• 제목/요약/키워드: Computed tomography perfusion imaging

검색결과 62건 처리시간 0.022초

CT Fractional Flow Reserve for the Diagnosis of Myocardial Bridging-Related Ischemia: A Study Using Dynamic CT Myocardial Perfusion Imaging as a Reference Standard

  • Yarong Yu;Lihua Yu;Xu Dai;Jiayin Zhang
    • Korean Journal of Radiology
    • /
    • 제22권12호
    • /
    • pp.1964-1973
    • /
    • 2021
  • Objective: To investigate the diagnostic performance of CT fractional flow reserve (CT-FFR) for myocardial bridging-related ischemia using dynamic CT myocardial perfusion imaging (CT-MPI) as a reference standard. Materials and Methods: Dynamic CT-MPI and coronary CT angiography (CCTA) data obtained from 498 symptomatic patients were retrospectively reviewed. Seventy-five patients (mean age ± standard deviation, 62.7 ± 13.2 years; 48 males) who showed myocardial bridging in the left anterior descending artery without concomitant obstructive stenosis on the imaging were included. The change in CT-FFR across myocardial bridging (ΔCT-FFR, defined as the difference in CT-FFR values between the proximal and distal ends of the myocardial bridging) in different cardiac phases, as well as other anatomical parameters, were measured to evaluate their performance for diagnosing myocardial bridging-related myocardial ischemia using dynamic CT-MPI as the reference standard (myocardial blood flow < 100 mL/100 mL/min or myocardial blood flow ratio ≤ 0.8). Results: ΔCT-FFRsystolic (ΔCT-FFR calculated in the best systolic phase) was higher in patients with vs. without myocardial bridging-related myocardial ischemia (median [interquartile range], 0.12 [0.08-0.17] vs. 0.04 [0.01-0.07], p < 0.001), while CT-FFRsystolic (CT-FFR distal to the myocardial bridging calculated in the best systolic phase) was lower (0.85 [0.81-0.89] vs. 0.91 [0.88-0.96], p = 0.043). In contrast, ΔCT-FFRdiastolic (ΔCT-FFR calculated in the best diastolic phase) and CT-FFRdiastolic (CT-FFR distal to the myocardial bridging calculated in the best diastolic phase) did not differ significantly. Receiver operating characteristic curve analysis showed that ΔCT-FFRsystolic had largest area under the curve (0.822; 95% confidence interval, 0.717-0.901) for identifying myocardial bridging-related ischemia. ΔCT-FFRsystolic had the highest sensitivity (91.7%) and negative predictive value (NPV) (97.8%). ΔCT-FFRdiastolic had the highest specificity (85.7%) for diagnosing myocardial bridging-related ischemia. The positive predictive values of all CT-related parameters were low. Conclusion: ΔCT-FFRsystolic reliably excluded myocardial bridging-related ischemia with high sensitivity and NPV. Myocardial bridging showing positive CT-FFR results requires further evaluation.

혈관 수술 후 심장 합병증 발생을 예측하기 위한 선별 검사로서 심근 관류 단일 광자 단층촬영의 유용성에 대한 연구 (Myocardial Perfusion SPECT as a Screening Test before Planned Vascular Surgery for Predicting Perioperative Cardiac Complications)

  • 이형채;황윤호;위진홍;전희재;이양행;조광현
    • Journal of Chest Surgery
    • /
    • 제43권1호
    • /
    • pp.25-32
    • /
    • 2010
  • 배경: 혈관질환 환자는 관상동맥질환 및 심장질환을 많이 동반함으로 인하여 혈관 수술 후 잠재되어 있는 심장질환이 악화 또는 유발될 수 있는 가능성이 있다. 이러한 심장질환을 확인하기 위한 검사중 비교적 간단하고 비침습적인 SPECT 촬영에 대한 효용성은 아직 논란이 되고 있다. 본 연구에서는 수술 전 SPECT를 촬영하고, 그 결과에 따른 검사 및 처치들이 혈관 수술 후 심장 합병증 발생에 미치는 임상적인 효과를 평가하고자 한다. 대상 및 방법: 2004년 4월부터 2007년 9월까지 3년 6개월간 본 병원에서 혈관 수술 전 아데노신 부하 Tc-99m 테트로포스민 SPECT를 촬영한 63명의 환자를 대상으로 하였다. 결과: SPECT 촬영 유소견의 심장 합병증 발생 예측에 대한 민감도와 특이도는 각각 41.2%와 52.2%로 비교적 낮게 나왔다. 그러나 비정상적인 SPECT 촬영결과를 보인 환자에게 관상동맥 조영술을 시행하고 관상동맥 병변에 대한 비정상 소견이 있을 때 관상동맥 중재적 시술 및 관상동맥 우회로술 등의 적극적인 처치를 한 경우 심장 합병증의 발생률이 낮은 경향을 보였다. 결론: SPECT 촬영은 혈관수술 후 심장 합병증 발생위험을 예측하기 위한 선별검사로서 효용성이 떨어진다.

