• Title/Summary/Keyword: Concentration Load

Search Result 1,033, Processing Time 0.029 seconds

Photoelastic Stress Analysis of the Abutment Surrounding Tissue According to Shape of the Proximal Plate of the RPI Clasp (압축하중시 RPI clasp의 3가지 다른 proximal plate 형태에 따른 지대치 주위조직의 광탄성 응력 분석)

  • Choi, Jung Soo;Kim, Busob
    • Journal of Technologic Dentistry
    • /
    • v.34 no.4
    • /
    • pp.473-482
    • /
    • 2012
  • Purpose: The purpose of this study was to investigate the stress distribution of the surrounding tissues according to 3 proximal plate types of the RPI clasp. Methods: The removeable partial denture which mandibular right and left second premolars and mandibular molars were lost was attached to a three dimensional photo elastic epoxy resin model. Then 120N of vertical load was applied. After 3-dimensional photoelastic stress analysis was used to record the isochromatic fringe patterns. Results: Kratochvil type guiding plane exhibited little uniform stress distribution on load center and alveolar ridge, but higher stress concentration on buccal surface of second premolar. Krol type guiding plane exhibited the stress concentration on the front of load center and relatively higher stress concentration on buccal surface of first premolar. However, this type had no effect on canine. Researcher type guiding plane showed the stress concentration on second premolar and molar, but the little stress distribution on first premolar. Conclusion: In all types, excessive stress concentration was appeared and three types were not significant different.

A Survey on the Status of Air Pollution around Toll Booth of Expressway -Around Seoul and Suwon Toll Booth- (고속도로 요금소 주변의 대기오염에 관한 조사연구 -서울 및 수원 요금소를 중심으로-)

  • 이윤재;김정철;김광종;송동빈;차철환;권영근
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.4 no.1
    • /
    • pp.79-83
    • /
    • 1988
  • To improve working environment for the toll workers who were working at Kyungbu expressway in outskirts of Seoul and Suwon, the status of air pollution surrounding toll booth were measured from March 28 through June 14, 1986. The results were as follows: 1. The amount of TSP (total suspended particle) surrounding toll booth was directly proportional to the traffic load. The ratio of traffic load at Seoul and Suwon toll was 3.2:1 and of TSP was 2.6:1. 2. The proportion of particle larger than 5$\mum$ was 24.8 $\sim$ 34.9% of TSP at Seoul toll and 19.2 $\sim$ 32.7% at Suwon. The proportion of particle less than 2$\mum$ was 38.7 $\sim$ 51.8% of TSP at Seoul toll and 34.8 $\sim$ 54.8% at Suwon. 3. The concentration of respirable particle les than 7$\mum$ measured by personal air sampler was higher in Seoul toll booth than that of Suwon and it seems to be influenced by the exhausion of diesel engine. Especially the concentration of respirable particle of reformed toll booth with air curtain was 20% lower than unreformed one. 4. Concentration of Pb among suspended particles around Seoul toll was 5 times higher than Pb of Suwon toll. So it is considered that there were other possible pollution source of Pb beyond heavy traffic in Seoul toll area. The amount of Pb inside toll booth was extremely small but the concentration of benzo(a)pyrene showed a trend of increase according to traffic stagnation. 5. The concentration of $SO_2$ arround toll showed no difference between weekday and weekend and also showed no relation with traffic load. But the concentration of $NO_2$ was affected by traffic load.

  • PDF

Load Concentration Factor Analysis of Fuel Assembly Guide Thimble (핵연료집합체 안내관의 하중집중계수 해석)

  • Lee Young-Shin;Jeon Sang-Youn
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.3 s.168
    • /
    • pp.93-100
    • /
    • 2005
  • The top and bottom nozzles of PWR fuel assembly are connected by guide thimbles and an instrumentation tube that are connected with spacer grids. The fuel rods are inserted into the each cell of spacer grids. The loads acting on the fuel assembly are transmitted to the guide thimbles through the flow plate of top nozzle The axial loads applied to the fuel assembly are not equally distributed among the guide thimble due to the geometry of the top nozzle flow plate and spacer grid. In this study, the load concentration factors for the $17\times17$ fuel assembly were calculated. The analytical model fur the calculation of the load concentration factor of top nozzle flow plate was developed using ANSYS 5.6. The finite element analyses were performed using the model composed of top nozzle, guide thimble, and spacer grid. And, the analysis results were compared with the test results.

