• Title/Summary/Keyword: Composite Immersion Experiment

Search Result 5, Processing Time 0.017 seconds

A SPECTROPHOTOMETRIC STUDY ON DISCOLORATION OF RESTORATIVE COMPOSITE RESINS IN COFFEE AND ARTIFICIAL SALIVA (분광광도계를 이용한 커피와 인공타액에서의 수복용 복합레진의 변색에 대한 연구)

  • Eom, Seung-Hee;Cho, Hyo-Sun;Lee, Chung-Sik
    • Restorative Dentistry and Endodontics
    • /
    • v.21 no.2
    • /
    • pp.530-545
    • /
    • 1996
  • The purpose of this study was to investigate by spectrophotometry the changes in color parameters of composite resins after exposure to distilled water, filtered coffee, and artificial saliva. Five kinds of fine particle composite resin in experiment 1, and six kinds of composite resin in experiment 2 were used. In experiment 1, each group of composite resin was stored in distilled water at $4^{\circ}C$, $50^{\circ}C$, and filtered coffee solution at $4^{\circ}C$, $50^{\circ}C$. And then each specimen was measured by spectrophotometer. Measurements were repeated in 1 hour, 2 hours, 4 hours, 8 hours, 16 hours, 24 hours, and 48 hours. In experiment 2, all specimens of each brand were stored in distilled water at $37^{\circ}C$, artificial saliva not contained mucin at $37^{\circ}C$, and artificial saliva contained mucin at $37^{\circ}C$. All specimens of each brand were measured by spectrophotormeter in 1 week, 2 weeks, 4 weeks, 8 weeks, and up to 12 weeks. The results were as follows : 1. In cold coffee, five of fine particle composite resins showed ${\Delta}E{^*}_{ab}$ values less than 2. However, in hot coffee ${\Delta}E{^*}_{ab}$ values of Amelogen Universal and Prisma TPH were higher than those of Conquest Crystal, ${\AE}$litefil and Z100. 2. Z100 and ${\AE}$litefil had better cleansibility of extrinsic coffee staining than Amelogen Universal, Conquest Crystal and Prisma TPH. 3. In distilled water and artificial saliva not contained mucin, five of fine particle composite resin showed ${\Delta}E{^*}_{ab}$ values less than 2 up to 12 weeks. However, Silux Plus showed higher than ${\Delta}E{^*}_{ab}$ values of fine particle composite resin. 4. As an immersion solution for discoloration experiment, artificial saliva not contained mucin showed similar appearance as distilled water. However, artificial saliva contained mucin had different appearance from the others. 5. In artificial saliva contained mucin, ${\AE}$litefil, Prisma TPH and Z100 showed ${\Delta}E{^*}_{ab}$ values less than 1 up to 12 weeks. However, Silux Plus, Amelogen Universal and Conquest Crystal showed ${\Delta}E{^*}_{ab}$ values more than 1 up to 12 weeks. But, Conquest Crystal showed different characteristics of chromacity difference value(less chromatic) and lightness difference value(lighter) from Silux Plus and Amelogen Universal.

  • PDF

Analysis of the integral fuel tank considering hygrothermal enviornmental factors (열습도 환경요소를 고려한 일체형 복합재 연료탱크의 해석)

  • Moon, Jin-Bum;Kim, Soo-Hyun;Kim, Chun-Gon
    • Composites Research
    • /
    • v.20 no.5
    • /
    • pp.64-69
    • /
    • 2007
  • Matrix dominant properties of composites are largely degraded under harmful environments such as temperature and humidity. Therefore we should consider the harmful environmental factors in the design of an UAV integral fuel tank subjected to high temperature and high humidity. The harmful environment experiment was performed for carbon/epoxy composites made of a unidirectional prepreg USN175B, and a plain woven fabric prepreg WSN3. The immersion experiment was performed under $90^{\circ}C$. The specimens were tested when the weight gam of specimen was saturated. The specimens were tested under $74^{\circ}C$ to obtain tensile and inplane shear properties. The results showed that the matrix dominant properties were extremely degraded by hygrothermal environment. To consider the variability of load, the anti-optimization method was applied. By using this method, the worst load case was found by comparing the load convex model and stability boundary. The stability boundary was obtained by analysis of the integral wing fuel tank of UAV using degraded properties. To do this, it was known that the worst load case of the integral wing fuel tank was the hovering mode load case.

