• 제목/요약/키워드: Composite indicator

검색결과 66건 처리시간 0.031초

부하의 전압특성을 고려한 정량적 전압안정성 지표에 관한 연구 (A Study on the Quantatitive Voltage Stability Index Considering Load Voltage Characteristics)

  • 정준모;이봉용;김정훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 추계학술대회 논문집 학회본부
    • /
    • pp.3-5
    • /
    • 1994
  • It is shown that the power flow considering the voltage characteristic of the composite load has some difference comparing with conventional load flow in this paper. When the load flow is used in a study of the static voltage stability, it is necessary to consider the voltage characteristic of load, since the composite load of a typical power system bas constant power, constant current, and constant impedance characteristic. The load is modeled to a polynomial form in here, and used in solving the load flow problem. In this way, the effect which the voltage characteristic of the load has on several voltage collapse proximity indicator based on sensitivities is compared with the conventional load flow, or with another load model having a different voltage characteristic. In this paper, the voltage collapse proximity indicator using the sensitivity of real power for transmission loss is also proposed, and compared with other indicators.

  • PDF

레이더 정량강우와 연계한 홍수유출 및 범람해석 시스템 확립 I. 품질검사와 합성 CAPPI 산출 (Development of a Flood Runoff and Inundation Analysis System Associated With 2-D Rainfall Data Generated Using Radar I. Quality Control and CAPPI Composite Calculation)

  • 최규현;한건연;김경익;이창희
    • 한국수자원학회논문집
    • /
    • 제39권4호
    • /
    • pp.321-334
    • /
    • 2006
  • 본 연구에서는 3차원 공간상에서 구면 좌표계값을 가지는 레이더 반사도 자료를 직교 좌표계로 변환하기 위한 CAPPI(Constant Altitude Plan Position Indicator) 산출 프로그램을 개발한다. 오염되지 않은 CAPPI 자료의 산출을 위해서 레이더 반사도 자료에 대한 품질검사 과정이 선행되었다. 개발된 모형은 3차원 공간상에서의 연속성을 유지하기 위해서 가장 근접하고 가장 적은 자료수를 운영함으로서 최적의 반사도 자료를 보간하였다. 개발된 모형은 자료의 이용목적에 따라서 다양한 해상도 및 고도에 대한 자료가 필요할 수 있다는 생각 하에 임의의 해상도 및 고도등에 대한 자료를 효율적으로 계산해 낼 수 있다.

타격음을 이용한 복합재료 구조물의 비파괴 검사법 개발 (Development of Non-destructive Evaluation Method for Composite Structures using Tapping Sound)

  • 황준석;김승조
    • Composites Research
    • /
    • 제17권1호
    • /
    • pp.1-9
    • /
    • 2004
  • 본 연구에서는 타격음을 이용한 비파괴 검사법을 제안하였다. 제안된 방법(tapping sound analysis)은 건강한 구조물과 손상된 구조물의 타격음의 차이를 분석하여 구조물의 손상 유무를 판단하는 방법이다. 타격음의 직접적인 비교는 비효율적이므로 타격음으로부터 특성을 추출하기 위해 wavelet packet transform에 기반한 특성추출법을 제안하였다. 또한 추출된 특성 자료를 바탕으로 손상의 유무를 판단하는 지표로서 특성 지수를 정의하였다. 제안된 방법의 타당성을 밝히기 위해 실험적인 검증을 수행하였다. 복합재료를 이용하여 건강한 구조물과 손상된 구조물을 제작하고 타격음을 측정하였다. 제안된 손상 판단 기법을 이용한 결과로부터 특성 지수에 의한 손상 판단의 타당성을 밝혔다.

호흡율 측정에 의한 활성슬러지의 중금속 생물독성평가 (Biological Toxicity Evaluation of Heavy Metal using Oxygen Uptake Rate on Activated Sludge Process)

  • 안우정;백승규
    • 상하수도학회지
    • /
    • 제21권3호
    • /
    • pp.279-285
    • /
    • 2007
  • Toxicity evaluations using oxygen uptake rate (OUR) on activated sludge process were investigated. On toxicity evaluations of heavy metals, all toxicants in experiments decreased OUR with respect to the concentrations of the toxicants, while high toxicities with cyanide and mercury were observed respectively. On toxicity evaluations of composite heavy metals, composite toxicities had similar results as to the total sum of each toxicants that presents accurate toxicity evaluation using OUR. From these results, it is concluded that activated sludge is effective indicator for toxicity evaluation on wastewater of biological treatment plants.

