• Title/Summary/Keyword: Concentrated Water

Search Result 899, Processing Time 0.033 seconds

Dynamic and static structure analysis of the Obermeyer gate under overflow conditions

  • Feng, Jinhai;Zhou, Shiyue;Xue, Boxiang;Chen, Diyi;Sun, Guoyong;Li, Huanhuan
    • Computers and Concrete
    • /
    • v.29 no.4
    • /
    • pp.209-217
    • /
    • 2022
  • In order to analyze the static and dynamic structural characteristics of the Obermeyer gate under overflow conditions, the force characteristics and vibration characteristics of the shield plate structure are studied based on the fluid-solid coupling theory. In this paper, the effects of the flow rate, airbag pressure and overflow water level on the structural performance of shield plate of air shield dam are explored through the method of controlling variables. The results show that the maximum equivalent stress and total deformation of the shield plate decrease first and then increase with the flow velocity. In addition, they are positively correlated with the airbag pressure. What's more, we find that the maximum equivalent stress of the shield plate decreases first and then increases with the overflow water level, and the total deformation of the shield plate decreases with the overflow water level. What's more importantly, the natural frequency of the shield structure of the Obermeyer gate is concentrated at 50 Hz and 100 Hz, so there is still the possibility of resonance. Once the resonance occurs, the free edge of the shield vibrates back and forth. This work may provide a theoretical reference for the safe and stable operation of the shield of the Obermeyer gate.

Analysis of Flood Resilience of the Stormwater Management Using SWMM Model (SWMM 모델을 이용한 우수 관리 홍수 탄력성 분석)

  • Hwang, Soonho;Kim, Jaekyoung;Kang, Junsuk
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2021.06a
    • /
    • pp.126-126
    • /
    • 2021
  • Stormwater reduction plays an important role in the safety and resilience to flooding in urban areas. Due to rapid climate change, the world is experiencing abnormal climate phenomena, and sudden floods and concentrated torrential rains are frequently occurring in urban basins and the amount of outflow due to stormwater increases. In addition, the damage caused by urban flooding and inundation due to extreme rainfall exceeding the events that occurred in the past increases. To solve this problem, water supply, drainage, and water supply for sustainable urban development, the water management paradigm is shifting from sewage maintenance to water circulation and water-sensitive cities. So, in this study, The purpose of this study is to examine measures to increase the resilience of urban ecosystem systems for urban excellence reduction by analyzing the effects of green infra structures and LID techniques and evaluating changes in resilience. In this study, for simulating and analysis of runoff for various stormwater patterns and LID applications, Storm Water Management Model (SWMM) was used.

  • PDF

Antibacterial Effect of Fermented Rice Water against Food-borne Bacteria in Kitchen Towel (행주 내 식품위해미생물에 대한 쌀뜨물 발효액의 살균 효과)

  • Ha, Ji-Hyoung;Lee, Yu-Si;Lee, Seok-Joo;Hwang, Sun-Soon;Ha, Sang-Do
    • Journal of Food Hygiene and Safety
    • /
    • v.22 no.4
    • /
    • pp.365-369
    • /
    • 2007
  • This study was conducted to seek optimum concentration and treatment time of fermented rice water (Rizen) to disinfect food-borne bacteria in kitchen towel. $2.65\;log_{10}cfu/g$ of E. coli was reduced when double or triple diluted fermented rice water was treated during 2 hours. In case of concentrated fermented rice water, crude and double diluted solutions showed complete sterilization after 2 and 5 hours, respectively. On the other hand, triple, quadruple, quintuple diluted solutions needed 24 hours for complete sterilization. The effect of fermented rice water as a disinfectant was compared with water, detergent and chlorine treatment against E. coli and S. Typhimurium contaminated in kitchen towel. The initial number of E. coli in untreated kitchen towel were $5.0\;log_{10}cfu/g$ and were decreased to 4.32, 3.70 and 3.02 by treatments of water, detergent and chlorine, respectively. The double and triple diluted fermented rice water and double diluted concentrated fermented rice water also reduced the E. coli in kitchen towel to 2.43, 2.30 and $1.88\;log_{10}cfu/g$, respectively. The initial number of S. Typhimurium in untreated kitchen towel were $4.80\;log_{10}cfu/g$ and were decreased to 4.12, 3.58 and 2.81 by treatments of water, detergent and chlorine, respectively. The double and triple diluted fermented rice water and double diluted concentrated fermented rice water also reduced the E. coli in kitchen towel to 2.14, 2.03 and $1.59\;log_{10}cfu/g$, respectively. Consequently, the fermented rice water is thought to be a good disinfectant to reduce food-borne bacteria like E. coli and Salmonella contaminated in kitchen towel.

