• 제목/요약/키워드: Computational Fluid Dynamics Analysis

검색결과 1,514건 처리시간 0.027초

공기조화, 냉동 분야의 최근 연구 동향 -2000년 및 2001년 학회지 논문에 대한 종합적 고찰 - (Recent Progress in Air Conditioning and Refrigeration Research -A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2000 and 2001-)

  • 강신형;한화택;조금남;이승복;조형희;김민수
    • 설비공학논문집
    • /
    • 제14권12호
    • /
    • pp.1102-1139
    • /
    • 2002
  • A review on the papers published in the Korean Journal of Air-Conditioning and Refrigerating Engineering in 2000 and 2001 has been done. Focus has been put on current status of research in the aspect of heating, cooling, ventilation, sanitation and building environment. The conclusions are as follows. (1) Most of fundamental studies on fluid flow were related with heat transportation of facilities. Drop formation and rivulet flow on solid surfaces were interesting topics related with condensation augmentation. Research on micro environment considering flow, heat, humidity was also interesting for comfortable living environment. It can be extended considering biological aspects. Development of fans and blowers of high performance and low noise were continuing topics. Well developed CFD technologies were widely applied for developing facilities and their systems. (2) Most of papers related with heat transfer analysis and heat exchanger shows dealt with convection, evaporation, and channel flow for the design application of heat exchanger. The numerical heat transfer simulation studies have been peformed and reported to show heat transfer characteristics. Experimental as well as numerical studies on heat exchanger were reported, while not many papers are available for the system analysis including heat exchanger. (3) A review of the recent studies on heat pump system shows that performance analysis and control of heat pump have been peformed by various simulations and experiments. The research papers on multi-type heat pump system increased significantly. The studies on heat pipe have been examined experimently for change of working characteristics and strut lure. Research on the phase change has been carried out steadily and operation strategies of encapsulated ice storage tank are reported experimentally in several papers. (4) A review of recent studies on refrigeration/air conditioning system have focused on the system performance and efficiency for new alternative refrigerants. Evaporation and condensation heat transfer characteristics are investigated for tube shapes and new alternative refrigerants. Studies on components of refrigeration/air conditioning system are carried to examine efficiency for various compressors and performance of new expansion devices. In addition to thermophysical properties of refrigerant mixtures, studies on new refrigerants are also carried out, however research works on two-phase flow seemed to be insufficient. (5) A review of the recent studies on absorption cooling system indicates that heat and mass transfer phenomena have been investigated to improve absorber performance. Various experimental data have been presented and several simulation models have been proposed. A review of the recent studies on duct and ventilation shows that ventilation indices have been proposed to quantify the ventilation performance in buildings and tunnels. Main efforts have been focused on the applications of ventilation effectiveness in practice, either numerically using computational fluid dynamics or experimentally using tracer gas techniques. (6) Based on a review of recent studies on indoor thermal environment and building service systems, research issues have mainly focused on many innovative ideas such as underfloor air-conditioning system, personal environmental modules, radiant floor cooling and etc. Also, the new approaches for minimizing energy consumption as well as improving indoor environmental conditions through predictive control of HVAC systems, various activities of building energy management and cost-benefit analysis for economic evaluation were highlighted.

CFD를 이용한 범포 주위의 유동장 특성 (The characteristics of the flow field around canvas kite using the CFD)

