A Study on Electronically Controlled R-134a Heat Pump System for a Fuel Cell Electric Vehicle (FCEV) (연료전지 자동차용 R-134a 전동식 히트펌프 시스템 개발에 관한 연구)

  • Lee, Jun-Kyoung;Lee, Dong-Hyuk;Won, Jong-Phil
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.15 no.3
    • /
    • pp.124-132
    • /
    • 2007
  • The main objective of this work is to investigate the characteristics of a heat pump system for fuel cell electric vehicle (FCEV). The present heat pump system adopts an electrically driven compressor running with R134a and uses the heat from the fuel cell stack as the heat source for the exterior heat exchanger. The experimental work has been done with various operating conditions such as different compressor speeds, fuel cell stack coolant temperatures and flow rates. The heating capacity was measured to be from 4 to 10 kW at $-20^{\circ}C$ ambient temperature, and the outlet temperature of interior heat exchanger was up to $70^{\circ}C$. After 30 seconds from start-up, the system reached a steady state and the heating capacity of 6.8 kW was acquired, and after 90 seconds, the air outlet temperature of interior heat exchanger became $35^{\circ}C$.

Performance Characteristics of Water-Chilling Heat Pump Using CO2 on the Variation of Secondary Fluid Conditions (2차 유체 조건 변화에 대한 CO2용 수냉식 열펌프의 성능 특성에 관한 연구)

  • Son, Chang-Hyo;Oh, Hoo-Kyu
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.31 no.5
    • /
    • pp.543-551
    • /
    • 2007
  • The performance characteristics of water-chilling heat pump using $CO_2$ with respect to variation of inlet temperature and mass flow rate of secondary fluid was investigated experimentally. An experimental apparatus is consisted of a compressor, a gas cooler, an expansion valve, an evaporator and a liquid receiver. All heat exchangers used in the test rig are counter-flow-type heat exchangers with concentric dual tubes, which ate made of copper. The gas cooler and the evaporator consist of 6 and 4 straight sections respectively arranged in parallel, each has 2.4 m length. The experimental results were summarized as the followings : As inlet temperature of secondary fluid in the gas cooler increases from $10^{\circ}C$ to $40^{\circ}C$, the compressor work, heating capacity and heating COP were varied to 37.8%, -13%, -35.9%, respectively. The heating capacity, compressor work, heating COP were turned into 23.3%, 6.42%, 13.1%, respectively when ass flow rate of secondary fluid in the evaporator increases from 70 g/s to 150 g/s. The above tendency is similar with performance variation with respect to temperature variation of secondary fluid in the conventional vapor compression cycle.

Representative Bench Marks for CFD of Centrifugal Compressors (원심 압축기의 CFD를 위한 대표적인 Bench Mark)

  • Oh, JongSik
    • 유체기계공업학회:학술대회논문집
    • /
    • 1999.12a
    • /
    • pp.147-160
    • /
    • 1999
  • The importance of CFD work in the process of turbomachinery development has been continuously growing. It is therefore necessary to have some bench marks for validation purposes when any CFD codes are to be developed. In the present study, some public information on centrifugal compressor test results is collected to render useful data for the developers.

  • PDF

Study on Thermodynamic Performance of Electrochemical Hydrogen Compressor (전기화학적 수소 압축기의 열역학적 성능에 관한 연구)

  • TEAHEON KIM;DONGYUN KIM;DONGKEUN LEE;YOUNGSANG KIM;KOOKYOUNG AHN;YONGGYUN BAE;JINYOUNG PARK;YOUNG KIM
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.34 no.2
    • /
    • pp.141-148
    • /
    • 2023
  • The thermodynamic performance of the electrochemical hydrogen compressor was analyzed to perform a comparative analysis with the performance of the mechanical compressor. The performance was analyzed through the applied current and the measured voltage value. The test results showed that the efficiency of the electrochemical hydrogen compressor was high in the low current density range. In addition, it was confirmed that the amount of increasing compress work of the electrochemical hydrogen compressor is smaller than that of the mechanical compressor. Therefore, it is expected to have higher efficiency than mechanical compression when compressed with a sufficiently high-pressure range.

Effect on Heat Exchangers Efficiency on Performance of Cryogenic Refrigeration Cycles (열교환기 효율이 초저온 냉동사이클 성능에 미치는 영향)

  • Yoon, Jung-In
    • Journal of Power System Engineering
    • /
    • v.17 no.4
    • /
    • pp.58-63
    • /
    • 2013
  • This paper presents the new cascade liquefaction cycles using $CO_2-C_2H_6-N_2$ and $CO_2-N_2O-N_2$. The performance of the cascade liquefaction cycles with respect to temperature differences in the LNG heat exchangers is analyzed using HYSYS software and then compared the performance of these cycles with phillips optimized cascade liquefaction cycle. The coefficient of performance of the new liquefaction cycles considered in this study decreases with the temperature differences in the LNG heat exchangers, but the compressor work, expander work and heat capacity in the LNG heat exchanger increases, respectively. From the comparison of performance of three cycles, the cascade liquefaction cycles using $CO_2-C_2H_6-N_2$ showed the highest COP. And the cycles using $CO_2-C_2H_6-N_2$ and $CO_2-N_2O-N_2$ presented the second and third highest COP, respectively. In the view of performance, the optimized cascade liquefaction cycle using $C_3H_8-C_2H_4-C_1H_4$ yields much better COP. But, in the environment view, it is found that the cascade liquefaction cycle using $CO_2-C_2H_6-N_2$ shows favorable characteristics.

