• 제목/요약/키워드: Composite Resin

검색결과 1,959건 처리시간 0.032초

복합레진의 표면 광택에 대한 평가 (Evaluation of surface gloss of composite resins)

  • 변지은
    • 대한치과의료관리학회지
    • /
    • 제11권1호
    • /
    • pp.38-46
    • /
    • 2023
  • Composite resins, commonly used in clinical practice, have been developed to improve aesthetics to obtain smooth surfaces. Although the restored composite resin has a smooth surface, it gradually becomes rough over time. Therefore, this study measured glossiness to evaluate the surface of various composite resins and attempted to evaluate the maintenance of glossiness of composite resins by observing surfaces that change to roughness. Specimens were produced using resin used in clinical practice: Gradia direct anterior (GA), Tetric N-Ceram (TN), Ceram.X Sphere TEC one (CX), Filtek Z350XT (FT), Estelite sigma quick (ES). After creating a smooth surface with slide glass, five locations were randomly selected to measure surface gloss, and the average was the representative value of the specimen. Roughness was applied to the specimen under water pouring at the same speed and pressure using SiC paper #2400, 1200, and 400. The gloss unit of different SiC papers was measured. To evaluate the gloss unit and gloss retention between composite resins, one-way analysis of variance and Tukey multiple comparisons test were used. As a result of the study, there was a difference in gloss unit of specimens produced under the same conditions. Although the degree differed depending on the composite resin, there was also a difference in gloss retention. Based on the findings, composite resins show differences in gloss due to their different characteristics. Ceram.X Sphere TEC one (CX) showing the lowest gloss retention and Estelite sigma quick (ES) showing the highest.

알루미나-불소 복합 코팅제로 습식코팅된 스텐레스 강판의 화학 내식성 평가 (Chemical Evaluation of Corrosion Resistance for Stainless-Steel Plate Wet-Coated by Alumina-Fluoro Composite Coatings)

  • 정하영;김대성;이승호;임형미;김건;정민규
    • 한국재료학회지
    • /
    • 제22권12호
    • /
    • pp.643-649
    • /
    • 2012
  • Coatings composited with alumina and Perfluoro alkoxyalkane (PFA) resin were deposited on stainless steel plate (SUS304) to further improve corrosion resistance. Plate (ca. $10{\mu}m$) and/or nanosize (27~43 nm) alumina used as inorganic additives were mixed in PFA resin to make alumina-fluoro composite coatings. These coatings were deposited on SUS304 plate with wet spray coating and then the film was cured thermally. According to the amount and ratio of the two kinds of alumina having plate morphology and nano size, corrosion resistance of the film was evaluated under strong acids (HF, HCl) and a strong base (NaOH). The film prepared with the addition of 5~10 wt% alumina powders in PFA resin showed corrosion resistance superior to that of pure PFA resin film. However, for the film prepared with alumina content above 10 wt%, the corrosion resistance did not improve with the physical properties, such as surface hardness and adhesion. The film prepared with plate/nanosize (weight ratio = 1/2) alumina especially enhanced the surface hardness and corrosion resistance. This can be explained as showing that the plate and the nanosize alumina dispersed in PFA resin effectively suppressed the penetration of cations and anions due to the long penetration length and fewer defects that accompany the improved surface hardness under a serious environment of 10% HF solution for over 120 hrs.

