• Title/Summary/Keyword: Computer-aided surgery

Search Result 84, Processing Time 0.028 seconds

The Evaluation of Method for Computerization of Clinical Informations of the Patients of the Department of Thoracic and Cardiovascular Surgery - About the practical method of coding and standardization of the structure of the database file(DBF) - (흉부외과환자 임상정보의 전산화 방법에 대한 고찰;데이터베이스 파일(DBF) 구조의 표준화및 코딩화 방안에 대하여)

  • Song, U-Cheol;Kim, Byeong-Ju;Hong, Gi-U
    • Journal of Chest Surgery
    • /
    • v.25 no.10
    • /
    • pp.989-1000
    • /
    • 1992
  • The concepts of modern type computer are so called "General purpose, stored program and digital computer" that is proposed by Charles Babbage. ENIAC, the initial operational electronic digital computer model, was produced in 1946. During the last 50 years, an epoch-making development of the personal computer was marked. The computerization of all levels of society is going on and also computerization of the general hospital and medical college is developing. But patient data management system for clinician is not used generally. We suggest the use of computer aided data management application programs for the clinical informations of the patients of the Department of Thoracic and Cardiovascular Surgery for better management and to make best of medical informations, to co-operate with the current of this times, and to prepare against the Hospital Information Systems[HIS], actively. Also, we suggest to standardize the format and structure of database files to store the clinical data of the patients By standardization of the database files, we can integrate and relate the data of the individual department or hospital, build up the regional or national statistics of the patients easily, and promote the generation of application programs. The medical network by the communication and computer would be utilized to collect the database files. And finally, we suggest the use of code system to input and search the informations about the diagnosis and operation such as the code system of International Classfication of Disease[WHO] and the table of the classfication of operation of the Ministry of Health and Social Affairs, Korea. In this article, we tried to show the new standards, the essential items for computerization of clinical informations of the patients of the Department of Thoracic and Cardiovascular Surgery.r Surgery.

  • PDF

Development of a Computer Graphics-Based Prototype CAD Tool for Planning Tendon Paths in Hand Rehabilitative Surgery (손 재활수술을 위한 힘줄경로 설계용 컴퓨터그래픽스 기반의 프로토타입 CAD 툴 개발)

  • Yoon, In-Mo
    • The Transactions of the Korea Information Processing Society
    • /
    • v.6 no.12
    • /
    • pp.3435-3446
    • /
    • 1999
  • The application of Computer Aided Design (CAD) tool to rehabilitative surgery of the hand is a new field of endeavor. It is considered that there are currently no existing systems designed to assist the orthopedic surgeon in planning complex procedures such as tendon transfer operations. Most tendon transfer operations are performed by surgeons on the basis of knowledge and experience gained through years of practice. However, with the help of this computer graphics-based CAD tool for planning tendon paths, the planning and the evaluation for the best operation on patients' hands also may be possible. The purpose of this study was to model kinematically the structure of the hand and design a prototype tendon path planning tool with a standard computer graphics library, in order for surgeons to perform tendon transfer surgery more objectively and quantitatively.

  • PDF

The combined use of computer-guided, minimally invasive, flapless corticotomy and clear aligners as a novel approach to moderate crowding: A case report

  • Cassetta, Michele;Altieri, Federica;Pandolfi, Stefano;Giansanti, Matteo
    • The korean journal of orthodontics
    • /
    • v.47 no.2
    • /
    • pp.130-141
    • /
    • 2017
  • The aim of this case report was to describe an innovative orthodontic treatment method that combined surgical and orthodontic techniques. The novel method was used to achieve a positive result in a case of moderate crowding by employing a computer-guided piezocision procedure followed by the use of clear aligners. A 23-year-old woman had a malocclusion with moderate crowding. Her periodontal indices, oral health-related quality of life (OHRQoL), and treatment time were evaluated. The treatment included interproximal corticotomy cuts extending through the entire thickness of the cortical layer, without a full-thickness flap reflection. This was achieved with a three-dimensionally printed surgical guide using computer-aided design and computer-aided manufacturing. Orthodontic force was applied to the teeth immediately after surgery by using clear appliances for better control of tooth movement. The total treatment time was 8 months. The periodontal indices improved after crowding correction, but the oral health impact profile showed a slight deterioration of OHRQoL during the 3 days following surgery. At the 2-year retention follow-up, the stability of treatment was excellent. The reduction in surgical time and patient discomfort, increased periodontal safety and patient acceptability, and accurate control of orthodontic movement without the risk of losing anchorage may encourage the use of this combined technique in appropriate cases.

