• 제목/요약/키워드: Computed tomography (CT), maximum intensity projection

검색결과 14건 처리시간 0.025초

호흡동조전산화단층촬영과 콘빔전산화단층촬영의 팬텀 영상 체적비교 (Comparison of Volumes between Four-Dimensional Computed Tomography and Cone-Beam Computed Tomography Images using Dynamic Phantom)

  • 김성은;원희수;홍주완;장남준;정우현;최병돈
    • 대한방사선치료학회지
    • /
    • 제28권2호
    • /
    • pp.123-130
    • /
    • 2016
  • 목 적 : Computerized imaging reference systems 동적팬텀을이용한 cone-beamcomputed tomography(CBCT) 영상과 four-dimensionalcomputed tomography(4DCT) 영상의 체적을 비교분석 하고자 한다. 대상 및 방법 : 동적팬텀 내에 직경 1, 2, 3 cm 노드를 각각 삽입하고, CT simulator와 TruebeamSTx X-ray Imaging system을 이용하여 4DCT 영상과 CBCT 영상을 얻었다. 4DCT 영상은 maximum intensity projection(MIP), minimum intensity projection(MinIP), 그리고 average intensity projection(AVG)영상으로 재구성 하고 노드의 체적은 Eclipse system의 CT ranger tool로 CT number를 설정하여 측정하였다. 결 과 : CBCT를 기준으로 노드1, 2, 3 cm의 체적을 비교하였을 때 4DCT의 MIP는 0.54~2.33, 5.16~8.06, 9.03~20.11 ml, MinIP는 0.00~1.48, 0.00~8.47, 1.42~24.85 ml, AVG는 0.00~1.17, 0.00~2.19, 0.04~3.35 ml의 차이를 보였다. 결 론 : 노드의 체적을 비교한 결과 CBCT 영상은 4DCT의 AVG 영상과 유사한 것으로 확인되었다.

  • PDF

Accuracy Analysis of Magnetic Resonance Angiography and Computed Tomography Angiography Using a Flow Experimental Model

  • Heo, Yeong-Cheol;Lee, Hae-Kag;Park, Cheol-Soo;Cho, Jae-Hwan
    • Journal of Magnetics
    • /
    • 제20권1호
    • /
    • pp.40-46
    • /
    • 2015
  • This study investigated the accuracy of magnetic resonance angiography (MRA) and computed tomography angiography (CTA) in terms of reflecting the actual vascular length. Three-dimensional time of flight (3D TOF) MRA, 3D contrast-enhanced (CE) MRA, volume-rendering after CTA and maximum intensity projection were investigated using a flow model phantom with a diameter of 2.11 mm and area of $0.26cm^2$. 1.5 and 3.0 Tesla devices were used for 3D TOF MRA and 3D CE MRA. CTA was investigated using 16 and 64 channel CT scanners, and the images were transmitted and reconstructed by volume-rendering and maximum intensity projection, followed by conduit length measurement as described above. The smallest 3D TOF MRA measure was $2.51{\pm}0.12mm$ with a flow velocity of 40 cm/s using the 3.0 Tesla apparatus, and $2.57{\pm}0.07mm$ with a velocity of 71.5 cm/s using the 1.5 Tesla apparatus; both images were magnified from the actual measurement of 2.11 mm. The measurement with the 16 channel CT scanner was smaller ($3.83{\pm}0.37mm$) than the reconstructed image on maximum intensity projection. The images from CTA from examination apparatus and reconstruction technique were all larger than the actual measurement.