수종(數種) 구치부(臼齒部) 충전용(充塡用) 복합(複合)레진의 물리적(物理的) 성질(性質)에 관(關)한 실험적(實驗的) 연구(硏究) (AN EXPERIMENTAL STUDY ON PHYSICAL PROPERTIES OF VARIOUS POSTERIOR RESTORATIVE COMPOSITE RESINS)

  • 박선재;박상진;민병순;최호영
    • Restorative Dentistry and Endodontics
    • /
    • 제12권1호
    • /
    • pp.7-24
    • /
    • 1986
  • The purpose of this study was to observe the compressive strength, compressive fatigue strength, surface hardness, water sorption and solubility of eight different posterior restorative composite resins. Eight composite resins were tested for their strength of the compressive and compressive fatigue with prepared two different types of specimens (I and T-type) using a Instron universal testing machine (model No. 1332). The hardness was measured with a Knoop hardness tester (MVH-2, Tokyo) for each cylindrical specimen, 7mm in diameter and 5mm thick. The water sorption and solubility were evaluated with the prepared composite resin disks, 20mm in diameter and 1mm thick. The results were as follows: 1. The compressive strength, compressive fatigue strength and hardness were noticed to be Increased by increasing the volume content of filler. 2. The compressive strength was appeared to be independent on the type of specimen, but the compressive fatigue strength was found to be greatly influenced by the type of specimens. 3. The composite resins having higher compressive strength had also higher compressive fatigue limits. 4. The compressive fatigue limits at $10^5$ stress cycles were about 50-80% of the compressive strength and were showen to be dependent on the materials and type of specimens. 5. The larger the filler particle size was, the lower was the water sorption. And the water sorption of BIS-GMA resin was higher than that of urethane resin. 6. The visible light-cured composite resin had a higher value of solubility than the chemically- cured composite resin. And the solubility tended to decrease by increasing the volume content of filler.

  • PDF

유치에서의 단일 색조 복합레진의 색조 적응력 평가 (Evaluation of the Color Adjustment Potential of Single-Shade Composite Resin in Primary Teeth)

  • 김용순;박호원;이주현;김해니
    • 대한소아치과학회지
    • /
    • 제50권1호
    • /
    • pp.113-120
    • /
    • 2023
  • 모든 유치에 알맞은 색조의 복합레진을 수복하는 것은 소아치과 의사에게 큰 어려움이다. 최근 개발된 단일 색조 복합레진은 구조색 현상을 기반으로 주변 치질과 유사한 색상을 나타낼 수 있다. 이 연구는 단일 색조 복합레진의 유치에서의 색조 적응력(Color adjustment potential, CAP)을 일반적인 다색조 복합레진과 비교하여 평가하기 위한 연구이다. 한 개의 단일 색조 복합레진과 두 개의 다색조 복합레진이 연구에 포함되었다. Single, dual 두 종류의 표본이 제작되어 평가되었다. Single 표본은 실험군 레진을 이용하여 제2유구치 인공치를 복제하여 제작하였다. Dual 표본은 발거된 제2유구치 협면에 와동을 형성한 뒤 실험군 레진을 수복하여 제작하였다. 측색계를 이용하여 발거된 치아 및 제작된 표본의 L*, a*, b* 값을 측정하였다. Single, dual 표본에 대한 ΔEab* 값과 CAP 값의 평균을 계산하였으며 Bonferroni 사후 분석을 이용하여 실험군 레진 간의 통계적 유의성을 확인하였다. 실험 결과 단일 색조 복합레진이 다른 복합레진들에 비해 유의하게 큰 ΔESingle 값을 나타내었다(p < 0.0167). 모든 실험군 레진 간 유의한 ΔEDual 값의 차이는 관찰되지 않았다. 단일 색조 복합레진은 다른 다색조 복합레진들과 비교 시 가장 높은 CAP 값을 나타내었다. 단일 색조 복합레진은 제2유구치에서 다른 다색조 복합레진에 비해 준수한 색조 적응력을 나타내었다. 단일 색조 복합레진은 제2유구치에서 색조 선택 과정을 단순화하면서 심미적인 수복물을 제공할 수 있을 것이다.

