• Title/Summary/Keyword: Computed Tomography (CT) image

Search Result 661, Processing Time 0.036 seconds

Invisible Parotid Gland Pleomorphic Adenoma on Contrast Enhanced-Computed Tomography (조영증강 전산화단층촬영검사에서 보이지 않는 이하선의 다형선종)

  • Heo, Jae Hyung;Kim, Da Mi;Koo, Bon Seok;Chang, Jae Won
    • Korean Journal of Head & Neck Oncology
    • /
    • v.32 no.2
    • /
    • pp.85-89
    • /
    • 2016
  • Pleomorphic adenomas is the most common tumor of parotid gland and usually located and confined in superficial lobe of parotid gland. Computed tomography (CT) is commonly used to initially evaluate salivary gland lesion, but contrast-enhanced CT may sometimes fail to reveal lesions in spite of a high clinical suspicion. For this reason, ultrasonography (US) can be used as the first-line image work-up in some cases of parotid gland benign tumors. We experienced a case of a 60-year-old woman without underlying disease presenting a palpable parotid mass in which the initial CT examination was reported as 'no obvious mass detected'. However, the lesion was revealed in US and histologically confirmed as pleomorphic adenoma. The patient underwent superficial parotidectomy through modified facelift incision. To the best of our knowledge, this is the first report of invisible major salivary gland tumor on CT in the Korean literature.

The Role of CT as a Preoperative Evaluation of Lateral Cervical Lymph Node Metastasis in Papillary Thyroid Carcinoma (갑상선 유두암의 외측 경부림프절 전이에 대한 수술 전 평가로서 CT의 역할)

  • Seok, Jungirl;Kim, Hyung Gu;Kim, Yoonjoong;Han, Kyu-Hee;Ahn, Soon-Hyun
    • Korean Journal of Head & Neck Oncology
    • /
    • v.29 no.2
    • /
    • pp.37-40
    • /
    • 2013
  • Background and Objectives : To assess the usefulness of computed tomography image before papillary thyroid cancer surgery, focus on confirmation of lateral cervical lymph node metastasis not detected by ultrasonography. Material and Methods : From January 2008 to May 2009, total 150 patients who had undergone thyroid surgery and been confirmed papillary thyroid cancer pathologically were enrolled. They had taken neck computed tomography following the ultrasonography. Results : Computed tomography had found suspicious metastatic lateral neck lesion in 13 patients. After the image study, lateral neck lymph node dissection had been included in their surgical plan. Of these, only 7 cases were confirmed pathologically lateral neck lymph node metastasis(positive predictive value=0.54). Taken as whole 150 patients, additionally 4.7% of patients confirmed lateral neck lymph node metastasis by preoperative computed tomography. Conclusion : If preoperative ultrasonography was performed precisely, additional benefits that could be achieved by computed tomography were not much.

Moderate hypofractionated image-guided thoracic radiotherapy for locally advanced node-positive non-small cell lung cancer patients with very limited lung function: a case report

  • Manapov, Farkhad;Roengvoraphoj, Olarn;Li, Minglun;Eze, Chukwuka
    • Radiation Oncology Journal
    • /
    • v.35 no.2
    • /
    • pp.180-184
    • /
    • 2017
  • Patients with locally advanced lung cancer and very limited pulmonary function (forced expiratory volume in 1 second $[FEV1]{\leq}1L$) have dismal prognosis and undergo palliative treatment or best supportive care. We describe two cases of locally advanced node-positive non-small cell lung cancer (NSCLC) patients with very limited lung function treated with induction chemotherapy and moderate hypofractionated image-guided radiotherapy (Hypo-IGRT). Hypo-IGRT was delivered to a total dose of 45 Gy to the primary tumor and involved lymph nodes. Planning was based on positron emission tomography-computed tomography (PET/CT) and four-dimensional computed tomography (4D-CT). Internal target volume (ITV) was defined as the overlap of gross tumor volume delineated on 10 phases of 4D-CT. ITV to planning target volume margin was 5 mm in all directions. Both patients showed good clinical and radiological response. No relevant toxicity was documented. Hypo-IGRT is feasible treatment option in locally advanced node-positive NSCLC patients with very limited lung function ($FEV1{\leq}1L$).

