• Title/Summary/Keyword: Compliance Device

Search Result 109, Processing Time 0.032 seconds

Non-linear Resistive Switching Characteristic of ZnSe Selector Based HfO2 ReRAM Device for Eliminating Sneak Current

  • Kim, Jong-Gi;Kim, Yeong-Jae;Mok, In-Su;Lee, Gyu-Min;Son, Hyeon-Cheol
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.357-358
    • /
    • 2013
  • The non-linear characteristics of ON states are important for the application to the high density cross-point memory industry because the sneak current in neighbor cells occurred during reading, erasing, and writing process. Kw of above 20 in ON states, which is the writing current @ Vwrite/the current @ 1/2Vwrite, was required in cross-point ReRAM memory industry. The high current density non-linear IV curve of ZnSe selector was shown and the ALD HfO2 switching device has the linear properties of ON states and the compliance current of 100 uA. To evaluate the performance of the selection device, we connected itto HfO2 switching device in series. The bottom electrode of the selection device was connected to the top electrode of the RRAM. All of the bias was applied with respect to the top electrode of the selection device, whereas the bottom electrode of the RRAM was grounded. In the cross-point application, 1/2Vwrite and -1/2Vwrite were applied to the word-line and bit-line, respectively, which were connected to the selected cell, and a zero bias was applied to the unselected word-lines and bit-lines. The current @ 1/2Vwrite of the unselected cells was blocked by the selection device, thus eliminating the sneak path and obtaining a writing voltage margin. Using this method, the writing voltage margin was analyzed on the basis of the memory size.

  • PDF

Non-Intrusive Healthcare System for Estimation of Vascular Condition in IP-Enabled Wireless Network (IP 기반 무선네트워크에서의 혈관상태 평가를 위한 무구속 헬스케어 시스템)

  • Jung, Sang-Joong;Kwon, Tae-Ha;Chung, Wan-Young
    • Journal of Sensor Science and Technology
    • /
    • v.22 no.1
    • /
    • pp.76-83
    • /
    • 2013
  • A real-time wireless monitoring and analysis methods using the wearable PPG sensor to estimate cardiovascular condition is studied for ubiquitous healthcare service. A small size and low-power consuming wearable photoplethysmogram (PPG) sensor is designed as a wrist type device and connected with the IP node assigned its own IPv6 address. The measured PPG waveform in the IP node is collected and transferred to a central server PC through the IP-enabled wireless network for storage and analysis purposes. A monitoring and analysis program is designed to process the accelerated plethysmogram (APG) waveform by applying the second order derivatives to analyze systolic waves as well as heart rate variability analysis from the measured PPG waveform. From our results, the features of cardiovascular condition from individual's PPG waveform and estimation of vascular compliance by the comparison of APG-aging index (AI) and ratio of LF/HF are demonstrated.

Emulation of Tri-Phasic Pulsatile Flow Using LVAD (좌심실 보조기를 이용한 3상형 박동류 모의)

  • 이동혁;김종효
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.3
    • /
    • pp.313-320
    • /
    • 1998
  • Tri-phasic pulsatile flow is the general flow pattern of human circulary system. In emulating the various situation of cardiovascular system, it is essential to make tri-phasic source flow. To emulate tri-phasic pulsatile flow, we used electro-hydronic style LVAD(Left Ventricular Assist Device) with glass phantom and rubber tube. We have selected control parameters and examined the changing effect of each parameter by using Doppler ultrasound. In this experiment, it was shown that the distal compliance and the break time were the major factors to form tri-phasic flow. The results make it possible to emulate and explain the various situation of human vascular system. In this point, this results will be an useful method in the clinic application.

  • PDF

Measuring and Analyzing WiMAX Security adopt to Wireless Environment of U-Healthcare (유헬스케어의 무선환경에 적합한 WiMAX 보안 측정 및 분석)

  • Jeong, Yoon-Su
    • Journal of Digital Convergence
    • /
    • v.11 no.3
    • /
    • pp.279-284
    • /
    • 2013
  • Wireless access network section needs strong security which supports high data rate and mobility not to invade patient's privacy by exposing patient's sensitive biometric from automatic implantable device that is adapted to u-healthcare service. This paper builds test bed and performs assessment and measurement of security ability of WiMAX network to transmit and receive mobile patient's biometric by building WiMAX network in wireless access network not to expose paitne's biometirc at wireless access network section to the third person. Specially, this paper compares and assesses data security, MAC control message security, handover conection delay, and frame loss and bandwidth of ECDH at the layer of WiMAX security compliance, WiMAX MAC IPSec, and MAC.

