• Title/Summary/Keyword: Concentric Annuli

Search Result 48, Processing Time 0.025 seconds

Thermal-flow Characteristics of Magnetic Fluid for Concentric Annuli Under Fixing Magnetic Field Using Visualization Technique (가시화기법을 이용한 고정자장에서 이중원관내 자성유체의 열유동 특성에 관한 연구)

  • Kim, Hyung-Jin;Seo, Jae-Hyeong;Kim, Dae-Wan;Lee, Moo-Yeon;Seo, Lee-Soo
    • Journal of the Korean Magnetics Society
    • /
    • v.23 no.1
    • /
    • pp.26-30
    • /
    • 2013
  • This article is experimentally to investigate thermal-flow characteristics of the magnetic fluid for concentric annuli under externally fixed magnetic fields using visualization technique. Temperatures of the inner tube and outer tube in the tested concentric annuli were constantly maintained at both $30^{\circ}C$ and $25^{\circ}C$ and the middle tube was filled with the magnetic fluid. Magnetic field was uniformly applied using 4 permanent magnets at 4 directions of the concentric annuli. As a result, the thermal-flow characteristics of the magnetic fluid for concentric annuli could be controlled by directions of the external magnetic fields.

A Study on the Turbulent Flow in Concentric Annuli with Both Rough Walls (양벽면에 거칠기가 있는 이중동심관내의 난류유동에 관한 연구)

  • 안수환;정양범
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.18 no.3
    • /
    • pp.17-25
    • /
    • 1994
  • Fully developed turbulent flow through three concentric annuli with both the rough inner and outer walls was experimentally investigated for a Reynolds number range Re = 15, 000 - 85, 000. Measurements were carried out for the pressure drop, the positions of zero shear stress and maximum velocity, and the velocity distributions in annuli of radius ratios, ${\alpha}$=0.26, 0.4 and 0.56, respectively. The experimental results showed that the positions of zero shear stress and maximum velocity were only weakly dependent on the Reynolds number.

  • PDF

Turbulence Structures of Flow in Concentric Annuli with Rough Outer Wall (외벽에 거칠기가 있는 이중동심관 유동의 난류구조)

  • 김경천;안수환;이병규
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.9
    • /
    • pp.2443-2453
    • /
    • 1994
  • The structure of turbulence of fully developed flow through four concentric annuli with the rough outer wall was investigated experimentally for a Reynolds number range Re=15, 000-93, 000. Turbulence intensities were measured in three(u, v, w) directions, and turbulence shear stresses in annuli of radius=0.13, 0.26, 0.4 and 0.56, respectively. Due to the square roughness element attached periodically along the axial direction, the radial velocity fluctuations show similar distribution regardless of the different .alpha.cases. However, the axial and circumferential velocity fluctuation profiles demonstrate the longitudinal turbulence structures are strongly influenced by the .alpha. values. The turbulent eddy viscosity deduced form mean velocity distributions and the measured Reynolds shear stresses are also presented and discussed.

Experimental Investigation on the Flow in Concentric Annuli with Both Rough Walls (내·외벽에 거칠기가 있는 이중동심관 유동에 대한 실험적 연구)

  • Ahn, S.W.;Jung, Y.B.;Kim, K.C.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.7 no.1
    • /
    • pp.81-88
    • /
    • 1995
  • Fully developed turbulent flow through three concentric annuli with both the rough inner and outer walls was experimentally investigated for a Reynolds number range Re=15,000-85,000. Measurements were made of the pressure drop, the positions of zero shear stress and maximum velocity, and the velocity distributions in annuli of radius ratios, ${\alpha}=0.26$, 0.4 and 0.56, respectively. The experimental results showed that the positions of zero shear streess and maximum velocity were only weakly dependent on the Reynolds number. It was also found that the position of zero shear stress was not coincident with that of maximum velocity. Furthmore, the former was influenced more sensitively than the latter on the square-ribbed roughness along the axial direction.

  • PDF

Heat Transfer Coefficients of Concentric Annuli for Testing Heat Transfer Characteristics of Alternative Refrigerants in Tubes (대체냉매 관내 열전달특성 시험을 위한 동심이중원관의 환상유로의 열전달계수)

  • KIM, MAN-HOE
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.32 no.1
    • /
    • pp.63-67
    • /
    • 2021
  • Accurate measurements of the heat transfer coefficients of concentric annular space for the test section is important to measure the tube-side heat transfer coefficients of working fluids. This paper presents the annular side heat transfer coefficients of concentric annuli with variation of tube diameter ratios using Wilson plot method. The test facility has a straight, horizontal test section with an active length of 3.0 m. Inner/outer diameters of test tubes are 7.0/7.5 and 8.0/8.56 mm, respectively. An outer diameter of annulus side is 16.0 mm. The test results show that convective heat transfer coefficients in annuli increase with annular diameter ratio. The correlations for convective heat transfer coefficients in annuli are also developed.

