• Title/Summary/Keyword: Compliance Method

Search Result 891, Processing Time 0.034 seconds

A Study on Major Safety Problems and Improvement Measures of Personal Mobility (개인형 이동장치의 안전 주요 문제점 및 개선방안 연구)

  • Kang, Seung Shik;Kang, Seong Kyung
    • Journal of the Society of Disaster Information
    • /
    • v.18 no.1
    • /
    • pp.202-217
    • /
    • 2022
  • Purpose: The recent increased use of Personal Mobility (PM) has been accompanied by a rise in the annual number of accidents. Accordingly, the safety requirements for PM use are being strengthened, but the laws/systems, infrastructure, and management systems remain insufficient for fostering a safe environment. Therefore, this study comprehensively searches the main problems and improvement methods through a review of previous studies that are related to PM. Then the priorities according to the importance of the improvement methods are presented through the Delphi survey. Method: The research method is mainly composed of a literature study and an expert survey (Delphi survey). Prior research and improvement cases (local governments, government departments, companies, etc.) are reviewed to derive problems and improvements, and a problem/improvement classification table is created based on keywords. Based on the classification contents, an expert survey is conducted to derive a priority improvement plan. Result: The PM-related problems were in 'non-compliance with traffic laws, lack of knowledge, inexperienced operation, and lack of safety awareness' in relation to human factors, and 'device characteristics, road-drivable space, road facilities, parking facilities' in relation to physical factors. 'Management/supervision, product management, user management, education/training' as administrative factors and legal factors are divided into 'absence/sufficiency of law, confusion/duplication, reduced effectiveness'. Improvement tasks related to this include 'PM education/public relations, parking/return, road improvement, PM registration/management, insurance, safety standards, traffic standards, PM device safety, PM supplementary facilities, enforcement/management, dedicated organization, service providers, management system, and related laws/institutional improvement', and 42 detailed tasks are derived for these 14 core tasks. The results for the importance evaluation of detailed tasks show that the tasks with a high overall average for the evaluation items of cost, time, effect, urgency, and feasibility were 'strengthening crackdown/instruction activities, education publicity/campaign, truancy PM management, and clarification of traffic rules'. Conclusion: The PM market is experiencing gradual growth based on shared services and a safe environment for PM use must be ensured along with industrial revitalization. In this respect, this study seeks out the major problems and improvement plans related to PM from a comprehensive point of view and prioritizes the necessary improvement measures. Therefore, it can serve as a basis of data for future policy establishment. In the future, in-depth data supplementation will be required for each key improvement area for practical policy application.

Effect of Thyroid Hormone on the Ischemia-Reperfusion Injury in the Canine Lung (갑상선 호르몬이 잡견 폐장의 허혈-재관류 손상에 미치는 영향)

  • 김영태;성숙환
    • Journal of Chest Surgery
    • /
    • v.32 no.7
    • /
    • pp.637-647
    • /
    • 1999
  • Background: Ischemia-reperfusion injury is one of the major contributing causes of early graft failure in lung transplantation. It has been suggested that triiodothyronine (T3) may ameliorate ischemia-reperfusion injury to various organs in vivo and in vitro. Predicting its beneficial effect for ischemic lung injury, we set out to demonstrate it by administering T3 into the in situ canine ischemia-reperfusion model. Material and Method: Sixteen adult mongrel dogs were randomly allocated into group A and B. T3 $(3.6\mug/kg)$ was administered before the initiation of single lung ischemia in group B, whereas the same amount of saline was administered in group A. Ischemia was induced in the left lung by clamping the left hilum for 100 minutes. After reperfusion, various hemodynamic parameters and blood gases were analyzed for 4 hours while intermittently clamping the right hilum in order to allow observation of the injured left lung function. Result: Arterial oxygen partial pressure $(PaO_2)$ decreased 30 minutes after reperfusion and recovered gradually thereafter in both groups. In group B the decrease of $PaO_2$ was less marked than in group A. The recovery of $PaO_2$ was faster in group B than in group A. The differences between the two groups were statistically significant from 30 minutes after reperfusion $(125\pm34$ mmHg and $252\pm44$ mmHg, p<0.05) until the end of the experiment $(178\pm42$mmHg and $330\pm37$ mmHg, p<0.05). The differences in the arterial carbon dioxide pressure, airway pressure and lung compliance showed no statistical significance. The malondialdehyde (MDA) level, measured from the tissue obtained 240 minutes after reperfusion, was lower in group B $(0.40\pm0.04\mu$M) than in group A $(0.53\pm0.05\mu$M, p<0.05). The ATP level of group B $(0.69\pm0.07\mu$M/g) was significantly higher than that of group A $(0.48\pm0.07\mu$M/g, p<0.05). The microscopic exami nation revealed varying degrees of injury such as perivascular neutrophil infiltration, capillary hemorrhage and interstitial congestion. There were no differences in the microscopic findings between the two groups. CONCLUSION T3 has beneficial effects on the ischemic canine lung injury including preservation of oxygenation capacity, less production of lipid peroxidation products and a higher level of tissue ATP. These results suggest that T3 is effective in pulmonary allograft preservation.

