• Title/Summary/Keyword: Computer-aided Research

Search Result 516, Processing Time 0.026 seconds

Marginal fit of anterior 3-unit fixed partial zirconia restorations using different CAD/CAM systems

  • Song, Tae-Jin;Kwon, Taek-Ka;Yang, Jae-Ho;Han, Jung-Suk;Lee, Jai-Bong;Kim, Sung-Hun;Yeo, In-Sung
    • The Journal of Advanced Prosthodontics
    • /
    • v.5 no.3
    • /
    • pp.219-225
    • /
    • 2013
  • PURPOSE. Few studies have investigated the marginal accuracy of 3-unit zirconia fixed partial dentures (FPDs) fabricated by computer-aided design/computer-aided manufacturing (CAD/CAM) system. The purpose of this study was to compare the marginal fit of zirconia FPDs made using two CAD/CAM systems with that of metal-ceramic FPDs. MATERIALS AND METHODS. Artificial resin maxillary central and lateral incisors were prepared for 3-unit FPDs and fixed in yellow stone. This model was duplicated to epoxy resin die. On the resin die, 15 three-unit FPDs were fabricated per group (45 in total): Group A, zirconia 3-unit FPDs made with the Everest system; Group B, zirconia 3-unit FPDs made with the Lava system; and Group C, metal-ceramic 3-unit FPDs. They were cemented to resin dies with resin cement. After removal of pontic, each retainer was separated and observed under a microscope (Presize 440C). Marginal gaps of experimental groups were analyzed using one-way ANOVA and Duncan test. RESULTS. Mean marginal gaps of 3-unit FPDs were $60.46{\mu}m$ for the Everest group, $78.71{\mu}m$ for the Lava group, and $81.32{\mu}m$ for the metal-ceramic group. The Everest group demonstrated significantly smaller marginal gap than the Lava and the metal-ceramic groups (P<.05). The marginal gap did not significantly differ between the Lava and the metal-ceramic groups (P>.05). CONCLUSION. The marginal gaps of anterior 3-unit zirconia FPD differed according to CAD/CAM systems, but still fell within clinically acceptable ranges compared with conventional metal-ceramic restoration.

Fixed Prosthetic Restoration in an Edentulous Patient with NobelGuideTM System (양악 무치악 환자에서 NobelGuideTM 시스템을 이용한 고정성 임플란트 보철수복)

  • Shin, Hyoung-Joo;Kim, Dae-Gon;Cho, Lee-Ra;Park, Chan-Jin
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.25 no.3
    • /
    • pp.243-253
    • /
    • 2009
  • This report described a technique utilizing a computer-aided design (CAD) /computer-aided machining (CAM) - guided surgical implant placement and prefabricated fixed complete denture for an immediately loaded restoration. A patient with an edentulous maxilla and mandible received 6 implants in maxilla and 6 implants in the mandible using CAD/CAM surgical templates. Prefabricated provisional maxillary and mandibular implant supported fixed prostheses were connected immediately after implant installation. Provisional prostheses were evaluated for aesthetics, function during 6 months. Definitive prostheses were fabricated.

Comparison of CAD/CAM abutment and prefabricated abutment in Morse taper internal type implant after cyclic loading: Axial displacement, removal torque, and tensile removal force