Application of Ecological Momentary Assessment in Studies with Rotation Workers in the Resources and Related Construction Sectors: A Systematic Review

  • Bernard Yeboah-Asiamah Asare;Suzanne Robinson;Dominika Kwasnicka;Daniel Powell
    • Safety and Health at Work
    • /
    • v.14 no.1
    • /
    • pp.10-16
    • /
    • 2023
  • Whilst Ecological momentary assessment (EMA) can provide important insights over time and across contexts among rotation workers whose work periods alternate with leave at home, it can also be challenging to implement in the resources and construction sectors. This review aimed to provide a summary of the methodological characteristics of EMA studies assessing health outcomes and related behaviors in rotation workers. Systematic searches in PubMed, Medline, EMBASE, CINAHL, PsycINFO, and Scopus were done to include 23 studies using EMA methods in assessing health-related outcomes and behaviors. EMA designs included daily diary: assessments once per day typically fixed at the end of day (47.8%), within day fixed interval time-based design: assessments on multiple times per day at certain times of day (17.4%) and combination of both designs (34.8%). Studies employed paper and pencil diaries (73.9%) and one or more electronic methods (60.9%): wrist-worn actigraphy device (52.2%) and online-based diaries (26.1%) for data collection. Most of the studies (91.3%) did not report prompting -EMAs by schedule alerts or compliance. Daily diary and within day fixed interval dairies designs are common, with the increasing use of electronic EMA delivery techniques. It is unclear how well participants adhere to assessment schedules, as these are inadequately reported. Researchers should report compliance-related information.

Evaluation of On-Road NOx Emission from a Light Duty Diesel Vehicle using a Portable Emissions Measurement System (이동식 배출가스 측정장비를 이용한 소형 경유 자동차의 실도로 질소산화물 배출특성 분석)

  • Lee, Tae-Woo;Lee, Jong-Tae;Kim, Jeong-Soo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.28 no.1
    • /
    • pp.94-104
    • /
    • 2012
  • The purpose of this research is to quantify the compliance of on-road emission from a light duty diesel vehicle, based on a comparison to emission regulation standard. $NO_x$, CO and THC emissions were measured using a portable device on a selected real-world driving route with a length of approximately 22 km. On-road measurements were repeated by 10 times on a same route to reflect variability in traffic conditions. A test route was divided into 22 road links with length of 1 km to analyze emission results with higher spatial resolution. The average emissions of $NO_x$, CO and THC over total travel distance, which is approximately 220 km, were quantified to be in compliance with emission regulation standards. Under higher spatial resolution, $NO_x$ concentration exceeded a standard in 92 links out of 220 links. The extended time in stop period and the stop-and-go driving cycle were identified as two important reasons for increased $NO_x$ emissions in observed cases. Heavy traffics showed higher $NO_x$ emissions than free flow. These results indicate that the real-world vehicle emissions might exceed the compliance level associate with traffic conditions. Another interesting observation of this research is that the on-road emission characteristics can be independent to the average speed of road links with higher spatial resolution. Variability in on-road emission might not be fully described by solely relying on an average speed, because variability in traffic conditions and road conditions can influence on real-world vehicle emissions.

Compliance of Nasal Continuous Positive Airway Pressure in Patients with Obstructive Sleep Apnea Syndrome (폐쇄성 수면무호흡증 환자의 지속적 상기도 양압술 순응도)

  • Choi, Jong-Bae;Lee, Seung-Hee;Jeong, Do-Un
    • Sleep Medicine and Psychophysiology
    • /
    • v.13 no.1
    • /
    • pp.27-32
    • /
    • 2006
  • Objectives: Nasal continuous positive airway pressure (nCPAP) is the treatment of choice and has been shown to reduce the frequency of nocturnal respiratory events, improve sleep architecture, and decrease daytime sleepiness in patients with obstructive sleep apnea syndrome (OSAS). However, little is known about the compliance of nCPAP treatment in Korea. Our objective was to look into the nCPAP compliance and examine the factors influencing it. Methods: We reviewed the records of one hundred and twenty consecutive patients with OSAS referred for nocturnal polysomnography with nCPAP pressure titration during the period of January 1995 through April 1999 to the Seoul National University Hospital. We performed a telephone interview and obtained data from eighty-three patients. Results: In sixty patients who had accepted nCPAP treatment, twenty-six patients (43.3%) were still using nCPAP device, while thirty-four patients (56.7%) stopped using it. Fifteen patients (25%) were using nCPAP device everyday. In thirty-four patients who discontinued nCPAP use, twenty-five patients (73.5%) did within the first three months, and thirty-one (91.2%) within the first year. Significant predictor of long-term nCPAP use was the presence of subjective daytime sleepiness before nCPAP application. Conclusions: Long-term compliance with nCPAP treatment appears to be associated with the presence of subjective daytime sleepiness before nCPAP application. Long-term compliance with nCPAP may be mostly predicted from the usage pattern within the first three months of use.