Angiogenic factor-enriched platelet-rich plasma enhances in vivo bone formation around alloplastic graft material

  • Kim, Eun-Seok;Kim, Jae-Jin;Park, Eun-Jin
    • The Journal of Advanced Prosthodontics
    • /
    • 제2권1호
    • /
    • pp.7-13
    • /
    • 2010
  • Although most researchers agree that platelet-rich plasma (PRP) is a good source of autogenous growth factors, its effect on bone regeneration is still controversial. The purpose of this study was to evaluate whether increasing angiogenic factors in the human PRP to enhance new bone formation through rapid angiogenesis. MATERIAL AND METHODS. In vitro, the human platelets were activated with application of shear stress, $20\;{\mu}g/ml$ collagen, 2 mM $CaCl_2$ and 10U thrombin/$1\;{\times}\;10^9$ platelets. Level of vascular endothelial growth factor (VEGF) and platelet microparticle (PMP) in the activated platelets were checked. In the animal study, human angiogenic factors-enriched PRP was tested in 28 athymic rat's cranial critical bone defects with $\beta$-TCP. Angiogenesis and osteogenesis were evaluated by laser Doppler perfusion imaging, histology, dual energy X-ray densinometry, and micro-computed tomography. RESULTS. In vitro, this human angiogenic factors-enriched PRP resulted in better cellular proliferation and osteogenic differentiation. In vivo, increasing angiogenic potential of the PRP showed significantly higher blood perfusion around the defect and enhanced new bone formation around acellular bone graft material. CONCLUSION. Angiogenic factor-enriched PRP leads to faster and more extensive new bone formation in the critical size bone defect. The results implicate that rapid angiogenesis in the initial healing period by PRP could be supposed as a way to overcome short term effect of the rapid angiogenesis.

컴퓨터단층 혈관조영술에서 스텐트 사이즈의 정확한 측정을 위한 상대적 측정법의 기초연구 (Fundamental Study of Relative Measurement for Accurate Measurement of Stent Size in Computed Tomography Angiography)

  • 이승영;홍주완;강수미;김수빈;전상훈;허영철
    • 한국방사선학회논문지
    • /
    • 제13권5호
    • /
    • pp.713-720
    • /
    • 2019
  • 본 연구의 목적은 컴퓨터단층 혈관조영술에서 혈관 직경을 정확하게 측정할 수 있는 새로운 측정 방법인 상대적 측정법의 기초연구 자료를 제공하고자 한다. 비이온성 요오드 조영제를 자체 제작한 관류 팬텀에 일정한 속도로 흐르게 한 후 컴퓨터단층 혈관조영술 검사를 시행하였다. 원시 데이터를 얻은 후 다중평면재구성 및 최대강도투사법으로 영상을 재구성하였고 장비 사에서 제공하는 거리측정 장치를 사용하여 팬텀의 직경을 측정하였다. 측정법은 고식적 측정법과 본 연구에서 제안하는 상대적 측정법을 사용하였다. 관류팬텀의 평균 직경은 다중평면재구성기법과 최대강도투사법 모두에서 상대적 측정법이 기존 측정법 보다 실측에 더 가깝게 나타났다(34% VS 24%, p<0.05). 하지만 두 가지 측정법 모두 실측보다 여전히 확대된 결과를 나타내고 있음을 확인하였다. 따라서 상대적 측정 방법에 대한 추가 연구가 필요한 실정이며, 이에 본 연구가 기초 자료를 제공할 수 있을 것이라 사료된다.