Image Quality Evaluation according to the Application of Air Mattress on Computed Tomography Equipment Table (전산화단층촬영장비 테이블의 에어 매트리스 적용에 따른 화질평가)

  • Jeon, Sang-Won;Pak, Jae-Yun;Suh, Tae-Suk
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.6
    • /
    • pp.819-825
    • /
    • 2020
  • The purpose of this study was to evaluate the usefulness of the developed air mattress for reducing the deterioration of image quality due to the scattered radiation generated on the computed tomography equipment table. 5 cm and 10 cm thick air mattresses were developed and the image quality was measured by scanning the AAPM phantom according to thickness and thickness. Statistical significance was confirmed by One Way Analysis of Variance(ANOVA) Compared with the AAPM phantom scanned in the standard method, the image with the air mattress did not show any difference, but when the air mattress was not applied, the CT number and uniformity were low and the noise was high, and the spatial resolution Respectively. The developed air mattress has no harmful effect on the diagnostic image, it is very effective in improving the image quality and can increase the CT image quality by simply applying Air Mattress to existing equipment without using the technology applied to the latest and high-cost equipment.

CT and MRI Image Fusion Reproducibility and Dose Assessment on Treatment Planning System (치료계획시스템에서 전산화단층촬영과 자기공명영상의 영상융합 재현성 및 선량평가)

  • Choi, Jae-Hyock;Park, Cheol-Soo;Seo, Jeong-Min;Cho, Jae-Hwan;Choi, Cheon-Woong
    • Journal of the Korean Magnetics Society
    • /
    • v.24 no.6
    • /
    • pp.191-196
    • /
    • 2014
  • The purpose of this study is to evaluate the reproducibility and usefulness of an image through the fusion of the computed tomography image and the magnetic resonance image by using a self-produced phantom when planning the treatment, and also to compare and analyze the target dose on the acquired image. The size of small hole and the reproducibility of capacity existed in the phantom on the image of the phantom obtained by the computed tomography and the magnetic resonance image of the phantom scanning with different intensity of magnetic field are compared, and the change of dose in the random target is compared and analyzed.

A Study on Establishment of Essential Performance Evaluation Criteria for C-arm Computed Tomography (C-arm CT의 필수 성능평가 기준 마련을 위한 연구)

  • Kim, Eun-Hye;Park, Hye-Min;Kim, Jung-Min
    • Journal of radiological science and technology
    • /
    • v.45 no.2
    • /
    • pp.127-134
    • /
    • 2022
  • In order to overcome the image quality limitations of the conventional C-arm, a flat panel detector (FPD) is used to enhance spatial resolution, detective quantum efficiency, frame rate, and dynamic range. Three-dimensional (3D) visualized information can be obtained from C-arm computed tomography (CT) equipped with an FPD, which can reduce patient discomfort and provide various medical information to health care providers by conducting procedures in the interventional procedure room without moving the patient to the CT scan room. Unlike a conventional C-arm device, a C-arm CT requires different basic safety and essential performance evaluation criteria; therefore, in this study, basic safety and essential performance evaluation criteria to protect patients, medical staff, and radiologists were derived based on International Electrotechnical Commission (IEC) standards, the Ministry of Food and Drug Safety (MFDS) standards in Korea, and the rules on the installation and operation of special medical equipment in Korea. As a result of the study, six basic safety evaluation criteria related to electrical and mechanical radiation safety (leakage current, collision protection, emergency stopping device, overheating, recovery management, and ingress of water or particulate matter into medical electrical (ME) equipment and ME systems: footswitches) and 14 essential performance evaluation criteria (accuracy of tube voltage, accuracy of tube current, accuracy of loading time, accuracy of current time product, reproducibility of radiation output, linearity and consistency in radiography, half layer value in X-ray equipment, focal size and collimator, relationship between X-ray field and image reception area, consistency of light irradiation versus X-ray irradiation, performance of the mechanical device, focal spot to skin distance accuracy, image quality evaluation, and technical characteristic of cone-beam computed tomography) were selected for a total of 20 criteria.

Computed Tomographic Evaluation of Three Canine Patients with Head Trauma (개에서 컴퓨터단층촬영을 이용한 두부 외상의 평가 3례)

  • Kim, Tae-Hun;Kim, Ju-Hyung;Cho, Hang-Myo;Cheon, Haeng-Bok;Kang, Ji-Houn;Na, Ki-Jeong;Mo, In-Pil;Lee, Young-Won;Choi, Ho-Jung;Kim, Gon-Hyung;Chang, Dong-Woo
    • Journal of Veterinary Clinics
    • /
    • v.24 no.4
    • /
    • pp.667-672
    • /
    • 2007
  • This report describes the use of conventional computed tomography(CT) for the diagnosis of head trauma in three canine patients. According to physical and neurologic examinations, survey radiography and computed tomography, these patients were diagnosed as traumatic brain injury. Especially, CT is the imaging modality of first choice for head trauma patients. It provides rapid acquisition of images, superior bone detail, and better visualization of acute hemorrhage than magnetic resonance imaging. It is also less expensive and more readily available. Pre-contrast computed tomography was used to image the head. Then, post-contrast CT was performed using the same technique. The Modified Glasgow Coma Scale(MGCS) score was used to predict their probability of survival rate after head trauma in these dogs. Computed tomogram showed fluid filled tympanic bulla, fracture of the left temporal bone and cerebral parenchymal hemorrhage with post contrast ring enhancement. However, in one case, computed tomographic examination didn't delineate cerebellar parenchymal hemorrhage, which was found at postmortem examination. Treatments for patients placed in intensive care were focused to maintain cerebral perfusion pressure and to normalize intracranial pressure. In these cases, diagnostic computed tomography was a useful procedure. It revealed accurate location of the hemorrhage lesion.

