• Title/Summary/Keyword: Concentration coefficient

검색결과 2,048건 처리시간 0.029초

Tribology of Si incorporated Diamond-like Carbon Films

  • Kim, Myoung-Geun;Lee, Kwang-Rveol;Eun, Kwang-Yong
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 1998년도 제14회 학술발표회 논문개요집
    • /
    • pp.44-44
    • /
    • 1998
  • It was observed that the friction coefficient decreased with increasing Si concentration in the l ilms. Furthermore, the friction behavior became more s때ble even when very small amount of S Si of less than 0.5 at. % was incorporatA:회 By analyzing the composition of the debris f formed, we could show that the low and stabilized friction coefficient is in마nately relatA:었 w with the formation of the Si rich oxide debris. These result supports the mechanism that the h hydrated silica debris is the reason for low friction coefficient in humid environment. Second e evidence of the role of Si rich oxide debris could be found in the triOO-chemical reactions d during initial stage of triho-test. When the Si concen$\sigma$ation was less than 5 at.%, initial t transient period of high friction coefficient was commonly observed. Mter the transient period, m the friction coefficient becomes lower with increasing contact cycles. The initial $\sigma$ansient p peri여 becomes shorter and the starting and maximum friction coefficients in $\sigma$ansient 야,riod d decreased with increasing Si concentration. Composition of the debris on the wear scar s surface was analyzed by Auger spe따'Oscopy at v뼈ous stages in the initial transient period. W We observed that when the friction coefficient increased in earlier stage of the $\sigma$'ansient p period, iron and oxygen was observed in the debris. However, decrease in the 당iction c coefficient in the later stage of the transient period was associated with the formation of s silicon rich oxide debris. This result also supports the friction mechanism of Si-DLC films t that the formation of Si rich oxide debris results in low friction coefficient in ambient a atmosphere. atmosphere.

  • PDF

강우의 염분이 재폭기에 미치는 영향 (Effects of Rainfall and Salinity on Reaeration)

  • 최재성;연기석;김건흥;안상진
    • 물과 미래
    • /
    • 제21권3호
    • /
    • pp.281-290
    • /
    • 1988
  • As the aeration is one of the most important roles for the purification of polluted water, aquatic aerobic microorganism makes use of aerated dissolved oxygen to decompose the pollutant and purify water. In this study, a reactor was operated in a laboratory to examine the effects of salinity and rainfall on reaeration and then a model was proposed to estimate the reaeration coefficient. From the results of the experiments, the reaeration coefficient, $k_2$($day^{-1}$), can be expressed by $k_2=k_{2f}+3.98667{\times}10^{-2}{\cdot}C+4.88437{\times}10^{-1}{\cdot}r\;where\;k_{2f}$ : the reaeration coefficient in the fresh water at $20{\circ}C,\;(day^{-1})$ C: chloride concentration, ($g/{\ell}$), r:rainfall intensity,(mm/hr) Accordingly, it is concluded that the rate of reaeration is proportional to the chloride concentration and rainfall intensity. Also, it is known that the rainfall intensity contributes to the overall oxygen balance in a body of water more significantly than the salinity.

  • PDF

$\alpha$-Amylase로 전분 가수분해를 위한 PEG/Dextran 수성 2상계 구성 (Formation of PEG/Dextran Aqueous Two-Phase System for Starch Hydrolysis Using $\alpha$-Amylase)

  • 박병춘;임동준
    • 한국미생물·생명공학회지
    • /
    • 제20권2호
    • /
    • pp.190-195
    • /
    • 1992
  • Polythylene glycol/dextran 수성 2단계에서 polyethylene glycol의분자량과 농도가 증가할수록 체적비는 증가하고 분배계수는 감소하였다. 또한 dextran의 분자량이 증가할 수록 체적비는 감소하고 분배계수는 증가하였다. 한편 dextran의 농도가 증가할수록 체적비와 분배계수는 감소하였다.

  • PDF

평활관군 내 R-123/오일의 흐름비등 (Flow Boiling of R-123/Oil Mixture in a Plain Tube Bundle)

  • 이진욱;이재호;김내현
    • 설비공학논문집
    • /
    • 제22권10호
    • /
    • pp.704-709
    • /
    • 2010
  • The effect of oil on flow boiling of R-123 in a plain tube bundles was experimentally investigated for a range of quality and heat flux. It is shown that the heat transfer coefficient decreased as the oil concentration increased. Comparison with the previous pool boiling data reveals that the reduction of heat transfer coefficient by oil is more pronounced in pool boiling, and the difference increased with the increase of oil concentration and heat flux. Within the experimental range, the variation of mass flux or quality has negligible effect on the heat transfer coefficient.