Early Detection of hyperemia with Magnetic Resonance Fluid Attenuation Inversion Recovery Imaging after Superficial Temporal Artery to Middle Cerebral Artery Anastomosis

  • Jin Eun;Ik Seong Park
    • Journal of Korean Neurosurgical Society
    • /
    • 제67권4호
    • /
    • pp.442-450
    • /
    • 2024
  • Objective : Cerebral hyperperfusion syndrome (CHS) manifests as a collection of symptoms brought on by heightened focal cerebral blood flow (CBF), afflicting nearly 30% of patients who have undergone superficial temporal artery (STA)-middle cerebral artery (MCA) anastomosis. The aim of this study was to investigate whether the amalgamation of magnetic resonance imaging (MRI) fluid-attenuated inversion recovery (FLAIR) and apparent diffusion coefficient (ADC) imaging via MRI can discern cerebral hyperemia after STA-MCA anastomosis surgery. Methods : A retrospective study was performed of patients who underwent STA-MCA anastomosis due to Moyamoya disease or atherosclerotic steno-occlusive disease. A protocol aimed at preventing CHS was instituted, leveraging the use of MRI FLAIR. Patients underwent MRI diffusion with FLAIR imaging 24 hours after STA-MCA anastomosis. A high signal on FLAIR images signified the presence of hyperemia at the bypass site, triggering a protocol of hyperemia care. All patients underwent hemodynamic evaluations, including perfusion MRI, single-photon emission computed tomography (SPECT), and digital subtraction angiography, both before and after the surgery. If a high signal intensity is observed on MRI FLAIR within 24 hours of the surgery, a repeat MRI is performed to confirm the presence of hyperemia. Patients with confirmed hyperemia are managed according to a protocol aimed at preventing further progression. Results : Out of a total of 162 patients, 24 individuals (comprising 16 women and 8 men) exhibited hyperemia on their MRI FLAIR scans following the procedure. SPECT was conducted on 23 patients, and 11 of them yielded positive results. All 24 patients underwent perfusion MRI, but nine of them showed no significant findings. Among the patients, 10 displayed elevations in both CBF and cerebral blood volume (CBV), three only showed elevation in CBF, and two only showed elevation in CBV. Follow-up MRI FLAIR scans conducted 6 months later on these patients revealed complete normalization of the previously observed high signal intensity, with no evidence of ischemic injury. Conclusion : The study determined that the use of MRI FLAIR and ADC mapping is a competent means of early detection of hyperemia after STA-MCA anastomosis surgery. The protocol established can be adopted by other neurosurgical institutions to enhance patient outcomes and mitigate the hazard of permanent cerebral injury caused by cerebral hyperemia.

급성 심근경색 환자의 Tc-99m Tetrofosmin 심근 관류 지연영상에서 관찰되는 역재분포 현상의 임상적 의의 (Clinical Significance of Reverse Redistribution Phenomenon on Delayed Tc-99m Tetrofosmin Myocardial Perfusion Imaging in Patients with Acute Myocardial Infarction)