  • PDF

The Dynamic and Histologic Changes of Variously Fixed Bovine Pericardiums Specimens after Mechanical Fatigue Stimuli (다양한 고정 처리법을 이용한 소 심낭의 기계적 피로 자극 후 역학적 및 조직학적 변화)

  • Chang, Hyoung-Woo;Kim, Yong-Jin;Kim, Soo-Hwan;Park, Ji-Eun;Park, Chun-Soo;Kim, Woong-Han;Kim, Kyung-Hwan
    • Journal of Chest Surgery
    • /
    • v.42 no.2
    • /
    • pp.148-156
    • /
    • 2009
  • Background: As cardiovascular operations become more complex and sophisticated, there is an increasing need for various bioprostheses for use as components of blood vessels and heart valves. We developed a fatigue stimuli test instrument to objectively evaluate the mechanical durability of a bioprosthesis, and we tested several currently known processing methods for bovine pericardium and we then compared the results. Material and Method: Fresh bovine pericardium was collected at the butcher shop with using aseptic technique, and each piece of pericardium was fixated and/or decellularized by 16 representative methods. We measured the permeability and compliance of the processed bovine pericardium samples, and measured them again after exposure to the fatigue stimuli. All the pieces of pericardium underwent microscopic examinations before and after the fatigue stimuli. Result: A mixture of glutaraldehyde and solvent treatment showed better mechanical durability than did the single glutaraldehyde treatment. High concentration glutaraldehyde treatment showed equal or no worse results than did low concentration glutaraldehyde treatment. After SDS (sodium dodecylsulfate) decellularization, the mechanical property of the bioprosthesis became much worse ($20{\sim}190$ times) and the mechanical durability to the fatigue stimuli was also very poor. Conclusion: We obtained the basic durability data after various fixation methods with using a home-made fatigue test instrument.

The Effects of Aroma Self Massage in Hands on Pain, Depressive Mood and Anxiety in Breast Cancer Patients (유방암 환자의 통증, 우울 및 불안 증상 조절에 아로마 자가 치료의 효과)

  • Sohn, Keun-Joo;Kim, Myung-Ja;Lee, June-Young;Lee, Jae-Bok;Kim, Su-Hyun;Kim, Jong-A;Jung, Hoe-Hyun;Choi, Seung-Wan;Choi, Youn-Seon
    • Journal of Hospice and Palliative Care
    • /
    • v.8 no.1
    • /
    • pp.18-29
    • /
    • 2005
  • Purpose: Aroma therapy is one modality of alternative medicine. It was well known to have an analgesic, antidepressive and anxiolytic effects. This study is designed to investigate the effect of aroma self hand massage on vital signs, pain, depression, anxiety and stress in breast cancer patients. Methods: 32 female patient over 20 years old were divided into two groups by a non-blinded randomized controlled method. Patient in the aroma group (n=15) massaged their hands twice a day using aroma oil by themselves in their home for 2 weeks. However, those in control group (n=17) had not received my intervention during the study periods. Pain intensity, state anxiety, depression and stress of subjects were evaluated three times (0, 1, 3 weeks) using Visual Analogue Scale (VAS, $0{\sim}10cm$), State Trait Anxiety Inventory (STAI), Beck Depression Inventory Scales (BDIS), Brief Encounter Psychosocial Instrument (BEPSI revised edition). Also the change of patients' accompanying symptoms after aroma massage were analyzed using a structured questionnaire. Results: Pain Intensity decreased in the aroma group compared with control group (VAS changes $-0.83{\pm}1.01\;vs\;0.38{\pm}0.86$, P=0.005). The numbers of accompanying symptoms (P=0.044), depression score (P=0.001) and anxiety score (P=0.008) were significantly decreased in the aroma group, while in control group they increased after 2 weeks. However, the stress score showed no significant changes in both groups ($0.05{\pm}0.85\;vs\;0.04{\pm}0.20$, P=0.1519). The depression, anxiety and stress score showed negative correlation with compliance of aroma massage, but statistically no significant. The systolic blood pressure was a little increased in aroma group ($4.53{\pm}14.43\;vs\;0.0{\pm}7.22$, P=0.026), but was not significant clinically. Patients in the aroma group complained of several symptoms such as headache (20%), paresthesia (6.75%) and nausea (6.7%). However, there were no drop-out patients for those side effects. Conclusion: Aroma self massage during two weeks in breast cancer patients alleviates the pain intensity, depression and anxiety significantly.

