• 제목/요약/키워드: Composite Floor System

검색결과 78건 처리시간 0.028초

Pseudo-dynamic test of the steel frame - Shear wall with prefabricated floor structure

  • Han, Chun;Li, Qingning;Jiang, Weishan;Yin, Junhong;Yan, Lei
    • Steel and Composite Structures
    • /
    • 제20권2호
    • /
    • pp.431-445
    • /
    • 2016
  • Seismic behavior of new composite structural system with a fabricated floor was studied. A two-bay and three-story structural model with the scale ratio of 1/4 was consequently designed. Based on the proposed model, multiple factors including energy dissipation capacity, stiffness degradation and deformation performance were analyzed through equivalent single degree of freedom pseudo-dynamic test with different earthquake levels. The results show that, structural integrity as well as the effective transmission of the horizontal force can be ensured by additional X bracing at the bottom of the rigidity of the floor without concrete topping. It is proved that the cast-in-place floor in areas with high seismic intensity can be replaced by the prefabricated floor without pouring surface layer. The results provide a reliable theoretical basis for the seismic design of the similar structural systems in engineering application.

천장 인필시스템에 따른 장수명주택 경량벽체의 성능실험에 관한 연구 (A Study on the Performance Experiments of Lightweight Wall of Long-life Housing by Ceiling Infill System)

  • 서동구;이종호;김은영;황은경
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2018년도 춘계 학술논문 발표대회
    • /
    • pp.247-248
    • /
    • 2018
  • In order to secure the variability of long-life housing, dry walls are used. The composite gypsum board panel is the most frequently used infill system for the wall, and it is an excellent construction method in terms of constructability and economic feasibility. However, there are also problems such as the destruction of Ondol pipes at the bottom floor and being unable to fix the light weight steel frame (M-bar) when a variable composite gypsum board panel is used. To solve such problems, a wall with a method of fixing only the top part without fixing the bottom floor is developed, but it is difficult to identify the durability of ceiling frame according to the tensile force of stud and the safety according to the Stiffness and impact resistance (soft body) of ceiling frame. Therefore, this study verified the effectiveness of infill system for the wall by conducting experiment on the stiffness and impact resistance of composite gypsum board panel according to the reinforcement of ceiling frame (wooden frame, double saw-toothed bracket, Cross M-bar). As a result, it was possible to secure the safety of wooden frame while the impact resistance and the Stiffness of double saw-toothed bracket and cross M-bar were not secured.

  • PDF

Lightweight Floor Systems for Tall Buildings: A Comparative Analysis of Structural Material Efficiencies

  • Piyush Khairnar
    • 국제초고층학회논문집
    • /
    • 제12권2호
    • /
    • pp.145-152
    • /
    • 2023
  • Typical floor systems in contemporary tall buildings consist of reinforced concrete or composite metal deck over framing members and account for a majority of the structural weight of the building. The use of high-density materials, such as reinforced concrete and steel, increases the weight of floor systems, reducing the system's overall efficiency. With the introduction of high-performance materials, mainly mass timber products, and fiber-reinforced composites, in the construction industry, designers and engineers have multiple options to choose from when selecting structural materials. This paper discusses the application of mass timber and carbon fiber composites as structural materials in floor systems of tall buildings. The research focused on a comparative analysis of the structural system efficiency for five different design options for tall building floor systems. Finite Element Analysis (FEA) method was adopted to develop a simulation framework, and parametric structural models were simulated to evaluate the structural performance under specific loading conditions. Simulation results revealed the advantages of lightweight structural materials to improve system efficiency and reduce material consumption. The impact of mechanical properties of materials, loading conditions, and issues related to fire engineering and construction were briefly discussed, and future research topics were identified in conclusion.