  • 박순아;김대응;김창근;정진원;김남호;김경호
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제43권2호
    • /
    • pp.112-119
    • /
    • 2009
  • 목적: Tc-99m tetrofosmin은 일반적으로 재분포 하지 않는 것으로 알려져 있으나 최근 일부 연구에서 Tc-99m tetrofomin의 재분포 현상이 보고 되고 있다. 본 연구는 재관류 치료를 받은 급성 심근경색 환자의 Tc-99m tetrofosmin 심근 관류 지연영상에서 역재분포 현상을 관찰하고 이에 대한 정량분석 및 추적 검사를 통해 역재분포 현상의 임상적 의의에 대하여 알아보고자 하였다. 대상 및 방법: 급성 심근경색으로 관동맥 중재술을 시행한 67명(남자 46명, 여자 21명, 평균연령 $62{\pm}12.9$세)을 대상으로 게이트 Tc-99m tetrofosmin SPECT영상을 얻었다. 휴식기 조기 영상은 주사 후 40분째 얻었고 부하 후 지연기 영상은 3시간째 촬영하였다. 심근은 단축 영상을 주로 하여17개 분절로 나누어 분석하였고 심근의 혈류감소 정도와 범위, 국소심근벽 운동, 심근벽 두께는 단축 영상을 주로 하여 정상에서 결손까지 4등급으로 분류하여 분절 점수를 매겼다(0: 정상, 1: 약간 감소, 2: 심한 감소, 3: 결손). 조기 영상을 지연기 영상과 비교하여 지연기 영상에서 2점 이상으로 악화되는 분절을 역재분포가 있는 분절로 정의하였다. 대상 환자들은 9개월 후 관동맥 조영술과 게이트 Tc-99m tetrofosmin 심근 관류를 시행하였으며 역재분포가 있었던 경우와 없었던 경우로 나누어 관동맥 재협착 유무와 심근의 혈류감소 정도와 범위, 국소 심근벽 운동, 심근두께. 구혈률을 비교 분석하였다. 결과: 관동맥 중재술을 시행한 급성 심근경색 환자에서Tc-99m tetrofosmin의 역재분포 현상은67명 중 43명으로 64%였으며 391개 분절 중에서는 100개로 31%에서 관찰되었다 심근 혈류의 감소와 범위, 국소 심근벽 운동의 이상과 심근벽 두께의 감소, 구혈률은 역재분포가 있는 심근에서 더 심하였으며 통계학적 의미를 가졌다. 9개월 후 추적검사에서 관동맥 재협착의 발생은 역재분포의 유무에 따른 차이를 보이지 않았지만 Tc-99m tetrofosmin 심근관류 SPECT에서 역재분포를 보이는 심근이 혈류감소의 정도와 범위, 국소 심근벽운동의 이상, 심근 두께의 회복은 유의한 결과를 보였다. 결론: Tc-99m tetrofosmin지연기 영상에서 보이는 역재분포는 관동맥 중재술을 시행한 환자에서 관찰될 수 있으며 재혈관화 된 심근의 생존 가능성과 좌심실 기능의 회복을 예측하는데 추가적인 정보를 제공할 수 있을 것으로 사료되어 Tc-99m tetrofosmin 심근관류 영상의 임상적 유용성을 향상 시킬 수 있을 것으로 기대된다.

Encephalo-duro-arterio-synangiosis(EDAS) using Occipital Artery in Children with Moyamoya Disease

  • Choi, In-Jae;Hong, Seok-Ho;Cho, Byung-Kyu;Wang, Kyu-Chang;Kim, Seung-Ki
    • Journal of Korean Neurosurgical Society
    • /
    • 제38권6호
    • /
    • pp.413-418
    • /
    • 2005
  • Objective : Although an encephaloduroarteriosynangiosis procedure using the superficial temporal artery [STA-EDAS] is an effective indirect bypass method in children with moyamoya disease[MMD], there is still a need for an additional bypass operation that can cover the area of the posterior circulation. The goal of this study is to evaluate the efficacy of the EDAS procedure using the occipital arteries [OA-EDAS]. Methods : From August 2003 to April 2004, We performed OA-EDAS in sixteen patients with MMD who have a circulatory insufficiency in the territory of the posterior cerebral artery[PCA]. The medical records were reviewed retrospectively. The surgical outcomes, including the changes in neurological status and imaging studies, with the degree of neovascularization on the cerebral angiogram, and the hemodynamic changes on single-photon emission computed tomography[SPECT], were analyzed. Results : These 16 children consisted of 5 boys and 11 girls aged 2 to 9 years. The clinical outcome of their PCA symptoms, such as visual transient ischemic attacks[TIAs] or visual field defect, was favorable in 14 patients of 16. Nine patients of 11 who underwent follow up magnetic resonance imaging[MRI] showed favorable MRI changes. On angiogram most of the patients exhibited good or fair revascularization of the PCA territory [7 of 8]. The hemodynamic changes on SPECT in the PCA territory after surgery showed improved vascular reserve in 13 of the 16 territories. Conclusion : OA-EDAS is a safe and efficacious revascularization procedure in patients with MMD who have compromised cerebral perfusion in PCA territory, or with visual TIAs.

