Loading [MathJax]/jax/output/CommonHTML/jax.js
  • Title/Summary/Keyword: Computer System

Search Result 32,404, Processing Time 0.057 seconds

Study on image quality improvement using Non-Linear Look-Up Table (비선형 Look-Up Table을 통한 영상 화질 개선에 관한 연구)

  • Kim, Sun-Chil;Lee, Jun-Il
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.5 no.1
    • /
    • pp.32-44
    • /
    • 2002
  • The role of radiology department has been greatly increased in the past few years as the technology in the medical imaging devices improved and the introduction of PACS (Picture Archiving and Communications System) to the conventional film-based diagnostic structure is a truly remarkable factor to the medical history. In addition, the value of using digital information in medical imaging is highly expected to grow as the technology over the computer and the network improves. However, the current medical practice, using PACS is somewhat limited compared to the film-based conventional one due to a poor image quality. The image quality is the most important and inevitable factor in the PACS environment and it is one of the most necessary steps to more wide practice of digital imaging. The existing image quality control tools are limited in controlling images produced from the medical modalities, because they cannot display the real image changing status. Thus, the image quality is distorted and the ability to diagnosis becomes hindered compared to the one of the film-based practice. In addition, the workflow of the radiologist greatly increases; as every doctor has to perform his or her own image quality control every time they view images produced from the medical modalities. To resolve these kinds of problems and enhance current medical practice under the PACS environment, we have developed a program to display a better image quality by using the ROI optical density of the existing gray level values. When the LUT is used properly, small detailed regions, which cannot be seen by using the existing image quality controls are easily displayed and thus, greatly improves digital medical practice. The purpose of this study is to provide an easier medical practice to physicians, by applying the technology of converting the H-D curves of the analog film screen to the digital imaging technology and to preset image quality control values to each exposed body part, modality and group of physicians for a better and easier medical practice. We have asked to 5 well known professional physicians to compare image quality of the same set of exam by using the two different methods: existing image quality control and the LUT technology. As the result, the LUT technology was enormously favored over the existing image quality control method. All the physicians have pointed out the far more superiority of the LUT over the existing image quality control method and highly praised its ability to display small detailed regions, which cannot be displayed by existing image quality control tools. Two physicians expressed the necessity of presetting the LUT values for each exposed body part. Overall, the LUT technology yielded a great interest among the physicians and highly praised for its ability to overcome currently embedded problems of PACS. We strongly believe that the LUT technology can enhance the current medical practice and open a new beginning in the future medical imaging.

  • PDF

A Study on Combustion Experiments of Multi Type Air-Conditioner Outdoor Units by Large Scale Calorimeter (라지스케일 칼로리미터에 의한 멀티시스템형 에어컨실외기의 연소실험에 관한 연구)

  • Min, Se-Hong;Bae, Yeon-Jun
    • Fire Science and Engineering
    • /
    • v.25 no.6
    • /
    • pp.168-177
    • /
    • 2011
  • The combustion test for real box of AC outdoor unit has been performed in this study in order to estimate the fire hazard in multi-system type of AC outdoor unit which is currently used for commercial use. The result showed that in test, there was explosion inside of AC outdoor unit, and flame erupted and fire spread through upper side grill. And then this fire burnt the combustibles such as wires, electronic control board, heat exchange copper plate and plastics etc inside the unit, refrigerant gas pipe was burst due to fire, and accelerated the explosion and flame eruption to outside while the refrigerant was erupting. It is found in this test that the maximum heat release rate of AC outdoor unit is 5,830 kW, the maximum internal temperature measured with infrared camera and thermocouple is 1,201C, maximum ambient temperature is 881C, and flame rose higher than about 5 m. It is concluded that the fire in AC outdoor unit cause fire to combustibles around the unit, and may give big damage by generating the secondary fire. It is expected that the result obtained from the test on the real object may be applied to fire realization of AC outdoor unit and estimation of fire spreading to the combustibles around in the future computer simulation.

A Survey on the Performance-based Design Status of Fire-fighting Facilities through the Whole Design Drawings and Specifications (설계도서 전수조사를 통한 소방시설분야 성능위주설계 현황조사)

  • Jeon, Eun-Goo;Bae, Young-Hoon;An, Sung-Ho;Hwang, Cheol-Hong;Hong, Won-Hwa;Choi, Jun-Ho
    • Fire Science and Engineering
    • /
    • v.33 no.5
    • /
    • pp.155-162
    • /
    • 2019
  • In Korea, the relevant laws and regulations for fire safety in buildings have been revised. Since 2011, Performance-based Design has been conducted for large-scale or high-rise buildings. However, the Korea's performance-based design is still at a level where life safety evaluation using fire and evacuation simulation tools is compared with existing methods. Although related studies have been conducted continuously for the mandatory performance-based design, the fact that it is relatively unsatisfactory for design and construction of fire-fighting facilities as it mainly focuses on administrative and institutional improvement measures or computer simulation. This study collected 91 performance-based design documents that were carried out nationwide at the initial stage of implementation until 2016 to analyze the status of performance-based design of fire-fighting facilities. As a result, fire-fighting facilities, except for fire extinguish system facilities, were not properly designed for performance. Furthermore, the designers found that if corresponding facilities or higher-level equipment with upgraded performance is additionally installed, the performance-based design fared well compared to the existing the prescriptive-based design.