Shear capacity equation for channel shear connectors in steel-concrete composite beams

  • Paknahad, Masoud;Shariati, Mahdi;Sedghi, Yadollah;Bazzaz, Mohammad;Khorami, Majid
    • Steel and Composite Structures
    • /
    • 제28권4호
    • /
    • pp.483-494
    • /
    • 2018
  • In this research the effect of high strength concrete (HSC) on shear capability of the channel shear connectors (CSC) in the steel concrete composite floor system was estimated experimentally and analytically. The push-out test was carried out for assessing the accurateness of the proposed model (nonlinear and finite element model) for the test specimens. A parametric analysis was conducted for predicting the shear capacity of the connectors (CSC) in the HSC. Eight push-out specimens of different sizes with different strength levels were tested under the monotonic loading system. The aim of this study was to evaluate the efficacy of the National Building Code of Canada (NBC) of Canada for analysing the loading abilities of the CSC in the HSC. Using the experimental tests results and verifying the finite element results with them, it was then confirmed by the extended parametric studies that the Canadian Design Code was less efficient for predicting the capacity of the CSC in the HSC. Hence, an alternative equation was formulated for predicting the shear capacity of these connectors during the inclusion of HSC for designing the codes.

장스팬이 가능한 친환경 공동주택용 철골 프리캐스트 합성보 개발 (Development of Long-Span Steel-Precast Composite Beam for Green Apartment Building)

  • 윤태호;홍원기;박선치;윤대영
    • KIEAE Journal
    • /
    • 제11권1호
    • /
    • pp.9-14
    • /
    • 2011
  • Currently, the multi-residential apartments used in Korea are mostly bearing wall apartments which don't satisfy consumers for the lack of architectural plan flexibility. And due to remodelling-incompatible, bearing wall apartments have to be reconstructed. It is, thus, necessary to develop multi-residential apartments utilizing composite beam that can replace the conventional bearing wall-type apartment buildings. Composite beams proposed in this paper ensure modification of space and quality control, while the floor heights are maintained at the same floor height as in bearing wall structures. This study analyzes the experimental behavior of composite beams with proper combination of structural steel, reinforced concrete, and precast concrete. By comparing with the theoretical analysis and experimental results, the accuracy of flexural moment capacity and neutral axis was evaluated. The experiments were performed by two simply-supported specimens using loading and unloading. When the analysis results were compared with the experimental results, the flexural moment capacity of the composite beam was shown with an error of approximately -0.5 to 0.1% at the maximum load limit state.

Experimental study on vibration serviceability of cold-formed thin-walled steel floor

  • Bin Chen;Liang Cao;Faming Lu;Y. Frank Chen
    • Steel and Composite Structures
    • /
    • 제46권4호
    • /
    • pp.577-589
    • /
    • 2023
  • In this study, on-site testing was carried out to investigate the vibration performance of a cold-formed thin-walled steel floor system. Ambient vibration, walking excitation (single and double persons), and impulsive excitation (heel-drop and jumping) were considered to capture the primary vibration parameters (natural frequencies, damping ratios, and mode shapes) and vertical acceleration response. Meanwhile, to discuss the influence of cement fiberboard on structural vibration, the primary vibration parameters were compared between the systems with and without the installation of cement fiberboard. Based on the experimental analysis, the cold-formed thin-walled steel floor possesses high frequency (> 10 Hz) and damping (> 2%); the installed cement fiberboard mainly increases the mass of floor system without effectively increasing the floor stiffness and may reduce the effects of primary vibration parameters on acceleration response; and the human-structure interaction should be considered when analyzing the vibration serviceability. The comparison of the experimental results with those in the AISC Design Guide indicates that the cold-formed thin-walled steel floor exhibits acceptable vibration serviceability. A crest factor 𝛽rp (ratio of peak to root-mean-square accelerations) is proposed to determine the root-mean-square acceleration for convenience.

층간소음 대응형 경량합성바닥판에 대한 휨성능 평가 (Evaluation on Flexural Performance for Light-Weight Composite Floor with Sound Reduction System)

