• Title/Summary/Keyword: Computer-aided design and computer-aided manufacturing

Search Result 401, Processing Time 0.028 seconds

Structure-Vibration Analysis of Electric Scooter Frame (전동 스쿠터 프레임의 구조 진동해석 연구)

  • Chun, Se-Young;Seong, Ki-Won;Park, Hae-I;Kim, In-Soo;Kang, Seong-Ki
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.15 no.1
    • /
    • pp.116-121
    • /
    • 2016
  • The purpose of this study was to ensure the safety of a scooter frame through a structure and vibration analysis according to the tube thickness and weight of the frame of the electric scooter, which is currently being commercialized. According to the results of this study, the largest displacement value of 0.13238mm appeared in the 3-mm thickness when applying the 100-kg load according to the thickness, and 0.026591mm and 0.019062mm appeared in the 4-mm and 5-mm thicknesses, respectively. The difference between the 4-mm and 5-mm values was 0.007529mm, and it showed low displacement. Thus, the frame of more than 4-mm thickness was considered safe. In addition, the experimental result for the natural frequency from Mode 1 to Mode 6 in the vibration analysis was within 601.88Hz. In the 5-mm frame, the durability regarding the vibration was recognized as the best due to the appearance of the critical frequency (341.03Hz).

Marginal fit of three different nanocomposite inlays fabricated with computer-aided design/computer-aided manufacturing (CAD/CAM) technology: a comparative study

  • Hyunsuk Choi;Jae-Young Jo;Min-Ho Hong
    • Journal of Yeungnam Medical Science
    • /
    • v.41 no.2
    • /
    • pp.80-85
    • /
    • 2024
  • Background: This study aimed to compare and evaluate the marginal fit of nanocomposite computer-aided design/computer-aided manufacturing (CAD/CAM) inlays. Three types of nanocomposite CAD/CAM blocks (HASEM, VITA Enamic, and Lava Ultimate) were used as materials. Methods: Class II disto-occlusal inlay restorations were prepared on a typodont mandibular right first molar using diamond rotary instruments. The inlays were fabricated using CAD/CAM technology and evaluated using the silicone replica technique to measure marginal gaps at five locations on each inlay. The data were analyzed by two-way analysis of variance and Tukey post hoc tests (α=0.05). Results: There were no significant differences in the marginal gaps based on the type of nanocomposite CAD/CAM inlay used (p=0.209). However, there was a significant difference in the marginal gaps between the measurement regions. The gingival region consistently exhibited a larger marginal gap than the axial and occlusal regions (p<0.001). Conclusion: Within the limitations of this in vitro study, the measurement location significantly influenced the marginal fit of class II disto-occlusal inlay restorations. However, there were no significant differences in the marginal gaps among the different types of CAD/CAM blocks. Furthermore, the overall mean marginal fits of the class II disto-occlusal inlay restorations made with the three types of nanocomposite CAD/CAM blocks were within the clinically acceptable range.

A Study on the Computer -Aided Design System of Axisymmetric Deep Drawing Process (축대칭 디프 드로잉 제품의 공정설계 시스템에 관한 연구)

  • Park, S.B.;Choi, Y.;Kim, B.M.;Choi, J.C.;Kim, B.H.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 1995.03a
    • /
    • pp.147-154
    • /
    • 1995
  • In this paper, a computer-aided design system for axisymmetric deep drawing process will be described. An approach to the system is based on the knowledge based system. The system has been written in AutoLISP with personal computer. The system is composed of four main modules, such as input , geometrical design, test & rectification and user modification . The system which aids designer provides powerful capabilities for the design of axisymmetric deep drawing process.

  • PDF

Full-mouth rehabilitation of a patient with loss of posterior support and collapsed occlusion utilizing dental CAD-CAM system (구치부 지지 소실 및 무너진 교합관계를 보이는 환자에서 Dental CAD-CAM system을 활용한 완전 구강 회복 증례)

  • Jung, Jiwon;Heo, Seong-Joo;Kim, Seong-Kyun;Koak, Jai-Young
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.1
    • /
    • pp.44-54
    • /
    • 2022
  • Without proper treatment on the multiple tooth missing area, the lack of posterior support and the supra-eruption of the teeth cause many severe complications of occlusion, vertical dimension and masticatory function. This report is a case of full-mouth rehabilitation of a patient with loss of posterior support and collapsed occlusion due to missing teeth area left untreated for a long time. The patient who is 68-year old male patient had some teeth fallen out while removing his old maxillary denture and was complaining about pain in the region of anterior teeth due to traumatic contact. The vertical dimension was corrected by 4 mm from the top cervical point of the canine through various evaluations and the edentulous area was treated with the implant fixed prostheses through computer guided implant surgery based on the diagnosis and treatment plan for definitive prostheses supported by computed tomography (CT) data analysis and CAD-CAM (Computer-aided design/computer-aided manufacturing) technique. After full mouth rehabilitation, the patient was very satisfied with remarkable improvements in mastication, function, and aesthetics.