Recanalization Rate and Clinical Outcomes of Intravenous Tissue Plasminogen Activator Administration for Large Vessel Occlusion Stroke Patients

  • Min-Hyung Lee;Sang-Hyuk Im;Kwang Wook Jo;Do-Sung Yoo
    • Journal of Korean Neurosurgical Society
    • /
    • 제66권2호
    • /
    • pp.144-154
    • /
    • 2023
  • Objective : Stroke caused from large vessel occlusion (LVO) has emerged as the most common stroke subtype worldwide. Intravenous tissue plasminogen activator administration (IV-tPA) and additional intraarterial thrombectomy (IA-Tx) is regarded as standard treatment. In this study, the authors try to find the early recanalization rate of IV-tPA in LVO stroke patients. Methods : Total 300 patients undertook IA-Tx with confirmed anterior circulation LVO, were analyzed retrospectively. Brain computed tomography angiography (CTA) was the initial imaging study and acute stroke magnetic resonance angiography (MRA) followed after finished IV-tPA. Early recanalization rate was evaluated by acute stroke MRA within 2 hours after the IV-tPA. In 167 patients undertook IV-tPA only and 133 non-recanalized patients by IV-tPA, additional IA-Tx tried (IV-tPA + IA-Tx group). And 131 patients, non-recanalized by IV-tPA (IV-tPA group) additional IA-Tx recommend and tried according to the patient condition and compliance. Results : Early recanalization rate of LVO after IV-tPA was 12.0% (36/300). In recanalized patients, favorable outcome (modified Rankin Scale, 0-2) was 69.4% (25/36) while it was 32.1% (42/131, p<0.001) in non-recanalized patients. Among 133 patients, non-recanalized after intravenous recombinant tissue plasminogen activator and undertook additional IA-Tx, the clinical outcome was better than not undertaken additional IA-Tx (favorable outcome was 42.9% vs. 32.1%, p=0.046). Analysis according to the perfusion/diffusion (P/D)-mismatching or not, in patient with IV-tPA with IA-Tx (133 patients), favorable outcome was higher in P/D-mismatching patient (52/104; 50.0%) than P/D-matching patients (5/29; 17.2%; p=0.001). Which treatment tired, P/D-mismatching was favored in clinical outcome (iv-tPA only, p=0.008 and IV-tPA with IA-Tx, p=0.001). Conclusion : The P/D-mismatching influences on the recanalization and clinical outcomes of IV-tPA and IA-Tx. The authors would like to propose that we had better prepare IA-Tx when LVO is diagnosed on initial diagnostic imaging. Furthermore, if the patient shows P/D-mismatching on MRA after IV-tPA, additional IA-Tx improves treatment results and lessen the futile recanalization.

검사 안내문의 시각적 디자인화가 환자의 검사 이해도 및 정확성에 미치는 영향 평가 (Evaluation of the influence of a visual design of an examination guide on patient comprehension and testing accuracy)

  • 강영은;정우영;홍보름
    • 핵의학기술
    • /
    • 제23권1호
    • /
    • pp.29-34
    • /
    • 2019
  • 본 연구는 기존 안내문에서 사용하고 있는 문어체의 글자와 배열, 형태 등을 시각적으로 디자인 및 재배치 함으로써 환자의 이해도 및 검사에 미치는 영향에 대해 평가 하였다. 서울아산병원 핵의학과 영상검사에서 가장 많은 비중을 차지하는 Bone Scan과 $^{201}Thallium$ Myocardium Perfusion SPECT의 Rest Scan 안내문을 개선 대상으로 선정하고, 원내 이노베이션센터와 협의하여 새롭게 디자인 하였다. 2016년 11월부터 2017년 2월은 기존의 안내문을, 2017년 3월부터 5월은 개선된 안내문을 사용하였으며, 개선 전후의 비교를 위해 해당 시기에 Bone Scan을 시행한 환자를 대상으로 안내문에 제시된 전처치 준수 및 그에 따른 영상의 질, 검사 소요시간을 측정하였고, $^{201}Thallium$ Myocardium Perfusion SPECT를 시행한 환자를 대상으로 안내문의 내용 이해에 대한 설문조사와 안내 후 재질문 하는 환자 및 질문유형, 안내문의 내용을 이행하지 않은 환자수를 분석하였다. 개선 후에는 Bone Scan은 전 처치가 미흡한 환자와 그로 인해 추가 영상이 필요한 환자가 감소하였고 평균 검사 소요시간은 안내문 개선 후 추가 영상 획득 시간의 감소로 약 2분 감소하였다. $^{201}Thallium$ Myocardium Perfusion SPECT의 경우 안내문의 내용 이해에 대한 5가지 문항에서 모두 이해도가 증가한 결과를 얻었으며, 검사 관련 재질문 하는 환자와 안내문의 내용을 이행하지 않은 환자 모두 감소하였다. 검사 안내문은 일방적이고 단순한 정보 제공이 아니라 환자 및 보호자와의 원활한 소통으로 이어지며, 영상품질과 업무 효율성을 향상시키고 나아가 검사 소요시간의 관리로 생산성 향상에도 도움을 줄 것으로 사료된다.

