• Title/Summary/Keyword: Computer aided diagnosis

Search Result 154, Processing Time 0.024 seconds

Creation of the dental virtual patients with dynamic occlusion and its application in esthetic dentistry (심미치의학 영역에서 동적 교합을 나타내는 가상 환자의 형성을 통한 전치부 보철 수복 증례)

  • An, Se-Jun;Shin, Soo-Yeon;Choi, Yu-Sung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.2
    • /
    • pp.222-230
    • /
    • 2022
  • Digital technology is gradually expanding its field and has a great influence on various fields of dentistry. Recently in digital dentistry, the importance of superimposing various 3-dimensional (3D) image data is emerging, in order to utilize gathered data effectively for diagnosis and prosthesis fabrication. Integrating data from facial scans, intraoral scans, and mandibular movement recordings can create a virtual patient. A virtual patient is formed by integrating digital 3D diagnostic data such as intraoral and extraoral soft tissues, residual dentition, and dynamic occlusion, and the results of prosthetic treatment can be evaluated virtually. The patients in this case report were a 37-year-old female whose chief complaint is that the appearance of the existing prosthesis was distorted and a 55-year-old female patient whose anterior prosthesis needed to be refabricated after the endodontic treatment. 3D facial scans were obtained from each patient, and the patient's mandibular movements were recorded using ARCUS Digma 2 (KaVo Dental GmbH, Biberach an der Riss, Germany). The collected data were integrated on computer-aided design (CAD) software (Exocad dental CAD; exocad GmbH, Darmstadt, Germany) and transferred to a virtual articulator to create a digital virtual patient. The temporary fixed prostheses were designed, restored, and evaluated, and it was reflected into the final restorations. With the aid of the virtual dental patient, accuracy and predictability could be increased throughout treatment, simplifying the occlusal adjustment and clinical evaluation with improved esthetic outcomes.

Full mouth rehabilitation through re-establishment of occlusal plane in partially edentulous patient with reduced vertical dimension accompanied by loss of posterior occlusal support (구치부 교합지지 상실과 수직고경 감소를 동반한 부분 무치악 환자에서 교합평면 회복을 통한 완전구강회복 증례)

  • Cho, Young Eun;Leesungbok, Richard;Lee, Suk Won;Choi, Joseph June Sirk
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.3
    • /
    • pp.263-275
    • /
    • 2022
  • The loss of posterior occlusal support leads to further complications such as collapsed occlusal plane and reduced vertical dimension, and it may cause problems such as facial appearance change, reduced chewing efficiency, and temporomandibular joint disorders. In such case, it is necessary to re-establish occlusal plane and vertical dimension properly through accurate diagnosis and predictable treatment plan. This case report presents a 71-year-old female, whose occlusal plane was collapsed and posterior restorative space was insufficient. To perform a patient-friendly full mouth rehabilitation, proper vertical dimension and occlusal plane were decided by evaluation of interocclusal space at her physiologic mandibular rest position, swallowing, pronunciation, facial appearance, and the average length of anterior teeth. And then, the fixed provisional restorations were fabricated with the new occlusal position, and evaluated for 5 months with checking adaptation of masticatory muscles and any kind of clinical symptoms occurs or not. After confirmation of functional stability and esthetic satisfaction with the newly established occlusion, final definitive restorations were fabricated and inserted in the mouth. Through the above process, the treatment result was functionally and aesthetically satisfactory.

Development of Graphical Solution for Computer-Assisted Fault Diagnosis: Preliminary Study (컴퓨터 원용 결함진단을 위한 그래픽 솔루션 개발에 관한 연구)

  • Yoon, Han-Bean;Yun, Seung-Man;Han, Jong-Chul;Cho, Min-Kook;Lim, Chang-Hwy;Heo, Sung-Kyn;Shon, Cheol-Soon;Kim, Seong-Sik;Lee, Seok-Hee;Lee, Suk;Kim, Ho-Koung
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.29 no.1
    • /
    • pp.36-42
    • /
    • 2009
  • We have developed software for converting the volumetric voxel data obtained from X-ray computed tomography(CT) into computer-aided design(CAD) data. The developed software can used for non-destructive testing and evaluation, reverse engineering, and rapid prototyping, etc. The main algorithms employed in the software are image reconstruction, volume rendering, segmentation, and mesh data generation. The feasibility of the developed software is demonstrated with the CT data of human maxilla and mandible bones.