Electro-Micromechanical 시험법을 이용한 Ni Nanowire Strands 및 Carbon Nanotube 강화 에폭시 복합재료의 비파괴 감지능 평가 (Nondestructive Sensing Evaluation of Ni Nanowire Strands and Carbon Nanotube/Epoxy Composites Using Electro-Micromechanical Techniques)

  • 정진규;김성주;박종만
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2005년도 춘계학술발표대회 논문집
    • /
    • pp.269-272
    • /
    • 2005
  • Nondestructive damage sensing and load transferring mechanism of Ni nanowire strands and multi-wall carbon nanotube (MWCNT)/epoxy composites were investigated using electro-micromechanical techniques. MWCNT composite was especially prepared for high volume contents, 50 vol % of reinforcement. Electro-micromechanical techniques were applied to measure apparent modulus and contact resistance of Ni nanocomposites with their alignment and different diameters, and adding contents. Applied cyclic load affected on apparent modulus and electrical properties on nanocomposites due to various inherent properties of each CNMs. Contact resistivity on humidity sensing was a good indicator for monitoring as for multifunctional applications. Further study on actuation as well as sensing will be investigated for the following work continuously.

  • PDF

Electro-Micromechanical 시험법을 이용한 Electrospun PVDF Fiber 및 CNT 강화 Epoxy 복합재료의 비파괴 감지능 평가 (Nondestructive Sensing Evaluation of Electrospun PVDF Fiber and Carbon Nanotube/Epoxy Composites Using Electro-Micromechanical Technique)

  • 정진규;김성주;박종만
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2005년도 추계학술발표대회 논문집
    • /
    • pp.153-156
    • /
    • 2005
  • Nondestructive sensing of electrospun PYDF web and multi-wall carbon nanotube (MWCNT)/epoxy composites were investigated using electro-micromechanical technique. Electrospinning is a technique used to produce micron to submicron diameter polymeric fibers. Electrospun PVDF web was also evaluated for the sensing properties by micromechanical test and by measurement electrical resistance. CNT composite was especially prepared for high volume contents, 50 vol% of reinforcement. Electrical contact resistivity on humidity sensing was a good indicator for monitoring as for multifunctional applications. Work of adhesion using contact angle measurement was studied to correlate acid-base surface energy between carbon fiber and CNF composites, and will study furher for interfacial adhesion force by micromechanical test.

  • PDF

Effect of stacking sequence of the bonded composite patch on repair performance

  • Beloufa, Hadja Imane;Ouinas, Djamel;Tarfaoui, Mostapha;Benderdouche, Noureddine
    • Structural Engineering and Mechanics
    • /
    • 제57권2호
    • /
    • pp.295-313
    • /
    • 2016
  • In this study, the three-dimensional finite element method is used to determine the stress intensity factor in Mode I and Mixed mode of a centered crack in an aluminum specimen repaired by a composite patch using contour integral. Various mesh densities were used to achieve convergence of the results. The effect of adhesive joint thickness, patch thickness, patch-specimen interface and layer sequence on the SIF was highlighted. The results obtained show that the patch-specimen contact surface is the best indicator of the deceleration of crack propagation, and hence of SIF reduction. Thus, the reduction in rigidity of the patch especially at adhesive layer-patch interface, allows the lowering of shear and normal stresses in the adhesive joint. The choice of the orientation of the adhesive layer-patch contact is important in the evolution of the shear and peel stresses. The patch will be more beneficial and effective while using the cross-layer on the contact surface.