The Development of Small and Medium Watergate Design System to the CIM Basement (CIM 기반용 중.소형 수문설계시스템 개발)

  • 성백섭;박창언;김일수;김인주;차용훈;김성현
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2001.10a
    • /
    • pp.330-335
    • /
    • 2001
  • Characteristics of the present world market include demanding and sophisticated customers, requirement of high quality and innovative products, greater product diversity, increasing labour and products costs, availability of diverse alternatives to the customers and smaller batch sizes to satisfy a variety of customer profiles. To fulfil these characteristics, manufacturing companies need to be flexible adaptable, proactive and able to produce variety of products in short time at low cost. The aim of the study is to develop a computer-aided design system for water-gate on AutoCAD R2000 system. The developed system has been written in AutoCAD and VisualLISP with a personal computer, and is composed four modules which are the gate-lifter input module, guide-frame input module, and upgrade module. Based on knowledge-based rules, the system is designed by considering several factors, such as width and height of a water-gate, material, object of product and maximum depth of water.

  • PDF

Accuracy of lingual fixed retainers fabricated using a CAD/CAM bending machine

  • Fu Ping Cui;Jung-Jin Park;Seong-Hun Kim
    • The korean journal of orthodontics
    • /
    • v.54 no.4
    • /
    • pp.257-263
    • /
    • 2024
  • Objective: Lingual fixed retainers, made from 0.0175-inch 3-strand twisted stainless steel wire (TW) and 0.016 × 0.022-inch straight rectangular wire (RW), are generally used in clinical practice. This study aimed to calculate their accuracy by comparing the discrepancy between computer-aided customized retainers made from these two types of wires. Methods: Eleven orthodontic patients were selected, resulting in 22 maxillary and mandibular three-dimensional printing dental models. Two types of lingual fixed retainers were bonded from canine to canine. To determine the accuracy, five points were chosen for each model, resulting in 110 selected points. The absolute values of the distances on the x-, y-, and z-axes were measured to compare the accuracy of the two types of computer-aided retainers. Results: The accuracy of the two types of retainers did not differ significantly in the x- and z-axes, but only in the y-axis (P < 0.01), where RW-fixed retainers exhibited a slightly but significantly increased distance compared to the TW. Conclusions: Both types of retainers showed high accuracy; however, RW had a slight but statistically significant difference along the y-axis compared with TW. This type of computer-aided design/computer-aided manufacturing bending machine is limited to two dimensions, and the dental arch is curved. Therefore, RW may require slight manual adjustment by the practitioner after manufacturing.

The application of "bone window technique" using piezoelectric saws and a CAD/CAM-guided surgical stent in endodontic microsurgery on a mandibular molar case

  • Kim, Ukseong;Kim, Sunil;Kim, Euiseong
    • Restorative Dentistry and Endodontics
    • /
    • v.45 no.3
    • /
    • pp.27.1-27.9
    • /
    • 2020
  • Apical surgery for a mandibular molar is still challenging for many reasons. This report describes the applications of computer-guided cortical 'bone-window technique' using piezoelectric saws that prevented any nerve damage in performing endodontic microsurgery of a mandibular molar. A 49-year-old woman presented with gumboil on tooth #36 (previously endodontically treated tooth) and was diagnosed with chronic apical abscess. Periapical lesions were confirmed using cone-beam computed tomography (CBCT). Endodontic microsurgery for the mesial and distal roots of tooth #36 was planned. Following the transfer of data of the CBCT images and the scanned cast to an implant surgical planning program, data from both devices were merged. A surgical stent was designed, on the superimposed three-dimensional model, to guide the preparation of a cortical window on the buccal side of tooth #36. Endodontic microsurgery was performed with a printed surgical template. Minimal osteotomy was required and preservation of the buccal cortical plate rendered this endodontic surgery less traumatic. No postoperative complications such as mental nerve damage were reported. Window technique guided by a computer-aided design/computer-aided manufacture based surgical template can be considerably useful in endodontic microsurgery in complicated cases.