포스트 코아와 치근 계면에서의 미세누출에 관한 연구 (A STUDY OF THE MICROLEAKAGE AT THE POST AND CORE AND TOOTH INTERFACE)

  • 신지철;이선형;양재호;정헌영
    • 대한치과보철학회지
    • /
    • 제36권2호
    • /
    • pp.366-378
    • /
    • 1998
  • Post and core is used to restore endodontically treated teeth, and it is a very important part which supplies retention and support to the prosthesis. But occasionally, caries occured due to the microleakage at the post and core and tooth interface, the failure of prosthesis has happened. In this study, the microleakage of cast gold post and core, amalgam core, and composite resin core was investigated and compared. The coronal part of the extracted upper anterior teeth were removed and endodontically treated with conventional method. The teeth were divided into three groups. In group 1, cast gold post and core was cemented with resin cement and in group 2, ready-made post was cemented with resin cement and amalgam core was built. In group 3, ready-made post was cemented with resin cement and composite resin core was built. All specimens were thermocycled between $5^{\circ}C\;and\;55^{\circ}C$ with dwell time of 15 seconds, and immersed in 0.5% aqueous solution of basic fuchsin dye for 24 hours. After embedded in the epoxy resin, the specimens were sectioned longitudinally and observed with stereomicroscope with the magnification of 25. From the findings of this study, the following conclusions were obtained. 1. There was microleakage at the core/tooth interface of all specimens. 2. The microleakage of gold post and core was significantly less than those of the other two groups. 3. There was no significant difference between the microleakage of amalgam core and that of composite resin core.

  • PDF

불소 제재가 심미 수복 재료의 표면 구조에 미치는 영향 (THE EFFECT OF TOPICAL FLUORIDES ON SURFACE STRUCTURES OF VARIOUS ESTHETIC RESTORATIVE MATERIALS)

  • 김은영;최병재
    • 대한소아치과학회지
    • /
    • 제24권2호
    • /
    • pp.436-448
    • /
    • 1997
  • Topical fluoride application for children is a widely performed procedure in the field of Pediatric Dentistry for its dental caries prevention effects. However, it is recently recognized as having some unwanted effects on several esthetic restorative materials as it roughens the surfaces of the restorative materials. In order to evaluate the surface changes in esthetic restorative materials, the author immersed composite resin, glass ionomer cement, and resin-modified glass ionomer cement specimens in various topical fluoride agents and measured the weight loss and also, examined the specimens under the scanning electron microscope. The followings are the results : 1. All the specimens immersed in APF gel for 4 minutes showed statistically significant weight loss. (paired t-test, P<0.05). 2. There was no statistically significant weight loss for the resin-modified glass ionomer cement and composite resin groups immersed in sodium fluoride solution (paired t-test, P>0.05). 3. When the glass ionomer cement group was immersed in APF gel for 1 and 4 minutes, there was a statistically significant weight loss compare to other esthetic restorative materials (ANOVA, P<0.05). 4. In the resin-modified glass ionomer cement group and the composite resin group, weight loss in the APF gel 4 minutes immersion group was greater than the 1 minute immersion group, and it was statistically significant (ANOVA, P<0.05). 5. When the specimens were examined under scanning electron microscope, the surface changes were greatest in the order of glass ionomer cement, resin-modified glass ionomer cement, composite resin and also in the order of APF gel 4 minute immersion group, 1 minute immersion group, sodium fluoride immersion group, and control group.

  • PDF

ONE-STEP 접착제의 상아질 접착에 관한 연구 (A STUDY ON THE DENTIN BONDING OF ONE-STEP BONDING AGENT)

