• Title/Summary/Keyword: Compressor power input

Search Result 52, Processing Time 0.023 seconds

Thermal Performance Analysis of Reciprocating Compressors for Refrigerator-freezers (냉장고용 왕복동 압축기의 성능 해석)

  • KIM, MAN-HOE
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.27 no.2
    • /
    • pp.236-243
    • /
    • 2016
  • This paper presents a simple thermo-physical model of reciprocating compressors for household refrigerator-freezers. The compressor model has been developed based on thermodynamic principles and large data sets from the compressor calorimeter tests. The input data are compressor geometry (displacement and clearance volume), compressor speed, suction pressure and temperature, discharge pressure, and ambient temperature. The model can estimate mass flow rate and compressor power consumption within 3.0% accuracy, which is not much larger than measurement errors associated with calorimeter testing under ideal conditions.

High-Performance Multiplier Using Modified m-GDI(: modified Gate-Diffusion Input) Compressor (m-GDI 압축 회로를 이용한 고성능 곱셈기)

  • Si-Eun Lee;Jeong-Beom Kim
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.18 no.2
    • /
    • pp.285-290
    • /
    • 2023
  • Compressors are widely used in high-speed electronic systems and are used to reduce the number of operands in multiplier. The proposed compressor is constructed based on the m-GDI(: modified gate diffusion input) to reduce the propagation delay time. This paper is compared the performance of compressors by applying 4-2, 5-2 and 6-2 m-GDI compressors to the multiplier, respectively. As a simulation results, compared to the 8-bit Dadda multiplier using the 4-2 and 6-2 compressor, the multiplier using the 5-2 compressor is reduced propagation delay time 13.99% and 16.26%, respectively. Also, the multiplier using the 5-2 compressor is reduced PDP(: Power Delay Product) 4.99%, 28.95% compared to 4-2 and 6-2 compressor, respectively. However, the multiplier using the 5-2 compression circuit is increased power consumption by 10.46% compared to the multiplier using the 4-2 compression circuit. In conclusion, the 8-bit Dadda multiplier using the 5-2 compressor is superior to the multipliers using the 4-2 and 6-2 compressors. The proposed circuit is implemented using TSMC 65nm CMOS process and its feasibility is verified through SPECTRE simulation.

Conceptual Design of the Scroll Air Compressor for Fuel Cell (연료전지용 스크롤 공기압축기 개념설계)

  • Kwon, Tae-Hun;Ahn, Jong-Min;Kim, Hyun-Jin;Shim, Jae-Hwi
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.2
    • /
    • pp.113-120
    • /
    • 2008
  • Potential application of the scroll type machine to air compressor for fuel cell has been studied. Among the seven configuration factors which determine scroll wrap profile, the wrap thickness and the orbiting radius were chosen as two independent variables to generate various scroll wrap profiles. A conceptual design practice was conducted for scroll air compressor for SOFC with power output of 2 kW. With larger wrap thickness and orbiting radius, base plate area of the orbiting scroll becomes smaller, so is the axial gas force acting on the base plate, resulting in reduced thrust loss in spite of larger friction velocity. Performance analysis on the designed model showed that its total efficiency was 64.4% with the mass flow rate per unit compressor input of 0.00905 kg/(s kW) for the wrap thickness of 3.5 mm and the orbiting radius of 3.0 mm.

