Magnetic resonance image-based tomotherapy planning for prostate cancer

  • Jung, Sang Hoon;Kim, Jinsung;Chung, Yoonsun;Keserci, Bilgin;Pyo, Hongryull;Park, Hee Chul;Park, Won
    • Radiation Oncology Journal
    • /
    • v.38 no.1
    • /
    • pp.52-59
    • /
    • 2020
  • Purpose: To evaluate and compare the feasibilities of magnetic resonance (MR) image-based planning using synthetic computed tomography (sCT) versus CT (pCT)-based planning in helical tomotherapy for prostate cancer. Materials and Methods: A retrospective evaluation was performed in 16 patients with prostate cancer who had been treated with helical tomotherapy. MR images were acquired using a dedicated therapy sequence; sCT images were generated using magnetic resonance for calculating attenuation (MRCAT). The three-dimensional dose distribution according to sCT was recalculated using a previously optimized plan and was compared with the doses calculated using pCT. Results: The mean planning target volume doses calculated by sCT and pCT differed by 0.65% ± 1.11% (p = 0.03). Three-dimensional gamma analysis at a 2%/2 mm dose difference/distance to agreement yielded a pass rate of 0.976 (range, 0.658 to 0.986). Conclusion: The dose distribution results obtained using tomotherapy from MR-only simulations were in good agreement with the dose distribution results from simulation CT, with mean dose differences of less than 1% for target volume and normal organs in patients with prostate cancer.

Evaluation of the correlation between the muscle fat ratio of pork belly and pork shoulder butt using computed tomography scan

  • Sheena Kim;Jeongin Choi;Eun Sol Kim;Gi Beom Keum;Hyunok Doo;Jinok Kwak;Sumin Ryu;Yejin Choi;Sriniwas Pandey;Na Rae Lee;Juyoun Kang;Yujung Lee;Dongjun Kim;Kuk-Hwan Seol;Sun Moon Kang;In-Seon Bae;Soo-Hyun Cho;Hyo Jung Kwon;Samooel Jung;Youngwon Lee;Hyeun Bum Kim
    • Korean Journal of Agricultural Science
    • /
    • v.50 no.4
    • /
    • pp.809-815
    • /
    • 2023
  • This study was conducted to find out the correlation between meat quality and muscle fat ratio in pork part meat (pork belly and shoulder butt) using CT (computed tomography) imaging technique. After 24 hours from slaughter, pork loin and belly were individually prepared from the left semiconductors of 26 pigs for CT measurement. The image obtained from CT scans was checked through the picture archiving and communications system (PACS). The volume of muscle and fat in the pork belly and shoulder butt of cross-sectional images taken by CT was estimated using Vitrea workstation version 7. This assemblage was further processed through Vitrea post-processing software to automatically calculate the volumes (Fig. 1). The volumes were measured in milliliters (mL). In addition to volume calculation, a three-dimensional reconstruction of the organ under consideration was generated. Pearson's correlation coefficient was analyzed to evaluate the relationship by region (pork belly, pork shoulder butt), and statistical processing was performed using GraphPad Prism 8. The muscle-fat ratios of pork belly taken by CT was 1 : 0.86, while that of pork shoulder butt was 1 : 0.37. As a result of CT analysis of the correlation coefficient between pork belly and shoulder butt compared to the muscle-fat ratio, the correlation coefficient was 0.5679 (R2 = 0.3295, p < 0.01). CT imaging provided very good estimates of muscle contents in cuts and in the whole carcass.

Safe Margin beyond Dens Tips to Ventral Dura in Anterior Odontoid Screw Fixation : Analysis of Three-Dimensional Computed Tomography Scan of Odontoid Process

