• Title/Summary/Keyword: Composite Resin

Search Result 1,960, Processing Time 0.024 seconds

Effects of Various Diluents Included in the Resin Matrices on the Characteristics of the Dental Composites (레진 기질에 포함된 희석제들이 치과용 복합 재료의 특성 변화에 미치는 영향)

  • Yoo, Sun-Hwa;Kim, Chang-Keun
    • Polymer(Korea)
    • /
    • v.33 no.2
    • /
    • pp.153-157
    • /
    • 2009
  • The resin matrix in the dental composite is generally composed of 2,2-bis[4-(2-hydroxy-3-methacryloyloxy propoxy) phenyl] propane (Bis-GMA) as a base resin and triethylene glycol dimethacrylate (TEGDMA) as a diluent for the reduction of viscosity. The applications of dental composite were often limited in dentistry due to the relatively large amounts of volumetric shrinkage during polymerization and water uptake caused by the addition of TEGDMA to the resin matrix. In this study, in order to solve problems stemmed from the TEGDMA by reducing amount of diluent added to resin matrix, diethylene glycol dimethacrylate (DEGDMA) and ethylene glycol dimethacrylate (EGDMA) were explored as new diluents. A decrease in the volumetric shrinkage and an increase in the mechanical strength were observed by replacing TEGDMA in the dental composite to DEGDMA (or EGDMA). Reduction in the mechanical strength of the dental composite containing DEGDMA (or EGDMA), was not serious in comparison with that of the dental composite containing TEGDMA after water uptake.

Survival Rates of Class II Restoration in Primary Molar with Flowable Resin Composite (유동성 복합레진을 이용한 유구치 II급 수복의 생존율)

  • Seo, Hyejun;Park, Soyoung;Lee, Eungyung;Jeong, Taesung;Shin, Jonghyun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.48 no.1
    • /
    • pp.12-20
    • /
    • 2021
  • The purpose of this retrospective study was to evaluate the survival rate by comparing Class II restoration using flowable resin composite with stainless steel crown in primary molars. Electronic medical records and radiographs of 1,504 primary molars with proximal caries of 590 patients from June 2015 to August 2019 were analyzed. With the collected data, survival analysis was performed using the Kaplan-Meier method. The 1-year survival rate of flowable resin composite in the primary molar was 98.5%, 3-year survival rate was 87.7%, and mean survival time was 39 months. There was no statistically significant difference between flowable resin composite and stainless steel crown (p = 0.896). Within the limits of this study, Class II restoration using flowable resin composite can be considered a promising option for the treatment of proximal caries in primary molars.

Tensile Properties of CERP Composite with Different Resin Composition under Cryogenic Temperature (극저온 환경에서 탄소섬유강화 복합재료의 수지조성변화에 따른 인장 물성 측정)

  • Kim, Myung-Gon;Kang, Sang-Guk;Kong, Cheol-Won;Kim, Chun-Gon
    • Composites Research
    • /
    • v.20 no.4
    • /
    • pp.1-8
    • /
    • 2007
  • In this study, carbon fiber reinforced polymeric (CFRP) composites with different resin composition were manufactured and resin formulation in composite materials were presented through tensile tests for cryogenic use. Thermo-mechanical cyclic loading (up to 6 cycles) was applied to CFRP unidirectional laminate specimens from room temperature to $-150^{\circ}C$. Tensile tests were then performed at $-150^{\circ}C$ using an environmental test chamber. In addition, matrix-dominant properties such as the transverse and in-plane shear characteristics of each composite model were measured at $-150^{\circ}C$ to examine the effects of resin formulation on their interfacial properties. The tensile tests showed that the composite models with large amounts of bisphenol-A epoxy and CTBN modified rubber in their resin composition had good mechanical performance at cryogenic temperature (CT).