  • 배규웅;이상섭;박금성;허병욱;홍성엽
    • 한국강구조학회 논문집
    • /
    • 제26권3호
    • /
    • pp.241-250
    • /
    • 2014
  • 층간소음에 대응할 수 있는 유닛모듈러 경량합성바닥 구조시스템을 제안하고, 이러한 바닥판에 대한 내력 및 거동을 실험연구를 통해 평가하고자 하는 것이 본 연구의 목표이다. 평데크와 철근트러스 데크를 활용하여 제안된 형상별로 각각 3개씩 총 9개의 경량합성바닥판 실험체를 제작하여 실험을 수행하였다. 실험결과, 실험체의 파괴 형태는 바닥판의 중앙부에서 처짐으로 인한 휨변형에 의해 지배되었으며 종국으로 바닥판 상부에 콘크리트 압괴가 발생하는 동일한 파괴양상을 나타내었다. 또한, 사용하중 상태에서는 구조적으로 안전하고, 사용성 측면에서도 우수한 것으로 나타났다. 이론적 공칭하중에 대한 실험 항복하중의 비는 0.86~1.27의 분포로 평균 1.04로 나타났으며, 분포도 측면에서 변동계수는 0.154로 나타나 비교적 잘 일치하는 것으로 나타났다.

합성보의 시공중 처짐이 합성데크슬래브의 콘크리트 고임에 미치는 영향 (Effect of Constructional Deflection of Composite Beam on Concrete Ponding in Metal Deck Slab)

  • 김영찬
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제6권4호
    • /
    • pp.99-106
    • /
    • 2002
  • 합성데크구조에서 보와 바닥판은 공사중 처짐이 발생한다. 이 렌즈형태의 처짐은 건물의 사용성 문제를 야기시킨다. 따라서, 수평이 되도록 보정되어야 한다. 수평보정을 위한 몇가지 방법이 있는데 (1) 부재의 강성을 증가하거나 (2) 지주로 바닥을 받치거나 (3) 보에 치올림을 두거나 (4) 추가 콘크리트를 타설한다. 본 연구에서는 추가콘크리트를 이용하여 바닥면을 수평보정하는 경우 여러 가지의 바닥크기에 대하여 추가콘크리트의 중량과 체적을 비교 검토하였다.

평판 부착형 제진시스템을 이용한 구조기인 소음 저감에 관한 연구 (Noise control of a slab using the laminated composite damping system)

  • 황재승;김광용;홍건호
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2009년도 춘계학술대회 논문집
    • /
    • pp.403-407
    • /
    • 2009
  • It is reported that the heavy weight floor impact noise of a slab system is very sensitive to the location of microphone and impact load. In addition, it is known that the aspect raio, thickness and boundary condition of a slab also have great effect on the noise induced by impact load. However, the effect has been mainly evaluated by experimental test and numerical analysis is nearly performed to verify the effect quantitatively. In this study, the effect of the aspect ratio, thickness and boundary condition on the heavy weight floor impact noise is examined through numerical analysis for simple rectangular slab system. The results show that the thickness and boundary condition have a strong correlation with the noise of the slab, on the contrary, the aspect ratio has little relation with the noise.

  • PDF

역삼각 트러스 거더로 보강된 더블 골 데크 성능 평가 (Structural Performance of Double Rip Decks Reinforced with Inverted Triangular Truss Girders)

  • 손홍준;김영호;정경수;김대진
    • 한국전산구조공학회논문집
    • /
    • 제30권6호
    • /
    • pp.559-566
    • /
    • 2017
  • 본 논문은 시공단계에서 가설지주 설치를 요구하지 않는 역삼각 트러스 거더로 보강된 새로운 합성 데크플레이트 시스템을 제안한다. 제안된 시스템은 기존 시스템 대비 증가된 강성과 강도를 보유할 뿐 아니라 절대 층고 변화를 최소 수준으로 낮출 수 있으며 기존의 H형강 및 U형 합성보와 같은 다양한 형태의 합성보 부재와 함께 사용될 수 있다. 제안된 시스템의 시공단계 하중에 대한 구조적 성능을 평가하기 위해 5.5m의 스팬을 갖는 5개의 시험체를 제작하여 현장 조건과 유사한 재하하중을 단계적으로 적용시켜 실험을 수행하였다. 실험결과로부터 각 시험체 별 하중-변위 그래프를 구해 비선형 3차원 유한요소해석결과와 비교하였다. 비교 결과 보강 트러스 거더와 데크플레이트 사이에 효율적인 하중 분배가 이루어져 두 구조요소가 잘 일체화되었을 뿐 아니라 시공단계 하중에서의 최대 처짐이 건축구조기준의 제한치를 하회하여 사용성 조건을 잘 만족시킴을 알 수 있다.