  • Sung, Min-Jae;Kim, Kyoung-Tae;Hwang, Jeong-Hyun;Sung, Joo-Kyung;Cho, Dae-Chul
    • Journal of Korean Neurosurgical Society
    • /
    • v.61 no.4
    • /
    • pp.503-508
    • /
    • 2018
  • Objective : Anterior odontoid screw fixation is a safe and effective method for the treatment of odontoid fractures. The surgical technique is recommended for perforation of the apical cortex of the dens by the lag screw. However, overpenetration of the apical cortex may lead to potentially serious complications such as damages of adjacent vascular and neural structures. The purpose of this study was to assess the role of three-dimensional computed tomography (CT) scan to evaluate the safe margin beyond dens tip to ventral dura for anterior odontoid screw fixation. Methods : We retrospectively analyzed the three-dimensional CT scans of the cervical spines in 55 consecutive patients at our trauma center. The patients included 38 males and 17 females aged between 22 and 73 years (mean age${\pm}$standard deviation, $45.8{\pm}14.2years$). Using sagittal images of 3-dimensional CT scan, the safe margins beyond dens tip to ventral dura as well as the appropriate screw length were measured. Results : The mean width of the apical dens tip was $9.6{\pm}1.1mm$. The mean lengths from the screw entry point to the apical dens tip and posterior end of dens tip were $39.2{\pm}2.6mm$ and $36.6{\pm}2.4mm$. The safe margin beyond apical dens tip to ventral dura was $7.7{\pm}1.7mm$. However, the safe margin beyond the posterior end of dens tip to ventral dura was decreased to $2.1{\pm}3.2mm$, which was statistically significant (p<0.01). There were no significant differences of safe margins beyond dens tip to ventral dura with patient gender and age. Conclusion : Extension by several millimeters beyond the dens tip is safe, if the trajectory of anterior odontoid screw is targeted at the apical dens tip. However, if the trajectory of the screw is targeted to the posterior end of dens tip, extension beyond dens tip may lead to damage immediately adjacent to the vental dura mater.

Three-Dimensional Volume Assessment Accuracy in Computed Tomography Using a Phantom (모형물을 이용한 전산화 단층 촬영에서 3차원적 부피측정의 정확성 평가)

  • Kim, Hyun-Su;Wang, Ji-Hwan;Lim, Il-Hyuk;Park, Ki-Tae;Yeon, Seong-Chan;Lee, Hee-Chun
    • Journal of Veterinary Clinics
    • /
    • v.30 no.4
    • /
    • pp.268-272
    • /
    • 2013
  • The purpose of this study was to assess the effects of reconstruction kernel, and slice thickness on the accuracy of spiral CT-based volume assessment over a range of object sizes typical of synthetic simulated tumor. Spiral CT scanning was performed at various reconstruction kernels (soft tissue, standard, bone), and slice thickness (1, 2, 3 mm) using a phantom made of gelatin and 10 synthetic simulated tumors of different sizes (diameter 3.0-12.0 mm). Three-dimensional volume assessments were obtained using an automated software tool. Results were compared with the reference volume by calculating the percentage error. Statistical analysis was performed using ANOVA and setting statistical significance at P < 0.05. In general, smaller slice thickness and larger sphere diameters produced more accurate volume assessment than larger slice thickness and smaller sphere diameter. The measured volumes were larger than the actual volumes by a common factor depending on slice thickness; in 100HU simulated tumors that had statistically significant, 1 mm slice thickness produced on average 27.41%, 2 mm slice thickness produced 45.61%, 3 mm slice thickness produced 93.36% overestimates of volume. However, there was no statistically significant difference in volume error for spiral CT scans taken with techniques where only reconstruction kernel was changed. These results supported that synthetic simulated tumor size, slice thickness were significant parameters in determining volume measurement errors. For an accurate volumetric measurement of an object, it is critical to select an appropriate slice thickness and to consider the size of an object.

Spiral scanning imaging and quantitative calculation of the 3-dimensional screw-shaped bone-implant interface on micro-computed tomography

