• 제목/요약/키워드: Complete prosthesis

검색결과 108건 처리시간 0.03초

Standardized multi-institutional data analysis of fixed and removable prosthesis: estimation of life expectancy with regards to variable risk factors

  • Hae-In Jeon;Joon-Ho Yoon;Jeong Hoon Kim;Dong-Wook Kim;Namsik Oh;Young-Bum Park
    • The Journal of Advanced Prosthodontics
    • /
    • 제16권2호
    • /
    • pp.67-76
    • /
    • 2024
  • PURPOSE. This study aims to assess and predict lifespan of dental prostheses using newly developed Korean Association of Prosthodontics (KAP) criteria through a large-scale, multi-institutional survey. MATERIALS AND METHODS. Survey was conducted including 16 institutions. Cox proportional hazards model and principal component analysis (PCA) were used to find out relevant factors and predict life expectancy. RESULTS. 1,703 fixed and 815 removable prostheses data were collected and evaluated. Statistically significant factors in fixed prosthesis failure were plaque index and material type, with a median survival of 10 to 18 years and 14 to 20 years each. In removable prosthesis, factors were national health insurance coverage, antagonist type, and prosthesis type (complete or partial denture), with median survival of 10 to 13 years, 11 to 14 years, and 10 to 15 years each. For still-usable prostheses, PCA analysis predicted an additional 3 years in fixed and 4.8 years in removable prosthesis. CONCLUSION. Life expectancy of a prosthesis differed significantly by factors mostly controllable either by dentist or a patient. Overall life expectancy was shown to be longer than previous research.

Effect of polymerization method and fabrication method on occlusal vertical dimension and occlusal contacts of complete-arch prosthesis

  • Lima, Ana Paula Barbosa;Vitti, Rafael Pino;Amaral, Marina;Neves, Ana Christina Claro;Concilio, Lais Regiane da Silva
    • The Journal of Advanced Prosthodontics
    • /
    • 제10권2호
    • /
    • pp.122-127
    • /
    • 2018
  • PURPOSE. This study evaluated the dimensional stability of a complete-arch prosthesis processed by conventional method in water bath or microwave energy and polymerized by two different curing cycles. MATERIALS AND METHODS. Forty maxillary complete-arch prostheses were randomly divided into four groups (n = 10): MW1 - acrylic resin cured by one microwave cycle; MW2 - acrylic resin cured by two microwave cycles: WB1 - conventional acrylic resin polymerized using one curing cycle in a water bath; WB2 - conventional acrylic resin polymerized using two curing cycles in a water bath. For evaluation of dimensional stability, occlusal vertical dimension (OVD) and area of contact points were measured in two different measurement times: before and after the polymerization method. A digital caliper was used for OVD measurement. Occlusal contact registration strips were used between maxillary and mandibular dentures to measure the contact points. The images were measured using the software IpWin32, and the differences before and after the polymerization methods were calculated. The data were statistically analyzed using the one-way ANOVA and Tukey test (${\alpha}=.05$). RESULTS. The results demonstrated significant statistical differences for OVD between different measurement times for all groups. MW1 presented the highest OVD values, while WB2 had the lowest OVD values (P<.05). No statistical differences were found for area of contact points among the groups (P=.7150). CONCLUSION. The conventional acrylic resin polymerized using two curing cycles in a water bath led to less difference in OVD of complete-arch prosthesis.

Effect of cement washout on loosening of abutment screws and vice versa in screw- and cement- retained implant-supported dental prosthesis

  • Kim, Seok-Gyu;Chung, Chae-Heon;Son, Mee-Kyoung
    • The Journal of Advanced Prosthodontics
    • /
    • 제7권3호
    • /
    • pp.207-213
    • /
    • 2015
  • PURPOSE. The purpose of this study was to examine the abutment screw stability of screw- and cement-retained implant-supported dental prosthesis (SCP) after simulated cement washout as well as the stability of SCP cements after complete loosening of abutment screws. MATERIALS AND METHODS. Thirty-six titanium CAD/CAM-made implant prostheses were fabricated on two implants placed in the resin models. Each prosthesis is a two-unit SCP: one screw-retained and the other cemented. After evaluating the passive fit of each prosthesis, all implant prostheses were randomly divided into 3 groups: screwed and cemented SCP (Control), screwed and non-cemented SCP (Group 1), unscrewed and cemented SCP (Group 2). Each prosthesis in Control and Group 1 was screwed and/or cemented, and the preloading reverse torque value (RTV) was evaluated. SCP in Group 2 was screwed and cemented, and then unscrewed (RTV=0) after the cement was set. After cyclic loading was applied, the postloading RTV was measured. RTV loss and decementation ratios were calculated for statistical analysis. RESULTS. There was no significant difference in RTV loss ratio between Control and Group 1 (P=.16). No decemented prosthesis was found among Control and Group 2. CONCLUSION. Within the limits of this in vitro study, the stabilities of SCP abutment screws and cement were not significantly changed after simulated cement washout or screw loosening.