Fabrication of complete denture using 3D printing: a case report (3D 프린팅을 이용한 양악 총의치 제작 증례)

  • Lee, Eunsu;Park, Chan;Yun, Kwidug;Lim, Hyun-Pil;Park, Sangwon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.2
    • /
    • pp.202-210
    • /
    • 2022
  • Recently with the advance in digital dentistry, the fabrication of dentures using computer-aided design and computer-aided manufacturing (CAD-CAM) is on the rise. The denture designed through a CAD software can be produced in a 3-dimensional manufacturing process. This process includes a subtractive processing method such as milling and an additive processing method such as 3D printing and in which it can be applied efficiently in more complex structures. In this case, complete dentures were fabricated using Stereolithography (SLA)-based 3D printing to shorten the production time and interval of visits in patient with physical disabilities due to cerebral infarction. For definitive impression, the existing interim denture was digitally replicated and used as an individual tray. The definitive impression obtained with polyvinyl siloxane impression material was including information about the inclination and length of the maxillary anterior teeth, vertical dimension, and centric relation. In addition, facial scan data with interim denture was obtained so that it can be used as a reference in determination of the occlusal plane and in arrangement of artificial teeth during laboratory work. Artificial teeth were arranged through a CAD program, and a gingival festooning was performed. The definitive dentures were printed by SLA-based 3D printer using a FDA-approved liquid photocurable resin. The denture showed adequate retention, support, and stability, and results were satisfied functionally and aesthetically.

The treatment of an edentulous patient with conventional complete denture and CAD/CAM complete denture (Conventional한 방식과 CAD/CAM System을 이용한 완전 무치악 환자 동시 수복 증례)

  • Cho, Sungyoon;Lee, Joonseok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.58 no.1
    • /
    • pp.42-49
    • /
    • 2020
  • In patients with fully edentulous jaw, treatment of complete dentures should be carried out in many stages when following the conventional methods. Therefore there were disadvantages such as multiple visits to dental clinic is inevitable. In addition, errors caused by polymerization shrinkage, which happens during the fabrication of denture, and difficulties in reproduction of damaged or lost denture were considered as disadvantages. But nowadays, computer-aided design and computer-aided manufacturing (CAD/CAM) system is widely used in dentistry and it has begun to expand its spectrum in manufacturing complete dentures. Using CAD/CAM system to fabricate complete dentures can reduce the number of patient's visit and clinical chair time, since taking impression, recording jaw relation, and selection of artificial teeth are performed at the same time during the first visit, and delivering of dentures during the second visit is possible. In addition, because 3D-Printing technology is used, errors by polymerization shrinkage can be reduced. Among the companies that fabricate complete dentures using CAD/CAM system, DENTCA CAD/CAM denture (DENTCA Inc., Los Angeles, CA, USA) is the most commercialized company. In this case, we treated patients of complete dentures using conventional complete denture method and DENTCA CAD/CAM denture system in the same patient. We would like to report this case because we have achieved good results not only in functional aspects of pronunciation, chewing, and swallowing but also in aesthetic aspects.

Development of a DMU System Operated on a PDM System (PDM 시스템에서 운용되는 DMU 시스템 개발)

  • 이강수;이상헌
    • Korean Journal of Computational Design and Engineering
    • /
    • v.8 no.3
    • /
    • pp.157-166
    • /
    • 2003
  • In this paper, we explain the DMU (digital mockup) system based on the PDM system. Most manufacturing companies are trying to develop a competitive product by increasing the quality, shortening time to market (TIM) and reducing the cost of a product. Some technologies such as SE (System Engineering), CE (Concurrent Engineering), QFD (Quality Function Development), CI (Cost Innovation) and some systems such as CAD (Computer-Aided Design), CAE (Computer-Aided Engineering), CAM (Computer-Aided Manufacturing), PDM (Product Data Management) and visualization system are adopted for these purposes. Specially, DMU system utilizes a visualization system that shows the 3D shape of a product on the computer and it gives a quick intuition to a person whether he/she is an engineer or not. It also can induce the effects of CE and QFD. SO, 0 company is developing a DMU system integrating CAD, visualization and PDM system. The main feature of the developed DMU system is that it is entirely integrated with PDM system, which means that the 3D shape of any part or assembly can be retrieved through PDM system. The DMU system will change the development process, which will increase the competitiveness of a developed product.