  • Choi, Jung-Yoo Chesaria;Choi, Cham Albert;Yeo, In-Sung Luke
    • Journal of Periodontal and Implant Science
    • /
    • v.48 no.4
    • /
    • pp.202-212
    • /
    • 2018
  • Purpose: Bone-to-implant contact (BIC) is difficult to measure on micro-computed tomography (CT) because of artifacts that hinder accurate differentiation of the bone and implant. This study presents an advanced algorithm for measuring BIC in micro-CT acquisitions using a spiral scanning technique, with improved differentiation of bone and implant materials. Methods: Five sandblasted, large-grit, acid-etched implants were used. Three implants were subjected to surface analysis, and 2 were inserted into a New Zealand white rabbit, with each tibia receiving 1 implant. The rabbit was sacrificed after 28 days. The en bloc specimens were subjected to spiral (SkyScan 1275, Bruker) and round (SkyScan 1172, SkyScan 1275) micro-CT scanning to evaluate differences in the images resulting from the different scanning techniques. The partial volume effect (PVE) was optimized as much as possible. BIC was measured with both round and spiral scanning on the SkyScan 1275, and the results were compared. Results: Compared with the round micro-CT scanning, the spiral scanning showed much clearer images. In addition, the PVE was optimized, which allowed accurate BIC measurements to be made. Round scanning on the SkyScan 1275 resulted in higher BIC measurements than spiral scanning on the same machine; however, the higher measurements on round scanning were confirmed to be false, and were found to be the result of artifacts in the void, rather than bone. Conclusions: The results of this study indicate that spiral scanning can reduce metal artifacts, thereby allowing clear differentiation of bone and implant. Moreover, the PVE, which is a factor that inevitably hinders accurate BIC measurements, was optimized through an advanced algorithm.

Measurement of S1 foramen depth for ultrasound-guided S1 transforaminal epidural injection

  • Ye Sull Kim;SeongOk Park;Chanhong Lee;Sang-Kyi Lee;A Ram Doo;Ji-Seon Son
    • The Korean Journal of Pain
    • /
    • v.36 no.1
    • /
    • pp.98-105
    • /
    • 2023
  • Background: Ultrasound-guided first sacral transforaminal epidural steroid injection (S1 TFESI) is a useful and easily applicable alternative to fluoroscopy or computed tomography (CT) in lumbosacral radiculopathy. When a needle approach is used, poor visualization of the needle tip reduces the accuracy of the procedure, increasing its difficulty. This study aimed to improve ultrasound-guided S1 TFESI by evaluating radiological S1 posterior foramen data obtained using three-dimensional CT (3D-CT). Methods: Axial 3D-CT images of the pelvis were retrospectively analyzed. The radiological measurements obtained from the images included 1st posterior sacral foramen depth (S1D, mm), 1st posterior sacral foramen width (S1W, mm), the angle of the 1st posterior sacral foramen (S1A, °), and 1st posterior sacral foramen distance (S1ds, mm). The relationship between the demographic factors and measured values were then analyzed. Results: A total of 632 patients (287 male and 345 female) were examined. The mean S1D values for males and females were 11.9 ± 1.9 mm and 10.6 ± 1.8 mm, respectively (P < 0.001); the mean S1A 28.2 ± 4.8° and 30.1 ± 4.9°, respectively (P < 0.001); and the mean S1ds, 24.1 ± 2.9 mm and 22.9 ± 2.6 mm, respectively (P < 0.001); however, the mean S1W values were not significantly different. Height was the only significant predictor of S1D (β = 0.318, P = 0.004). Conclusions: Ultrasound-guided S1 TFESI performance and safety may be improved with adjustment of needle insertion depth congruent with the patient's height.

Assessment of the proximity between the mandibular third molar and inferior alveolar canal using preoperative 3D-CT to prevent inferior alveolar nerve damage

  • Lee, Byeongmin;Park, Youngju;Ahn, Janghoon;Chun, Jihyun;Park, Suhyun;Kim, Minjin;Jo, Youngserk;Ahn, Somi;Kim, Beulha;Choi, Sungbae
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.37
    • /
    • pp.30.1-30.7
    • /
    • 2015
  • Background: The inferior alveolar nerve (IAN) may be injured during extraction of the mandibular third molar, causing severe postoperative complications. Many methods have been described for evaluating the relative position between the mandibular third molar and the inferior alveolar canal (IAC) on panoramic radiography and computed tomography, but conventional radiography provides limited information on the proximity of these two structures. The present study assessed the benefits of three-dimensional computed tomography (3D-CT) prior to surgical extraction of the mandibular third molar, to prevent IAN damage. Methods: This retrospective study included 4917 extractions in 3555 patients who presented for extraction of the mandibular third molars. The cases were classified into three groups, according to anatomical relationship between the mandibular third molars and the IAC on panoramic radiography and whether 3D-CT was performed. Symptoms of IAN damage were assessed using the touch-recognition test. Data were compared using the chi-square test and Fisher's exact test. Results: Among the 32 cases of IAN damage, 6 cases were included in group I (0.35 %, n = 1735 cases), 23 cases in group II (1.1 %, n = 2063 cases), and 3 cases in group III (0.27 %, n = 1119 cases). The chi-square test showed a significant difference in the incidence of IAN damage between groups I and II. No significant difference was observed between groups I and III using Fisher's exact test. In the 6 cases of IAN damage in group I, the mandibular third molar roots were located lingual relative to the IAC in 3 cases and middle relative to the IAC in 3 cases. The overlap was ${\geq}2mm$ in 3 of 6 cases and 0-2 mm in the remaining 3 cases. The mean distance between the mandibular third molar and IAC was 2.2 mm, the maximum distance 12 mm, and the minimum distance 0.5 mm. Greater than 80 % recovery was observed in 15 of 32 (46.8 %) cases of IAN damage. Conclusions: 3D-CT may be a useful tool for assessing the three-dimensional anatomical relationship and proximity between the mandibular third molar and IAC in order to prevent IAN damage during extraction of mandibular third molars.