Water Quality Improvement Plan for Small Streams in the Northernmost Basin of Bukhan River based on Pollution Grade and Typological Analysis Linkage (오염등급과 유형화 분석의 연계에 의한 북한강 최북단 유역 소하천의 수질개선방안 연구)

  • Lee, Yong-Seok;Jun, Man-Sig;Kim, Moon-Sook
    • Journal of Korean Society on Water Environment
    • /
    • v.32 no.3
    • /
    • pp.281-290
    • /
    • 2016
  • In the northernmost basin of the Bukhan River, pollution sources can have a concentrated distribution. In these basins, small streams show low flow with various and rapid water quality change in low pollutants load. Therefore, a water quality improvement plan of small streams and main stem will be necessary to establish the characteristics of small streams. This study selected a representative Hwacheon-gun in the northernmost basin of the Bukhan River. Hydro analysis was performed with GIS tools using DEM. A total of 152 small streams were listed. A total of 51 survey locations were selected after applying the selection criteria. Flow rate and water qualities were investigated. Pollution sources and pollutants loads were calculated for each basin. Pollution grade and typological classification were performed by cluster analysis using standardized environmental condition factors. As a result, G04, G01, H01 locations were found to have the worst pollution grades whereas J01, P01, and P02 had less pollution. Typological analyses were able to classify six types for the surveyed small streams. An effective water quality improvement plan was obtained based on the results of pollution grade and typological analysis using environmental condition factors of this study.

An Experimental Study on the Variation of Vertical Dispersion within Boundary Layer with Surface Roughness (대기 경계층 연직방향 확산의 지면 거칠기에 따른 변화에 관한 실험적 연구)

  • 박옥현;윤창옥
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.16 no.3
    • /
    • pp.237-246
    • /
    • 2000
  • An experimental study has been carried out using a rotating water channel in order to investigate the effect of surface roughness on the vertical dispersion of plume within boundary layer. Dispersion measurements of tracers released from two sources with different height at neutral conditions over various rough terrain ranging from rural to urban have been performed. Various values of roughness length were simulated by combining of 4 stream velocities and 3 roughness element conditions. Dispersion measurements have also been made for rough terrain where high buildings are locally concentrated. Values of $\sigma$z increase with roughness and this tendency appears to apply both cases of with and without locally concentrated high buildings. The comparisons of the Bowne's nomogram on $\sigma$2 vs x relationship and the measurements of $\sigma$2 with roughness show good accordance in $\sigma$2 distribution at stability D class over rural, suburban and urban terrain. For constant roughness length the $\sigma$2 values of plumes from lower source height are smaller than those of plumes from higher source at short downwind distance, but this relationship becomes reverse as distance increases. Crossing appears to be made before about 2km. The value of constant I in McMullen's equation $\sigma$2=exp [I+J(In x) + K(In x)2] appears to increase with roughness length, however, the relationships between other constants and roughness have been confirmed. The values of $\sigma$2 for various downwind distances, estimated by using an equation which is employed in ISC (Industrial Source Complex) dispersion model for areas where high buildings are locally assembled, are in accordance with measurements from water channel experiments.

