• Title/Summary/Keyword: Compressive stength

Search Result 17, Processing Time 0.02 seconds

An Experimental Study on the Physical Properties of Porous Cement Concrete Using Polymer as an Admixture (폴리머를 혼화재로 혼입한 투수콘크리트의 물리적 특성에 관한 실험적 연구)

  • 채창우;민병렬;심종우
    • Journal of the Korea Concrete Institute
    • /
    • v.12 no.5
    • /
    • pp.131-139
    • /
    • 2000
  • Porous Concrete usually contains large amount of voids(about 10∼20%) after compaction so that it has relatively high permeability. It has been introduced in domestic since early 1980's but it has problems such as lack of optimized mixture, low strength and durability, and other defects, etc. The purpose of this study is to manufacture high-performance porous concrete using polymer to enhance the mechanical properties. The results of this study are as follows; the compressive strength range 12 92∼207kgf/㎠, the tensile strength range is 14∼28kgf/㎠, the bending stength range is 42∼73kgf/㎠, and the coefficient permeability range is 5.77×10-2∼6.79×10-1cm/sec. To develope high-performance porous concrete. further studies are needed on optimum mixture of fineness modulus and admixture.

Strength Improvement of Linerboard by impregnation with PVAm (PVAm 함침에 의한 라이너지 강도 향상)

  • Kim, Hyuk-Jung;Won, Jong-Myoung;Cho, Byoung-Uk
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.44 no.1
    • /
    • pp.58-64
    • /
    • 2012
  • As a first step to apply PVAm (polyvinylamine) on packaging paper by surface treatment, three types of linerboards were impregnated with PVAm solution. The effect of PVAm pick-up on strength properties of linerboard was investigated. The pick-up of PVAm was controlled by varying concentration of PVAm solution. It was found that dry tensile strength, tensile energy absorption, burst strength and compressive strength of linerboard were increased by applying PVAm. In addition, wet tensile strength was significantly improved with increasing PVAm pick-up. However, folding endurance was found to be decreased with increasing PVAm pick-up.

An Experimental Study on Stength of Slender Square Tube Columns Filled with High Strength Concrete (고강도콘크리트충전 각형강관장주의 내력에 관한 실험적 연구)

  • Seo, Seong Yeon;Chung, Jin An
    • Journal of Korean Society of Steel Construction
    • /
    • v.14 no.4
    • /
    • pp.471-479
    • /
    • 2002
  • In this paper, 18 square CFT columns filled with high-strength concrete were tested under concentric or eccentric axial loading. Two parameters of the experimental program included the buckling length-section depth ratio ($L_K$/D) and the eccentricity of the appled compressive load (e). In additon, mechanical properties such as the compressive concrete strength and compressive and tensile steel strength were measured and incorporated into the material models for the stress-strain relationships of concrete and steel. This model was used in an elasto-plastic analysis in order to predict the behavior of the slender CFT columns. Observtions of the failure mode during the tests under axial loadig were also presented. The strengths obtained from the analysis. Recommendations for Design, and Constructions of CFT structures were presented, as verified by the experimental results.

THE QUALITY PROPERTIES FOR FLY ASH OF COMBINED HEAT POWER PLAINT AND MECHANANICAL PROPERTIES IN CONCRETE (열병합발전소 플라이애쉬 품질 및 콘크리트의 역학적 특성)

  • Lee, Sang-Soo;Back, Myung-Jong;Won, Cheol;Ahn, Jae-Hyen;Park, Chil-Lim
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1995.10a
    • /
    • pp.69-74
    • /
    • 1995
  • The primary purpose of this study is to investigate reusal techniques of fly ash of combined heat power plant in the construction field, which may contribute to the saving of construction materials and conservating environment. Firstly chemical and physical characteristics of fly ash is analysed. And then, the usability of the concrete is tested by investigating the flowablility and stength development through parameters of various replacement ratios with respect to different mixing conditions. Finally, the durability and mechanical properties(elastic modulus) of the concrete is tested. As the result of the study, the following conclusions are derived : (1) the quantity of the CaO in the fly ash is relatively high based on the chemical analysis, (2)the compressive strength ratio of the mortar is satisfied with the specification, but the unit water ratio increased, (3)high strength concrete of more than 400kg/$\textrm{cm}^2$ can be developed in the ranges of FA 30%, W/B 40%, (5)the slump loss with the elapsed time due to the delivery is decreased as the replacement ratio of the fly ash is increased, (6)the modulus of the elasticity is matched withn the specification of the Architectural Institute of Korea.