Gross tumor volume dependency on phase sorting methods of four-dimensional computed tomography images for lung cancer

  • Lee, Soo Yong;Lim, Sangwook;Ma, Sun Young;Yu, Jesang
    • Radiation Oncology Journal
    • /
    • 제35권3호
    • /
    • pp.274-280
    • /
    • 2017
  • Purpose: To see the gross tumor volume (GTV) dependency according to the phase selection and reconstruction methods, we measured and analyzed the changes of tumor volume and motion at each phase in 20 cases with lung cancer patients who underwent image-guided radiotherapy. Materials and Methods: We retrospectively analyzed four-dimensional computed tomography (4D-CT) images in 20 cases of 19 patients who underwent image-guided radiotherapy. The 4D-CT images were reconstructed by the maximum intensity projection (MIP) and the minimum intensity projection (Min-IP) method after sorting phase as 40%-60%, 30%-70%, and 0%-90%. We analyzed the relationship between the range of motion and the change of GTV according to the reconstruction method. Results: The motion ranges of GTVs are statistically significant only for the tumor motion in craniocaudal direction. The discrepancies of GTV volume and motion between MIP and Min-IP increased rapidly as the wider ranges of duty cycles are selected. Conclusion: As narrow as possible duty cycle such as 40%-60% and MIP reconstruction was suitable for lung cancer if the respiration was stable. Selecting the reconstruction methods and duty cycle is important for small size and for large motion range tumors.

연속 CT 영상에서 템플릿 매칭을 이용한 폐결절 정합 (Pulmonary Nodule Registration using Template Matching in Serial CT Scans)

  • 조현희;홍헬렌
    • 한국정보과학회논문지:소프트웨어및응용
    • /
    • 제36권8호
    • /
    • pp.623-632
    • /
    • 2009
  • 본 논문에서는 연속시점에서 촬영한 CT 영상에서 대응되는 폐결절을 추적 관찰하기 위한 폐결절 정합 방법을 제안한다. 제안 방법은 다음과 같은 다섯 단계로 구생된다. 첫째, 분할된 폐를 포함하는 최적경계볼륨의 중심으로 위치 차이를 보정한다. 둘째, 초기 CT 영상과 추적 CT 영상에서 가장 높은 밝기값을 가지고 있는 갈비뼈 구조를 포함하는 관상최대강도투사 영상을 생성한다. 셋째, 두 관상최대강도투사 영상 간의 정규화된 평균 밝기값 차이를 통해 강체 변환을 최적화한다. 넷째, 강체 정합 후에 폐결절 중심 간의 유클라디안 거리 측정을 통해 대응되는 폐결절 대응 후보를 정의한다. 마지막으로, 폐결절을 매칭하기 위하여 초기 CT 영상 내에 폐결절 템플릿과 추적 CT 영상 내에 탐색 볼륨 간의 템플릿 매칭을 수행 한다. 본 제안 방법의 결과를 평가하기 위하여 육안 평가, 정확성 및 수행시간 측정을 수행하였다. 실험결과 관상최대강도투사를 기반으로 하는 강체정합과 지역적 템플릿 매칭을 이용하여 폐결절이 정확하고 빠르게 정합됨을 알 수 있었다.

Single Centre Experience on Decision Making for Mechanical Thrombectomy Based on Single-Phase CT Angiography by Including NCCT and Maximum Intensity Projection Images - A Comparison with Magnetic Resonance Imaging after Non-Contrast CT

