• Title/Summary/Keyword: Compression Factor

Search Result 479, Processing Time 0.028 seconds

FORMATION OF PROTO-GLOBULAR CLUSTER CLOUDS BY THERMAL INSTABILITY

  • KANG HYESUNG;LAKE GEORGE;RYU DONGSU
    • 천문학회지
    • /
    • 제33권2호
    • /
    • pp.111-121
    • /
    • 2000
  • Many models of globular cluster formation assume the presence of cold dense clouds in early universe. Here we re-examine the Fall & Rees (1985) model for formation of proto-globular cluster clouds (PGCCs) via thermal instabilities in a protogalactic halo. We first argue, based on the previous study of two-dimensional numerical simulations of thermally unstable clouds in a stratified halo of galaxy clusters by Real et al. (1991), that under the protogalactic environments only nonlinear (${\delta}{\ge}1$) density inhomogeneities can condense into PGCCs without being disrupted by the buoyancy-driven dynamical instabilities. We then carry out numerical simulations of the collapse of overdense douds in one-dimensional spherical geometry, including self-gravity and radiative cooling down to T = $10^4$ K. Since imprinting of Jeans mass at $10^4$ K is essential to this model, here we focus on the cases where external UV background radiation prevents the formation of $H_2$ molecules and so prevent the cloud from cooling below $10^4$ K. The quantitative results from these simulations can be summarized as follows: 1) Perturbations smaller than $M_{min}\~(10^{5.6}\;M{\bigodot})(nh/0.05cm^{-3})^{-2}$ cool isobarically, where nh is the unperturbed halo density, while perturbations larger than $M_{min}\~(10^8\;M{\bigodot})(nh/0.05cm^{-3})^{-2}$ cool isochorically and thermal instabilities do not operate. On the other hand, intermediate size perturbations ($M_{min} < M_{pgcc} < M_{max}$) are compressed supersonically, accompanied by strong accretion shocks. 2) For supersonically collapsing clouds, the density compression factor after they cool to $T_c = 10^4$ K range $10^{2.5} - 10^6$, while the isobaric compression factor is only $10^{2.5}$. 3) Isobarically collapsed clouds ($M < M_{min}$) are too small to be gravitationally bound. For supersonically collapsing clouds, however, the Jeans mass can be reduced to as small as $10^{5.5}\;M_{\bigodot}(nh/0.05cm^{-3})^{-1/2}$ at the maximum compression owing to the increased density compression. 4) The density profile of simulated PGCCs can be approximated by a constant core with a halo of $p{\infty} r^{-2}$ rather than a singular isothermal sphere.

  • PDF

Are "Unstable" Burst Fractures Really Unstable?

  • Woo, Jun Hyuk;Lee, Hyun Woo;Choi, Hong June;Kwon, Young Min
    • Journal of Korean Neurosurgical Society
    • /
    • 제64권6호
    • /
    • pp.944-949
    • /
    • 2021
  • Objective : The stability is an important factor to decide the treatment plan in thoracolumbar burst fracture patients. Patients with an unstable burst fracture generally need operative management. Decrease in vertebral body height, local kyphosis, involvement of posterior column, and/or canal compromise are considered important factors to determine the treatment plan. On the other hand, in thoracolumbar injury classification system (TLICS), surgery is recommended in patients with TLICS of more than 5 points. The purpose of this study was to apply the TLICS score in patients with thoracolumbar burst fractures and to distinguish the differences of treatment plan on burst fracture. Methods : All patients, diagnosed as a thoracolumbar burst fracture between January 2006 and February 2019 were included in this study. Unstable thoracolumbar burst fracture was defined as burst fracture with neurologic deficit, three-column injury, kyphosis over 30 degrees, decrease of anterior body height over 40 percent and canal comprise more than 50%. TLICS score was measured with morphology, neurological involvement and posterior ligamentous complex integrity. The existence of instability was compared with TLICS score. Results : Total 233 patients (131 men, 102 women) were included in this study. In Denis classification, 51 patients (21.9%) diagnosed as stable burst fracture while 182 patients (78.1%) had unstable burst fracture. According to TLICS, 72 patients (30.9%) scored less than 4, while 161 patients (69.1%) scored 4 or more. All the patients with stable burst fracture scored 2 in TLICS. Twenty-one patients (9.0) scored 2 in TLICS but diagnosed as unstable burst fracture. Thirteen patients had over 40% of vertebra body compression, four patients had more than 50% of canal compromise, three patients had both body compression over 40% and kyphosis over 30 degrees, one patients had both body compression and canal compromise. Fifteen patients presented kyphosis over 30 degrees, and three (20%) of them scored 2 in TLICS. Seventy-three patients presented vertebral body compression over 40% and 17 (23.3%) of them scored 2 in TLICS. Fifty-three patients presented spinal canal compromise more than 50%, and five (9.4%) of them scored 2 in TLICS. Conclusion : Although the instability of thoracolumbar burst fracture was regarded as a critical factor for operability, therapeutic strategies by TLICS do not exactly match with the concept of instability. According to the concept of TLICS, it should be reconsidered whether the unstable burst fracture truly unstable to do operation.

