• Title/Summary/Keyword: Computer controlled system

Search Result 846, Processing Time 0.028 seconds

A Development of Remote Control System using PDA based WINDOWS CE .NET (WINDOWS CE .NET 기반의 PDA를 이용한 원격제어시스템 개발)

  • Yang, Won-Seok;Lee, Yoo-Sang;Jeon, Jae-Wuk;Moon, Il-Hyeon;Jeon, Chang-Wan;Ahn, Dal;Lim, Jong-Sik;Choi, Kwan-Sun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.8 no.6
    • /
    • pp.1480-1490
    • /
    • 2007
  • This study implemented a remote control system using PDA based on WINDOWS CE. NET. In existing remote control systems, the user generally controls remote objects and obtain data using a computer, which is a local system connected to the internet, and the remote objects are connected to server computers. In order to control remote objects, the user has to have a computer, a space to use the Internet, and wired internet. The system proposed in this study uses an embedded board as a server and PDA as a client. Thus, the user can control remote objects at any place as long as wireless internet is available. In addition, because an embedded board is used as a server, the system has the characteristics of high performance and low power consumption. The proposed system provides not only remote control environment using PDA but also conventional control environment using a computer as a client. In case PDA is not available, remote objects still can be controlled from any place as long as there are wired internet and a computer.

  • PDF

A Study on the Development of a System for Measuring Dielectric Hysteresis (유전 히스테리시스 특성 측정장치의 연구 개발)

  • 강대하
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.12 no.1
    • /
    • pp.58-68
    • /
    • 1998
  • A computer-controlled system for measuring dielectric hysteresis has been developed. This system consists of the wave generation par\, the high voltage amplifier part, the measurement part, the data acquisition part and the related controll circuits and is interfaced to P.C(personal computer). The applied voltage and its frequency are controlled by P.C . Since the measured datas can be saved in the RAM of P.C, the analysis and the graphics of the datas are very convenient. As a accuracy test, the capcitances of the commercial mica and styroll capacitors were measured by applying high voltage and the results were good agreement with the rating values. In the test of PZT ceramic sample, the typical D-E hysteresis loops were obtained by applying a single frequency voltage to the sample, and $\varepsilon-E$ and D-E hysteresis loops could be measured at the same time by applying a double frequency voltage to the sample.sample.

  • PDF

Speed Control of Induction Motor Driven by Stator Voltage-Controlled CSI (고정자전압제어 전류형 인버터에 의한 유도전동기의 속도제어)

  • Song, Joong-Ho;Yoon, Tae-Woong;Kim, Kwang-Bae
    • Proceedings of the KIEE Conference
    • /
    • 1991.07a
    • /
    • pp.583-586
    • /
    • 1991
  • This paper presents a comprehensive study on the stability of several control schemes for the induction motor driven by current source inverters. A stator voltage-controlled current source inverter drive system without a speed sensor is investigated in order to find appropriate control schemes, which are primarily based on direct or, alternatively, indirect frequency control scheme. The overall control systems with either voltage control loop or current and voltage control loops provided in addition to each frequency control scheme are analyzed by utilizing the root locus method and simulated by computer to illustrate the validity of this analysis.

  • PDF

Analysis of the Admittance Component for Digitally Controlled Single-Phase Bridgeless PFC Converter

  • Cho, Younghoon;Mok, Hyungsoo;Lai, Jih-Sheng
    • Journal of Power Electronics
    • /
    • v.13 no.4
    • /
    • pp.600-608
    • /
    • 2013
  • This paper analyzes the effect of the admittance component for the digitally controlled single-phase bridgeless power factor correction (PFC) converter. To do this, it is shown how the digital delay effects such as the digital pulse-width modulation (DPWM) and the computation delays restrict the bandwidth of the converter. After that, the admittance effect of the entire digital control system is analyzed when the bridgeless PFC converter which has the limited bandwidth is connected to the grid. From this, the waveform distortion of the input current is explained and the compensation method for the admittance component is suggested to improve the quality of the input current. Both the simulations and the experiments are performed to verify the analyses taken in this paper for the 1 kW bridgeless PFC converter prototype.

On a Ship Manoeuvring Simulator Newly Developed by Korea Maritime University

  • Sohn, Kyoung-Ho;Kim, Jin-Kook;Yang, Seung-Yeul
    • Proceedings of KOSOMES biannual meeting
    • /
    • 2002.10a
    • /
    • pp.111-124
    • /
    • 2002
  • Ship manoeuvring simulator has been widely utilized for training mariners, for assessing safety, for developing harbour and port, and for designing ships. We discuss a ship manoeuvring simulator which has been newly developed by Korea Maritime University. The simulator consists of simulator bridge and control console. All the computers used in the simulator are connected with one another by UDP or TCP network system. All the instruments are connected with interface computer by signal line which is controlled by RS232 communication protocol, or by voltage controlled A/D board. Next the mathematical model of ship manoeuvring motion in harbour areas, and ship and terrain modeling technique are also briefly discussed. Finally using the simulator an experiment of distance cognition and a simulation example of berthing/deberthing manoeuvre are shown.

  • PDF

Manufacture of Control and Data Acquisition System of Centrifugal Thin Film Evaporator(Centri-Therm, CT-1B) by Computer (컴퓨터를 이용한 원심식 박막증발기의 제어 및 자료 수집 시스템의 제작)

  • Park, Noh-Hyun;Kim, Byeong-Sam;Park, Moo-Hyun;Han, Bong-Ho;Bae, Tae-Jin
    • Korean Journal of Food Science and Technology
    • /
    • v.22 no.4
    • /
    • pp.479-485
    • /
    • 1990
  • For the automation of a evaporation process, computer based evaporation system was built and applied to acquisition of the process variables with an centrifugal thin film evaporator(Centri-Therm, CT-1B). Controls of the process conditions were performed by computer system for pressure, feeding rate, steam, evaporation temperature and flow rate of cooling water. The data acquisitions were also performed by computer system for the changes in the concentration and temperature readings for steam, evaporation and cooling water at the both inlet and outlet. The control and the acquisition variables were collected through the interface device and analyzed by programs using the PASCAL language. To control the feeding rate during the concentration process, inverter was used. The cooling water for the vapor condensation was controlled by the valve controller and should be supplied with the flow rate of 125 kg/h. The maximum vapor condensation rate was 41.7kg/h at the feeding rate of 125 kg/h.