Digital duplication of provisional prosthesis to fabricate definitive prosthesis for full mouth rehabilitation using double scan technique (잠정수복물의 최종수복물로의 디지털 복제를 통한 완전구강 회복 증례: Double scan technique)

  • Hong, Young-Tack;Koak, Jai-Young;Kim, Seong-Kyun;Heo, Seong-Joo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.1
    • /
    • pp.63-70
    • /
    • 2021
  • Using computer-aided design and manufacturing technique improve quality of treatment in many aspect. This case reports the complete mouth rehabilitation of a patient with amelogenesis imperfecta utilizing digital technology. Clinical examination revealed loss of mastication due to insufficient occlusal stop, missing teeth, interdental spacing due to microdontia, insufficient overbite, and etc. Full veneer crowns for teeth were selected, followed by a fixed partial denture and implant placement was done using CAD-CAM guide template with bone graft for partially edentulous space. Definitive restorations were duplicated by double scanning provisional restorations and successfully delivered to the patient. These full mouth rehabilitation procedures resulted in satisfactory outcomes for the patient functionally and aesthetically.

A Prototype of Robotic External Fixation System for Surgery of Bone Deformity Correction

  • Kim, Yoon-Hyuk;Joo, Sang-Min;Lee, Soon-Geul
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.2448-2450
    • /
    • 2005
  • A robotic external fixation system for the surgery of bone deformity correction was developed to simulate the execution process of mal-unioned femur by the adjustment of the joints of the fixation system. An inverse kinematics analysis algorithm was developed to calculate the necessary rotations and translations at each joint of the robotic system. The computer graphic model was developed for validation of the analysis result and visualization of the surgical process. For given rotational and angular deformity case, the surgical execution process using the robotic system was well matched with the pre-operative planning. The final residual rotational deformities were within $1.0^{\circ}{\sim}1.6^{\circ}$ after surgical correction process. The presented robotic system with computer-aided planning can be useful for knowledge-based fracture treatment and bone deformity correction under external fixation.

  • PDF

Evaluation of alveolar bone grafting in unilateral cleft lip and palate patients using a computer-aided diagnosis system

  • Sutthiprapaporn, Pipop;Tanimoto, Keiji;Nakamoto, Takashi;Kongsomboon, Supaporn;Limmonthol, Saowaluck;Pisek, Poonsak;Keinprasit, Chutimaporn
    • Imaging Science in Dentistry
    • /
    • v.42 no.4
    • /
    • pp.225-229
    • /
    • 2012
  • Purpose: This study aimed to evaluate the trabecular bone changes after alveolar bone grafting in unilateral cleft lip and palate (UCLP) patients using a computer-aided diagnosis (CAD) system. Materials and Methods: The occlusal radiographs taken from 50 UCLP patients were surveyed retrospectively. The images were categorized as: 50 images in group 0 (before bone grafting), 33 images in group 1 (one month after bone grafting), 24 images in group 2 (2-4 months after bone grafting), 15 images in group 3 (5-7 months after bone grafting), and 21 images in group 4 (8 or more months after bone grafting). Each image was grouped as either "non-cleft side" or "cleft side". The CAD system was used five times for each side to calculate the pixel area based on the mathematical morphology. Significant differences were found using a Wilcoxon signed ranks test or paired samples t test. Results: The pixel area showed a significant difference between the "non-cleft side" and "cleft side" in group 0 ($404.27{\pm}103.72/117.73{\pm}92.25$; p=0.00), group 1 ($434.29{\pm}86.70/388.31{\pm}109.51$; p=0.01), and group 4 ($430.98{\pm}98.11/366.71{\pm}154.59$; p=0.02). No significant differences were found in group 2 ($423.57{\pm}98.12/383.47{\pm}135.88$; p=0.06) or group 3 ($433.02{\pm}116.07/384.16{\pm}146.55$; p=0.19). Conclusion: Based on the design of this study, alveolar bone grafting was similar to normal bone within 2-7 months postoperatively.

Mandibular reconstruction with a ready-made type and a custom-made type titanium mesh after mandibular resection in patients with oral cancer