THE CURRENT STATUS OF BIOMEDICAL ENGINEERING IN THE USA

  • Webster, John G.
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1992년도 춘계학술대회
    • /
    • pp.27-47
    • /
    • 1992
  • Engineers have developed new instruments that aid in diagnosis and therapy Ultrasonic imaging has provided a nondamaging method of imaging internal organs. A complex transducer emits ultrasonic waves at many angles and reconstructs a map of internal anatomy and also velocities of blood in vessels. Fast computed tomography permits reconstruction of the 3-dimensional anatomy and perfusion of the heart at 20-Hz rates. Positron emission tomography uses certain isotopes that produce positrons that react with electrons to simultaneously emit two gamma rays in opposite directions. It locates the region of origin by using a ring of discrete scintillation detectors, each in electronic coincidence with an opposing detector. In magnetic resonance imaging, the patient is placed in a very strong magnetic field. The precessing of the hydrogen atoms is perturbed by an interrogating field to yield two-dimensional images of soft tissue having exceptional clarity. As an alternative to radiology image processing, film archiving, and retrieval, picture archiving and communication systems (PACS) are being implemented. Images from computed radiography, magnetic resonance imaging (MRI), nuclear medicine, and ultrasound are digitized, transmitted, and stored in computers for retrieval at distributed work stations. In electrical impedance tomography, electrodes are placed around the thorax. 50-kHz current is injected between two electrodes and voltages are measured on all other electrodes. A computer processes the data to yield an image of the resistivity of a 2-dimensional slice of the thorax. During fetal monitoring, a corkscrew electrode is screwed into the fetal scalp to measure the fetal electrocardiogram. Correlations with uterine contractions yield information on the status of the fetus during delivery To measure cardiac output by thermodilution, cold saline is injected into the right atrium. A thermistor in the right pulmonary artery yields temperature measurements, from which we can calculate cardiac output. In impedance cardiography, we measure the changes in electrical impedance as the heart ejects blood into the arteries. Motion artifacts are large, so signal averaging is useful during monitoring. An intraarterial blood gas monitoring system permits monitoring in real time. Light is sent down optical fibers inserted into the radial artery, where it is absorbed by dyes, which reemit the light at a different wavelength. The emitted light travels up optical fibers where an external instrument determines O2, CO2, and pH. Therapeutic devices include the electrosurgical unit. A high-frequency electric arc is drawn between the knife and the tissue. The arc cuts and the heat coagulates, thus preventing blood loss. Hyperthermia has demonstrated antitumor effects in patients in whom all conventional modes of therapy have failed. Methods of raising tumor temperature include focused ultrasound, radio-frequency power through needles, or microwaves. When the heart stops pumping, we use the defibrillator to restore normal pumping. A brief, high-current pulse through the heart synchronizes all cardiac fibers to restore normal rhythm. When the cardiac rhythm is too slow, we implant the cardiac pacemaker. An electrode within the heart stimulates the cardiac muscle to contract at the normal rate. When the cardiac valves are narrowed or leak, we implant an artificial valve. Silicone rubber and Teflon are used for biocompatibility. Artificial hearts powered by pneumatic hoses have been implanted in humans. However, the quality of life gradually degrades, and death ensues. When kidney stones develop, lithotripsy is used. A spark creates a pressure wave, which is focused on the stone and fragments it. The pieces pass out normally. When kidneys fail, the blood is cleansed during hemodialysis. Urea passes through a porous membrane to a dialysate bath to lower its concentration in the blood. The blind are able to read by scanning the Optacon with their fingertips. A camera scans letters and converts them to an array of vibrating pins. The deaf are able to hear using a cochlear implant. A microphone detects sound and divides it into frequency bands. 22 electrodes within the cochlea stimulate the acoustic the acoustic nerve to provide sound patterns. For those who have lost muscle function in the limbs, researchers are implanting electrodes to stimulate the muscle. Sensors in the legs and arms feed back signals to a computer that coordinates the stimulators to provide limb motion. For those with high spinal cord injury, a puff and sip switch can control a computer and permit the disabled person operate the computer and communicate with the outside world.

  • PDF