  • 조영곤;박성택;박광수
    • Restorative Dentistry and Endodontics
    • /
    • 제23권1호
    • /
    • pp.468-476
    • /
    • 1998
  • The purpose of this study was to observe the morphologic change of dentinal surface, adhesion in interface between dentin and bonding agents, and penetration pattern of resin tags into dentinal tubles according to bonding procedure of ONE-STEP universal adhesive system. Ten extracted human molars were mounted in dental stone and sectioned to expose mid-coronal occlusal dentin and again sectioned tooth crown apically. Specimens were randomly assigned to three groups for dentin conditioning with 32% phoshoric acid, two coats of bonding agents after dentin conditioning, and bond of composite resin. The surfaces of dentin were treated with etch ant and applied bonding agent, and bonded composite resin according to the directions of manufacturer. Specimens which were boned composite were sectioned longitudinally for observing interfaces between resin and dentin. Two of specimens which were sectioned longitudinally were immersed in 6 N HCL for 30 seconds and 1% NaOCL for 12 hours to partially demineralize and deproteinize the dentin substrate. Each specimen was mounted on a brass stub, sputter-coated with gold and observed under SEM. The result were as follows : 1. On the dentinal surface which was conditioned with 32% phosphoric acid. the smear layer was completely removed. orifices of dentinal tubules were opened 3-$5{\mu}m$ wide. and dentinal surface was irregular. 2. On the dentinal surface which was applied ONE-STEP. bonding agent. resin particles were observed on the orifices of dentinal tubules and intertubular dentin. 3. There were close adaptation between dentin and resin and were the pattern which composite invaded into dentin. 4. 1-$3{\mu}m$-wide hybrid layer was visible in the interface between dentin and resin. 5. Long and funnel shaped resin tags were observed in demineralized specimens. and the surfaces of tags were rough.

  • PDF

The effect of resin thickness on polymerization characteristics of silorane-based composite resin

  • Son, Sung-Ae;Roh, Hyoung-Mee;Hur, Bock;Kwon, Yong-Hoon;Park, Jeong-Kil
    • Restorative Dentistry and Endodontics
    • /
    • 제39권4호
    • /
    • pp.310-318
    • /
    • 2014
  • Objectives: This study examined the influence of the resin thickness on the polymerization of silorane- and methacrylate-based composites. Materials and Methods: One silorane-based (Filtek P90, 3M ESPE) and two methacrylate-based (Filtek Z250 and Z350, 3M ESPE) composite resins were used. The number of photons were detected using a photodiode detector at the different thicknesses (thickness, 1, 2 and 3 mm) specimens. The microhardness of the top and bottom surfaces was measured (n = 15) using a Vickers hardness with 200 gf load and 15 sec dwell time conditions. The degree of conversion (DC) of the specimens was determined using Fourier transform infrared spectroscopy (FTIR). Scratched powder of each top and bottom surface of the specimen dissolved in ethanol for transmission FTIR spectroscopy. The refractive index was measured using a Abbe-type refractometer. To measure the polymerization shrinkage, a linometer was used. The results were analyzed using two-way ANOVA and Tukey's test at p < 0.05 level. Results: The silorane-based resin composite showed the lowest filler content and light attenuation among the specimens. P90 showed the highest values in the DC and the lowest microhardness at all depth. In the polymerization shrinkage, P90 showed a significantly lower shrinkage than the rest two resin products (p < 0.05). P90 showed a significantly lower refractive index than the remaining two resin products (p < 0.05). Conclusions: DC, microhardness, polymerization rate and refractive index linearly decreased as specimen thickness linearly increased. P90 showed much less polymerization shrinkage compared to other specimens. P90, even though achieved the highest DC, showed the lowest microhardness and refractive index.

수평 포스트와 이중중합 복합레진으로 수복된 치관-치근 복합파절 치아의 파절 저항성에 관한 연구 (FRACTURE RESISTANCE OF CROWN-ROOT FRACTURED TEETH REPAIRED WITH DUAL-CURED COMPOSITE RESIN AND HORIZONTAL POSTS)