  • PDF

Preparation of Hydrophilic-Hydrophobic Composites by A Concentrated Emulsion Polymerization Method and Their Permselectivity to Mixture of Water-Ethanol (고농축에멀션중합방법을 이용한 분리막제조와 선택적 흡수성 연구)

  • Park, Jun-Seo
    • Applied Chemistry for Engineering
    • /
    • v.8 no.1
    • /
    • pp.29-38
    • /
    • 1997
  • In the w/o concentrated emulsion, the volume fraction of the dispersed is greater than 0.74 and the hydrophilic liquid is dispersed in the hydrophobic liquid of the continuous phase. The emulsion has the same appearance and behaviour as a gel. The polarity of the hydrophilic liquids and hydrophobic liquids, the pH and the ionic strength of the hydrophilic liquid are found to be important factors in the stability at the polymerization temperature such as $50^{\circ}C$. The lower the polarity of the hydrophobic liquid and the higher the polarity of the hydrophilic liquid, the more stable the emulsion. Electron microscopy studies of the hydrophilic-hydrophobic polymer composites show that the particles of polyacrylamide, the dispersed phase, are separated by he network of the thin film of polystyrene, the continuous phase. This hydrophilic-hydrophobic polymer composites show higher permselectivity to water in the mixture of water-ethanol. The pervaporation experiment shows that the selectivity of the membrane ranges between 4-40 and increases with increasing enthanol concentration in the feed. The rate of permeation decreases with increasing ethanol concentration in the feed.

  • PDF

Characteristics of Chemical Contents of Horizontal Spray Salts from Deep Ocean Water (수평 분무식 해양심층수 소금의 성분 특성)

  • MOON Deok-Soo;KIM Hyun-Ju;SHIN Phil-Kwon;JUNG Dong-Ho
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.38 no.1
    • /
    • pp.65-69
    • /
    • 2005
  • We have developed a new method of manufacturing salts by horizontal spray drying technique, using the concentrated deep ocean water after desalination processes. We studied the chemical characteristics of the spray-dried salts. Sodium content in the spray salts is $28.4\%$, which is $10-30\%$ lower than that of bay salts, bamboo salts and boiling salts $(32-38.2\%)$. However, the contents of magnesium, potassium and calcium of the spray salts are 2.5 times, 3 times and 4.5 times higher relative to those of bay salts, respectively. On the one hand, sulfur content in spray salts is 14 times lower than those of bay salts, which is caused by their volatilization during spray and vaporization of the concentrated seawater. Enrichment factors of Mg (0.8), K (0.9) and Ca (1.0) in the spray salts are relatively higher than those in bay salt (0.2-0.3), bamboo salt (0.15-0.4) and boiled salt (0.4-0.7), respectively. On the contrary, enrichment factor of sulfur in spray salts is observed to be 0.07, which is considerably lower than those in other salts (0.3-0.7). It means that the minerals like Mg, K and Ca can be well conserved from seawater to salts through spray drying techniques, while volatile elements like sulfur, lead, mercury and organic compounds can be easily removed from seawater via spray and heating processes.

The Study on Antioxidation of Retinal (Retinol에 대한 항산화 연구)

  • 조춘구;한창규;홍우진
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.28 no.1
    • /
    • pp.58-70
    • /
    • 2002
  • In an attempt to compare the antioxidation effects of constrain the oxidation and improve the structural stability, retinol and various antioxidants were together encapsulated by liposome. Four water soluble and four oil soluble antioxidants were tested for performance. The influence of tertiary butylhydroquinone(TBHQ), ${\alpha}$-glycosyl rutin(${\alpha}$-G rutin), licorece, pycnogenol as water soluble antioxidants and butylated hydroxytoluene(BHT), ${\alpha}$-lipoic acid, ferulic acid, natural concentrated tooopherol(no-tocopherol) as oil soluble antioxidants on the constraint of oxidation of retinol were investigated. Additional study was conducted to compare the synergic effect of antioxidation for retinol with licorice, pycnogenol, ${\alpha}$-lipoic acid and BHT. All the antioxidant used at the study constrained oxidation of retinol. The effect of antioxidation for retinol increased in order of licorice, pycnogenol, TBHQ, ${\alpha}$-G rutin as water soluble antioxidants and ${\alpha}$-lipoic acid, BHT, no-tocopherol, ferulic acid as oil soluble antioxidants. In conclusion, ${\alpha}$-lipoic acid is more effective retinol antioxidants than BHT. And the combination of ${\alpha}$-lipoic acid and BHT gave best synergic among six combinations.