Performance Analysis on the Variable Speed Scroll Compressor with Operating Conditions (가변속 스크롤 압축기의 운전조건의 변화에 따른 성능 해석)

  • 박홍희;박윤철;김용찬
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.7
    • /
    • pp.649-658
    • /
    • 2000
  • Thermodynamic modeling of low-pressure scroll compressor was developed by combining continuity and energy conservation equation. Suction gas heating was considered using energy balance inside the low pressure shell. Pressure, temperature and mass of refrigerant-22 as a function of orbiting angle were calculated by solving the governing equations using fourth order Rung-Kutta scheme. Motor efficiency was taken by experiments with a variation of frequency. The developed model was applied to the analysis of an inverter driven scroll compressor with a variation of frequency, pressure ratio and operating conditions. The model was verified with the experimental results at the same operating conditions. The developed model was adequate to predict performance of the inverter driven scroll compressor as a function of operating conditions. Calculated parameters from the model were discharge temperature, mass flow rate, power input, COP, and thermodynamic properties with respect to orbiting angle. To enhance the performance of a scroll compressor, it is essential to diminish leakage at low frequency level and improve the mechanical efficiency at high frequency level.

  • PDF

Experimental Study on the Performance of Refrigeration Cycle for various RPM of Inverter Scroll Compressor (전동 스크롤압축기의 운전rpm에 따른 냉동사이클의 성능에 대한 실험적 연구)

  • Lee, K.S.;Lee, K.A.;Lee, H.Y.;Lee, Y.S.;Kim, Jeongbae
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.3
    • /
    • pp.42-48
    • /
    • 2014
  • An experimental study was performed estimating COP(Coefficient of Performance) of air-conditioning cycle with inverter scroll compressor. All experiments were done for various compressor speeds from 1000~4000 rpm and used the inverter controller called CANDy to change the compressor rpm. The air-conditioning cycle components in the apparatus were used as same with components of YF hybrid car. To estimate the COP, this study measured the temperature and pressure at inlets and outlets of compressor, condenser, and evaporator. And also measured the compressor input power using Powermeter. Through the experiments, the maximum error to estimate COP was shown about ${\pm}6.09%$ at 3500rpm. This study revealed that the condenser temperature and pressure were increased and the evaporator temperature and pressure were decreased with the increased compressor speed. And also, the COP was decreased with increased compressor speed. Those results can be used the basic and fundamental data to design the air-conditioning cycle with inverter scroll compressor.

The Experimental Study of the Performance of the Rotary Stirling refrigerator (회전압축기형 스털링냉동기의 성능에 관한 실험적 연구)

  • Hong, Yong-Ju;Park, Seong-Je;Kim, Hyo-Bong;Kim, Yang-Hoon;Choi, Young-Don
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.1312-1316
    • /
    • 2004
  • The Stirling refrigerators have been widely used for the cooling of the infrared detector and HTS to the cryogenic temperature. The Stirling refrigerator with the rotary compressor are applicable to the cooling device for the compact mobile thermal imaging system, because the refrigerators have the compact structure and light weight. The typical performance factors of the Stirling refrigerator are the cool-down time, cooling capacity at the desired temperature and the input power. And the above performance factors are depends on the thermal insulation characteristics of the Dewar. In this study, the steady thermal load of the Dewar and the performance of the Stirling refrigerator were measured. The results show the dependency of the input power and the charging pressure on the performance of the refrigerator.

  • PDF

DC Voltage Balancing Control of Half-Bridge PWM Inverter for Liniear Compressor of Refrigerator (냉장고의 선형압축기 구동을 위한 단상 하프브리지 인버터 시스템에서 직류단 불평형 보상에 관한 연구)

  • Kim, Ho-Jin;Kim, Hyeong-Jin;Kim, Dong-Youn;Kim, Jang-Mok
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.22 no.3
    • /
    • pp.256-262
    • /
    • 2017
  • This paper presents the control algorithm of a single-phase AC/DC/AC PWM converter for the linear compressor of a refrigerator. The AC/DC/AC converter consists of a full-bridge PWM converter for the control of the input power factor and a half-bridge PWM inverter for the control of the single-phase linear compressor. At the DC-link of this topology, two capacitors are connected in series. These DC-link voltages must be balanced for safe operation. Thus, a new control method of DC voltage balancing for the half-bridge PWM inverter is proposed. The balancing algorithm uses the Integral-Proportional controller and inserts the DC-offset current at the Proportional-Resonant current controller of the inverter to solve the DC-link unbalanced voltages between the two capacitors. The proposed algorithm can be easily implemented without much computation and additional hardware circuit. The usefulness of the proposed algorithm is verified through several experiments.