Evaluation of Focal Bone Mineral Density Using Three-dimensional Measurement of Hounsfield Units in the Proximal Humerus

  • Moon, Young Lae;Jung, Sung;Park, Sang Ha;Choi, Gwi Youn
    • Clinics in Shoulder and Elbow
    • /
    • v.18 no.2
    • /
    • pp.86-90
    • /
    • 2015
  • Background: Although there are several methods for evaluating bone quality, Hounsfield units (HU), a standardized computed tomography (CT) attenuation coefficient, provide a useful tool for estimating focal bone mineral density (BMD). The aim of this study is to investigate the HU for evaluating the degree of osteoporosis in greater tuberosity with regard to anchor positioning. Methods: Forty patients diagnosed as normal on shoulder CT were included and categorized according to age and gender. Axially sectioned CT images were processed to 3-dimensional models containing information about bone quality using Mimics (14.11 platform v14.1.1.1 Materialise). Three-dimensional anchors were simulated and positioned according to 6 regions of interest (ROI) in the greater tuberosity classified using Tingart's system. Mean HU of intra-anchor volumes in the 6 regions was measured. Results: A significant decrease in HU was observed with increasing age (p=0.0001) and menopause (p<0.001). A significant difference in HU was found between male and female groups with males showing the higher values (p=0.0001). HU of proximal areas of ROI was higher than those of distal areas (p<0.005). However, although mean HU of distal posterior ROI showed the lowest values, no statistically significant difference was found between anterior, middle, and posterior regions (p=0.087). Conclusions: Mean HU of ROIs provides a tool for preoperative assessment of focal BMD, which is a factor of suture anchor stability and can be used to aid decision-making regarding secure anchor positioning for rotator cuff repair. Our data support that the most secure point is the proximal regions of ROI.

Relationship between trabecular strength and three-dimensional architecture in the pig mandible using microcomputed tomography (돼지 하악골의 micro-CT영상에서 추출한 3차원 골미세구조와 골강도 사이의 상관관계)

  • Huh Kyung-Hoe;Park Moo-Soon;Yi Won-Jin;Heo Min-Suk;Lee Sam-Sun;Choi Soon-Chul
    • Imaging Science in Dentistry
    • /
    • v.35 no.3
    • /
    • pp.167-173
    • /
    • 2005
  • Purpose : To investigate the relationship between three-dimensional (3D) bone imaging parameters and trabecular strength in the mandible. Materials and Methods : Bone specimens were obtained from the mandibles of five male pigs weighing around 110 kg each. Of those, 43 samples were selected for 3D analysis and measured by micro-computed tomography. The five morphometric parameters were trabecular thickness (Tb.Th), bone specific surface (BS/BV), percent bone volume (BV/TV), structure model index (SMI) and degree of anisotropy (DA). Through destructive mechanical testing, strength parameters were obtained. Results : BV/TV, SMI, BS/BV, and Tb.Th showed significant correlations with strength parameters. DA did not show any correlation with the other parameters. In multiple linear regression analysis, BV/TV alone explained $43\%$ of the variance in Young's modulus. By stepwise inclusion of SMI, the variance in the Young's modulus was better explained up to $52\%$. Conclusions : Predicting trabecular strength in the mandible through architectural analysis would be possible. Further study is needed to establish the tendency and variety of trabecular architecture and strength according to the locations within the mandible.