• 제목/요약/키워드: Compressor valve leakage

검색결과 8건 처리시간 0.023초

Analysis of leakage factors affecting ECV performance in variable compressor

  • Mahmud, Md. Iqbal;Cho, Haeng Muk
    • 에너지공학
    • /
    • 제23권4호
    • /
    • pp.183-188
    • /
    • 2014
  • Solenoid operated electromagnetic control valve (ECV) using in an external variable displacement swash plate type compressor is widely used for air conditioning control system because of its low energy consumption and high efficient characteristics. ECV controls the entire vehicle air conditioning system by means of a pulse width modulation (PWM) system that supplied from an external controller. Different pressure ports located within ECV has important functions to control the air/refrigerant flow through its internal passages. The flow paths are preciously maintained with acceptable ranges of leakage (gap) between the parts inside it which is followed by effective design and critical dimensioning of its internal features. Therefore, it saves energy losses from the solenoid operation as well as ensures the balance of forces within it. The research paper highlights analysis of the leakages (at different pressure ports) and dimensioning tolerance factors that affects the ECV performance.

압축기 토출벨브의 유체-구조 연계해석 및 충돌해석 (Flow Structure Interaction 3-D Reciprocating Compressor and Impact Analyses of Compressor Discharge Valve)

  • 레사 옥타비안티;김동현;박강균;정원현;안재우;문경호;고영필;김형식
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 춘계학술대회논문집
    • /
    • pp.633-640
    • /
    • 2007
  • In this paper, 3-D reciprocating compressor is taken into flow-structure interaction analysis. The full cycle process consisted of cylinder expansion and compression has been modeled without considering flow leakage through cylinder wall. Fully-coupled FSI analysis of this compressor model was iteratively solved and gives sufficient result with the experimental test. The study is emphasized to thoroughly investigate discharge valve motion, opening and closing, in order to determine discharge valve region which is prone to have high effective stress. The cylinder pressure is successfully validated before conducting impact analyses between discharge valve and other susceptible supported structure. Velocity profile has been obtained in FSI analysis is used as initial condition to carry out further impact analyses. Stress result of discharge valve and valve spring gives preliminary estimation of higher stress area due to its impact phenomena.

  • PDF

천연가스 차량용 체크밸브의 내구성능에 관한 연구 (A Study on Durability Test of Check Valve for CNG Vehicles)

  • 김창기;이선엽;조규백
    • 한국가스학회지
    • /
    • 제13권6호
    • /
    • pp.15-20
    • /
    • 2009
  • 대도시 대기질 개선을 위한 정부 정책에 의해 1990년대 이후 천연가스 차량의 보급 대수는 계속 증가하고 있다. 그러나 천연가스 차량은 환경면에서 유리한 대신 화재 발생 시 대형 사고가 잠재하므로 항상 안전에 대한 대책이 요구된다. 천연가스 차량에 장착되는 여러 가지 연료 부품 중 체크밸브는 연료용기에 충전된 고압의 천연가스가 연료주입구를 통해 외부로 방출되지 않도록 하는 안전장치로서 반 복사용에 따른 내구성이 보장되어야 하는 부품이다. 본 연구에서는 천연가스 차량용 체크밸브를 대상으로 반복 사용시험, 극한 떨림시험에 따른 내구성능과, 압축기 오일에 의한 밸브 씰의 영향을 평가하였다. 실험 결과 천연가스 차량에 사용되고 있는 체크밸브는 인증규정을 만족하였지만 압축기 오일에 오랫동안 노출될 경우 밸브 씰의 누설방지 기능에 문제를 발생시킬 수 있음을 확인할 수 있었다.

  • PDF

신경망무고장모델과 이중퍼지로직을 사용한 냉방기 고장진단 알고리즘 (Fault Diagnosis Algorithm of an Air-conditioning System by using a Neural No-fault Model and a Dual Fuzzy Logic)

  • 한도영;정남철
    • 설비공학논문집
    • /
    • 제18권10호
    • /
    • pp.791-799
    • /
    • 2006
  • The fault diagnosis technologies may be applied in order to decrease the energy consumption and the maintenance cost of an air-conditioning system. In this paper, a fault diagnosis algorithm was developed by using a neural no-fault model and a dual fuzzy logic. Five different faults, such as the compressor valve leakage, the liquid line blockage, the condenser fouling, the evaporator fouling, and the refrigerant leakage of an air-conditioning system, were considered. The fault diagnosis algorithm was tested by using a fault simulation facility. Test results showed that the algorithm developed for this study was effective to detect and diagnose various faults. Therefore, this algorithm may be practically used for the fault diagnosis of an air-conditioning system.