  • Kim, Myeong Soo;Kim, Gi Sung
    • Journal of Korean Neurosurgical Society
    • /
    • 제63권2호
    • /
    • pp.188-201
    • /
    • 2020
  • Objective : The purpose of this study was to suggest that computed tomography angiography (CTA) is valuable as the only preliminary examination for mechanical thrombectomy (MT). MT after single examination of CTA including noncontrast computed tomography (NCCT) and maximum intensity projection (MIP) improves door-to-puncture time as well as results in favorable outcomes. Methods : A total of 157 patients who underwent MT at Dong Kang Medical Center from April 2015 to March 2019 were divided into two groups based on the examination performed prior to MT : CTA group who underwent CTA with NCCT and MIP, and NCCT+magnetic resonance image (MRi) group who underwent MRI including perfusion images after NCCT. In the two groups, time to CTA imaging or NCCT+MRi imaging after symptom onset, and time to arterial puncture and reperfusion were characterized as time-related outcomes. The evaluation of vascular recanalization after MT was defined as a modified thrombolysis in cerebral infarction (mTICI) scale. National Institutes of Health Stroke Scale (NIHSS) was assessed at the time of the visit to the emergency room and modified Rankin Scale (mRS) was assessed after 90 days. Results : Typically, there were 34 patients in the CTA group and 33 patients in the NCCT+MRi group. A significantly shorter delay for door-to-puncture time was observed (mean, 86±22.1 vs. 176±47.5 minutes; <0.01). Also, a significantly shorter door-to-imege time in the CTA group was observed (mean, 13±6.8 vs. 93±30.8 minutes; p<0.01). Moreover, a significantly shorter onset-to-puncture time was observed (mean, 195±128.0 vs. 314±157.6 minutes; p<0.01). Reperfusion result of mTICI ≥2b was 100% (34/34) in the CTA group and 94% (31/33) in the NCCT+MRi group, and mTICI 3 in 74% (25/34) in the CTA group and 73% (24/33) in the NCCT+MRi group. Favorable functional outcomes (mRS score ≤2 at 90 days) were 68% (23/34) in the CTA group and 60% (20/33) in the NCCT+MRi group. Conclusion : A single-phase CTA including NCCT and MIP images was performed as a single preliminary examination, which led to a reduction in the time of the procedure and resulted in good results of prognosis. Consequently, it is concluded that this method is of sufficient value as the only preliminary examination for decision making.

전산화단층검사에서 조영제의 피하 정맥 혈관외유출 환자의 3D영상 (Subcutaneous Injection Contrast Media Extravasation: 3D CT Appearance)

  • 권대철;김태형;양성환;유병규;김명구;박범
    • 한국의학물리학회지:의학물리
    • /
    • 제16권1호
    • /
    • pp.47-51
    • /
    • 2005
  • 전산화단층검사에서 조영제를 자동주입기를 이용해 주입하여 검사하는 경우에 혈관 외 유출된 성인환자를 대상으로 하였다. 환자의 혈관외유출 사고의 조영제 양은 47 ml로 오른쪽 손목 부위가 부종을 동반하였다. 혈관외유출된 손상부위를 axial 스캔하여 MPR (multi-planar reformation), MIP (maximum intensity protection), volume rendering, SSD (shaded-surface display) 기법으로 구성하였다. 이러한 3D 영상은 조영제의 혈관외유출 환자의 예방 및 사후 조치에 적절한 치료계획의 방법으로 기대된다.

  • PDF

척추경 나사못 고정술 시행 후 3차원 재구성CT영상의 유용성 평가 (Evaluation on usefulness of three dimensional reconstructive computed tomography images after pedicle screws fixation)

  • 김현주;장현철;조재환
    • 디지털콘텐츠학회 논문지
    • /
    • 제11권4호
    • /
    • pp.553-559
    • /
    • 2010
  • 본 연구는 척추경 나사못 고정술을 시행한 환자를 대상으로 고정술 전, 후 전산화 단층촬영 영상의 원 자료(raw data)를 이용하여 다양한 재구성 기법을 적용하여 나사못의 정확한 위치파악과 수술의 정확도 등 다양한 정보를 알아보고자 하였다. 임상에서 주로 이용 하는 재구성기법인 다평면재구성(MPR), 최대강도투영(MIP), 체적묘사기법(VRT)과 변형 제적묘사기법(modifying VRT)을 적용하여 영상데이터를 각 각 정량적 방법과 정성적 방법으로 비교 분석하였다. 재구성 영상의 분석 및 평가결과 전산화 단층촬영 영상재구성 기법 중 척추경 나사못 고정술 후 나사의 정확한 위치파악과 금속에 의한 인공음영을 최소화 시키는데 가장 유용한 재구성 기법으로는 변형 체적묘사기법으로 사료된다.