  • PDF

Anticoagulation Management after Mitral Valve Replacement with the St. Jude Medical Prosthesis (승모판치환 환자의 항응혈제 치료)

  • 김종환;김영태
    • Journal of Chest Surgery
    • /
    • v.31 no.12
    • /
    • pp.1172-1182
    • /
    • 1998
  • Background: Primary goal of anticoagulation treatment in patients with mechanical heart valve is the effective prevention of thromboembolism and safe avoidance of bleeding as well. Material and Method: Two-hundred and nine patients with the St. Jude Medical prosthesis operated on between 1984 and 1995, for mitral(MVR 122), aortic(AVR 39) and double mitral and aortic valve replacement(DVR 48) respectively, were studied on the practically achieved levels of anticoagulation and the clinical outcomes. Patients were on Coumadin and followed up by monthly visit to outpatient clinic for examination and prothrombin time measurement to adjust the International Normalized Ratios(INRs) within the low-intensity target range between 1.5 and 2.5. Result: A total anticoagulation follow-up period was 1082.0 patient- years(mean 62.1 months) and INRs of 10,205 measurements were available for evaluation. The accomplished INRs among the replacement groups were not significantly different and only 65% of INRs were within the target range. And, in individual patients, only 37% of patients had INRs included within the target range in more than 70% of tests during follow-up period. The levels of INRs in patients with atrial fibrillation, which was found in 57% of patients, were definitely higher than the ones measured in patients with regular rhythm(p<0.001). Thromboembolisms were experienced by 15 patients with the incidence of 1.265%/patient- year(MVR 1.412%, AVR 0.462% and DVR 1.531%/patient-year) and major bleeding by 4 patients with the incidence of 0.337%/patient-year(MVR 0.424%, AVR none and DVR 0.383%/patient-year). Frequent as well as prolonged missing of prothrombin time tests was the main risk factor strongly associated with the thromboembolic complications(odds ratio 1.99). The proportion of INRs within target range of less than 60% in individual patient was the highly significant risk factor of both thromboembolic and overall embolic and bleeding complications(p<0.004 and p<0.002 respectively). Conclusion: In conclusion, the low-intensity therapeutic target range of INRs was adequate in patients with AVR and in sinus rhythm. However, the patients with replacement of the mitral valve were more likely to require higher target range of INRs, especially in the presence of atrial fibrillation, to achieve the practical levels of anticoagulation enough to prevent thromboembolic complications effectively. For the higher therapeutic target range of INRs between 2.0∼3.0, further accumulation of clinical evidences are required. It is highly desirable to improve the patients' compliance under continuous instructions in visiting outpatient clinic and in taking daily Coumadin without omission and to keep INRs consistently within optimal range with tight control for minimization of chances and of periods of exposure to the risk of complications. And, particularly, patients with high risk of complications and with wide fluctuation of INRs should be better managed with frequent monitoring anticoagulation levels.

  • PDF

Recovery of Pulmonary Function according to the Operative Sites after General Anesthesia (전신마취를 이용한 수술에서 수술부위에 따른 폐기능의 회복)

  • Kim, Hyeon-Tae;Lee, Sang-Moo;Uh, Soo-Taek;Chung, Yeon-Tae;Kim, Yong-Hoon;Park, Choon-Sik
    • Tuberculosis and Respiratory Diseases
    • /
    • v.40 no.3
    • /
    • pp.250-258
    • /
    • 1993
  • Background: After general anesthesia, decrease of functional residual capacity and lung compliance, ventilation/perfusion imbalance, and transpulmonary shunting can provoke hypoxemia during postoperative periods. Diaphragmatic dysfunction may be the main cause of these physiological abnormalities. Thus, we evaluated the change of pulmonary function after general anesthesia according to the operative sites, which could suggest clinical course and critical period of respiratory care of postoperative patients. Method: Preoperative portable spirometric evaluation and arterial blood gas analysis were performed at sitting or most-sitting position just previous day of surgery. Pulmonary function tests were also as same condition from postoperative day 1 to day 5. Results: 1) For thoracic surgery, FEV1 and FVC were not recovered at day 5, but FEV1/FVC was not decreased. $PaCO_2$ was slightly elevated at postoperative one day. 2) After upper abdominal surgery, postoperative day 5 did not show the recovery of FEV1 and FVC, but mild hypoxemia was developed at postoperative day 1. 3) Pulmonary function was recovered as preoperative value at postoperative day 5 in lower abdominal operation, but mild hypoxemia was also noted at postoperative day 1. 4) Surgery of peripheral areas did not show significant pulmonary function change and hypoxemia and hypercapnia from postoperative day 1. Conclusion: Surgery involving diaphragm provoke significant postoperative pulmonary function change after day 5. For the operation of peripheral sites adequate respiratory care during operation and postoperative period within 24 hours could prevent patients from respiratory complication.

