• 제목/요약/키워드: Compressive test

검색결과 3,609건 처리시간 0.032초

남극 및 시베리아 흙의 동토공학적 특성 분석 (Engineering Characteristics of Antarctic and Siberian Frozen Soils)

  • 김영진;신재원;김현기
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 춘계 학술발표회 초청강연 및 논문집
    • /
    • pp.894-904
    • /
    • 2008
  • In this study, soil samples from the Antarctic and Vladivostok, Siberia were tested in the laboratory, and specific gravity, compaction curve and grain size distribution were determined. The effect of temperature change on the thermal conductivity, unfrozen water content and compressive strength were investigated. Samples for the compressive strength test were prepared in a mold with a fixed volume to prevent swelling and the effect of temperature and water content change on the strength were compared. Results from the thermal conductivity test showed that thermal conductivity values for both soils were larger at temperatures below freezing than above freezing. The unfrozen water content dropped sharply within a temperature range of $0{\sim}-5^{\circ}C$ and then gradually decreased further up to $-20^{\circ}C$. Compressive strength test results showed various stress/deformation curves with a change in water content. Sandy soil had much larger strength than pure ice at an identical temperature, while clayey soil had a smaller strength than ice near the freezing point, but showed a larger strength at temperatures belows $-15^{\circ}C$.

  • PDF

Developments of double skin composite walls using novel enhanced C-channel connectors

  • Yan, Jia-Bao;Chen, An-Zhen;Wang, Tao
    • Steel and Composite Structures
    • /
    • 제33권6호
    • /
    • pp.877-889
    • /
    • 2019
  • The developments of double skin composite (DSC) walls with novel enhanced C-channel connectors (DSCW-EC) were reported. Followed axial compression tests on prototype walls were carried to evaluate structural performances of this novel DSC composite structures. The testing program consists of five specimens and focused on the layout of the novel enhanced C-channel (EC) connectors, which include the web direction of C-channels, steel-faceplate thickness, vertical and horizontal spacing of C-channels. Crushing in concrete core and buckling of steel faceplate were two main observed failed modes from the compression tests. However, elastic or plastic buckling of the steel faceplate varies with designed parameters in different specimens. The influences of those investigated parameters on axial compressive behaviors of DSCW-ECs were analyzed and discussed. Recommendations on the layout of novel EC connectors were then given based on these test results and discussions. This paper also developed analytical models for predictions on ultimate compressive resistance of DSCW-ECs. Validation against the reported test results show that the developed theoretical models predict well the ultimate compressive resistance of DSCW-ECs.

Reliability based partial safety factor of concrete containing nano silica and silica fume

  • Nanda, Anil Kumar;Bansal, Prem Pal;Kumar, Maneek
    • Computers and Concrete
    • /
    • 제26권5호
    • /
    • pp.385-395
    • /
    • 2020
  • The influence of combination of nano silica and silica fume, as partial cement replacement materials, on the properties of concrete has been studied through the measurement of compressive strength. The compressive strength of concrete in terms of mean, standard deviation and with-in-test coefficient of variation related to the variation in the nominated parameters have also been developed. The compressive strength data developed experimentally has been analyzed using normal-probability distribution and partial safety factors of composite concretes have been evaluated by using first order second moment approach with Hasofer Lind's method. The use of Nano silica and silica fume in concrete decreases the partial safety factor of concrete i.e., increase the reliability of concrete. The experimental results show that the properties of concrete having nano silica and silica fume in combination were better than that of a plain concrete. The SEM test results showing the level of Ca(OH)2 in plain concrete and consumption level Ca(OH)2 of concrete containing nano silica & silica fume have also been presented.

Experimental investigation of self-healing concrete after crack using nano-capsules including polymeric shell and nanoparticles core

  • Taheri, Mojtaba Naseri;Sabet, Seyyed Ali;Kolahchi, Reza
    • Smart Structures and Systems
    • /
    • 제25권3호
    • /
    • pp.337-343
    • /
    • 2020
  • In this paper, we focused on the self-healing concrete using new nano-capsules. Three types of nano-capsules with respect to availability, high strength and temperature tolerance are used; type 1 is URF and polyethylene (PE) as shell and nano titanium oxide (TiO2) as core, type 2 is URF and PE as shell and nano silica oxide (SiO2) as core, type 3 is PE as shell and nano silica oxide (SiO2) as core. The concrete samples mixed by nano-capsules with three percents of 0.5, 1 and 1.5. Based on experimental tests and the compressive strength of samples, the URF-PE-SiO2 is selected for additional tests of compressive strength before and after recovery, ultrasonic test, ion chlorine and water penetration depths. After careful investigation, it is concluded that the optimum value of URF-PE-SiO2 nano-capsules is 0.5% since leads to higher compressive strength, ultrasonic test, ion chlorine and water penetration depths.