Mass Balance of Pollutants at a Paddy Field Area During Irrigation Period (관개기 광역논에서의 오염물질의 수지(지역환경 \circled3))

  • 오승영;김진수;김규성
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2000.10a
    • /
    • pp.617-622
    • /
    • 2000
  • Concentration of pollutants and discharge were monitored regularly at paddy field area during irrigation periods. The amounts of irrigation water during irrigation water during irrigation periods in 1999 were 3690mm. The concentration of pollutants in ponded water are high during fertilizer application period. The ratio of discharge of direct runoff Q$\_$D/ to the total runoff is 9%. The ratios of the load of direct runoff L$\_$D/ to the total load L$\_$T/ are 6% for T-N, 16% for T-P and 16% for COD. It was found that the ratios of the concentration are 0.7 for T-N, 1.8 for T-P and 1.9 for COD. The unit load of T-N, T-P and COD during irrigation periods were 12.1kg/㏊, 0.42kg/㏊ and 85.7kg/㏊, respectively

  • PDF

Estimation of stress concentration factor in bolt jointed structure with variable preload (체결력에 따른 볼트 결합구조물의 응력집중계수 평가)

  • 송준혁
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 1998.03a
    • /
    • pp.298-303
    • /
    • 1998
  • Most of mechanical structures are combined of substructures such as beam and/or plates. There are few system with unibody structures but are not a few systems with united body structures. Generally the dynamic analysis of whole structures is perform ed under alternating load. However, the analysis of each joint area is more important than others for zero severity. This paper presents the results of analysis of concentration stress in bolt jointed structure with variable preload. At frist, a static vibration test was performed to find out a nominal stress of bolt joint ed plates from the relationship between natural frequency and nominal stress. Then a concentration stress was computed at contact point between bolt and plate in the structure. It is believed that the proposed method has promising implications for safer design with fatigue quality index of stress concentration factor and has merit for cost down and saving time at the beginning of vehicle development.

  • PDF

A PHOTOELASTIC STUDY ON THE STRESS ANALYSIS UNDER MADIBULAR DISTAL-EXTENSION REMOVABLE PARTIAL DENTURE WITH DIFFERENT DESIGN OF THE MAJOR CONNECTOR (주 연결장치의 설계변화에 따른 하악 유리단 국소의치의 광탄성 응력 분석에 관한 연구)

  • Lee, Kyw-Chil;Kay, Kee-Sung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.29 no.2
    • /
    • pp.177-194
    • /
    • 1991
  • The purpose of this study was to analyze the magnitude and distribution of stress using a photoelastic model from a distal extension removable partial dentures with three kinds of mandibular major connectors, that is, lingual bar, linguoplate, and swing-lock attachment. A photoelastic model was made of the epoxy resin(PC-1) and hardener(PCH-1) and coated with plastic cement-1 (PC-1) at the lingual surface of the epoxy model and set with three kinds of chrome-cobalt removable partial dentures. A bilateral vertical load of 15kg to the middle portion of the metal bar crossing both the first molars of the right and the left, and a unilateral vertical load of 12.5kg to the right first molar were applied with the use of specially designed loading device and the reflective circular polariscope was used to analyze the photoelastic model under each condition. The following results were obtained : 1. When the bilateral vertical load was applied, the magnitude and distribution of the stress concentration of the edentulous area and the terminal abutment or adjacent teeth was in the order of lingual bar, linguoplate, swing-lock attachment. 2. When the unilateral vertical load was applied, the magnitude and distribution of the stress concentration of the edentulous area and the terminal abutment or adjacent teeth was in the order of lingual bar, linguoplate, swing-lock attachment. 3. When the unilateral vertical load was applied, the magnitude and distribution of the stress concentration of the termial abutment or adjacent teeth on the non-loaded side showed the least stress distribution in case of swing-lock attachment. 4. When the bilateral vertical load and the unilateral vertical load were applied the swing-lock attachment showed the mildest uniform stress distribution on the edentulous area and the alveolar bone around the abutment teeth.