관심영역 구분을 통한 감시영상시스템의 효율적 압축 (Effective Compression of the Surveillance Video with Region of Interest)

  • 고미애;김영모;고광식
    • 정보처리학회논문지B
    • /
    • 제10B권1호
    • /
    • pp.95-102
    • /
    • 2003
  • 현재의 영상 감시 및 기록 시스템은 감시 영역 내 감시대상의 출현여부와 상관없이 감시카메라에 담기는 전체영상을 일관적으로 저장, 기록함으로써 데이터량이 방대한데 비해 그 가운데 정사 필요한 정보에 대한 량은 적다 하겠다. 배경영역 범위가 고정되어 있는 감시영상시스템에서 배경영상이 실제적인 감시대상에 대한 정보가 담긴 관심영역과 동일한 등급의 정보로 취급되어 기록이 됨으로써 데이터량에 비해 현장 감시효과를 제대로 보지 못하고 있는 것이다. 따라서, 감시 영역 내에서 관심영역에 대한 효율적인 정보의 기록과 보다 정확히 감시대상에 대한 영상을 획득하는 것이 감시영상시스템에서의 목표라 하겠다. 본 논문에서는 위의 문제점들을 해결하기 위해 감시영상으로부터 관심영역을 구분해내고 그 중요도에 따른 압축효율을 달리 함으로써 이를 구현할 수 있도록 하였다. 중요도를 결정하는 특성으로 관심영역을 무엇으로 할 것인가에 따라 감시영상을 영역별로 몇 단계의 블록으로 나누고 각 블록에 대해 해상도를 달리하여 중요도가 높은 관심영역 일수록 고해상의 영상을 획득하고 중요도가 낮을수록 저해상의 영상으로 처리하고 압축품질 또한 중요도가 놀은 관심영역일수록 압축품질은 높이고 중요도가 낮은 관심영 역일수록 압축률을 높임으로써 감시영상 정보의 감을 최적화 함은 물론 효율적인 감시 및 기록이 가능하도록 하였다.

교량용 탄성받침의 설계압축응력에 대한 고찰 (The Design Criteria of elastomeric Bearing for Highway Bridges)

  • 전규식;이병진;조해진;정명호
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1998년도 가을 학술발표논문집(II)
    • /
    • pp.481-488
    • /
    • 1998
  • Elastomeric bearing is used as one of the most useful way for isolation structures, because the horizontal stiffness is much lower than the vertical stiffness. In the design criteria of Elastomeric bearing, the stability of the bearings is evaluated by shear strain due to compression, lateral displacement, and rotation. The question how soft rubber can sustain heavy structure is now able to be solved by Ultimate capacity test of Laminated Elastomeric Bearings, which results 1,200kg/$\textrm{cm}^2$ of the max. compressive stress and this shows what a sufficient safety factor Elastomeric bearing has !

  • PDF

보강 개구부가 있는 복합재료 원통셸의 축방향 하중에 따른 응력해석 (Stress Analysis on Composite Cylindrical Shells with a Reinforced Cutout Subjected to Axial Load)

  • 이영신;류충현;김영완
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 1999년도 추계학술발표대회 논문집
    • /
    • pp.211-214
    • /
    • 1999
  • The stress distribution around the cutout of composite cylindrical shells with a circular or elliptical reinforced cutout subjected to axial compression or tension is studied by asymptotic method. Analytical solutions used a Donnell type orthotropic shell theory are presented by the defined stress concentration factor and are compared to experimental results. The experiment used the universal testing machine (UTM), strain gage and fixtures designed/manufactured for axial tension test of a cylindrical shell is carried and the composite material used in the experiment is plain weave glass fiber reinforced plastic (GFRP).

  • PDF

MPEG-2 AAC 심리음향 모델을 이용한 오디오 워터마킹 기법 (The Audio Watermarking method Using the MPEG-2 AAC Psychoacoustic Model)

  • 성종수;강상구;신재호
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 1999년도 하계종합학술대회 논문집
    • /
    • pp.716-719
    • /
    • 1999
  • In this Paper, we Present a method for embedding digital watermarks into digital audio signals. The watermarking must be imperceptible and should be robust to attacks, such as filtering and compression etc. In our method, we adaptively embedded the watermarks changing the scale factor using the spread spectrum and MPEG-2 AAC psychoacoustic model.