  • PDF

Minimization of Small Bowel Volume within Treatment Fields Using Customized Small Bowel Displacement System(SBDS) (골반부 방사선 조사야 내의 소장 용적을 줄이기 위한 Small Bowel Displacement System(SBDS)의 사용)

  • Lim Do Hoon;Huh Seung Jae;Ahn Yong Chan;Kim Dae Yong;Wu Hong Gyun;Kim Moon Kyung;Choi Dong Rak;Shin Kyung Hwan
    • Radiation Oncology Journal
    • /
    • v.15 no.3
    • /
    • pp.263-268
    • /
    • 1997
  • Purpose : Authors designed a customized Small Bowel Displacement System (SBDS) to displace the small bowel from the Pelvic radiation fields and minimize treatment-related bowel morbidities. Materials and Methods : From August 1995 to Mar 1996. 55 consecutive patients who received pelvic radiation therapy with the SBDS were included in this study. The SBDS consists of a customized styrofoam compression device which can displace the small bowel from the radiation fields and an individualized immobilization abdominal board for easy daily setup in prone position After opacifying the small bowel with Barium3, the patients were laid Prone and posterior-anterior (PA) and lateral (LAT) simulation films were taken with and without the SBDS. The areas of the small bowel included in the radiation fields with and without the SBDS were compared. Results : Using the SBDS, the mean small bowel area was reduced by $59\%;on\;PA\;and\;51\%$ on LAT films (P=0.0001). In six Patients (6/55. $11\%$), it was Possible that no small bowel was included within the treatment fields. The mean upward displacement of the most caudal small bowel was 4.8 cm using the SBDS. Only $15\%$ (8/55) of patients treated with the SBDS manifested diarrhea requiring medication. Conclusion : The SBDS is a novel method that can be used to displace the small bowel away from the treatment portal effectively and reduce the radiation therapy morbidities. Compliance with setup is excellent when the SBDS is used.

  • PDF

Can Peritoneal Dialysis Remove Endothelin-1 after Cardiopulmonary Bypass for Repair of Congenital Heart Disease? (체외순환을 이용한 선천성 심장수술 후에 시행한 복막투석이 내피의존성 혈관 활성 물질인 Endothelin-1을 제거할 수 있는가?)

  • Chang, Yun-Hee;Ban, Ji-Eun;Lee, Hyoung-Doo;Lee, Sun-Hee;Rhym, Byuong-Yong;Sung, Si-Chan
    • Journal of Chest Surgery
    • /
    • v.40 no.4 s.273
    • /
    • pp.247-255
    • /
    • 2007
  • Background: Lung injury that follows bypass has been well described. It is manifested as reduced oxygenation and lung compliance and, most importantly, increased pulmonary vascular resistance reactivity; this is a known cause of morbidity and mortality after repair of congenital heart disease. Injury to the pulmonary vascular endothelium, and its associated alterations of endothelin-1, is considered to be a major factor of bypass-induced lung injury. Removing endothelin-1 after bypass may attenuate this response. This study measured the concentration of serum and peritoneal effluent endothelin-1 after performing bypass to determine if endothelin-1 can be removed via peritoneal dialysis. Material and Method: From March 2005 to March 2006, 18 patients were enrolled in this study Peritoneal catheters were placed at the end of surgery. Serum samples were obtained before and after bypass, and peritoneal effluents were obtained after bypass. Endothelin-1 was measured by enzyme linked immunosorbent assay (ELISA). Result: In the patients with a severe increase of the pulmonary artery pressure or flow, the mean preoperative plasma endothelin-1 concentration was significantly higher than that in the patients who were without an increase of their pulmonary artery pressure or flow (4.2 vs 1.8 pg/mL, respectively, p<0.001). The mean concentration of plasma endothelin-1 increased from a preoperative value of $3.61{\pm}2.17\;to\;5.33{\pm}3.72 pg/ml$ immediately after bypass. After peritoneal dialysis, the mean plasma endothelin-1 concentration started to decrease. Its concentration at 18 hours after bypass was significantly lower than the value obtained immediately after bypass (p=0.036). Conclusion: Our data showed that the plasma endothelin-1 concentration became persistently decreased after starting peritoneal dialysis, and this suggests that peritoneal dialysis can remove the circulating plasma endothelin-1.