제지애쉬가 적용된 CLSM의 일축압축강도 특성에 관한 연구 (A Study on Unconfined Compressive Strength of CLSM with Paper Sludge Ash)

  • 박정준;이인환;신은철;홍기권
    • 한국지반신소재학회논문집
    • /
    • 제18권4호
    • /
    • pp.253-262
    • /
    • 2019
  • 본 연구에서는 하수관 손상을 예방할 수 있는 CLSM을 개발하기 위하여, 산업폐기물인 제지애쉬를 이용한 CLSM의 일축압축강도 특성을 평가하였다. 이를 위해, 각각의 CLSM 배합조건에 따른 유동성시험 및 일축압축강도시험을 수행하였다. 먼저, 유동성시험 결과, 배합조건에 따라 유동성 기준을 만족하는 함수비의 범위는 24%~32%인 것으로 나타났다. 일축압축강도시험 결과, 강도는 재령일 1일에서 7일 사이에 높은 강도증가율을 보였으며, 이때 강도의 크기는 재령일 28일을 기준으로 발현된 전체 강도의 약 50% 이상인 것으로 확인되었다. 그리고 CLSM의 강도 증가는 플라이애쉬의 영향을 크게 받는 것으로 나타났지만, 개발하고자 하는 CLSM의 기준강도를 고려하면 제지애쉬의 배합이 요구되는 것으로 분석되었다. 또한 높은 시멘트 비율을 적용한 경우의 강도가 낮은 경우에 비하여 크게 발현되었지만, 기준강도를 고려하면 시멘트의 비율을 5%로 적용하는 것이 합리적인 배합조건이라고 판단되었다.

Effect of solution temperature on the mechanical properties of dual-cure resin cements

  • Kang, En-Sook;Jeon, Yeong-Chan;Jeong, Chang-Mo;Huh, Jung-Bo;Yun, Mi-Jung;Kwon, Yong-Hoon
    • The Journal of Advanced Prosthodontics
    • /
    • 제5권2호
    • /
    • pp.133-139
    • /
    • 2013
  • PURPOSE. This study was to evaluate the effect of the solution temperature on the mechanical properties of dualcure resin cements. MATERIALS AND METHODS. For the study, five dual-cure resin cements were chosen and light cured. To evaluate the effect of temperature on the specimens, the light-cured specimens were immersed in deionized water at three different temperatures (4, 37 and $60^{\circ}C$) for 7 days. The control specimens were aged in a $37^{\circ}C$ dry and dark chamber for 24 hours. The mechanical properties of the light-cured specimens were evaluated using the Vickers hardness test, three-point bending test, and compression test, respectively. Both flexural and compressive properties were evaluated using a universal testing machine. The data were analyzed using a two way ANOVA with Tukey test to perform multiple comparisons (${\alpha}$=0.05). RESULTS. After immersion, the specimens showed significantly different microhardness, flexural, and compressive properties compared to the control case regardless of solution temperatures. Depending on the resin brand, the microhardness difference between the top and bottom surfaces ranged approximately 3.3-12.2%. Among the specimens, BisCem and Calibra showed the highest and lowest decrease of flexural strength, respectively. Also, Calibra and Multilink Automix showed the highest and lowest decrease of compressive strength, respectively compared to the control case. CONCLUSION. The examined dual-cure resin cements had compatible flexural and compressive properties with most methacrylate-based composite resins and the underlying dentin regardless of solution temperature. However, the effect of the solution temperature on the mechanical properties was not consistent and depended more on the resin brand.

Estimation of tensile strength and moduli of a tension-compression bi-modular rock

  • Wei, Jiong;Zhou, Jingren;Song, Jae-Joon;Chen, Yulong;Kulatilake, Pinnaduwa H.S.W.
    • Geomechanics and Engineering
    • /
    • 제24권4호
    • /
    • pp.349-358
    • /
    • 2021
  • The Brazilian test has been widely used to determine the indirect tensile strength of rock, concrete and other brittle materials. The basic assumption for the calculation formula of Brazilian tensile strength is that the elastic moduli of rock are the same both in tension and compression. However, the fact is that the elastic moduli in tension and compression of most rocks are different. Thus, the formula of Brazilian tensile strength under the assumption of isotropy is unreasonable. In the present study, we conducted Brazilian tests on flat disk-shaped rock specimens and attached strain gauges at the center of the disc to measure the strains of rock. A tension-compression bi-modular model is proposed to interpret the data of the Brazilian test. The relations between the principal strains, principal stresses and the ratio of the compressive modulus to tensile modulus at the disc center are established. Thus, the tensile and compressive moduli as well as the correct tensile strength can be estimated simultaneously by the new formulas. It is found that the tensile and compressive moduli obtained using these formulas were in well agreement with the values obtained from the direct tension and compression tests. The formulas deduced from the Brazilian test based on the assumption of isotropy overestimated the tensile strength and tensile modulus and underestimated the compressive modulus. This work provides a new methodology to estimate tensile strength and moduli of rock simultaneously considering tension-compression bi-modularity.