  • 배봉성;배재현;안희춘;박성욱;박창두;정의철
    • 수산해양기술연구
    • /
    • 제42권3호
    • /
    • pp.169-178
    • /
    • 2006
  • This research aims at establishing the fundamental characteristics of the kite through the analysis of the flow field around various types of kites. The approach of this study were adopted for the analysis; visualization by CFD(computational fluid dynamics). Also, the lift/drag and PIV(particle image velocimetry) tests of kites had been performed in our previous finding. For this situation, models of canvas kite were designed by solidworks(design program) for the CFD test using the same conditions as in the lift/drag tests. And we utilized FloWorks as a CFD analysis program. The results obtained from the above approach are summarized as follows: According to comparison of the measured and analyzed results from mechanical tests, PIV and CFD test, the results of all test were similar. The numerical results of lift-coefficient and drag-coefficient were 5-20% less than those of the tests when attack angle is $10^{\circ},\;20^{\circ}\;and\;30^{\circ}$. In particular, it showed the 20% discrepancy at $40^{\circ}$. The numerical results of the ratio of drag and lift were 8-13% less than those of the tests at $10^{\circ}$ and 10% less than those of the tests at $20^{\circ},\;30^{\circ}\;and\;40^{\circ}$. Pressure distribution gradually became stable at $10^{\circ}$. In particular, the rectangular and triangular types had the centre of the high pressure field towards the leading edge and the inverted triangular type had it towards the trailing edge. The increase of the attack angle resulted in the eddy in order of the rectangular, triangular and inverted triangular type. The magnitude of the eddy followed the same order. The effect of edge-eddy was biggest in the triangular type followed by the rectangular and then the inverted triangular type. The action point of dynamic pressure as a function of the attack angle was close to the rear area of the model with the small attack angle, and with large attack angle, the action point was close to the front part of the model.

네트워크형 복층 도로터널 확폭구간에서의 충격손실 계수 결정을 위한 수치해석 연구 (A Numerical Analysis on the Determination of Shock Loss Coefficient at Flared Intersection of Network-type Double-deck Road Tunnel)

  • 박요한;이승준;김진
    • 터널과지하공간
    • /
    • 제28권1호
    • /
    • pp.111-124
    • /
    • 2018
  • 본 연구는 전세계적으로 활발하게 기술 개발 중인 네트워크형 복층 도로터널에서의 환기 설계를 위해 새롭게 요구되는 설계인자를 분석한다. 분류 및 합류부 지점에 존재하는 확폭구간에서 단면적의 변화에 따라 발생하는 충격손실계수를 결정하기 위해 전산유체역학(CFD)를 통한 수치해석 연구를 진행하였다. 수치해석에 사용된 모델은 실제 스케일을 반영하였고 이전의 선행 연구의 충격손실계수 값과의 비교분석을 통해 그 값의 신뢰성을 확보하였다. 수치해석 연구의 결과로 단면적비의 변화에 따른 충격손실계수 값을 도출해냈고 급확대부와 급축소부 두 경우 모두 이전의 선행 연구에서 제시된 충격손실계수 값보다 높게 계산되어졌다. 이는 네트워크형 복층 도로터널의 기하학적 구조의 특성이 충격손실계수에 미치는 영향이 크다고 판단된다. 따라서 본 연구의 결과 값은 앞으로 네트워크형 복층 도로터널의 환기 설계에 있어 좀 더 정확한 설계에 도움이 될 것으로 기대된다.

Analysis of Air Circulation in Oyster Mushroom Farm

  • Jeong, Won-Geun;Lim, Hack-Kyu;Kim, Tae-Han
    • Journal of Biosystems Engineering
    • /
    • 제37권2호
    • /
    • pp.75-81
    • /
    • 2012
  • Oyster mushroom farm which could not meet optimum temperature range yields non-uniform sized, low quality products. Thus, this study, utilizing STAR CCM+, one of the computational fluid dynamics (CFD) programs, analyzed the impact of air circulation and temperature distribution. Methods: After we visited numerous mushroom farms, we measured the temperature at the discharge ports of heaters, fan capacity, and the locations of the air circulators in the farms. According to the data, most mushroom growers installed the heaters near the entrance and discharge ports of the heaters at the third growing bed on the same height as the heaters in the entrance. The temperature at the discharge port of heater was $1,26^{\circ}C$, and the fan capacity was 4,500 $m^3$/hr. The air circulator was placed in the center of the mushroom farm 50cm above the ground, and its capacity of inlet port was 1,100 $m^3$/hr and discharge port 1,600 $m^3$/hr. The mushroom farm was insulated. Results: According to the analysis of the temperature distribution in the vertical plane of the entrance side, no air circulation causes the high temperature zone of 296~299K at the discharge port of the heater to take up 34% of area while the operation of air circulators causes it to occupy only 9%. This means that not using air circulators leads to a concentration of high temperature at the discharge port near the entrance. In addition, with the results of the analysis of the temperature distribution in the vertical planes of the center, no air circulation causes the temperature zone of 295~298K at the discharge port of the heater to take up 48% of area while the operation of air circulators causes it to occupy 80%. This shows that the high outlet port temperature disseminated to the center. Conclusions: After ninety minute operation of both heater and air circulator, the interior temperature became stabilized in the mushroom farm. Air circulation made the high temperature at the discharge port disseminate to the center and exit in the farm and equalize the temperature distribution.