Effect of scanning strategies on the accuracy of digital intraoral scanners: a meta-analysis of in vitro studies

  • Louis Hardan;Rim Bourgi;Monika Lukomska-Szymanska;Juan Carlos Hernandez-Cabanillas;Juan Eliezer Zamarripa-Calderon;Gilbert Jorquera;Sinan Ghishan;Carlos Enrique Cuevas-Suarez
    • The Journal of Advanced Prosthodontics
    • /
    • v.15 no.6
    • /
    • pp.315-332
    • /
    • 2023
  • PURPOSE. This study aimed to investigate whether the accuracy of intraoral scanners is influenced by different scanning strategies in an in vitro setting, through a systematic review and meta-analysis. MATERIALS AND METHODS. This review was conducted in accordance with the PRISMA 2020 standard. The following PICOS approach was used: population, tooth impressions; intervention, the use of intraoral scanners with scanning strategies different from the manufacturer's instructions; control, the use of intraoral scanners following the manufacturers' requirements; outcome, accuracy of intraoral scanners; type of studies, in vitro. A comprehensive literature search was conducted across various databases including Embase, SciELO, PubMed, Scopus, and Web of Science. The inclusion criteria were based on in vitro studies that reported the accuracy of digital impressions using intraoral scanners. Analysis was performed using Review Manager software (version 5.3.5; Cochrane Collaboration, Copenhagen, Denmark). Global comparisons were made using a standardized mean difference based on random-effect models, with a significance level of α = 0.05. RESULTS. The meta-analysis included 15 articles. Digital impression accuracy significantly improved under dry conditions (P < 0.001). Moreover, trueness and precision were enhanced when artificial landmarks were used (P ≤ 0.02) and when an S-shaped pattern was followed (P ≤ 0.01). However, the type of light used did not have a significant impact on the accuracy of the digital intraoral scanners (P ≥ 0.16). CONCLUSION. The accuracy of digital intraoral scanners can be enhanced by employing scanning processes using artificial landmarks and digital impressions under dry conditions.

Recognition for Lung Cancer using PCA in the Digital Chest Radiography (디지털 흉부영상에서 주성분분석을 이용한 폐암인식)

  • Park, Hyung-Hu;Ok, Chi-Sang;Kang, Se-Sik;Ko, Sung-Jin;Choi, Seok-Yoon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.15 no.7
    • /
    • pp.1573-1582
    • /
    • 2011
  • Risk of lung cancer among lung-related diseases has gradually increased during last decades. The chest digital radiography is the primary diagnosis method for lung cancer. Diagnosing lung cancer using this method requires doctors of ripe experience. Despite their experience there are often wrong diagnoses, which decrease early diagnosis and survival rates of patients. The aim of this study was intended to establish the base on the Computer Aided Diagnosis (CAD) by analyzing Image Recognition Algorithm using Principle component Analysis (PCA) and diagnosing patient's chest X-ray image. The database obtained through this approach enables a doctor to significantly reduce misdiagnosis during the early diagnosis stage, if he or she utilizes it as the preliminary reading step. Case studies were carried out using normal organ, and organs suffering from bronchogenic carcinoma and granuloma. A normal image and unique disease images were extracted after PCA analysis, and their cross-recognition efficiency were compared each other. The result revealed that the recognition rate was much high between normal and disease images, but relatively low between two disease images. In order to increase the recognition efficiency among chest diseases the related algorithms have to be developed continuously in the future study, and such effort will establish the resolute base for CAD.

Development of Automatic Cluster Algorithm for Microcalcification in Digital Mammography (디지털 유방영상에서 미세석회화의 자동군집화 기법 개발)

  • Choi, Seok-Yoon;Kim, Chang-Soo
    • Journal of radiological science and technology
    • /
    • v.32 no.1
    • /
    • pp.45-52
    • /
    • 2009
  • Digital Mammography is an efficient imaging technique for the detection and diagnosis of breast pathological disorders. Six mammographic criteria such as number of cluster, number, size, extent and morphologic shape of microcalcification, and presence of mass, were reviewed and correlation with pathologic diagnosis were evaluated. It is very important to find breast cancer early when treatment can reduce deaths from breast cancer and breast incision. In screening breast cancer, mammography is typically used to view the internal organization. Clusterig microcalcifications on mammography represent an important feature of breast mass, especially that of intraductal carcinoma. Because microcalcification has high correlation with breast cancer, a cluster of a microcalcification can be very helpful for the clinical doctor to predict breast cancer. For this study, three steps of quantitative evaluation are proposed : DoG filter, adaptive thresholding, Expectation maximization. Through the proposed algorithm, each cluster in the distribution of microcalcification was able to measure the number calcification and length of cluster also can be used to automatically diagnose breast cancer as indicators of the primary diagnosis.