마천석재의 물리적 특성에 관한 연구 (A study of Physical Characteristic on Machun Building Stone)

  • 양해승;김종인;최한규
    • 화약ㆍ발파
    • /
    • 제22권2호
    • /
    • pp.45-54
    • /
    • 2004
  • 본 연구논문에서는 우리나라 주요 석재인 마천석 원석을 경남 함양군 마천면 기흥리에 위치한 마천석재, 덕우석재을 방문하여 원석과 판석을 색상, 조직, 구성광물, 입도의 차이에 따라 마천석 원석 17개를 채취하였다. 본 현장에서 채취한 시료에 대한 비중. 공극율. 흡수율. Point Load Test, 삼축압축시험, Brazilian Test, 암석학적 시험 및 분석, 화학적 시험 및 분석을 통해 마천석 원석의 물리적 특성을 규명하여 석재의 용도에 따른 타당성을 파악하는데 목적이 있다.

순환굵은골재가 콘크리트의 압축강도 및 역학적 특성에 미치는 영향 (Effect of Recycled Coarse Aggregate on Compressive Strength and Mechanical Properties of Concrete)

  • 양인환;정준영
    • 콘크리트학회논문집
    • /
    • 제28권1호
    • /
    • pp.105-113
    • /
    • 2016
  • 순환골재를 사용한 콘크리트의 재료 및 역학 특성에 관한 대부분의 연구는 압축강도 40 MPa 이하의 콘크리트에 대하여 수행되었으며, 40 MPa 이상의 순환골재 콘크리트에 대한 역학적 특성에 대한 연구결과는 미비하다. 따라서, 이 연구에서는 순환골재 사용의 확대를 위해 40 MPa 이상의 순환골재 콘크리트의 압축강도 및 역학 특성을 파악하였다. 순환골재 콘크리트의 역학 특성을 파악하기 위하여 콘크리트 압축강도 및 순환굵은골재 치환율을 실험변수로 고려하였다. 실험변수로서 콘크리트의 압축강도는 45 및 60 MPa이고, 순환골재 치환율은 30, 50, 70 및 100%이다. 실험변수에 따른 순환골재 콘크리트의 압축강도, 탄성계수, 인장강도 및 파괴계수 특성을 분석하였다. 실험결과는 고강도 콘크리트일수록 순환골재 치환율에 따른 압축강도 감소량이 작은 것을 나타낸다. 탄성계수 실험결과와 기존설계코드에 의한 탄성계수 예측결과를 비교하였으며, 설계코드에 의한 예측결과는 실험결과를 과다평가하고 있다. 반면에 설계코드에 의한 파괴계수 예측결과와 실험결과는 잘 일치한다.

Experimental study on the compressive stress dependency of full scale low hardness lead rubber bearing

  • Lee, Hong-Pyo;Cho, Myung-Sug;Kim, Sunyong;Park, Jin-Young;Jang, Kwang-Seok
    • Structural Engineering and Mechanics
    • /
    • 제50권1호
    • /
    • pp.89-103
    • /
    • 2014
  • According to experimental studies made so far, design formula of shear characteristics suggested by ISO 22762 and JEAG 4614, representative design code for Lead Rubber Bearing(LRB) shows dependence caused by changes in compressive stress. Especially, in the case of atypical special structure, such as a nuclear power structure, placement of seismic isolation bearing is more limited compared to that of existing structures and design compressive stress is various in sizes. As a result, there is a difference between design factor and real behavior with regards to shear characteristics of base isolation device, depending on compressive stress. In this study, a full-scale low hardness device of LRB, representative base isolation device was manufactured, analyzed, and then evaluated through an experiment on shear characteristics related to various compressive stresses. With design compressive stress of the full-scale LRB (13MPa) being a basis, changes in shear characteristics were analyzed for compressive stress of 5 MPa, 10 MPa, 13 MPa, 15 MPa, and 20 MPa based on characteristics test specified by ISO 22762:2010 and based on the test result, a regression analysis was made to offer an empirical formula. With application of proposed design formula which reflected the existing design formula and empirical formula, trend of horizontal characteristics was analyzed.