  • 장석우;이용근;경승현;유현미;오태석;박동성
    • Restorative Dentistry and Endodontics
    • /
    • 제34권5호
    • /
    • pp.383-389
    • /
    • 2009
  • 이 연구의 목적은 이중 중합복합레진과 수평 포스트를 이용하여 수복한 치관-치근 복합파절 치아의 수직파절 저항성을 알아보기 위한 것이다. 48개의 발치된 사람의 소구치에 실험적으로 치관-치근 복합파절을 일으킨 후 대조군 및 3개의 실험군에 (n=12) 각각 할당하였다. 대조군에서는 치아 파절편을 레진시멘트를 이용하여 접착한 후 근관치료를 시행하고, 근관와동을 이중중합 복합레진을 사용하여 충전하였다. 실험군에서는, 각각의 치아에 근관치료를 시행한 후 레진-포스트 군에서는 근관와동을 수평 포스트 및 이중중합 복합레진을사용하여 충전하였다. 레진 군에서는 근관와동을 포스트 없이 이중중합 복합레진만 사용하여 수복하였으며 아말감 코어 군에서는 근관와동을 접착 아말감을 사용하여 수복하였다. 이렇게 수복된 치아를 처음과 같은 방법으로 다시 치관-치근 복합파절을 유도하여 이때의 파절 저항성을 기록하고 이 값과 처음 파절을 유도하였을 때의 파절 저항성의 비를 계산하고 각 군별로 차이가 있는 지 검증하기 위해 Kruskal-Wallis test를 시행하였다. 수복된 치아의 파절저항성은 레진-포스트군, 대조군, 레진군, 접착 아말감 순으로 높았으며, 이 실험결과로 볼 때,치관-치근 복합파절 치아의 수복 시 수평 포스트를 사용하는 것이 재파절 방지를 위해 효과적 일 것으로 사료된다.

FRACTURE STRENGTH AND FRACTURE MODE OF RESIN ROOT ANALOGS RESTORED WITH VARIOUS POST AND CORE MATERIALS

  • Lee, Byung-Chul;Han, Jung-Suk;Lee, Jai-Bong;Yang, Jae-Ho;Lee, Sun-Hyung
    • 대한치과보철학회지
    • /
    • 제40권3호
    • /
    • pp.287-295
    • /
    • 2002
  • Statement of Problem. Endodontically treated teeth frequently required posts and cores to provide retention and resistance form for crowns. In spite of excellent mechanical properties of metal post and core, its metallic color can be detected through all ceramic restorations occasionally. To solve esthetic problems of metal post and core zirconia post system has been introduced recently. Purpose. The purpose of this study was to examine the fracture strength and mode of resin root analogs restored with zirconia, gold and titanium posts with resin, ceramic and metal cores after cementation with metal crowns. Materials and methods. To avoid the morphological variations of natural teeth, 40 root analogs were fabricated with composite resin. Forty resin root analogs were randomly assigned to four groups according to post and core materials: Group A: cast gold post and core and complete cast crowns, as control. Group B: titanium posts (Parapost, Coltent/Whaledent Inc., NJ, USA) and composite resin cores. Group C: zirconia posts (Cosmopost, Ivoclar AG, Schaan/Liechtenstein) and composite resin cores Group D: zirconia posts and heat-pressed ceramic cores (IPS Empress Cosmo Ingots, Ivoclar AG) After thermocycling ($5^{\circ}C{\sim}55^{\circ}C$, 30 sec.), cyclic loading was applied at 3mm below the incisal edge on the palatal surfaces at an angle of 135 degree to the long axis (2Hz, 50N, 50000cycles). Fracture strength was measured by universal testing machine (Instron, High Wycombe, UK) and fracture pattern of restored resin root analogs was also evaluated. Results and conclusion. Within the limitations of this study following results were drawn. 1. Resin root analogs restored with zirconia posts and composite resins demonstrated lowest fracture strength among tested groups. 2. There was no significant difference in the fracture strength between zirconia posts and heat pressed glass ceramic cores and cast gold posts and cores 3. The fracture strength of resin root analogs restored with titanium posts and composite resin cores was lower than that of gold posts and cores. 4. The deep oblique fracture lines were dominantly observed in root analogs restored with cast gold post and core and zirconia post and heat-pressed ceramic core groups.