Comparison of CT Image Performance with or without Tin Filter based on Blind Image Quality Evaluation Method (블라인드 품질 평가 방법을 사용한 주석필터 사용 유무에 따른 CT 영상 특성 비교)

  • Shim, Jina;Lee, Youngjin
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.3
    • /
    • pp.301-306
    • /
    • 2021
  • The use of tin filters as a way to reduce the medical radiation in computed tomography (CT). However, due to the changed X-ray spectrum with the use of tin filters, disease diagnosis could be affected because it appears as images of different impressions from previous images. Therefore, this study evaluates the changes in images when using tin filter and high pitch in chest low-dose CT. In this study, images were acquired in groups of three for comparison. Group 1 did not apply to tin filter, and used the existing pitch 0.8. Group 2 used a tin filter, pitch 0.8, Group 3 used a tin filter, and pitch 2.5. To compare the image quality, the natural image quality evaluator (NIQE) and the blind/referenceless image quality evaluator (BRISQUE) were used among the blind quality evaluation factors depended on a no-reference basis. As a result, the NIQE values were low in the order of Group 1, Group 3, and Group 2. BRISQUE values were low in the order of Group 3, Group 2 and Group 1. This study confirms the superiority of images of tin filter and high pitch techniques in chest low-dose CT, which is considered to be a fundamental study for acquiring accurate images of patients with difficult breathing control.

Usability Evaluation of Applied Low-dose CT When Examining Urinary Calculus Using Computed Tomography (컴퓨터 단층촬영을 이용한 요로결석 검사에서 저선량 CT의 적용에 대한 유용성 평가)

  • Kim, Hyeon-Jin;Ji, Tae-Jeong
    • The Journal of the Korea Contents Association
    • /
    • v.17 no.6
    • /
    • pp.81-85
    • /
    • 2017
  • The aim of this study was to evaluate the usability of applied Low dose Computed Tomography(LDCT) protocol in examining urinary calculus using computed tomography. The subjects of this study were urological patients who visited a medical institution located in Busan from June to December 2016 and the protocol used in this study was Adaptive Statistical Iterative Reconstruction: low-dose CT with 50% Adaptive Statistical Iterative Reconstruction (ASIR). As results of quantitative analysis, the mean pixel value and standard deviation within kidney region of image(ROI)of the axial image were $26.21{\pm}7.08$ in abdomen CT pre scan and $20.03{\pm}8.16$ in low-dose CT. Also the mean pixel value and standard deviation within kidney ROI of the coronal image were $22.07{\pm}7.35$ in abdomen CT pre scan and $21.67{\pm}6.11$ in low dose CT. The results of qualitative analysis showed that four raters' mean values of observed kidney artifacts were $19.14{\pm}0.36$ when using abdomen CT protocol and $19.17{\pm}0.43$ in low-dose CT, and the mean value of resolution and contrast was $19.35{\pm}0.70$ when using abdomen CT protocol and $19.29{\pm}0.58$ in low-dose CT. Also the results of a exposure dose analysis showed that the mean values of CTDIvol and DLP in abdomen CT pre scan were 18.02 mGy and $887.51mGy{\cdot}cm$ respectively and the mean values of CTDIvol and DLP when using low-dose CT protocol were 7.412 mGy and $361.22mGy{\cdot}cm$ respectively. The resulting dose reduction rate was 58.82% and 59.29%, respectively.

Automatic Segmentation of Stomach from the CT Image (CT 영상에서 위(Stomach)의 자동적인 추출)

  • 박승란;박종원;노승무
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 1999.10b
    • /
    • pp.428-430
    • /
    • 1999
  • 컴퓨터 단층촬영(Computed Tomography : CT)내의 위(stomach)에 대하여 연구하였다. 위는 모양이 변하면서 움직이는 정기이며 음식물로 채워진 부분과 공기로 채워진 부분으로 나뉘어져 있다. 위의 명암 값 정보와 위치 정보를 이용하여 자동적으로 추출을 한 다음, 음식물로 채워진 부분과 공기로 채워진 부분, 그리고 전체적인 위의 체적을 계산할 수 있는 알고리즘을 구현하였다.

  • PDF