Characterization of Secondary Exposure to Chemicals and Indoor Air Quality in Fire Station (소방서 실내공간의 화학적 유해인자 2차노출과 실내공기질 특성)

  • Kim, Soo Jin;Ham, Seunghon;Jeon, Jeong Seok;Kim, Won
    • Fire Science and Engineering
    • /
    • v.33 no.4
    • /
    • pp.140-151
    • /
    • 2019
  • It is to assess the indoor air quality of the chemical hazardous materials exposed to the fire after firefighters returned to the fire scene. The research subject randomly selected four fire stations located in Seoul, Korea. Two fire stations were set up as control groups after the return of the firefighting activities at the actual fire scene, and two other fire stations were set up as control groups to measure the air quality of the room at normal levels regardless of the action. We conducted 24-hour monitoring for all fire accidents that occurred in Seoul Metropolitan using fire safety map computer system. Also, indoor air quality was measured immediately after homecoming if the experiment group was to be dispatched due to an accident of intermediate or larger scale. 11 hazardous substance items such as fine dust, formaldehyde, volatile organic compounds, PAH, VCM, acidity, asbestos, CO2, NO2, O3 were measured according to the process test method. Three of 11 types of harmful substances exceeded domestic and foreign standards, and one of them was found to be close to foreign standards. In particular, total volatile organic compounds, carbon dioxide and sulfuric acids were 2.5 times, 2.2 times and 1.1 times higher than the standard. Also, for formaldehyde and sulfuric acid, it was measured higher in the control group than in the case group. This findings could be used in policies to improve indoor air quality in the fire station of the Seoul Metropolitan Government.

An APK Overwrite Scheme for Preventing Modification of Android Applications (안드로이드 앱 변조 방지를 위한 APK 덮어쓰기 기법)

  • Choi, Byungha;Shim, HyungJoon;Lee, ChanHee;Cho, Sangwook;Cho, Seong-Je
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.39B no.5
    • /
    • pp.309-316
    • /
    • 2014
  • It is easy to reverse engineer an Android app package file(APK) and get its decompiled source code. Therefore, attackers obtains economic benefits by illegally using the decompiled source code, or modifies an app by inserting malware. To address these problems in Android, we propose an APK overwrite scheme that protects apps against illegal modification of themselves by using a new anti-reverse engineering technique. In this paper, the targets are the apps which have been written by any programmer. For a target app (original app), server system (1) makes a copy of a target app, (2) encrypts the target app, (3) creates a stub app by replacing the DEX (Dalvik Executable) of the copied version with our stub DEX, and then (4) distributes the stub app as well as the encrypted target app to users of smartphones. The users downloads both the encrypted target app and the corresponding stub app. Whenever the stub app is executed on smartphones, the stub app and our launcher app decrypt the encrypted target app, overwrite the stub app with the decrypted target one, and executes the decrypted one. Every time the target app ends its execution, the decrypted app is deleted. To verify the feasibility of the proposed scheme, experimentation with several popular apps are carried out. The results of the experiment demonstrate that our scheme is effective for preventing reverse engineering and tampering of Android apps.

3D Digital Design Optimization Process Considering Constructability of Freeform Structure (비정형 구조물의 시공성을 고려한 3차원 디지털 설계 최적화 프로세스)

  • Ryu, Han-Guk
    • Korean Journal of Construction Engineering and Management
    • /
    • v.14 no.5
    • /
    • pp.35-43
    • /
    • 2013
  • Nowadays the widely used media in architecture include visualizations, animations and three-dimensional models. 3D digital methods using active CAM(Computer Aided Manufacturing) and CNC(Computerized Numerical Control) imaging have been developed for accurate shape and 3D measurements in freeform buildings. In contrast to a conventional building using auto CAD system and others, the proposed digital optimization method is based on a combination of 3D numerical data and parametric 3D model for design and construction. The objective of this paper is therefore to present digital optimization process for constructability of freeform building. The method can be useful in the effective implementation of an error-proofing process of freeform building during design and construction phase. 3D digital coordinate data can be used effectively to identify correct size of structural and finish members and installation location of each members in construction field. In addition, architects, engineers and contractors can evaluate design, materials, constructability and identify error-proofing opportunities. Other project participants can also include representatives from all levels of management, departments as well as workers and key subcontractors' personnel, if necessary. The 3D digital optimization process is therefore appropriate to serious variations in freeform shape. For future study, the developed digital optimization method is necessary to be carried out to verify the robustness and accuracy for constructability in construction field.

