weight reduction. as well, corrosion of steel bar by thickness of cover is superior to l0mm thick than 20mm thick. It showed that an increase in thickness of cover prevent steel bar from deteriorating. The results of this study showed that corrosion velocity was affected by thickness of cover, kinds of surface coating. data on the development of corrosion velocity made with none, organic B, organic A, inorganic B, and inorganic A is shown.

  • PDF

압축력비와 수직철근비에 따른 RC T형 벽체의 구조성능 평가에 관한 해석적 연구 (Evaluation of Structural Performance of RC T-shaped Walls with Different ratios of axial load and vertical reinforcement)

  • 하상수;최창식;이리형
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.403-408
    • /
    • 2003
  • The objective of this study is to understand the variables affected the confinement for the transverse reinforcement of the reinforced concrete structural walls with the T-shaped cross section subjected to cyclic lateral loads. The structural performance of T-shaped walls was advanced by the transverse reinforcement which restrained the concrete subjected to compressive stress. If the arrangement of transverse reinforcement was not suitable for the confinement, T-shaped walls happened the brittle failure by web crushing or bucking of vertical reinforcement at the compression zone. It is necessary to confine transverse reinforcement in order to prevent the these failure. But the location of neutral axis and the magnitude of ultimate strain vary according to the section shape, a ratio of axial load, a ratio of wall cross sectional area to the floor-plan area, an aspect ratio and the reinforcement ratio. Therefore, the objective of this research is to grasp the location of neutral axis and the range which needs for the confinement of transverse reinforcement through the results of the sectional analysis which varies the ratio of axial load and the ratio of vertical reinforcement.

  • PDF

중심 축력을 받는 고강도 철근 콘크리트 기둥의 내력 및 연성에 관한 연구 (Strength and Ductility of High-Strength Reinforced Concrete Columns under Uniaxial Loads)

  • 이강건;이재연;김성수;이리형
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1990년도 가을 학술발표회 논문집
    • /
    • pp.57-62
    • /
    • 1990
  • This paper is to study the effect of rectilinear confinement in high-strength concrete subjected to a monotonically increasing compressive axial loads. To investigate behavior of columns rectilinearly confined with lateral ties and longitudinal rebars, twelve specimens including two plain concrete specimens were tested. The main variables in this study are volumetric ratio of lateral ties, cistribution of lateral ties, yield strength of logitudinal steel, ratio of area of longitudinal steel to the area of cross section. The test results were not only compared with an empirical model for the stress-strain curve of rectilinearly confined high-strength concrete but also the existing model. The empirical model used calculating column capacity shows better agreement with the test results tham the existing model.

  • PDF