DEGREE OF COLOR CHANGE AND DYE DEPOSITION ONTO COMPOSITE RESINS AFTER OFFICE BLEACHING IN VITRO (표백술에 의한 복합 레진의 색변화와 색소 침착 정도)

  • Choi, Nak-Won;Son, Ho-Hyun
    • Restorative Dentistry and Endodontics
    • /
    • v.25 no.4
    • /
    • pp.599-605
    • /
    • 2000
  • Among the effects of tooth bleaching on composite resins, degree of color change and dye deposition onto composite resins after office bleaching were investigated in vitro. Seventy two disc-shaped resin samples were fabricated with hybrid type composite resin, Z-100 under 3 different environments(24 samples for each environment) characterized by 3 kinds of light-curing intensity and duration($250mW/cm^2$-20sec., $250mW/cm^2$-40sec., $550mW/cm^2$-20sec.). As control, one-third samples of each group were not treated with bleaching agent. The remaining two-thirds samples of each group were treated with bleaching agent(bleaching group). Then, before thermocycling procedure in coffee bath, the half of the samples treated with bleaching agent were polished(polishing group) with polishing system. SofLex, but the other half(not-polishing group) and control group were not polished. Another 72 samples were also made with microfilled type composite resin. Sillux Plus and treated according to the experimental procedures mentioned above. The color of each resin sample was measured before bleaching, after bleaching, and after thermocycling preceded by bleaching. And color difference was evaluated. It was concluded as follows: 1. The amount of color change of resin samples after office bleaching was not statistically significant(p>0.05). But the samples which were treated with bleaching agent showed more color change than that of control group. 2. After thermocycling in coffee bath, the amount of color change of resin samples between control and bleaching group was not statistically significant(p>0.05). 3. After thermocycling in coffee bath, the polishing procedure of resin samples showed no statistically significant difference(p>0.05) between polishing and not-polishing group in the aspect of color change.

  • PDF

THE EFFECT OF DELAYED COMPOSITE RESIN FILLING ON MICROTENSILE BOND STRENGTH (복합레진의 지연충전이 미세인장 결합강도에 미치는 영향)

  • Park, Hyun-Sik;Cho, Young-Gon;Park, Byung-Cheul;Kim, Jong-Uk;Choi, Hee-Young;Kim, Jong-Jin;Jin, Cheul-Hee;Yoo, Sang-Hoon;Ki, Young-Jae
    • Restorative Dentistry and Endodontics
    • /
    • v.29 no.3
    • /
    • pp.233-238
    • /
    • 2004
  • The purpose of this study was to evaluate the effect of immediate or delayed composite resin filling on dentinal microtensile bond strength (${\mu}TBS$) after applied the adhesive. The coronal dentin of human third molars was exposed. Single-Bond or One-Step was applied on the dentin surfaces. and composite resin were constructed immediately (group 1) or 5min., 10min., 15min., 20min. and 30min. (groups 2-6) after an adhesive was applied. The specimens were sectioned and made bar-shaped. Each surface area of them was about $1\textrm{mm}^2$. The ${\mu}TBS$ test was performed by EZ test. The results were analysed by One-way ANOVA and Tukey's test at 95% significance level. The results suggested that the ${\mu}TBS$ of Single-Bond to dentin was decreased when the composite resin was constructed 20min. and 30min. after Single-Bond was applied. But the ${\mu}TBS$ of One-Step was not affected by delayed composite resin filling.

The effect of red and white wine on color changes of nanofilled and nanohybrid resin composites