LN2 storage test and damage analysis for a Type 3 cryogenic propellant tank (타입 3 극저온 추진제 탱크의 액체질소저장 시험 및 파손 분석)

  • Kang, Sang-Guk;Kim, Myung-Gon;Park, Sang-Wuk;Kong, Cheol-Won;Kim, Chun-Gon
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.35 no.7
    • /
    • pp.592-600
    • /
    • 2007
  • Nowadays, researches for replacing material systems for cryotanks by composites have been being performed for the purpose of lightweight launch vehicle. In this paper, a type 3 propellant tank, which is composed of the composite developed for cryogenic use and an aluminum liner, was fabricated and tested considering actual operating environment, that is, cryogenic temperature and pressure. For this aim, liquid nitrogen (LN2) was injected into the fabricated tank and in turn, gaseous nitrogen (GN2) was used for pressurization. During this test procedure, strains and temperatures on the tank surface were measured. The delamination between hoop layer and helical one, was detected during the experiment. Several attempts were followed to investigate the cause analytically and experimentally. Thermo-elastic analysis in consideration of the progressive failure was done to evaluate the failure index. Experimental approach through a LN2 immersion test of composite/aluminum ring specimens suitable for simulating the Type 3 tank structure.

Study on the correlation between long-term exposure tests and accelerated corrosion tests by the combined damage of salts (염해 및 복합열화에 의한 부식촉진시험과 장기폭로 시험의 상관성에 관한 연구)

  • Park, Sang Soon;Lee, Min Woo
    • Corrosion Science and Technology
    • /
    • v.13 no.6
    • /
    • pp.214-223
    • /
    • 2014
  • Interest in the durability assessment and structural performance has increased according to an increase of concrete structures in salt damage environment recent years. Reliable way ensuring the most accelerated corrosion test is a method of performing the rebar corrosion monitoring as exposed directly to the marine test site exposure. However, long-term exposure test has a disadvantage because of a long period of time. Therefore, many studies on reinforced concrete in salt damage environments have been developed as alternatives to replace this. However, accelerated corrosion test is appropriate to evaluate the critical chlorine concentration in the short term, but only accelerated test method, is not easy to get correct answer. Accuracy of correlation acceleration test depends on the period of the degree of exposure environments. Therefore, in this study, depending on the concrete mix material, by the test was performed on the basis of the composite degradation of the salt damage, and investigate the difference of corrosion initiation time of the rebar, and indoor corrosion time of the structure, of the marine environment of the actual environments were inuestigated. The correlation coefficient was derived in the experiment. Long-term exposure test was actually conducted in consideration of the exposure conditions submerged zone, splash zone and tidal zone. The accelerated corrosion tests were carried out by immersion conditions, and by the combined deterioration due to the carbonation and accelerated corrosion due to wet and dry condition.

The Effect of 15% Carbamide Peroxide on the Surface Roughness and Staining of Esthetic Restoratives (15% Carbamide Peroxide가 심미수복재의 표면조도와 착색에 미치는 영향)

  • Kim, Soo-Hwa;Choi, Hye-Sook;Roh, Jj-Yeon;Kim, Kwang-Mahn
    • Journal of dental hygiene science
    • /
    • v.13 no.2
    • /
    • pp.165-173
    • /
    • 2013
  • The purpose of this study was to evaluate the surface change after 15% carbamide peroxide home bleaching to various restorative materials (composite resin [CR], resin modified glass ionomer [RMGI] and glass ionomer [GI]) and to observe the effect of surface condition of the materials on re-staining. Three esthetic restorative materials (Filtek Z250, 3M, USA; Fuji II LC, GC, Japan; Fuji II, GC, Japan) were used in this study. Twenty specimens per material group were made and divided into two groups (bleached and control). The specimens were immersed in coffee after applying bleaching agent. The color change and surface roughness were measured before and after bleaching and after immersion in coffee. The data were analyzed with SPSS 18.0. The results were as follows: 1. The color of all experiment groups was significantly changed after bleaching (p<0.05). RMGI was the greatest value of ${\Delta}E^*$ and ${\Delta}L^*$. GI and CR groups were in ordering (p<0.05). The ${\Delta}a^*$ value was decreased GI, RMGI and CR. RMGI was only significantly decreased in ${\Delta}b^*$ value (p<0.05). 2. The surface roughness before and after bleaching was significantly different on CR, RMGI and GI (p<0.05). 3. After staining with coffee, the value of ${\Delta}E^*$ was increased in GI, RMGI and CR, furthermore GI and RMGI showed significant difference in the bleaching groups (p<0.05). The ${\Delta}L^*$ value of GI and RMGI was significantly decreased. 4. The change of surface roughness after staining was not significantly different in all groups (p>0.05). The maintenance of color stability in esthetic restorations is one of the most important properties. Tooth whitening is for the aesthetic. Therefore, dental professionals should notice to patients about re-staining after tooth whitening. They should give an instruction that how to prevent and which kinds of agents could be stained.