  • Yi, Yuseung;Heo, Seong-Joo;Koak, Jai-Young;Kim, Seong-Kyun
    • The Journal of Advanced Prosthodontics
    • /
    • v.11 no.6
    • /
    • pp.305-312
    • /
    • 2019
  • PURPOSE. The purpose of this study was to compare computer-aided design/computer-aided manufacturing (CAD/CAM) abutment and prefabricated abutment in Morse taper internal connection type implants after cyclic loading. MATERIALS AND METHODS. The study was conducted with internal type implants of two different manufacturers (Group Os, De). Fourteen assemblies were prepared for each manufacturer group and divided into 2 groups (n=7): prefabricated abutments (Os-P, De-P) and CAD/CAM abutments (Os-C, De-C). The amount of axial displacement and the removal torque values (RTVs) were measured before and after cyclic loading (106 cycles, 3 Hz with 150 N), and the tensile removal force to dislodge the abutments was measured after cyclic loading. A repeated measures ANOVA and a pattern analysis based on the logarithmic regression model were conducted to evaluate the effect of cyclic loading on the axial displacement. The Wilcoxon signed-rank test and the Mann-Whitney test was conducted for comparison of RTV reduction% and tensile removal forces. RESULTS. There was no significant difference between CAD/CAM abutments and prefabricated abutments in axial displacement and tensile removal force; however, significantly greater RTV reduction% after cyclic loading was observed in CAD/CAM abutments. The correlation among the axial displacement, the RTV, and the tensile removal force was not significant. CONCLUSION. The use of CAD/CAM abutment did not significantly affect the amount of axial displacement and tensile removal force, but presented a significantly greater removal torque reduction% than prefabricated abutments. The connection stability due to the friction at the abutment-implant interface of CAD/CAM abutments may not be different from prefabricated abutment.

Disabled Alpine Ski Athlete's Kinematic Characteristic Changes by Computer Aided Design Based Mono Ski Bucket: A Case Study (컴퓨터 디자인 기반 모노스키 버킷 사용에 따른 장애인 알파인 스키 선수의 운동학적 특성 변화 연구: 사례 연구)

  • Koo, Dohoon;Eun, Seondeok;Hyun, Boram;Kweon, Hyosun
    • Korean Journal of Applied Biomechanics
    • /
    • v.24 no.4
    • /
    • pp.425-433
    • /
    • 2014
  • The purpose of the study was to investigate the effect of CAD (Computer Aided Design) based alpine mono-ski bucket design on disabled ski athletes' kinematic characteristics. Two national team ski athletes with LW11 disabilities (Locomotion Winter Classification) category for sit ski participated in both pre and post experiment. Both of the subjects performed 3 trials of carved turn on a ski slope under two conditions. Where, subject "A" performed pre experiment with personal bucket and post experiment with the newly developed CAD based bucket whereas, Subject "B" as control subject performed both pre and post experiment with his personal bucket. For the experiment, 24 Infrared cameras were positioned on the ski slope which covered the path of the ski turn. Also, motion capture suit with reflective markers were worn by both subjects. In the result, decrement in medial/lateral displacement of COM, anterior/posterior displacement of COM, flexion/extension angle of trunk as well as velocity losing rate of COM was observed in subject "A" when using the newly developed CAD based bucket. In contrast, no larger effect on performance was observed when using personal buckets. In conclusion, the findings obtained from the study indicated effectiveness of newly developed CAD based bucket by reducing excessive movement of hip and trunk which is an important factor to perform an effective turn.

Feature Recognition: the State of the Art

  • JungHyun Han
    • Korean Journal of Computational Design and Engineering
    • /
    • v.3 no.1
    • /
    • pp.68-85
    • /
    • 1998
  • Solid modeling refers to techniques for unambiguous representations of three-dimensional objects. Feature recognition is a sub-discipline focusing on the design and implementation of algorithms for detecting manufacturing information such as holes, slots, etc. in a solid model. Automated feature recognition has been an active research area in stolid modeling for many years, and is considered to be a critical component for CAD/CAM integration. This paper gives a technical overview of the state of the art in feature recognition research. Rather than giving an exhaustive survey, I focus on the three currently dominant feature recognition technologies: graph-based algorithms, volumetric decomposition techniques, and hint-based geometric reasoning. For each approach, I present a detailed description of the algorithms being employed along with some assessments of the technology. I conclude by outlining important open research and development issues.