  • Tanthanuch, Saijai;Kukiattrakoon, Boonlert;Peerasukprasert, Thanwalee;Chanmanee, Nilobon;Chaisomboonphun, Parnchanok;Rodklai, Apisara
    • Restorative Dentistry and Endodontics
    • /
    • v.41 no.2
    • /
    • pp.130-136
    • /
    • 2016
  • Objectives: This study investigated the effect of red and white wine on color changes of nanofilled and nanohybrid resin composite. Materials and Methods: Sixty specimens of each resin composite were prepared. Baseline data color values were recorded using a spectrophotometer. Three groups of discs (n = 20) were then alternately immersed in red, white wine, and deionized water (as a control) for twenty five minutes and artificial saliva for five minutes for four cycles. Specimens were then stored in artificial saliva for twenty two hours. This process was repeated for five days following immersion in artificial saliva for two days. Subsequently, the process was repeated again. Data were analyzed by two-way repeated ANOVA, one-way ANOVA, and Tukey's HSD. Results: Red wine caused significantly higher color change (${\Delta}E^*$ > 3.3) than did white wine and deionized water (p < 0.05). Nanohybrid resin composites had significantly more color changes than nanofilled resin composite (p < 0.05). Conclusions: The effect of red and white wine on the color changes of resin composite restorative materials depended upon the physical and chemical composition of the restorative materials and the types of wine.

Effect of delayed time, surface treatment, and repair material on shear bond strength of repaired bis-acryl composite resin (수리된 비스 아크릴 복합 레진의 전단결합강도에 대한 지연시간, 표면처리, 수리 재료의 영향)

  • Park, Ji-su;Lee, Jae-In
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.34 no.2
    • /
    • pp.89-96
    • /
    • 2018
  • Purpose: The aim of this study was to evaluate the effect of delayed time, surface treatment, and repair materials on repair of bis-acryl composite resin through comparison of shear bond strength and to evaluate the utility of bis-acryl composite resin repair using polymethyl methacrylate resin. Materials and Methods: A total of 90 bis-acryl composite resin specimens were fabricated and classified into 9 test groups, each of 10 pieces according to delayed time, surface treatment and repair material. The shear bond strength of each specimen was measured using a universal testing machine immediately after fabrication and analyzed using a statistical analysis program (IBM SPSS statistics 20). After the shear bond strength measurement, the fracture surface of the specimen was observed. Results: The highest shear bond strength ($17.54{\pm}3.14MPa$) was observed in the experimental group bonded immediately with a light-curing flowable composite resin using a bonding agent. Conclusion: When repairing bis-acryl composite resin, it is necessary to consider whether to remake according to the delayed time. For effective repair, it is desirable to consider appropriate materials and surface treatment methods according to the site or purpose of use.

AN EXPERIMENTAL STUDY ON THE SHEAR BOND STRENGTHS OF COMPOSITE RESIN TO AIR-ABRADED ENAMEL AND DENTIN (표면처리방법에 따른 복합레진의 결합강도에 관한 실험적 연구)

  • Shin, Jae-Ho;Jang, Ki-Taeg;Hahn, Se-Hyun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.24 no.1
    • /
    • pp.112-124
    • /
    • 1997
  • According to extensive use of composite resin which have superior esthetic property, every effort on improving bonding strength between a tooth and composite resin has been continued. Acid etching technique is a method that micro-etches the tooth surface which provides bonding with composite resin possible. Recently, there were several reports that mechanical treatment obtained from air-abrasion can provide similar bonding strength with acid etching technique. So, this experimental study was designed to compare the shear bonding strength between using air-abrasion technique and using acid etching technique. Initially, bovine teeth were divided into enamel and dentin experimental groups. Respectively each group was categorized into three subgroups. One subgroup was acid etched with 35% phosphoric acid, then bonded with composite resin. The other subgroup was air-abraded with $50{\mu}m$ $Al_2O_3$ particles sprayed with 160psi air pressure using air abrasion unit(KCP-1000, A.D.T., U.SA), and composite resin was bonded. In another subgroup, composite resin was bonded after acid etching following air-abrasion. So, enamel experimental groups were made of E1 (acid etched only), E2(air-abraded only), E3(acid etched following air-abraded), and dentin experimental groups were made of D1(acid etched only), D2(air-abraded only), D3(acid etched following air-abraded). Each subgroup had 10 specimens. Dentin bonding system(Scotchbond Multi-purpose, 3M Co., U.S.A.) and composite resin(Z-100, 3M Co., U.S.A.) were applied on treated surface using 5mm diameter gelatin capsule as manufacturer's direction. After 1200 times thermocycling between $5^{\circ}C$ and $55^{\circ}C$, shear bond strength was measured in 5mm/min crosshead speed with Instron(Instron Co., U.S.A.), and also treated enamel and dentin were observed with SEM(JEOL Co., Japan). The following results were obtained: 1. In the enamel experimental groups, acid etched following air-abraded group had highest shear bond strength, but there was no significant difference compared to acid etched group. Air-abraded only group had lowest shear bond strength, and there was significant difference compared to the rest of groups. 2. In the dentin experimental groups, acid etched following air-abraded group had highest shear bond strength, but there was no significant difference compared to acid etched group. Air-abraded only group had lowest shear bond strength, and there was significant difference compared to the rest of groups. 3. In the SEM study, air-abraded enamel and dentin had irregular and rough surfaces.