  • PDF

Design and Implementation of a Bidirectional Power Supply Charger Using Super Capacitors and Solar Panel for Robot Cleaner Applications (슈퍼 커패시터 및 태양전지를 이용한 로봇청소기용 양방향 충전시스템 설계)

  • Zheng, Tao;Piao, Sheng-Xu;Kwon, Dae-Hwan;Qiu, Wei-Jing;Kim, Hee-Je
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.1
    • /
    • pp.97-102
    • /
    • 2016
  • In this paper, a bidirectional power supply charger is proposed. This system used a solar cell panel to generate electricity and used super capacitors to store these energies, which can be used for the robot cleaner or some other electronic products. This system include a phase-shift controlled bidirectional dual active bridge (DAB) converter, solar panel super capacitors and DSP controller. In the daytime it can charge to the super capacitors to store the energy generated by the solar cell panel and in the night it will release the energy stored in the super capacitors to loads. A prototype of the proposed bidirectional power supply charger system was designed which can achieve 18V to 30V input, 10V/20W output to super capacitors and 9V/6.5W output when it acts as a charger for the robot cleaner. The system is verified to be sTable and reliable by both the simulation and experimental results.

A Double-Blind, Sham-Controlled, Pilot Study to Assess the Effects of the Concomitant Use of Transcranial Direct Current Stimulation with the Computer Assisted Cognitive Rehabilitation to the Prefrontal Cortex on Cognitive Functions in Patients with Stroke

  • Park, See-Hyun;Koh, Eun-Jeong;Choi, Ha-Young;Ko, Myoung-Hwan
    • Journal of Korean Neurosurgical Society
    • /
    • v.54 no.6
    • /
    • pp.484-488
    • /
    • 2013
  • Objective : To examine the synergistic effects of both computer-assisted cognitive rehabilitation (CACR) and transcranial direct current stimulation (tDCS) on cognitive function in patients with stroke. Methods : The current double-blind, sham-controlled study enrolled a total of 11 patients who were newly diagnosed with stroke. The patients of the tDCS group (n=6) completed sessions of the Korean computer-assisted cognitive rehabilitation program five times a week for 30 minutes a session during a mean period of 18.5 days concomitantly with the anodal tDCS over the bilateral prefrontal cortex combined with the CACR. The patients of the control group (n=5) also completed sessions of the sham stimulation during a mean period of 17.8 days. Anodal tDCS over bilateral prefrontal cortex (F3 and F4 in 10-20 EEG system) was delivered for 30 minutes at an intensity of 2 mA. Cathode electrodes were applied to the non-dominant arm. All the patients were evaluated using the Seoul Computerized Neuropsychological Test (SCNT) and the Korean Mini-Mental State Examination. Results : Mann-Whitney U test revealed a significant difference between the two groups. The patients of the tDCS group achieved a significant improvement in the post/pre ratio of auditory continuous performance test and visual continuous performance test on the SCNT items. Conclusion : Our results indicate that the concomitant use of the tDCS with CACR to the prefrontal cortex may provide additional beneficial effects in improving the cognitive dysfunction for patients with stroke.

Smart Emotion Lighting Control System Based on Android Platform (안드로이드 플랫폼 기반의 스마트 감성조명 제어 시스템)

  • Jo, Eun-Ja;Lin, Chi-Ho
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.14 no.3
    • /
    • pp.147-153
    • /
    • 2014
  • In this paper, we propose smart emotional lighting control system based on the android platform. The proposed smart emotional lighting control system be configure android platform and sensibility lighting equipment, expansion device, zigbee module. Smart emotional lighting control system based on the android platform is automatic control possible using the illumination sensor, and by selecting the desired lighting partial control can be designed. The experimental results of the proposed smart emotional lighting control sensitivity than conventional lighting control system decreased the power consumption and efficient lighting control was possible. Office acts will be suitable conditions to control the color and brightness, so they can be controlled from the improves concentration and ability to work.

Development of Real Time On-Line Thickness Measuring System for Insulated Pipeline (단열배관의 온라인 두께측정시스템 개발)

  • Jang, Ji-Hun;Kim, Byeong-Ju;Jo, Gyeong-Sik;Kim, Gi-Dong
    • 연구논문집
    • /
    • s.32
    • /
    • pp.65-76
    • /
    • 2002
  • The intensity of x-ray or gamma-ray is attenuated according to density and thickness of the transmitted medium. In this study, by using this principle, on-line real-time radiometric system was developed using a 128 channels linear array of solid state detectors to measure wall thickness of insulated piping system. This system uses a Ir-192 as a gamma ray source and detector is composed of BGO scintillator and photodiode. Ir-192 gamma ray source and linear detector array mounted on a computer controlled robotic crawler. The Ir-192 gamma ray source is located on one side of the piping components and the detector array on the other side. The individual detectors of the detector array measure the intensity of the gamma rays after passing through the walls and the insulation of the piping component under measurement. The output of the detector array is amplified by amplifier and transmitted to the computer. This system collects and analyses the data from the detector array in real-time. The maximum measurable length of pipe is 120cm/mm. in the case of 1mm scanning interval.

  • PDF