  • PDF

A Study on Dart Manipulation of Women's Front Bodice by Computer-Aided Design (컴퓨터디자인에 의한 Front Bodice의 Dart 변형에 관한 연구)

  • 신상무
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.18 no.2
    • /
    • pp.189-196
    • /
    • 1994
  • The purpose of this study is to develop a computer program for automatic dart manipulation, as well as basic pattern making, of women's front bodice. In addition to accuracy and efficiency In pattern making, this computer program provides variations of basic patterns through dart manipulation. AutoCAD, running on the Austin 486DX micro-computer is used for this research. The procedures of this study are as follows : 1. A pattern-making method for women's front bodice is selected. 2. All co-ordinate points are located following the same way and order of drafting. 3. Drafting of a basic front bodice is programmed 4. Functions for various single dart manipulations are defined. 5. Menu-driven user interface is developed.

  • PDF

A Study on the Development of Computer-Aided Fashion Design (컴퓨터를 활용한 패션디자인 전개방법 연구)

  • 이순자;박옥련;김주현
    • The Research Journal of the Costume Culture
    • /
    • v.8 no.5
    • /
    • pp.717-725
    • /
    • 2000
  • The purpose of this study was, as an experimental one, to suggest concrete ways to use computer in fashion design from information collection to design completion, and to present a real example based on the suggested ways. The first step to attain the purpose was gathering various sorts of worldwide fashion design information on the Internet, and then the collected data were inserted in a graphic file. Next, two methods of fashion design that use computer graphics were recommended : one was to produce fashion design just by altering some of the inputted Internet fashion materials, and the other was to do it after selected basic materials were put in database. Those methods could enable one to do fashion design just with rearrangement and smallest change of the prepared basic materials, without drawing directly, and at the same time, they could minimize time and efforts required for computer fashion design.

  • PDF

Biomechanical Analysis of Body Balance

  • Jeong, Byung-Yong
    • Journal of Biomedical Engineering Research
    • /
    • v.9 no.2
    • /
    • pp.233-238
    • /
    • 1988
  • Human body sways continuously to maintain balance during upright stance. A computer-aided instrumentation system using a force platform has been developed to investigate the body balance. The Kistler force platform and amplifiers were only used to obtain the precise measurements, and the data acquisition and analysis software operating on an IBM PC with A/D converter was developed. This study presents methods for the display of platform center of pressure data on stability study. This system can be used as a tool in evaluating the man's ability to balance and disorders of the nervous system.

  • PDF

Development of computer aided calibration module for CMMS and machine tools using a compensated step gauge

  • Pahk, Heuijae;Kim, Jonghoo
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 1992.04b
    • /
    • pp.444-453
    • /
    • 1992
  • 이 논문은 스텝게이지와 마이크로 컴퓨터를 이용하여 온라인으로 3차원좌표측정기의 오차를 보정하는 시스템에 관한 것이다. 이때 사용하는 스텝게이지는 미리 교정을 실시하여 그 교정데이타를 컴퓨터상에 저장하고 있다. 측정기의 작업영역안에서 어떠한 방향으로 스텝게이지가 놓여 있어도 초기점을 지정하면 CNC타입의 코드를 자동으로 생성하여 스텝게이지 측정을 실시하며 그 측정결과는 3차원 좌표측정기의 오차를 보정하는데 사용된다. 결과적으로 경제적이고 실용적인 오차보정 시스템을 구현할 수 있다.

  • PDF

Development of the gas-filled titanium golf-club driver (가스충진 티타늄 골프 클럽 드라이버 개발)

  • 강영호
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 1999.03b
    • /
    • pp.149-152
    • /
    • 1999
  • Computer-Aided Engineering (CAE) is one of the most effective method in design of golf clubs for determination of optimum shapes in short lead time. A new design of golf club drive with gas-filled titanium head has been carried out using two FEM softwares MARC and DYNA-3D. The main research work focuses on the decision of face thickness and the effect of filled gas pressure by analyzing the change of the kinematic energy of the ball during impact.

  • PDF