사이드 홀을 가진 케뉼라에 관한 수치해석적 연구 (Numerical Analysis on the Flow in Cannulae having Side Holes)

  • 박중열;박찬영;민병구
    • 대한의용생체공학회:의공학회지
    • /
    • 제25권6호
    • /
    • pp.489-496
    • /
    • 2004
  • 혈액이 케뉼라를 통과할 때 생리적인 범위를 벋어나는 기계적인 하중이나 전단응력을 받게 되며, 그 결과로 용혈의 발생기전이 되는 ADP(Adenosine Diphospate)를 증가 시키게 된다. 저자는 수치해석적인 방법을 이용하여 사이드 홀을 가진 케뉼라의 3차원 유동을 해석하였다. 연구의 대상이 되는 케뉼라는 환자의 대퇴정맥에 삽입되어 혈액을 배출하는 배액 케뉼라이다. 이러한 배액 케뉼라는 배출 성능을 높이기 위해 일반적으로 사이드 홀을 장착한다. 4개, 12개, 20개인 사이드 홀을 가진 케뉼라에 대하여 경우에 대하여, 각각 엇갈림 배열, 직렬 배열. 변형된 직렬배열을 적용하여, 총 9가지 서로 다른 모델을 시뮬레이션 해보았으며 이것을 사이드 홀이 없는 케뉼라와 더불어 비교하였다. 유량, 벽면전단응력(Wail Shear Stress. WSS), 전단율(Shear Rate. SR) 값을 구하여 분석하므로 사이드 홀의 영향을 알아보았다. 연구를 통하여 사이드 홀의 개수와 배열이 모두 혈류 역학적인 변수들에 영향을 주는 것을 확인하였다. 유량이 사이드 홀의 개수에 비례하지 않는 것을 확인 하였고 사이드 홀의 개수가 많을 수로 평균 전단율을 줄이는 것을 확인 하였다.

상판이 없는 직사각형 단면의 미세채널에서 모세관 유동 분석 (Analysis of Capillary Flow in Open-Top Rectangular Microchannel)

  • 박은정;조지용;김정철;허대성;정찬일;김중경
    • 대한기계학회논문집B
    • /
    • 제34권1호
    • /
    • pp.77-82
    • /
    • 2010
  • 소형분석시스템에서 미세채널의 상판이 제거되면 상판에 의한 빛 에너지 손실이 대폭 감소되어 광학측정법으로 대상을 분석할 때 장점을 갖는다. 본 연구에서는 상판이 없는 사각단면 미세채널 내 액체유동을 이해하려는 목적으로 실험과 전산유체역학 해석을 수행하였다. 개방형 사각단면 미세채널에서 입자추적기법으로 유속을 측정하였고, 채널의 단면적 변화에 따른 모세관 유동현상을 이론적으로 해석하였다. 단면의 너비와 높이가 각각 20 ${\mu}m$로 제작된 미세채널의 주입부에 물을 떨어뜨렸을 때 물은 오직 모세관 힘에 의해 미세채널을 따라 이동하였다. 액체의 젖음현상에 영향을 미치는 중요한 유동 파라미터는 채널의 크기와 표면장력, 점성 등으로 볼 수 있으며, 미세채널에서 액체 유동을 조절하는데 이용될 수 있다.