Problems of lake water management in Korea (한국의 호수 수질관리의 문제점)

  • 김범철;전만식;김윤희
    • Proceedings of the Korean Society of Environment and Ecology Conference
    • /
    • 2003.10a
    • /
    • pp.105-126
    • /
    • 2003
  • In Korea most of annual rainfall is concentrated in several episodic heavy rains during the season of summer monsoon and typhoon. Because of uneven rainfall distribution many dams have been constructed in order to secure water supply in dry seasons. The Han River system has the most dams among Korean rivers, and the river is a series of dams now. Reservoirs need different strategy of water quality control from river water. Autochthonous organic matter and phosphorus should be the major target to be controlled in lakes. In this Paper some problems are discussed that makes efforts of water quality improvement ineffective in lakes of Korea, even after the substantial investment to wastewater treatment facilities.1) Phosphorus is the key factor controlling eutrophication of lakes and the reduction ofphosphors should be the major target of water treatment. However, water quality management strategy in Korea is still stream-oriented, and focused on BOD removal from sewage. Phosphorus removal efficiency remains as low as 10-30%, because biological treatment is adopted for both secondary treatment and advanced treatment. The standard for TP concentration of the sewage treatment plant effluent is 6 mgP/l in most of regions, and 2 mg/l in enforced region near metropolitan water intake point. TP in the effluents of sewage treatment plants are usually 1-2 mg/1, and most of plants meet the effluent regulation without a further phosphorus removal process. The generous TP standard for effluents discourages further efforts to improve phosphorus removal efficiency of sewage treatment. Considering that TP standard for the effluent is below 0.1 mg/l in some countries, it should be amended to below 0.1 mg/l in Korea, especially in the watershed of large lakes.2) Urban runoff and combined sewer overflow are not treated, even though their total loading into lakes can be comparable to municipal sewage discharges on dry days. Chemical coagulation and rapid settling might be the solution to urban runoff in regard of intermittent operation on only rainy days.3) Aggregated precipitation in Korea that is concentrated on several episodic heavyrains per year causes a large amount of nonpoint source pollution loading into lakes. It makes the treatment of nonpoint source discharge by methods of other countries of even rain pattern, such as retention pond or artificial wetland, impractical in Korea.4) The application rate of fertilizers in Korea is ten times as high as the average ofOECD countries. The total manure discharge from animal farming is thought to be over the capacity of soil treatment in Korea. Even though large portion of manure is composted for organic fertilizer, a lot of nutrients and organic matter emanates from organic compost. The reduction of application rate and discharge rate of phosphorus from agricultural fields should be encouraged by incentives and regulations.5) There is a lot of vegetable fields with high slopes in the upstream region of the HanRiver. Soil erosion is severe due to high slopes, and fertilizer is discharged in the form of adsorbed phosphorus on clay surface. The reduction of soil erosion in the upland area should be the major preventive policy for eutrophication. Uplands of high slope must be recovered to forest, and eroded gullies should be reformed into grass-buffered natural streams which are wider and resistant to bank erosion.

  • PDF

Improvement of Gasoline Engine Performance by Modifying the Engine Cooling System (엔진 냉각계 개선을 통한 가솔린엔진의 성능 향상)

  • 류택용;신승용;이은현;최재권
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.6 no.3
    • /
    • pp.1-10
    • /
    • 1998
  • In this paper, we investigated the improvement of characteristics of knock, emission and fuel consumption rate by optimizing the location and size of water transfer holes in cylinder head gasket without change of engine water jacket design itself. The cooling system was modified in the direction of reducing the metal temperature in the head and increasing the metal temperature in the block. The optimization of water transfer holes in cylinder head gasket was obtained by "flow visualization test". The water transfer holes were concentrated in front side of the engine in order to reduce thermal boundary layer in the water jacket of No. 2 and No. 3 combustion changer in the cylinder head, which would have a large knock intensity, and increase thermal boundary layer in the water jacket of the cylinder block. When the modified coolant flow pattern was applied as proposed in this paper, the knock characteristic was improved. The spark timing was advanced up to 2$^{\circ}$ in low and middle speed range at a full load. In addition, HC emission at MBT was reduced by 5.2%, and the fuel consumption rate was decreased up to 1% in the driving condition of 2400 rpm and 250 KPa. However, since this coolant flow pattern mentioned in this paper might deteriorate the performance of vehicle cooling system due to the coolant flow rate reduction, a properly optimized point should be obtained. obtained.

  • PDF