  • PDF

3D Generic Vertebra Model for Computer Aided Diagnosis (컴퓨터를 이용한 의료 진단용 3차원 척추 제네릭 모델)

  • Lee, Ju-Sung;Baek, Seung-Yeob;Lee, Kun-Woo
    • Korean Journal of Computational Design and Engineering
    • /
    • v.15 no.4
    • /
    • pp.297-305
    • /
    • 2010
  • Medical image acquisition techniques such as CT and MRI have disadvantages in that the numerous time and efforts are needed. Furthermore, a great amount of radiation exposure is an inherent proberty of the CT imaging technique, a number of side-effects are expected from such method. To improve such conventional methods, a number of novel methods that can obtain 3D medical images from a few X-ray images, such as algebraic reconstruction technique (ART), have been developed. Such methods deform a generic model of the internal body part and fit them into the X-ray images to obtain the 3D model; the initial shape, therefore, affects the entire fitting process in a great deal. From this fact, we propose a novel method that can generate a 3D vertebraic generic model based on the statistical database of CT scans in this study. Moreover, we also discuss a method to generate patient-tailored generic model using the facts obtained from the statistical analysis. To do so, the mesh topologies of CT-scanned 3D vertebra models are modified to be identical to each other, and the database is constructed based on them. Furthermore, from the results of a statistical analysis on the database, the tendency of shape distribution is characterized, and the modeling parameters are extracted. By using these modeling parameters for generating the patient-tailored generic model, the computational speed and accuracy of ART can greatly be improved. Furthermore, although this study only includes an application to the C1 (Atlas) vertebra, the entire framework of our method can be applied to other body parts generally. Therefore, it is expected that the proposed method can benefit the various medical imaging applications.

A study on the digital image transfer application mass chest X-ray system up-grade (간접촬영기의 디지털 영상 변환 장치 적용에 대한 연구)

  • Kim, Sun-Chil;Park, Jong-Sam;Lee, Jon-Il
    • Journal of radiological science and technology
    • /
    • v.26 no.3
    • /
    • pp.13-17
    • /
    • 2003
  • By converting movable indirect mass chest X-ray devices for vehicles into digital systems and upgrading it to share information with the hospital's medical image information system, excellencies have been confirmed as a result of installing and running this type of system and are listed hereinafter. 1. Upgrading analog systems, such as indirect mass chest X-ray devices dependent on printed film, to digital systems allows them to be run and managed much more efficiently, contributing to the increase in the stability and the efficiency of the system. 2. Unlike existing images, communication based on DICOM standards allow images to be compatible with the hospital's outer and inner network PACS systems, extending the scope of the radiation departments information system. 3. Assuming chest-exclusive indirect mass chest X-rays, a linked development of CAD (Computer Aided Diagnosis, Detector) becomes possible. 4. By applying wireless Internet, Web-PACS for movable indirect mass chest X-ray devices for vehicles will become possible. Research in these fields must continue and if the superior image quality and convenience of digital systems are confirmed, I believe that the conversion of systems still dependent on analog images to modernized digital systems is a must.

  • PDF

Segmentation of Liver Regions in the Abdominal CT Image by Multi-threshold and Watershed Algorithm

  • Kim, Pil-Un;Lee, Yun-Jung;Kim, Gyu-Dong;Jung, Young-Jin;Cho, Jin-Ho;Chang, Yong-Min;Kim, Myoung-Nam
    • Journal of Korea Multimedia Society
    • /
    • v.9 no.12
    • /
    • pp.1588-1595
    • /
    • 2006
  • In this paper, we proposed a liver extracting procedure for computer aided liver diagnosis system. Extraction of liver region in an abdominal CT image is difficult due to interferences of other organs. For this reason, liver region is extracted in a region of interest(ROI). ROI is selected by the window which can measure the distribution of Hounsfield Unit(HU) value of liver region in an abdominal CT image. The distribution is measured by an existential probability of HU value of lever region in the window. If the probability of any window is over 50%, the center point of the window would be assigned to ROI. Actually, liver region is not clearly discerned from the adjacent organs like muscle, spleen, and pancreas in an abdominal CT image. Liver region is extracted by the watershed segmentation algorithm which is effective in this situation. Because it is very sensitive to the slight valiance of contrast, it generally produces over segmentation regions. Therefore these regions are required to merge into the significant regions for optimal segmentation. Finally, a liver region can be selected and extracted by prier information based on anatomic information.

  • PDF

Automatic Liver Segmentation Method on MR Images using Normalized Gradient Magnitude Image (MR 영상에서 정규화된 기울기 크기 영상을 이용한 자동 간 분할 기법)

  • Lee, Jeong-Jin;Kim, Kyoung-Won;Lee, Ho
    • Journal of Korea Multimedia Society
    • /
    • v.13 no.11
    • /
    • pp.1698-1705
    • /
    • 2010
  • In this paper, we propose a fast liver segmentation method from magnetic resonance(MR) images. Our method efficiently divides a MR image into a set of discrete objects, and boundaries based on the normalized gradient magnitude information. Then, the objects belonging to the liver are detected by using 2D seeded region growing with seed points, which are extracted from the segmented liver region of the slice immediately above or below the current slice. Finally, rolling ball algorithm, and connected component analysis minimizes false positive error near the liver boundaries. Our method was validated by twenty data sets and the results were compared with the manually segmented result. The average volumetric overlap error was 5.2%, and average absolute volumetric measurement error was 1.9%. The average processing time for segmenting one data set was about three seconds. Our method could be used for computer-aided liver diagnosis, which requires a fast and accurate segmentation of liver.