소결 마찰재의 마찰특성에 미치는 고체 윤활제의 영향 (The effect of solid lubricant on the frictional characteristics of Cu base sintered friction material.)

  • 정진현;이범주;조정환;정동윤;권석진
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 1996년도 제24회 춘계학술대회
    • /
    • pp.45-54
    • /
    • 1996
  • The effect of graphite on the frictional characteristics of Cu-based sintered friction materials was studied by pin-on-disk type wear test. A study has been carried out concerning the optimum concentration of graphite in sintered friction material to obtain the minimum wear rate and low friction coefficient . Friction coefficient and wear rate were increased as increasing the content of graphite in the matrix. In the study the optimum concentration of graphite was 19vol % to get the minimum wear rate and optimal frick'ion coefficient.

  • PDF

LISST-100과 ADCP를 이용한 광양만 현장 부유입자물질 특성 연구 (Characteristic of In Situ Suspended Particulate Matter at the Gwangyang bay Using LISST-100 and ADCP)

  • 이병관;김석윤
    • 한국환경과학회지
    • /
    • 제18권11호
    • /
    • pp.1299-1307
    • /
    • 2009
  • In order to measure in-situ suspended particle size, volume concentration of suspended particulate matter and current speed, mooring observation was performed at the Gwangyang Bay by using of an optical instrument, 'LISST-100' and an acoustic instrument, 'ADV'(St. S1). And the sediment flux was obtained based on the concentration of suspended particulate matter and current speeds measured at three lines of Gwangyang Bay during ebb and flood tide of August 2006. To investigate the spatial variation of suspended particulate matter, profiling observations were measured difference echo intensity and beam attenuation coefficient by using of ADCP and Transmissometer (Line A, B, C). The suspended sediment flux rate at the mouth of Gwangyang Bay was observed to be higher during asymmetrical than symmetrical of current speeds. The flux of suspended particulate matter concentration and current speeds were transported to southeastern direction of surface layer and northwestern direction of bottom layer at the western area at line A of Gwangyang Bay. Small suspended particles have been found to increase attenuation and transmission more efficiently than similar large particles using acoustic intensity (ADV/ADCP) or optical transmit coefficient (LISST-100/Transmissometer). The application and problems as using optical or acoustic instruments will be detected for use in time varying calibrations to account for non-negligible changes in complex environments in situ particle dynamics are poorly understood.

Vertical distribution of suspended sediment concentration - A case study in Cu Lao Dung Coastal Areas (Vietnam)

  • Tien H. Le Nguyen;Phuoc H. Vo Luong
    • Ocean Systems Engineering
    • /
    • 제13권3호
    • /
    • pp.313-324
    • /
    • 2023
  • The vertical distribution of suspended sediments in the mangrove-mud coast is complicated due to the characterization of cohesive sediment properties, and the influence of hydrodynamic factors. In this study, the time-evolution of suspended sediment concentration (SSC) in water depth is simulated by a one-dimensional model. The model applies in-situ data measured in October 2014 at the outer station in Cu Lao Dung coastal areas, Soc Trang, Vietnam. In the model, parameters which have influence on vertical distribution of SSC include the settling velocity Ws and the diffusion coefficient Kz. The settling velocity depends on the cohesive sediment properties, and the diffusion coefficient depends on the wave-current dynamics. The settling velocity is determined by the settling column experiment in the laboratory, which is a constant of 1.8 × 10-4 ms-1. Two hydrodynamic conditions are simulated including a strong current condition and a strong wave condition. Both simulations show that the SSC near the bottom is much higher than ones at the surface due to higher turbulence at the bottom. At the bottom layer, the SSC is strongly influenced by the current.