냉장고 사이클 특성에 미치는 열손실량의 영향 (Effect of heat Leak on Cycle Characteristics of Refrigerator)

  • 신진규
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제22권6호
    • /
    • pp.871-879
    • /
    • 1998
  • The refrigerator consists of many components such as compressor condenser expansion valve evaporator and the cabinet which filled by urethane foam. In this paper the heat leakage of refriger-ator is measured by the new experiment method which is different from a present method, The devi-ation of the UA(overall heat transfer coefficient times area) between the simulation and experiments is about 7-8%. Using the modeling of various components of refrigeration system a performance analysos of CFC 12 and HFC 134a is performed numerically on the UA. As the results of this study according to increase the heat leakage the refrigeration load and mass flow rate of refrigerant are increased. And the increase of the mass flow rate results in the increase of the condensing and evapo-rating temperature. Therefore according to increase of the heat leakage the COP leads to increase because the increase of refrigeration capacity is larger than the increase if compressor power.

  • PDF

잔차입력 RBF 신경망을 사용한 냉방기 고장검출 알고리즘 (The Fault Detection of an Air-Conditioning System by Using a Residual Input RBF Neural Network)

  • 한도영;류병진
    • 설비공학논문집
    • /
    • 제17권8호
    • /
    • pp.780-788
    • /
    • 2005
  • Two different types of algorithms were developed and applied to detect the partial faults of a multi-type air conditioning system. Partial faults include the compressor valve leakage, the refrigerant pipe partial blockage, the condenser fouling, and the evaporator fouling. The first algorithm was developed by using mathematical models and parity relations, and the second algorithm was developed by using mathematical models and a RBF neural network. Test results showed that the second algorithm was better than the first algorithm in detecting various partial faults of the system. Therefore, the algorithm developed by using mathematical models and a RBF neural network may be used for the detection of partial faults of an air-conditioning system.

곡물냉각기를 이용한 철제 원형빈에서 벼 냉각 (Field Cooling Tests of Paddy Stored in Steel Bins with a Grain Cooler)

  • 김의웅;김동철
    • 한국식품저장유통학회지
    • /
    • 제11권2호
    • /
    • pp.263-268
    • /
    • 2004
  • 곡물냉각기를 이용하여 벼의 냉각특성을 구명하기 위하여 RPC의 원형빈에서 2회의 냉각실험을 실시하였다. 1차 냉각 실험은 하절기에 200 톤 규모의 원형빈에서, 2차 냉각실험은 수확기에 300 톤 규모의 원형빈에 저장된 벼를 대상으로 실시하였다. 그 결과를 요약하면 다음과 같다. 1차 냉각실험에서 초기곡온 23.6$^{\circ}C$, 함수율 19.3%인 벼180.3 톤을 14$^{\circ}C$까지 냉각시키는데 52.5시간이 소요되었으며, 냉각을 통해 함수율은 약 0.6% 감소하였다. 또한, 2차 냉각실험에서 초기곡온 16.1$^{\circ}C$, 함수율 19.2%인 벼 272.2 톤을 5.5$^{\circ}C$까지 냉각시키는데 78.0시간이 소요되었다. 1, 2차 냉각실험에서 냉각공기온도를 각각 8.0, 5.5$^{\circ}C$로 설정하였을 때, 곡물냉각기출구의 냉각공기온도는 각각 8.0$\pm$0.48$^{\circ}C$, 5.7$\pm$0.84$^{\circ}C$로서 정밀하게 제어되고 있음을 알 수 있었으며, 2차 냉각실험에서의 온도편차가 1차 냉각실험에서보다 높게 나타난 것은 냉각부하가 적었고, 외기조건이 급격하기 변화하여 압축기 무부하전자변, 재열기 및 증발기에 공급되는 고온고압 냉매가스량, 응축기 송풍기가 제어되었기 때문으로 판단되었다. 1차 냉각실험에서 곡물냉각기에서 냉각된 공기량은 평균77.5㎥/min인데 비해 곡물층을 통과한 냉각공기량은 42.5㎥/min에 불과해 약 45%의 냉각공기가 누설되어 이에 대한 방지책이 필요하였다. 냉각부하가 큰 하절기에 실시한 1차 냉각실험에서는 댐퍼만이 제어되었으며, 소요전력은 평균 22.1㎾를 나타낸 반면, 냉각부하가 적은 수확기에 실시한 2차 냉각실험에서는 압축기의 무부하전자변, 응축기 송풍기 등이 제어되었으며, 소요전력은 평균 17.4㎾로 나타나 하절기에 비하여 약 27%정도의 에너지가 절감된 것으로 나타났다.