  • PDF

A Study on the Efficacy and Compliance of Oral Appliances according to the Severity of Apnea in the Treatment of Snoring and Obstructive Sleep Apnea (코골이와 폐쇄성수면무호흡증 환자에서 무호흡 심도에 따른 구강내 장치의 치료효과 및 환자의 적응도에 관한 연구)

  • 안홍균;이광호;정성창
    • Journal of Oral Medicine and Pain
    • /
    • v.23 no.4
    • /
    • pp.419-432
    • /
    • 1998
  • The purpose of this Study was to examine the efficacy and compliance of a mandibular advancement device(MAD) according to the severity of sleep apnea in the snorers and obstructive sleep apnea patients. Fifty-four patients (45 males, 9 females, aged 20 - 68years ) who visited Seoul National Uiversity Dental Hospital(SNUDH) to seek for the treatment of snoring and sleep apnea were classified into four groups according to the results of the nocturnal polysomnography and they were instructed to wear MAD regularly which was designed to increase the size of the upper airway by advancing the mandible. The evaluation of the efficacy and compliance of the MAD according to the severity of apnea and the duration after the usage of MAD ( 1week, 1month, 3months, 6months, 12months) was made by using quesionnaires mad in Department of Oral Medicine and Oral diagnosis, SNUDH. The obtained results were as follows : 1. All subjects results were habitual snoreres and 43 patients(79.6%) complained the loudness of snoring that can be heard out of the room. 2. Apnea index(AI) of the total subjects was mean 29.4$\pm$26.9 and respiratory disturbance index(RDI)was mean 37.6$\pm$28.0. And there was nodifference in the efficacy and the compliances of MAD according to the severity of apnea. 3. The severityi of apnea by the questionnaires significantly corresponded with the results of nocturnal polysomnography, and this fact potentiated the diagnostic value of the questionnaire. 4. after the usage of MAD, there was significant improvement in the frequency of snoring, the loudness of snoring, frequency of apnea, daytime sleepiness nad the refreshment after sleep(p<0.001) regardless of the apnea index(AI) and respiratory distrubance index(RDI). 5. The degree of the satisfaction with MAD was mean 74.4$\pm$18.4% and that of the discomfort with the MAD was 31.4$\pm$19.6%. But there was no serious complication in occlusion and temporomandibular joint with the usage of MAD and the duration of the discomfort was mean 3.3$\pm$2.2 weeks. 6. Forty-one patients(75.9%) continued the usage of MAD but thirteen patients(24.1%) stopped the use of MAD because of the discomforts and insufficient results with it.

  • PDF

Energy Efficient Wireless Data Transmission for Personal Health Devices

  • Kim, Sang-Kon;Kim, Tae-Kon;Koh, Jin-Hwan
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.6
    • /
    • pp.1559-1570
    • /
    • 2013
  • The family of ISO/IEEE11073 standards is the basis of the e-health system and provides interoperability for personal health devices. In the early stage of e-health business, it was expected that people would use a health device individually. In this case, a measurement datum was episodically acquired and generally transmitted for one person at a time. Recently, a health device is expected to be used by multiple people, and large amounts of measurement data are gathered in a short time interval. In addition, mobile health devices have become more popular, so that energy efficient measurement data transmission is required, to prolong the use of a device. In IEEE11073 PHD standards, data transmission is classified into three different types: immediate individual transfer, small block transfer, and large block transfer. The large block transfer using PM-store concept provides efficient transmission. However, an existing PM-store has problem when a device is used by multiple people. To address the defined problem, a modified PM-segment that is in compliance with 11073 standards is proposed in this paper. In particular, the proposed PM-segment is designed to minimize the additional complexity of an agent instead of a manager and it is interoperable with the existing manager. The proposed PM-segment shows better performance than the existing PM-segment, in terms of memory requirements and expected queue time. Also, performance comparison among the three transfers is performed in regard to the delay time and communication power consumption points of view.

Effect of Non-lattice Oxygen Concentration on Non-linear Interfacial Resistive Switching Characteristic in Ultra-thin HfO2 Films

  • Kim, Yeong-Jae;Kim, Jong-Gi;Mok, In-Su;Lee, Gyu-Min;Son, Hyeon-Cheol
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.359-360
    • /
    • 2013
  • The effect of electrode and deposition methods on non-linear interfacial resistive switching in HfO2 based $250{\times}250$ nm2 cross-point device was studied. HfO2 based device has the interfacial resistive switching properties of non-linearity and self-compliance current switching. The operating current in HfO2 based device was increased with negatively increasing the heat of formation energy in top electrode. Also, it was investigated that the operating current in HfO2 based device was changed with deposition methods of O3 reactant ALD, H2O reactant ALD and dc reactive sputtering, resulting the magnitude of the operating current and on/off ratio in order of HfO2 films deposited by dc reactive sputtering, H2O reactant ALD, and O3 reactant ALD. To investigate the effect of electrode and deposition methods on operating current of non-linear interfacial resistive switching in the cross-point device, X-ray photoelectron spectroscopy was measured. Through the analysis of O 1s spectra, non-lattice oxygen concentration, which is closely related to oxygen vacancies, was increased in order of Pt, TiN, and Ti top electrodes and in order of O3 reactant ALD, H2O reactant ALD, and O3 reactant ALD, and dc reactive sputtering deposition method. From all results, non-lattice oxygen concentration in ultra-thin HfO2 films play a crucial role in the operating current and memory states (LRS & HRS) in the non-linear interfacial resistive switching.

  • PDF