Re-ranking the Results from Two Image Retrieval System in Cooperative Manner (두 영상검색 시스템의 협력적 이용을 통한 재순위화)

  • Hwang, Joong-Won;Kim, Hyunwoo;Kim, Junmo
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.24 no.1
    • /
    • pp.7-15
    • /
    • 2014
  • Image retrieval has become a huge part of computer vision and data mining. Although commercial image retrieval systems such as Google show great performances, the improvement on the performances are constantly on demand because of the rapid growth of data on web space. To satisfy the demand, many re-ranking methods, which enhance the performances by reordering retrieved results with independent algorithms, has been proposed. Conventional re-ranking algorithms are based on the assumption that visual patterns are not used on initial image retrieval stage. However, image search engines in present have begun to use the visual and the assumption is required to be reconsidered. Also, though it is possible to suspect that integration of multiple retrieval systems can improve the overall performance, the research on the topic has not been done sufficiently. In this paper, we made the condition that other manner than cooperation cannot improve the ranking result. We evaluate the algorithm on toy model and show that propose module can improve the retrieval results.

Geocoding Scheme for Multimedia in Indoor Space Based on IndoorGML (IndoorGML을 활용한 실내공간 멀티미디어 위치 인코딩 방법)

  • Li, Ki Joune
    • Spatial Information Research
    • /
    • v.21 no.4
    • /
    • pp.35-45
    • /
    • 2013
  • Most multimedia contains location information whether they are implicit or explicitly, and which are very useful for several purposes. In particular, we may use location information in defining query conditions to retrieve relevant multimedia. For this reason, a number of works have been done to organize and retrieve geo-referenced multimedia data. However, they mostly focus on outdoor space where position is identified by (x, y, z) coordinates. In this paper, we focus on multimedia in an alternative space, indoor space, which differs from outdoor space in several aspects. First indoor space is considered as symbolic space, where location is identified by a symbolic code such as room number rather than coordinates. Second, topological information is a crucial element in providing indoor spatial information services. Third, indoor space is in more micro-scale than outdoor space, which influences on determining the visibility of cameras. Based on these different characteristics of indoor space, we survey the requirements of management systems of indoor geo-referenced multimedia. Then we propose a geo-coding scheme for multimedia in indoor space as an extension of IndoorGML, an OGC(Open Geospatial Consortium) candidate standard for indoor spatial information. We also present a prototype system called, IngC (INdoor Geo-Coding) developed to store and manage indoor geo-referenced multimedia.

Design of Dynamic Buffer Assignment and Message model for Large-scale Process Monitoring of Personalized Health Data (개인화된 건강 데이터의 대량 처리 모니터링을 위한 메시지 모델 및 동적 버퍼 할당 설계)

  • Jeon, Young-Jun;Hwang, Hee-Joung
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.15 no.6
    • /
    • pp.187-193
    • /
    • 2015
  • The ICT healing platform sets a couple of goals including preventing chronic diseases and sending out early disease warnings based on personal information such as bio-signals and life habits. The 2-step open system(TOS) had a relay designed between the healing platform and the storage of personal health data. It also took into account a publish/subscribe(pub/sub) service based on large-scale connections to transmit(monitor) the data processing process in real time. In the early design of TOS pub/sub, however, the same buffers were allocated regardless of connection idling and type of message in order to encode connection messages into a deflate algorithm. Proposed in this study, the dynamic buffer allocation was performed as follows: the message transmission type of each connection was first put to queuing; each queue was extracted for its feature, computed, and converted into vector through tf-idf, then being entered into a k-means cluster and forming a cluster; connections categorized under a certain cluster would re-allocate the resources according to the resource table of the cluster; the centroid of each cluster would select a queuing pattern to represent the cluster in advance and present it as a resource reference table(encoding efficiency by the buffer sizes); and the proposed design would perform trade-off between the calculation resources and the network bandwidth for cluster and feature calculations to efficiently allocate the encoding buffer resources of TOS to the network connections, thus contributing to the increased tps(number of real-time data processing and monitoring connections per unit hour) of TOS.

Convergence Speed Improvement in MMA Algorithm by Serial Connection of Two Stage Adaptive Equalizer (2단 적응 등화기의 직렬 연결에 의한 MMA 알고리즘의 수렴 속도 개선)

  • Lim, Seung-Gag
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.15 no.3
    • /
    • pp.99-105
    • /
    • 2015
  • This paper deals with the mMMA (modified MMA) which possible to improving the convergence speed that employing the serial connecting form of two stage digital filter instead of signal filter of MMA adaptive equalizer without applying the variable step size for compensates the intersymbol interference by channel distortion in the nonconstant modulus signal. The adaptive equalizer can be implemented by signal digital filter using the finite order tap delay line. In this paper, the equalizer is implemented by the two stage serial form and the filter coefficient are updated by the error signal using the same algorithm of MMA in each stage. The fast convergence speed is determined in the first stage, and the residual isi left at the output of first stage output is minimized in the second stage filter. The same digital filter length was considered in single stage and two stage system and the performance of these systems were compared. The performance index includes the output signal constellation, the residual isi and maximum distortion, MSE that is measure of the convergence characteristics, the SER. As a result of computer simulation, mMMA that has a FIR structure of two stage, has more good performance in every performance index except the constellation diagram due to equalization noise and improves the convergence speed about 1.5~1.8 time than the present MMA that has a FIR structure of single stage.