흰쥐 미세구조 관찰을 위한 Micro-CT 3D 영상의 유용성에 관한 연구 (A Study on the Usefulness of 3D Imaging in Micro-CT for Observing the Microstructure of Mice)

  • 이상호;이종석;임청환;정홍량;채규윤;한범휘;한상현;홍동희;한태종;박성훈;모은희;전홍영
    • 디지털융복합연구
    • /
    • 제12권3호
    • /
    • pp.367-375
    • /
    • 2014
  • 본 연구는 실시간 동적영상(Real-time dynamic image)을 획득할 수 있는 고해상도 엑스선 영상장치인 마이크로 CT 을 이용하여 흰쥐의 미세 혈관구조를 관찰함은 물론 국내 원광 방사선영상 과학연구 센터에서 개발한 마이크로 CT 에 대한 유용성을 알아보고자 한다. 흰쥐 몸 전체의 2D 영상을 얻은 후 MIP(maximum intensity projection), VRT(volume rendering technique)기법을 이용하여 혈관구조의 조영된 3D 영상을 얻을 수 있었고 이 3D 혈관 영상을 머리, 복부, 심장과 몸 전체의 혈관시스템으로 각각 분류하였다.

CT검사에서 조영제의 혈관외유출에 의한 목 및 흉부 손상의 3차원 재구성 영상 (Extravasation Injury of Contrast Media in the Neck and Thorax During MDCT Scanning with 3D Image Reformation Findings)

  • 권대철;장근조;유병규;이종석
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제30권3호
    • /
    • pp.281-287
    • /
    • 2007
  • 전산화단층촬영에서 조영제를 자동주입기로 주입하는 과정에서 발생하는 혈관외유출은 조직의 괴사 및 손상의 원인이 되고 있다. 대량의 혈관외유출은 구획증후군으로 발전하여 근막절개술을 시행하는 경우가 발생한다. 혈관외유출이 발생한 환자를 대상으로 혈관외유출 범위 및 부위 정도를 평가하기 위해 CT 검사에서 경정맥에 조영제을 주입하는 과정에서 혈관외유출이 발생한 환자를 대상으로 하였다. 조영제에 의한 혈관외유출 범위 및 손상을 확인하기 조영제 주입부위의 목 및 가슴의 부위를 MDCT를 이용하여 스캔하였다. 경정맥 주사부위의 혈관외유출부위를 MPR, MIP와 볼륨 렌더링의 3차원영상을 3D 프로그램을 이용하여 묘출하였다. 3차원 재구성 영상은 높은 해상력과 정확도를 제공하여 혈관외유출 범위 및 부위를 확인 하여, 환자의 예방의 필요성 및 사후 조치 및 적절한 치료와 수술 계획에 유용하게 이용될 것으로 기대된다.

  • PDF

MDCT에서 Curved MPR을 이용한 효과적인 영상진단 (The Effective Image Diagnosis Using Curved MPR from MDCT)

  • 송종남;장영일
    • 대한디지털의료영상학회논문지
    • /
    • 제12권2호
    • /
    • pp.139-143
    • /
    • 2010
  • Two-dimensional(2D) images like Multi Planar Reconstruction(MPR) Image or Maximum Intensity Projection(MIP) were used for the purpose of diagnosis, but MPR image's quality were limited due to its superior limit of Z-axis ability to produce permitted radiation exposure virtuous in the permitted time limit from the existing Spiral CT. However, in company with the development of the Multi Detector Computed Tomography(MDCT), we were able to get the Data with the equal amount of Voxel, also get varied reconstructions as in the aspect of our needs. This present study propose a reconstruction technique which is to extract a field using Region of interest(ROI) segmentation method for improvement of the quality of the medical image and after that reconstruct the concerned part using the four-directed symmetry method of the oval, than using the reconstructed data, reorganize the image by using the Curved MPR method. If current proposed method is used, it is highly effective because of its ability to accurately display the disease concerned part, which will reduce the decoding time and also effectively provide information based on the accuracy of the decode.

  • PDF