  • PDF

Evaluation of the tributaries by influence index on the mid-lower portion of the Nakdong River basin

  • Lee, Shun-Hwa;Jung, Seung-Gyu;Park, Seoung-Muk;Lee, Byung-Dae
    • Environmental Engineering Research
    • /
    • v.23 no.2
    • /
    • pp.150-158
    • /
    • 2018
  • The deteriorating role of Nakdong River due to the Four Major Rivers Project has caused a series of problems, including water pollution, drying streams, aggravation of the hydroecology. Geumho River and Gyeongseong-cheon had a higher concentration index and is believed to impact the water quality of the main stream. The influence index of Geumho River and Nam River between 2015 and 2016, which have a large amount of discharge, was the highest among the tributaries in terms of the load material balance. Showing the highest average concentration and average load in the index assessment, Geumho River is believed to require an intensive management for improving the water quality of the main stream. Furthermore, when the cumulative percentage of the average concentration and average load was compared based on the water quality improvement of the tributaries mixed to Nakdong River, which was set to 60%, Geumho River, Nam River, Topyeong-cheon, and Cha-cheon, which showed the highest ratio in that order, were determined to require a water quality management program as a priority.

Estimation of Sediment Concentration Factor based on Entropy Theory (엔트로피 이론 기반의 유사농도 인자 산정)

  • Kim, Yeong-Sik;Nam, Yoon-Chang;Jeon, Hae-Sung;Jeon, Kun-Hak;Choo, Yeon-Moon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.10
    • /
    • pp.325-333
    • /
    • 2020
  • Current methods of measuring the sediment concentration of natural streams can be affected by weather conditions and have lower reliability in bed-load sections due to mechanical limits. Theoretical methods have to be used to solve this problem, but they have low reliability compared to the measured values and diverse results for the bed-load sediment concentration. This study proposes a new way to reliably determine the bed-load sediment concentration from the relation with theoretical depth-integrated concentration based on the informational entropy concept. Sediment distribution shows a uniform probability distribution under maximized entropy conditions under some constraints, so a function can be calculated for the sediment distribution and depth-integrated concentration. The parameters of a stream were estimated by a nonlinear regression method using the concentration data from a past experiment. Equilibrium N (EN) was estimated using the relation between two different formulas proposed in this study, which can ease the estimation of both the total sediment distribution and depth-integrated sediment concentration with high reliable results with an average R2 of 0.924.

A Study on the Water Quality Affected by the Rainfall and Influent Rivers in Paldang Reservoir, Korea (강우 및 유입 하천수가 팔당호 수질에 미치는 영향분석)

  • Kim, Jongmin;Noh, Hyeran;Heo, Seongnam;Yang, Heejeong;Park, Jundae
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.3
    • /
    • pp.277-283
    • /
    • 2005
  • This paper aimed to compare the daily water quality as well as the hydrological data gathered for the past two years (2000 to 2001) between the two influent rivers of Paldang reservoir. The analysis also has been carried out to draw out the factors that affect the water quality at the dam site, where the main drinking water drawing point is located. The relationship between total amount of monthly rainfall and monthly inflow showed $r^2=0.74$ (p<0.05). The highest peak of inflow of influent rivers recorded in August and September (in the year of 2000) and July and August (2001). Average inflows of influent rivers in 2000 and 2001 are calculated at 209.0, 161.5 CMS (Bughangang), 268.6, 148.2 CMS(Namhangang), and 7.8, 5.0 CMS (Gyeongancheon). The formula which was driven from the relationship between inflow and COD load of influent rivers, explained that COD concentration in general increased with the inflow. But during the rainy seasons (July, August, and September), COD concentration decreased according to the increase of inflow. The daily rainfall and COD concentration(or load) during the rainy season (August and September in the year of 2000, July and August in 2001) indicated that the peak of COD load correspond with the rainfall, which decreased sharply after 3 or 4 days. The reason was thought that the high COD load was diluted rapidly by the rain flow. Water temperature, pH and conductivity measured at dam site decreased obviously when the inflow sharply increased. Peak period of total phosphorus concentration coincided with that of inflow. In rainy season, chlorophyll-a concentration decreased obviously as the inflow increased. The reason can be ascribed to the flushing effect caused by the operation of floodgate.

Research on Optimal Taper Stud Bolts for Steam Turbines Using the FEM (유한요소법을 이용한 증기터빈용 최적 테이퍼 스터드 볼트에 관한 연구)

  • 이부윤;김태완
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.24 no.2
    • /
    • pp.8-16
    • /
    • 2000
  • The thread load distribution as applied to large stud bolts for steam turbines is investigated using the finite element method. The stress concentration in tapered threads is studied with varying prestress and taper angle. Based upon the thread load distribution, the optimal taper angles to reduce the stress concentration are determined for various prestresses. The presented finite element model is validated by comparing results of the calculated thread load with analytic ones. The optimal taper angles obtained from this research can be used in designing tapered threads of large stud bolts for steam turbines.

  • PDF