CFD 분석에 의한 느타리버섯 재배사 환경균일성 향상 연구 (The study on enhanced micro climate of the oyster mushroom cultivation house with multi-layered shelves by using CFD analysis)

  • 이성현;유병기;이찬중;임영택
    • 한국버섯학회지
    • /
    • 제15권1호
    • /
    • pp.14-20
    • /
    • 2017
  • 버섯의 단위면적당 생산량을 증대시키기 위하여 다단으로 재배되는 버섯재배사는 재배균상이 내부공기의 유동을 막는 장애물로 작용하여 균상의 아래쪽과 위쪽간의 환경차이가 발생한다. 이러한 환경차이 때문에 버섯재배 균상의 위치에 따른 생육차이가 발생한다. 본 연구에서와 같이 버섯재배사 내부에서 버섯이 생육되지 않는 작업통로의 상단에 천장방향으로 대류팬을 설치하여 운용하면 재배사 내부의 공기를 전체적으로 균일하게 유지할 수 있는 것으로 나타났다. 다만, 버섯재배사 내부에 설치된 각종 환경조절장치 즉 유니트쿨러, 입기팬, 배기팬, 대류팬, 가습기 등이 모두 한꺼번에 가동될 때는 버섯재배 균상위의 RMS 값이 속도 23.86%, 온도 6.08%, 습도 2.72%로 나타났다. 하지만 유니트쿨러와 대류팬이 가동될 때는 균상위의 RMS 값이 속도 23.54%, 온도 0.51%, 습도 0.41%로 나타났다. 따라서 버섯재배사의 환경조절을 위한 입기팬, 배기팬과 가습기는 용량이 큰 것을 설치하여 전체적인 가동시간을 줄이고, 유니트쿨러와 대류팬을 조합한 환경관리 방법이 내부 환경의 균일성 향상에 큰 도움이 될 것으로 판단된다.

압송롤러 드럼베이스의 홀 설계에 따른 페인트 유입양상에 대한 연구 (A Study on the Inflow Pattern of Paint according to the Hole Design of the Drum-base in the Pressure-roller)

  • 정남균
    • 한국산학기술학회논문지
    • /
    • 제21권1호
    • /
    • pp.487-493
    • /
    • 2020
  • 최근 환경부의 강화된 규제로 건축물 아파트 등 산업시설을 도장함에 있어 페인트를 유압에 의해 자동으로 이송시켜 스프레이식으로 도장하는 기존 에어리스 방식의 사용을 금지하였다. 따라서 기존의 에어리스 도장장치에 스프레이 대신 부착하여 사용할 압송롤러개발이 필요한데, 현재 개발되어 판매 중인 압송롤러는 롤러를 구성하는 SUS배관 및 드럼베이스의 홀 설계에 대한 자세한 연구 사례가 없어 그 효율성이 의심이 되는 바이다. 특히, 롤러를 이용한 도장 시롤러 양단에 페인트가 충분히 공급되지 못하면 도장 후 붓을 이용한 재작업이 필요하게 되므로, 롤러 양단에 페인트가 잘 유입될 수 있도록 드럼베이스 홀을 분포시킬 필요가 있다. 본 연구에서는 SUS배관 및 드럼베이스에 가공되는 홀의 형태가 페인트의 유입양상에 미치는 영향을 알아보고 보다 효율적인 홀 설계 방안을 제시하기 위하여 SUS배관 및 롤러에 대하여 전산유체해석을 수행하였다. 해석결과 SUS배관에서의 홀 배치는 배관에 균일하게 배치하는 것이 균형 있게 페인트를 유입시키기에 좋고, 드럼베이스의 경우는 홀을 드럼베이스 양단에 밀집하여 가공하면 페인트가 롤러 양단에 더 잘 유입시킬 수 있음이 검증되었다.