The design of heat exchanger of small size steam boiler using the concentric annuli tube with pin fin (동심원관-pin fin 열교환기를 이용한 소형 증기보일러 대류실 설계)

  • Kim, Sungil;Choi, Sangmin
    • 한국연소학회:학술대회논문집
    • /
    • 2012.11a
    • /
    • pp.115-118
    • /
    • 2012
  • The configurations of the heat exchanger of the boiler can be determined from the trade-off between the heat transfer area which is related to the capital cost and the pressure drop which is related to operating cost. In this study, 3.5 ton/hr small size marine boiler having concentric annuli tubes is the design boiler. To determine the optimizing point, according to diameter, number, length of tube, heat transfer, pressure drop, operating cost and capital cost have been calculated. Also, when the fin tube is replaced by the bare tube design parameters changed have been calculated.

  • PDF

A Study on the Heat Transfer Characteristics of Magnetic Fluids in Concentric Double Pipe Annuli (이중원관내 자성유체의 열전달 특성에 관한 연구)

  • Park, J.W.;Park, G.T.;Seo, L.S.
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.1657-1662
    • /
    • 2003
  • In this study, to research characteristics of heat flow of magnetic fluid, it's studied about numerical and experimental method of natural convections change and characteristics of heat transfer in Concentric double pipe annuli as analysis model. In the result, natural convection of magnetic fluid is controlled by direction and strength of the impressed magnetic field. Especially, according to average Nusselt number, heat transfer is the smallest on the balancing point between body force and buoyancy.

  • PDF

Turbulent Heat Transfer in Rough Concentric Annuli With Heating Condition of Constant Wal Heat Flux (일정벽면열유속의 가열조건의 갖는 거친 동심환형관내의 난류열전달)

  • 손유식
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.23 no.1
    • /
    • pp.54-61
    • /
    • 1999
  • The fully developed turbulent momentum and heat transfer induced by the roughness elements on the outer wall surfaces in concentric annuli are analytically studied on the basis of a modified turbu-lence model. The resulting momentum and heat transfer are discussed in terms of various parame-ters such as the radius ratio the roughness density Reynolds number and Prandtl number accord-ing to the heating condition. The study shows that certain artificial roughness elements may be used to enhance heat transfer rates with advantage from the overall efficiency point of view.

  • PDF

Structure of turbulence of fully developed flow in concentric annuli with rough outer wall (거친외벽면을 가진 동심환형관내에서 완전히 발달된 유동의 난류구조)

  • Ahn, S.W.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.1
    • /
    • pp.1-9
    • /
    • 1999
  • For roughened annular pipes with diameter ratios of 0.26, 0.39, and 0.56 and with Reynolds numbers ranging 13,000 to 67,000, friction factor, autocorrelation coefficients, power spectral density functions, and integral length scales for each flow condition using X-type hot wire anemometry system are experimentally investigated. Distributions of these quantities show that the times which the streamwise autocorrelation coefficients become zero first increase with decreasing the radius ratios of concentric annuli and Reynolds numbers, however the power spectra density functions increase with increasing the radius ratios and Reynolds number.

  • PDF

Experimental Study on the Natural Convective Heat Transfer Characteristics of Ferrofluid for Concentric Annuli under Rotating Magnetic Field (회전수 및 자기장강도 변화에 따른 이중원관내 자성유체의 자연대류 열전달 특성에 관한 실험적 연구)

  • Kim, Hyung-Jin;Seo, Jae-Hyeong;Kim, Dae-Wan;Lee, Moo-Yeon;Seo, Lee-Soo
    • Journal of the Korean Magnetics Society
    • /
    • v.23 no.2
    • /
    • pp.77-81
    • /
    • 2013
  • The objective of this study is experimentally to investigate natural convective heat transfer characteristics of the ferrofluid for a concentric annuli under rotating magnetic field with variations of the revolution and the magnetic field strength. The rotating magnetic field was provided by induction motor with 6 poles and 3 phases and the revolution and the magnetic field strength were controlled by an inverter driver and a voltage meter, respectively. Temperatures of the inner pipe and the outer pipe in the tested concentric annuli were maintained at $30^{\circ}C$ and $25^{\circ}C$, respectively, during the test and the direction of the rotating magnetic field was a counterclockwise. As a result, the natural convective heat transfer characteristics of the ferrofluid for a concentric annuli were increased with the rise of the revolution and magnetic field strength due to the increased heat dissipation between hot side and cold side of the concentric annuli.