수은 폭로 근로자의 혈중 Zinc-Protoporphyrin 및 혈청 Cholinesterase Activity에 관한 조사 연구 (A Study on the Blood Zinc-Protoporphrin and Serum Cholinesterase Activity of Workers Exposed to Mercury Vapor)

  • 김종연;김광종;홍두루미
    • 한국산업보건학회지
    • /
    • 제3권1호
    • /
    • pp.62-67
    • /
    • 1993
  • This study aims at investigating the relationships between the urinary mercury concentration and blood zinc-protoportphyrin, serum cholinestrase activity, making 149 workers exposed to mercury vapor and 68 workers who were not exposed to mercury among the workers in a flurorescent lamp manufactureing factory an object of this investigation. The results are as follows ; 1. In an exposed group the number of those whose urinary mercury concentration showed over $100{\mu}g/l$ was 21 persons (14.3%) among 147 workers. The average urinary mercury concentration was $52.1{\pm}46.1{\mu}g/l$($1.8-361.2{\mu}g/l$), which proved to be higher than the average concentration in a control group. 2. In an exposed group, the average concentration of blood zinc-protoporphyrin was $27.8{\pm}12.5{\mu}g/dl$($12.2-101.5{\mu}g/dl$), which proved to be somewhat higher than the average concentration in a control group. But it did not show a significant difference. 3. In an exposed group, the average concentration of serum cholinesterase activity showed $1936.7{\pm}341.0IU/l$(1,120,0-2,8750IU/l), which proved to be lower than the average concentration in a control group. 4. The relational coefficient between urinary mercury concentration and blool zinc-protoporphyrin, serum cholinesterase activity of the whole workers exposed to mercury showed little difference. While the relational coefficient between the urinary mercury concentration and blood zinc-protoporphyrin of the workers whose urinary mercury concentration showed over $100{\mu}g/l$ was relatively high, which was 0.62.

  • PDF

순수점성 비뉴톤유체의 물성치들에 대한 농도 및 온도의 영향 (Effects of the Concentration and the Temperature on the Thermophysical Properties of Purely-Viscous Non-Newtonian Fluid)

  • 조금남
    • 대한기계학회논문집
    • /
    • 제18권3호
    • /
    • pp.670-680
    • /
    • 1994
  • The thermophysical properties of Non-Newtonian fluid as the function of the temperature and the concentration are needed in many rheological heat transfer and fluid mechanics problems. The present work investigated the effects of the concentration and the temperature on the thermophysical properties of purely-viscous Non-Newtonian fluids such as the isobaric thermal expansion coefficient, density, zero-shear-rate viscosity, and zero-shear-rate dynamic viscosity within the experimental temperature range from $25^{\circ}C$ to $55^{\circ}C$. The densities of the test fluids were determined as the function of the temperature by utilizing a reference density and the least square equation for the measured isobaric thermal expansion coefficient. As the concentration of purely-viscous Non-Newtonian fluid was increased up to 10,000 wppm, the densities were proportionally increased up to 0.4%. The zero-shear-rate viscosities of test fluids were measured before and after the measurements of the first thermal expansion coefficients and the densities of Non-Newtonian fluid. Even though they were changed up to approximately 22% due to thermal aging and cycling, they had no effects on the thermal expansion coefficients and the densities of Non-Newtonian fluid. The zero-shear-rate dynamic viscosities for purely-viscous Non-Newtonian fluids were compared with the values for distilled water. They showed the similar trend with the zero-shear-rate viscosities due to small differences in the densities for both distilled water and purely-viscous Non-Newtonian fluid.

술폰화 poly(arylene ether sulfones) 양이온 교환막의 술폰산기 농도 변화에 따른 특성 (Characteristics of Sulfonated Poly(arylene ether sulfones) Cation-Exchange Membrane by Variation of Sulforic Acid Group Concentration)

  • 김래현;이승용;최선용;이정우;박세용
    • 전기화학회지
    • /
    • 제3권1호
    • /
    • pp.57-62
    • /
    • 2000
  • 이온 교환막의 고정이온 농도변화에 따른 막 특성을 알아보기 위해 matrix인 PSF (polysulfone)과 술폰화제인 CSA(chlorosulfuric acid)의 몰 비를 달리하여 SPSF (sulfonated polysulfone) 양이온 교환수지를 합성하였다. 합성된 SPSF의 이온교환용량, 함수율, 고정이온 농도, 분배계수 등을 측정하였다. DSC, TGA분석으로부터 SPSF의 술폰산기 농도 증가에 따라 벌키한 술폰산기의 도입으로 인하여 유리전이 온도는 증가하고 중량 감소비는 감소하는 것으로 나타났다. 본 실험조건에서는 SPSF막의 구조가 SEM, AFM등의 분석을 통하여 비대칭인 것으로 나타났다. 교류 임피던스로부터 측정한 SPSF 막을 통한 $Na^+$ 이온의 겉보기 확산계수는 술폰산기 농도 증가에 따라 증가하였다.