FDS와 GIS를 이용한 교량 화재 위험도의 정량적 평가 및 적용방안 (Quantitative Fire Risk Assessment and Counter Plans Based on FDS and GIS for National Road Bridges)

  • 안호준;박철우;김용재;장영익;공정식
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제21권6호
    • /
    • pp.185-195
    • /
    • 2017
  • 최근 교통과 물류의 발달과 함께 위험물 수송의 증가와 교통량의 증가로 인하여, 주요한 사회기반시설물 중 하나인 교량에 대하여 예상하지 못한 화재사고 화재 발생이 증가하는 추세이다. 또한, 교량 하부 공간의 효율적인 사용에 대한 요구가 늘어남에 따라, 하부에 유조차 및 화물차 등의 위험물질이 적치되는 비율이 증가하고 있으며, 앞서 기술한 이유들로 인하여 최근 교량의 화재 발생 위험성이 급격히 증가하고 있다. 하지만, 이러한 피해를 줄이기 위해, 교량에 대한 화재 위험도 평가가 수행된 사례가 있으나, 사용자의 관점에서 안전성을 고려한 실용적으로 위험도를 평가할 수 있는 모델이 부족하다. 이에 본 연구에서는 국도교량에 적용 가능한 정량적인 위험도 평가모델을 제시하였다. 교량의 화재위험도에 큰 영향을 미치는 형하고, 화재강도, 교량의 재료, 소방차량 도착시간 등을 주요인자들로 선정하였으며, 선정된 인자들을 FDS에 반영하여 화재강도와 지속시간에 따른 각 교량의 최고 온도를 산출하였다. FDS 해석결과와 위험도 등급기준, 소방차량 도착시간을 반영한 화재 위험도 평가 모델과 위험도에 따른 대응방안을 수립하였다. GIS의 네트워크 분석기능을 통해 소방서에서 교량까지의 도착시간을 예시적으로 산출하였으며, 이를 통해 예시적인 교량의 위험도 등급을 평가하고, 그에 따른 대응방안을 제안하였다.

선박의 엔드라인 폭연방지기의 요소기술에 관한 연구 (A Study on the Element Technologies in Flame Arrester of End Line)

  • 팜민억;최민선;김부기
    • 해양환경안전학회지
    • /
    • 제25권4호
    • /
    • pp.468-475
    • /
    • 2019
  • 엔드라인 폭연방지기는 수직 환기장치에 폭연방지와 함께 대기방출을 하도록 한다. 엔드라인 폭연방지장치는 선박과 같은 산업현장의 다양한 분야에 적용된다. 폭연방지기에서 스프링은 스프링 부하와 스프링의 탄성이 후드 개방 모멘트를 결정하므로 필수 부품이다. 더욱이, 장치 내 스프링은 고온의 상태에서도 작동해야 한다. 따라서, 폭연이 나타나기 시작할 때 스프링의 기계적 하중과 탄성을 분석할 필요가 있다. 이 연구에서는 엔드라인 폭연방지기의 작동 프로세스의 시뮬레이션을 기반으로 열 및 구조해석을 수행하으며, 스프링의 3차원 모델은 CFD 시뮬레이션을 이용하였다. CFD 해석은 FEM 시뮬레이션 값을 입력하여 스프링 구조를 분석한다. 본 연구에서는 스프링 부하의 43 kg, 93 kg 및 56 kg 세 가지 경우 즉, 150 mm 스프링 디플렉션에 부합하도록 집중적으로 관찰하였다. 결과적으로, $1,000^{\circ}C$ 가열조건 하에서 5분 후에 스프링 부하가 10 kg 감소했다. 시뮬레이션 결과는 연소 시간 변화에 따라 스프링의 부하와 탄성을 예측하고 추정할 수 있었다. 또한, 연구의 결과는 폭연방지기의 제조자들에게 역화방지장치뿐만 아니라 스프링의 설계를 최적화하기 위한 참고 자료로 활용할 수 있다.