A Study on Stirling Cryocooler for Precooling Hydrogen Liquefier (수소액화 예냉용 소형 스털링 극저온 냉동기 특성 연구)

  • PARK, SEONGJE;KO, JUNSEOK;HONG, YONGJU;KIM, HYOBONG;YEOM, HANKIL;IN, SEHWAN
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.27 no.6
    • /
    • pp.651-659
    • /
    • 2016
  • Korea Institute of Machinery & Materials (KIMM) has developed a high efficient Stirling cryocooler with moving magnet linear compressor for precooling hydrogen liquefier and cooling high temperature superconductor (HTS) devices, such as superconductor cable and superconductor fault current limiters. Hydrogen liquefier and HTS electric devices require cryocooler with cooling capacity of hundred watts to kilowatts at 77 K. The compressor in the Stirling cryocooler uses opposed moving magnet linear motors to drive opposed pistons. High efficient Stirling cryocooler is designed by SAGE-software, manufactured and tested systematically. A cooling capacity of 1 kW at 77 K with an electric input power of 9.6 kW has been analyzed. But prototype test results of the Stirling cryocooler have the cooling capacity of 0.65 kW at 76.8 K with an electric input power of 8.1 kW. And then, 21.5% Carnot COP (Coefficient of performance) of the prototype Stirling cryocooler is achieved. The comparison analysis between SAGE-model and experimental results has shown the direction for further design optimization of the Stirling cryocooler.

Effects of Vapor Injection on a Compressor in a Transcritical CO2 Cycle (초임계 CO2 사이클에서 가스 인젝션이 압축기 성능에 미치는 영향)

  • Kim, Woo-Young;Shim, Jae-Hwi;Lee, Yong-Ho;Kim, Hyun-Jin
    • The KSFM Journal of Fluid Machinery
    • /
    • v.10 no.2 s.41
    • /
    • pp.16-21
    • /
    • 2007
  • Potential advantages of using vapor injection in a two stage rotary compressor for a $CO_2$ heat pump water heater system were addressed in this paper by numerical simulation. Vapor separated from a flash tank in the middle of the expansion process can be used for injection into the second stage suction plenum of the compressor to improve the system performance. Vapor injection increases the intermediate pressure between the two stages, thus increasing the first stage compressor work and reducing that of the second stage. As a whole, however, the compressor input power increases due to injected mass flow rate for the second stage. Computer simulation showed that increment of the cooling capacity by vapor injection exceeded that of the compressor work, thus improving the system performance. COP improvement by vapor injection was calculated to be about 5-14% for normal operating conditions. With vapor injection, a maximum COP was found when the displacement volume of the second stage becomes 90-95% of that of the first stage of the compressor.

Gas Pulsation Analysis in a T-Shaped Suction Passage of a CO2 Twin Rotary Compressor (CO2 트윈 로타리 압축기의 흡입관로에서의 가스맥동 해석)

  • Kim, Woo-Young;Ahn, Jong-Min;Kim, Hyun-Jin;Cho, Sung-Oug
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.8
    • /
    • pp.549-555
    • /
    • 2011
  • For a $CO_2$ one-stage twin rotary compressor, a T-shaped suction port was used to effectively supply the suction gas stream into two individual suction chambers of the twin cylinders. Suction gas pulsations were observed in the pressure sensor signals and these were simulated by using the acoustic modeling of Helmholz resonators in parallel. The module of acoustic modeling was combined to a computer simulation program for the compressor performance. Validation of the simulation program has been carried out for a bench model compressor in a compressor calorimeter. Cooling capacity and the compressor input power were reasonably well compared between the simulation and the calorimeter test. Particularly, good agreement on P-V diagram between the simulation and the test was obtained.