  • PDF

5 YEARS EVALUATION OF COMPOSITE RESIN RESTORATION ON PERMANENT FIRST MOLAR IN CHILDREN (어린이 제 1 대구치 복합 레진 수복물의 5년 후 임상평가)

  • Kim, In-Young;Kim, Jae-Moon;Jeong, Tae-Sung;Kim, Shin
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.35 no.1
    • /
    • pp.110-117
    • /
    • 2008
  • Clinical performance of resin-based composite material depends on case selection and on the proficiency of the operator. Especially, composite resin restoration on permanent first molar in children have more limitations clinically than adult patients according to stage of tooth eruption and patient's compliance. This study was designed to evaluate the clinical performance of posterior composite resin restoration in children after 5 years. 35 teeth of 16 patients who were received composite resin restoration on permanent first molar in Department of Pediatric dentistry, Pusan National University Hospital between January 2001 and December 2001 were evaluated based on Modified USPHS criteria. From the finding in this study, following conclusions can be made. 1. 6 teeth(17%) of 35 teeth was replaced, so 5-years survival rate of posterior composite resin restoration is 82.9%. 2. As results of each evaluation criteria, on color match, anatomic form, surface roughness, sensitivity/ discomfort, ideal A grade score was 86.2%, 93.1%, 86.2%, 86.2%, clinically accepted B grade score was 13.8%, 0%, 13.8%, 10.3%. On marginal adaptation and marginal discoloration, A grade score was 13.8%, 44.8% and B grade score was 79.3%, 34.5% and secondary caries rate was 20.7%. 3. 69.1% of teeth (20 teeth) was clinically accepted on all evaluation criteria.

  • PDF

Polymerization Shrinkage Behavior Measured by Digital Image Correlation for Methacrylate-based and Silorane-based Composites During Dental Restoration (디지털 이미지 상관법을 이용한 Methacrylate기질과 Silorane기질 복합레진의 치아 수복 시 중합수축거동)

  • Park, Jung-Hoon;Choi, Nak-Sam
    • Composites Research
    • /
    • v.33 no.3
    • /
    • pp.125-132
    • /
    • 2020
  • The polymerization shrinkage behavior of dimethacrylate-based composite (Clearfil AP-X, Kuraray) and silorane-based composite (Filtek P90, 3M ESPE) used for dental composite restorations was measured using digital image correlation method. The stress distribution on the surface of specimen was calculated by finite element analysis with equivalent elastic modulus and was compared with the measured shrinkage distribution. Camera images were monitored by a CCD camera during and after the irradiation of light. As a result of the DIC analysis, a non-uniform shrinkage distribution was observed in both composite resins, and the resin core inside the ring specimen had free flowability, leading to in greater shrinkage strain than the resin/ring interfacial region. It was observed that as the distance from the center of the resin increased, the radial average shrinkage strain decreased. The radial average shrinkage strain during light irradiation occurred to be 33% for P90 and 57% for AP-X of the entire strain at the end of the test. The shrinkage behavior of P90 and AP-X was measured to be significantly different from each other during light irradiation. In the resin near the resin/ring interface, it was confirmed that the tensile strain rapidly formed to increase after light irradiation, causing a tensile stressed, interface weak.