  • PDF

MPEG-2 AAC의 MDCT/IMDCT를 위한 최적 알고리즘 개발 (A Development on the Optimization Algorithm for MDCT/IMDCT of MPEG-2 AAC)

  • 김병규;이강현
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 1999년도 하계종합학술대회 논문집
    • /
    • pp.538-541
    • /
    • 1999
  • MPEG-2 AAC(Advanced Audio Coding) is the most advanced coding scheme available for high quality audio coding. This MPEG-2 AAC audio Standard allows for ITU-R ‘indistinguishable’ quality according to at data rates of 320 kb/s for five full-bandwidth channel audio signals. The compression ratio is around a factor of 1.4 better compared to MPEG Layer 3, you get the same quality at 70% of the bitrate. This paper suggest optimization method for MDCT/IMDCT (Modified Discrete Cosine Transform/Inverse Modified Discrete Cosine Transform) in Encoder and Decoder for AAC.

  • PDF

LDV측정을 통한 엔진내 텀블감쇄 메카니즘 해석 (Analysis of Tumble Decay Mechanism through LDV Measurement in an Engine)

  • 강건용;이진욱;백제현
    • 대한기계학회논문집
    • /
    • 제18권10호
    • /
    • pp.2773-2778
    • /
    • 1994
  • Tumbling motion is very effective for turbulence enhancement during compression process in the cylinder of 4-valve engines. In this paper the tumble decay mechanism for different intake port configuration were measured using laser Doppler velocimetry. Analysis of the tumble decay mechanism was achieved by means of two non-dimensional parameters, defined as tumble eccentricity and shape factor in tumble velocity profile, in addition to the tumble moment.

골프 드라이브 스윙 시 압축 밴드를 적용한 기능성 의류가 신체의 운동역학적 변인에 미치는 영향 (The Effect of Wear ing Spandex Wear with Compression Band on Biomechanical Parameters during a Golf Drive Swing)

  • 채원식;강년주
    • 한국운동역학회지
    • /
    • 제21권3호
    • /
    • pp.345-352
    • /
    • 2011
  • The purpose of this study was to determine how spandex wear with compressive band affects biomechanical parameters during a golf swing. Nine male golf players, each with at least 6 years golf experienc(handy 4.5${\pm}$5.4), were recruited as the participants. Eight pairs of surface electrodes were attached to the left and right side of the body to monitor the pectoralis major(PM), external abdominal oblique(AO), erector spinae(ES), and vastus lateralis(VL). This study showed that the angular velocity of the club in EG were increased during the down swing phase but X-Factor and X-factor Stretch were reduced. Average and maximum nEMG (normalized EMG) values of the left AO(external abdominal oblique) were less in EG(experimental group) compared with CG(control group) during the back swing, whereas those of left PM(pectoralis major) in EG were greater than CG. It is more likely that EG performed effectively golf swing without excess muscle activity. Thus, the spandex wear with compressive band played an important role in improving swing performance with injury prevention. This has led to suggestions of the need for further kinetic and kinematic analyses to evaluate its function.

반복하중을 받는 콘크리트충전 강합성 기둥의 연성에 관한 연구 (A Study on the Ductility of Concrete-Filled Composite Columns under Cyclic Loading)

  • 송준엽;권영봉;김성곤
    • 한국지진공학회논문집
    • /
    • 제5권6호
    • /
    • pp.11-19
    • /
    • 2001
  • 일정한 축하중과 반복적인 횡하중을 받는 콘크리트충전 강합성 기둥의 내진성능에 관한 실험적인 연구가 수행되었다. 강합성 기둥은 충전콘크리트가 강판의 국부좌굴로 인한 내측방향의 변형을 억제하고, 강판의 콘크리트 측압에 대한 구속효과와 같은 상호작용에 의해서 콘크리트와 강재의 단순누가강도 이상의 강도증진효과를 가지며, 강재 및 콘크리트기둥에 비해 우수한 연성 및 에너지 흡수능력을 나타내었다. 단면분할법을 이용하여 콘크리트충전 강합성 기둥의 비선형 모멘트-곡률 관계를 예측해 보았으며, 이는 실험결과와 비교적 잘 일치하는 것으로 나타났다. 또한, 구조물의 내진설계의 중요한 요소인 강합성 기둥의 연성 및 응답수정계수를 평가해 보았다. 실험결과 강합성 기둥은 효과적인 내진구조 부재로 판단되었다.

  • PDF