  • PDF

Axial compressive strength of short steel and composite columns fabricated with high stength steel plate

  • Uy, B.
    • Steel and Composite Structures
    • /
    • v.1 no.2
    • /
    • pp.171-185
    • /
    • 2001
  • The design of tall buildings has recently provided many challenges to structural engineers. One such challenge is to minimise the cross-sectional dimensions of columns to ensure greater floor space in a building is attainable. This has both an economic and aesthetics benefit in buildings, which require structural engineering solutions. The use of high strength steel in tall buildings has the ability to achieve these benefits as the material provides a higher strength to cross-section ratio. However as the strength of the steel is increased the buckling characteristics become more dominant with slenderness limits for both local and global buckling becoming more significant. To arrest the problems associated with buckling of high strength steel, concrete filling and encasement can be utilised as it has the affect of changing the buckling mode, which increases the strength and stiffness of the member. This paper describes an experimental program undertaken for both encased and concrete filled composite columns, which were designed to be stocky in nature and thus fail by strength alone. The columns were designed to consider the strength in axial compression and were fabricated from high strength steel plate. In addition to the encased and concrete filled columns, unencased columns and hollow columns were also fabricated and tested to act as calibration specimens. A model for the axial strength was suggested and this is shown to compare well with the test results. Finally aspects of further research are addressed in this paper which include considering the effects of slender columns which may fail by global instabilities.

Experimental Study of Reinforced High-Strength Concrete Beams without Stirrups Considering Shear Behaviour (전단보강근이 없는 고강도 콘크리트 깊은 보의 전단특성 실험연구)

  • Yang, Seong-Hwan;Lee, Dong-Jun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.14 no.4
    • /
    • pp.336-342
    • /
    • 2014
  • Shear strengths of reinforced high strength concrete beams without web reinforcement are studied with experimental analysis of 10 specimen with 2.4 shear span-to-depth ratio (a/d) beams for 4 stages of concrete compressive stength over 60MPa comparing ultimate loads and shear stresses of ACI363R and KCI code equations. Expecially, concrete compressive strengths used in shear design were essentially limited to 10,000 psi (69MPa) by ACI363R and KCI Code. The modified Code equation's shear stresses of the specimen without the limit are compared with test results. The comparison between the modified exist Code equations results and test results are expected to show an available scope to apply in construction field and to give considerations of design and contraction.

A Study on the Effect of Curing Temperature on the Unconfined Compressive Strength of Soil Cement Mixtures. (양생온도가 Soil Cement의 압축강도에 미치는 영향에 관한 연구)

  • 김재영
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.17 no.4
    • /
    • pp.3931-3942
    • /
    • 1975
  • This study was conducted to investigate the strength of soil cement for varied curing temperatures (0,10,20,30,40,50,60$^{\circ}C$) and cement content (3,6,9,12%) in four cement-stabilized soils (KY: sand, MH: sand, SS: sandy loam, JJ:loam). The experimental results obtained from unconfined compressive strength tests were as follows: 1. According to increase of curing temperature as 30,40,50, and 60$^{\circ}C$, the unconfiened compressive strength of soil cement increased, the rate of increase in the early curing period was large, and around 120 hours was suifficient curing time to complete hardening. 2. The strength at 10$^{\circ}C$ decreased to the rate of 30 to 40 percent than that of 20$^{\circ}C$ while the strength at 0$^{\circ}C$ was very small, strength of soil cement increased in cold weather unless that the temperature was below 0$^{\circ}C$ 3. The average maximum temperature, about 30$^{\circ}C$ during July and August in Korea may be recommended for a optimum construction period to increase the strength of soil cement. 4. Accelerated curing time that strength was equivalent to 28-Day norma1 curing decreased in accordance with the increase of curing temperature, and also accelerated curing decreased the effect of cement content. Accelerated curing that strength was equivalent to 28-day normal curing for soil cement of cement content 9% and temperature 60$^{\circ}C$ was 45 hours; KY, 50 hours: MH, 40 hours; SS, 34 hours; JJ. 5. According to the increase of the percent passing of No. 200 sieve, accelerated curing times became shorter to become the required stength. 6. Relation between accelerated curing times and normal curing days was showeda linear of which slope decreased in accordance with the increase of curing temperature, it may be expressed as follows: (1). 30$^{\circ}C$ t=3.6d+6(r=0.97) (2). 40$^{\circ}C$ t=3.2d-5.1(r=0.95) (3). 50$^{\circ}C$ t=2.1d-4.0(r=0.93) (4). 60$^{\circ}C$ t=1.4d+4.0(r=0.90) in which t=accelerate curing time. d=normal curing day. 7. Accelerated curing time that the strength was equivalent to 35kg/$\textrm{cm}^2$ which was the strength of cement brick was 96 hours at temperature 30$^{\circ}C$ to SS 9%, and 120 hours at temperature 50$^{\circ}C$ to JJ 9%, Consequently, a economic soil cement brick may be made in future.

  • PDF