Development of a Drought Detection Indicator using MODIS Thermal Infrared Data

  • Park, Sun-Yurp
    • 대한원격탐사학회지
    • /
    • 제20권1호
    • /
    • pp.1-11
    • /
    • 2004
  • Based on surface energy balance climatology, surface temperatures should respond to drying conditions well before plant response. To test this hypothesis, land surface temperatures (LST) derived from MODIS data were analyzed to determine how the data were correlated with climatic water balance variables and NDVI anomalies during a growing season in Western and Central Kansas. Daily MODIS data were integrated into weekly composites so that each composite data set included the maximum temperature recorded at each pixel during each composite period. Time-integrated, or cumulative values of the LST deviation standardized with mean air temperatures had significantly high correlation coefficients with SM, AE/PE, and MD/PE, ranging from 0.65 to 0.89. The Standardized Thermal Index (STI) is proposed in this study to accomplish the objective. The STI, based on surface temperatures standardized with observed mean air temperatures, had significant temporal relationships with the hydroclimatological factors. STI classes in all the composite periods also had a strong correlation with NDVI declines during a drought episode. Results showed that, based on LST, air temperature observations, and water budget analysis, NDVI declines below normal could be predicted as early as 8 weeks in advance in this study area.

Evaluating the Performance of the Emergency Medical Services Index

  • Eun, Sang Jun;Lee, Jin-Seok;Kim, Yoon;Jung, Koo Young;Park, Sue Kyung;Lee, Jin Yong
    • 보건행정학회지
    • /
    • 제23권2호
    • /
    • pp.176-187
    • /
    • 2013
  • Background: In 2006 Emergency Medical Services Index (EMSI), which summarizes the performance of regional emergency medical services system, was developed. This study assesses the performance of the EMSI to help determine whether EMSI can be used as evaluation tool. Methods: To build a composite score of the EMSI from predefined 24 indicators, 3 normalized values were calculated for each indicator, the normalized values of each indicator were weighted using 4 weighting methods, and the weighted values were aggregated into the final composite score using 2 aggregation schemes. The performance of EMSI was evaluated using 3 criteria: discrimination, construct validity, and sensitivity. Discrimination was the proportion of regions that did not include the overall median rank in the 5th to 95th percentiles rank interval, which was calculated from Monte Carlo simulation. Construct validity was a correlation among the alternative EMSIs. Sensitivity of EMSIs was evaluated by total shift of quartile membership and changes of 5th to 95th percentile intervals. Results: The total discrimination performance of the EMSI was 50.0%. Correlation coefficients between EMSIs using standardized values and those using rescaled values ranged from 0.621 to 0.997. Variation of the quartile membership of regions ranged from 0.0% to 75.0%. The total change in the 5th to 95th percentile intervals ranged from -19 to +17 places. Conclusion: The results suggested that the EMSI could be used as a tool for evaluating quality of regional EMS system and for identifying the areas for quality improvement.

Metamaterial CRLH Structure-based Balun for Common-Mode Current Indicator

  • Kahng, Sungtek;Lee, Jinil;Kim, Koon-Tae;Kim, Hyeong-Seok
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권1호
    • /
    • pp.301-306
    • /
    • 2014
  • We proposed a new PCB-type 'common-mode current($I_c$) and differential-mode current($I_d$) detector' working for fast detection of $I_c$ and $I_d$ from the differential-mode signaling, with miniaturization effect and possibility of cheaper fabrication. In order to realize this device, we suggest a branch-line-coupler balun having a composite right- and left-handed(CRLH) one-layer microstrip phase-shifting line as compact as roughly ${\lambda}_g/14$. The presented balun obviously is different from the conventional bent-&-folded delay lines or slits on the ground for coupling the lines on the top and bottom dielectrics. As we connect the suggested balun output ports of the differential-mode signal lines via the through-port named U and coupled-port named L, $I_c$ and $I_d$ will appear at port ${\Delta}$ and port ${\Sigma}$ of the present device, in order. The validity of the design scheme is verified by the circuit-and numerical electromagnetic analyses, and the dispersion curve proving the metamaterial characteristics of the geometry. Besides, the examples of the $I_c$ and $I_d$ indicator are observed as the even and odd modes in differential-mode signal feeding. Also, the proposed device is shown to be very compact, compared with the conventional structure.