  • Lee, Won-bum;Choi, Won-hyuk;Lee, Hyeong-geun;Choi, Na-rae;Hwang, Dae-seok;Kim, Uk-kyu
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.40
    • /
    • pp.35.1-35.7
    • /
    • 2018
  • Background: After the resection at the mandibular site involving oral cancer, free vascularized fibular graft, a type of vascularized autograft, is often used for the mandibular reconstruction. Titanium mesh (T-mesh) and particulate cancellous bone and marrow (PCBM), however, a type of non-vascularized autograft, can also be used for the reconstruction. With the T-mesh applied even in the chin and angle areas, an aesthetic contour with adequate strength and stable fixation can be achieved, and the pores of the mesh will allow the rapid revascularization of the bone graft site. Especially, this technique does not require microvascular training; as such, the surgery time can be shortened. This advantage allows older patients to undergo the reconstructive surgery. Case presentation: Reported in this article are two cases of mandibular reconstruction using the ready-made type and custom-made type T-mesh, respectively, after mandibular resection. We had operated double blind peer-review process. A 79-year-old female patient visited the authors' clinic with gingival swelling and pain on the left mandibular region. After wide excision and segmental mandibulectomy, a pectoralis major myocutaneous flap was used to cover the intraoral defect. Fourteen months postoperatively, reconstruction using a ready-made type T-mesh (Striker-Leibinger, Freibrug, Germany) and iliac PCBM was done to repair the mandible left body defect. Another 62-year-old female patient visited the authors' clinic with pain on the right mandibular region. After wide excision and segmental mandibulectomy on the mandibular squamous cell carcinoma (SCC), reconstruction was done with a reconstruction plate and a right fibula free flap. Sixteen months postoperatively, reconstruction using a custom-made type T-mesh and iliac PCBM was done to repair the mandibular defect after the failure of the fibula free flap. The CAD-CAM T-mesh was made prior to the operation. Conclusions: In both cases, sufficient new-bone formation was observed in terms of volume and strength. In the CAD-CAM custom-made type T-mesh case, especially, it was much easier to fix screws onto the adjacent mandible, and after the removal of the mesh, the appearance of both patients improved, and the neo-mandibular body showed adequate bony volume for implant or prosthetic restoration.

Does computer-aided diagnostic endoscopy improve the detection of commonly missed polyps? A meta-analysis

  • Arun Sivananthan;Scarlet Nazarian;Lakshmana Ayaru;Kinesh Patel;Hutan Ashrafian;Ara Darzi;Nisha Patel
    • Clinical Endoscopy
    • /
    • v.55 no.3
    • /
    • pp.355-364
    • /
    • 2022
  • Background/Aims: Colonoscopy is the gold standard diagnostic method for colorectal neoplasia, allowing detection and resection of adenomatous polyps; however, significant proportions of adenomas are missed. Computer-aided detection (CADe) systems in endoscopy are currently available to help identify lesions. Diminutive (≤5 mm) and nonpedunculated polyps are most commonly missed. This meta-analysis aimed to assess whether CADe systems can improve the real-time detection of these commonly missed lesions. Methods: A comprehensive literature search was performed. Randomized controlled trials evaluating CADe systems categorized by morphology and lesion size were included. The mean number of polyps and adenomas per patient was derived. Independent proportions and their differences were calculated using DerSimonian and Laird random-effects modeling. Results: Seven studies, including 2,595 CADe-assisted colonoscopies and 2,622 conventional colonoscopies, were analyzed. CADe-assisted colonoscopy demonstrated an 80% increase in the mean number of diminutive adenomas detected per patient compared with conventional colonoscopy (0.31 vs. 0.17; effect size, 0.13; 95% confidence interval [CI], 0.09-0.18); it also demonstrated a 91.7% increase in the mean number of nonpedunculated adenomas detected per patient (0.32 vs. 0.19; effect size, 0.05; 95% CI, 0.02-0.07). Conclusions: CADe-assisted endoscopy significantly improved the detection of most commonly missed adenomas. Although this method is a potentially exciting technology, limitations still apply to current data, prompting the need for further real-time studies.

Applications of Morphing on Facial Model Reconstruction and Surgical Simulation

  • Lee, Tong-Yee;Sun, Yung-Nein;Weng, Tzu-Lun;Lin, Yung-Ching
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 1999.06a
    • /
    • pp.103.2-110
    • /
    • 1999
  • Facial model reconstruction and surgical simulation are essential parts in the computer-aided surgical system. Plastic surgeons use it to design appropriate repair plans and procedures before actual surgery is operated. In this work, the exploration of 3-D metamorphosis to them presents new results in these two parts.

Peripheral Periarterial Sympathectomy for the Treatment of Raynaud's Phenomenon(Case Report) (말초 동맥 교감 신경 절제술을 이용한 레이노드 현상의 치료(증례 보고))

  • Lee, Kwang-Suk;Park, Jong-Woong;Suh, Dong-Hoon
    • Archives of Reconstructive Microsurgery
    • /
    • v.6 no.1
    • /
    • pp.111-116
    • /
    • 1997
  • The treatment of chronic digital pain and cold intolerance due to Raynaud's phenomenon is quite difficult especially it is combined with scleroderma. Several surgical trial such as cervicothoracic sympathectomy have been attempted for the medically unresponsible Raynaud's phenomenon, but their results were unsatisfactory. We have tried peripheral periarterial sympathectomy for the 44 years old female patient who had medically unresponsible severe Raynaud's phenomenon with scleroderma. Periarterial adventitial stripping was performed at the level of wrist, superficial palmar arch, common digital artery and proper digital artery about 1.5-2 cm in length. Preoperative angiography and radioactive angiography were done and preoperatively and postoperatively the blood flow was measured by the desk top computer-aided histogram. Both hands digital pain were markedly reduced after operation and blood flow increased as compaired with the preoperative measure.

  • PDF