The pressure drop characteristics in LNG heat exchanger of cryogenic cascade refrigeration cycle (초저온 캐스케이드 냉동사이클의 LNG 열교환기 압력강하 특성)

  • Yoon, J.I.;Choi, K.H.;Kwag, J.W.;Son, C.H.;Baek, S.M.
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2012.03a
    • /
    • pp.376-381
    • /
    • 2012
  • Natural gas is converted in to LNG by chilling and liquefying the gas to the temperature of $-162^{\circ}C$, when liquefied, the volume of natural gas is reduced to 1/600th of its standard volume. This gives LNG the advantage in transportation. The pressure dorp of the cascade liquefaction cycle was investigated and simulated using HYSYS software. The simulation results showed that the pressure drop in the LNG heat exchanger is set to 50 kPa considering the increase in the compressor work of cryogenic cascade liquefaction cycle.

  • PDF

Performance Analysis of Air Turbo Ramjet using $H_2$ and $CH_4$ (수소와 메탄 연료를 사용한 에어 터보 램제트 엔진의 성능해석)

  • 이양지;차봉준;양수석;이대성;김형진
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.6 no.3
    • /
    • pp.103-110
    • /
    • 2003
  • The present work was conducted to achieve the better understanding of the performance analysis technique for the expander type air turbo ramjet engine. For this purpose, the performance analysis was carried out using a small engine(8.0kN thrust) with two types of fuels. From this analysis, at the same input condition, the thrust of methane-fueled engine was 25% lower than that of hydrogen. In addition, the case of methane shows the inapplicable engine performance cycle.(i.e., The compressor work exceeds the turbine output power) These results come mainly from the different heating value of each fuel and specific heat. This analysis also shows that, to build a same performance cycle as the hydrogen case, the methane-fueled engine requires increased air and fuel flow rates, increased turbine expansion ratio, and decreased compressor pressure ratio.

Performance Characteristics of R134a Supercritical Heat Pump (R134a 냉매용 초임계 히트펌프의 성능 특성)

  • Choi, In-Soo
    • Journal of Power System Engineering
    • /
    • v.18 no.4
    • /
    • pp.60-65
    • /
    • 2014
  • In this paper, cycle performance analysis for heating capacity, compression work and COP of R134a supercritical heat pump is presented to offer the basic design data for the operating parameters of the system. The operating parameters considered in this study include superheating degree, pressure and outlet temperature of gas cooler, compressor efficiency and evaporating temperature in the R134a supercritical heat pump system. The main results were summarized as follows : Superheating degree, pressure and outlet temperature of gas cooler, compressor efficiency and evaporating temperature of R134a heat pump system have an effect on the heating capacity, compression work and COP of this system. With a thorough grasp of these effect, it is necessary to design the supercritical heat pump using R134a. The prediction for COP of R134a supercritical heat pump have been proposed through multiple regression analysis.

A Study on the Structure-borne Noise Reduction of Refrigerators Using Taguchi Method (다구찌 기법을 이용한 냉장고의 구조진동음 저감 방법에 관한 연구)

  • Son, Sol-San;Seo, Jea-Young;Lee, Boo-Youn;Kim, Won-Jin
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.20 no.5
    • /
    • pp.470-476
    • /
    • 2010
  • In this work, the mechanism of structure-borne noise resulting from vibration of a compressor for a refrigerator is experimentally analyzed and an effective method is proposed to reduce the noise. Firstly, the emission noise, when the compressor is turned on and off, is measured and analyzed to identify the generation mechanism of structure-borne noise. And the acceleration on the outer wall of the refrigerator is also analyzed to identify the distribution of vibration. Secondly, an effective design method to reduce the noise is suggested by using the finite element analysis and Taguchi method. Consequently an optimal design of the refrigerator, which has lower noise, is obtained and then its performance and validity are verified through the analysis and test.

Effects of Blade Back Sweep Angle on the Performance and Flow Field in a Centrifugal Compressor (블레이드 후향각이 원심압축기의 성능과 유동에 미치는 영향)

  • Jung, Yohan;Baek, Je Hyun;Park, Jun Young;Choi, Minsuk
    • The KSFM Journal of Fluid Machinery
    • /
    • v.16 no.2
    • /
    • pp.48-53
    • /
    • 2013
  • This paper presents a numerical investigation of the influence of the blade back sweep angle on the performance and flow characteristics in a centrifugal compressor with a vaneless diffuser. Five impellers with different back sweep angles were tested in the flow simulations. It was found that a low back sweep angle could improve the total-to-total pressure ratio and the work coefficient over whole operating ranges. However, the flow field in an impeller with a low back sweep angle produced a more non-uniform velocity distribution at the impeller exit because the wake region was significantly increased. As a consequence, the impeller with a low back sweep angle caused a low diffuser performance.