The immunogenicity and reactogenicity of Td booster vaccination in Korean preadolescents, aged with 11-12 years old (국내 11-12세 소아에서 Td 백신 추가접종의 면역원성과 안전성 평가)

  • Lee, Soo Young;Kwak, Ga Young;Mok, Hye Rin;Kim, Jong Hyun;Hur, Jae Kyun;Lee, Kyung Il;Park, Joon Su;Ma, Sang Hyuk;Kim, Hwang Min;Kang, Jin Han
    • Clinical and Experimental Pediatrics
    • /
    • v.51 no.11
    • /
    • pp.1185-1190
    • /
    • 2008
  • Purpose : This study was undertaken to evaluate the immunogenicity and reactogenicity of Td booster immunization in early preadolescents of Korea. Methods : Healthy preadolescents, who had been vaccinated with 4 or 5 doses of DTaP vaccines until 6 years old age, were enrolled in this study from August 2006 to April 2007. Diphtheria and tetanus anti-toxoid antibodies in sera were measured by ELISA just before vaccination and 4 weeks after vaccination to evaluate immunogenicity. Local and systemic adverse reactions observed for 4 weeks after vaccination to access reactogenicity. Results : 183 preadolescents were enrolled and mean age was $11.40{\pm}0.51$ years old. All subjects achieved seroprotective diphtheria and tetanus anti-toxoid antibodies (titers ${\geq}0.1IU/mL$) after Td booster vaccination. Among 183 vaccinees, 73.8% showed local adverse reactions and 37.2% systemic adverse reactions. Pain at injection site (66.1%) was the most common local reaction, and the most commonly shown systemic reaction was myalgia (17.5%). The adverse reactions were spontaneously relieved within three days after vaccination. Conclusion : Td vaccine in this study was high immunogenic and showed an acceptable tolerance in Korean preadolescents. Td booster vaccination at 11-12 years old is the most effective method to increase compliance of the vaccination and to decrease the incidence of diphtheria and tetanus.

Activation Analysis of Dual-purpose Metal Cask After the End of Design Lifetime for Decommission (설계수명 이후 해체를 위한 금속 겸용용기의 방사화 특성 평가)

  • Kim, Tae-Man;Ku, Ji-Young;Dho, Ho-Seog;Cho, Chun-Hyung;Ko, Jae-Hun
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.14 no.4
    • /
    • pp.343-356
    • /
    • 2016
  • The Korea Radioactive Waste Agency (KORAD) has developed a dual-purpose metal cask for the dry storage of spent nuclear fuel that has been generated by domestic light-water reactors. The metal cask was designed in compliance with international and domestic technology standards, and safety was the most important consideration in developing the design. It was designed to maintain its integrity for 50 years in terms of major safety factors. The metal cask ensures the minimization of waste generated by maintenance activities during the storage period as well as the safe management of the waste. An activation evaluation of the main body, which includes internal and external components of metal casks whose design lifetime has expired, provides quantitative data on their radioactive inventory. The radioactive inventory of the main body and the components of the metal cask were calculated by applying the MCNP5 ORIGEN-2 evaluation system and by considering each component's chemical composition, neutron flux distribution, and reaction rate, as well as the duration of neutron irradiation during the storage period. The evaluation results revealed that 10 years after the end of the cask's design life, $^{60}Co$ had greater radioactivity than other nuclides among the metal materials. In the case of the neutron shield, nuclides that emit high-energy gamma rays such as $^{28}Al$ and $^{24}Na$ had greater radioactivity immediately after the design lifetime. However, their radioactivity level became negligible after six months due to their short half-life. The surface exposure dose rates of the canister and the main body of the metal cask from which the spent nuclear fuel had been removed with expiration of the design lifetime were determined to be at very low levels, and the radiation exposure doses to which radiation workers were subjected during the decommissioning process appeared to be at insignificant levels. The evaluations of this study strongly suggest that the nuclide inventory of a spent nuclear fuel metal cask can be utilized as basic data when decommissioning of a metal cask is planned, for example, for the development of a decommissioning plan, the determination of a decommissioning method, the estimation of radiation exposure to workers engaged in decommissioning operations, the management/reuse of radioactive wastes, etc.