노인환자의 구강상태, 치료요구도와 만족도 (ORAL STATUS OF GERIATRIC PATIENTS, AND THEIR DEMAND AND SATISFACTION IN PROSTHODONTIC TREATMENT)

  • 정문규;이철영;장혁진
    • 대한치과보철학회지
    • /
    • 제39권4호
    • /
    • pp.323-335
    • /
    • 2001
  • In this study 240 geriatric patients, aged 60 year and over were evaluated using a questionnaire and oral examination for their oral status, demand and satisfaction of prosthodontic treatment. The followings are the findings : 1. The single main complaint was regarding from the existing removable prosthesis, When the complaints were categorized into larger groups, complaints regarding existing prosthesis were 32% and followed by 30% in caries and endodontic problems. 2. Approximately half of the geriatric patients had 21 or more remaining dentition. This number however diminished with increase in age of the surveyed patient. 3. According to the result from questionnaire, 48% of patients wearing removable prosthesis and 43% with fixed prosthesis were not satisfied with existing prosthesis. Thirty-seven percentages of patients were not satisfied with aesthetics and unable to chew food properly. 4. Seventy-seven percentages of patients requested for new prosthesis and the majority of these patients had complaints of difficulties in chewing and discomfort. 5. Thirty-nine percentages of patients were wearing removable prosthesis. More complete dentures were found on maxilla and partial dentures on mandible.

  • PDF

하악 무치악 환자에서 임플란트 하이브리드형 보철물을 이용한 전악 수복 증례 (Full mouth rehabilitation of mandibular edentulous patient using implant hybrid prosthesis)

  • 김현숙;김소현;오남식
    • 대한치과보철학회지
    • /
    • 제56권1호
    • /
    • pp.25-30
    • /
    • 2018
  • 무치악 환자에서 임플란트 고정성 보철 수복의 장점은 안정성, 편안함을 들 수 있으며, 생물학적 측면으로는 하악골 흡수를 방지할 수 있고 저작기능이 향상된다는 이점이 있다. 그중 하이브리드형 보철 수복은 하악골 이공사이에 4 - 6개의 임플란트를 식립하고 양쪽 원심으로 캔틸레버를 만들어 구치부 치아를 대체하게 된다. 본 증례는 85세 여성 환자로 상하악의 무치악 상태로 본원에 내원하였다. 상악의 가철성 총의치, 하악의 임플란트 하이브리드형 보철물로 최종 치료하여 치료 후 기능적, 심미적으로 만족스러운 결과를 얻었기에 이를 보고하고자 한다.

Influence of gag reflex on removable prosthetic restoration tolerance according to the patient section of the short form of the Gagging Problem Assessment Questionnaire

  • Yildirim-Bicer, Arzu Zeynep;Akarslan, Zuhre Zafersoy
    • The Journal of Advanced Prosthodontics
    • /
    • 제6권6호
    • /
    • pp.474-482
    • /
    • 2014
  • PURPOSE. To assess removable prosthetic restoration tolerance according to the patient section of the short form of the Gagging Problem Assessment Questionnaire (GPA-pa SF) and the influence of gender, education level and prosthesis type and denture-related mucosal irritation on the GPA-pa SF scores before treatment and over a period of two months after prosthesis insertion. MATERIALS AND METHODS. 130 participants who required removable prosthesis were surveyed with a standard form that included questions regarding age, gender, education level, dental attendance, and prosthetic restoration type. Participants answered the GPA-pa SF before restoration (T0) and 1 day (T1), 2 days (T2), 15 days (T3), 1 month (T4), and 2 months (T5) after prosthesis insertion. RESULTS. Of the 130 participants, 110 participants completed the prosthetic restoration procedure, but only 93 of these were able to use the prosthesis over the two-month period. The mean GPA-pa SF score obtained at T0 was higher than the scores obtained at the other periods in the total of the sample. Significant difference was present between mean scores obtained at T0-T1 and T2-T3 than scores obtained at other periods (P<.05). Female participants and participants with denture-related mucosal irritation had higher GPA-pa SF scores at all time points analysed. Significant difference was present between mean GPA-pa SF scores obtained at T2-T3 than scores obtained at other periods for females and participants with denture-related mucosal irritation (P<.05). Education level and prosthesis type did not significantly influence the GPA-pa SF score at any time point analysed (P>.05). CONCLUSION. GPA-pa SF scores were higher before the restoration procedure began, and decreased over time with the use of prosthesis. Gender and denture-related mucosal irritation affected the GPA-pa SF scores.

항암치료 중인 환자에서 파절된 금속-도재관을 CAD/CAM으로 제작된 complete contour zirconia surveyed crown(완전한 윤곽을 가진 지르코니아 써베이드 전장관) 보철 수복: 증례 보고 (An alternative method to convert fractured metal ceramic surveyed crown into a complete contour zirconia surveyed crown using CAD-CAM technology under anticancer treatments: a clinical report)

  • 이선기;양홍서;박상원;윤귀덕;임현필
    • 구강회복응용과학지
    • /
    • 제31권1호
    • /
    • pp.45-49
    • /
    • 2015
  • 본 증례는 기존의 국소의치에서 파절된 metal-ceramic surveyed crown을 complete contour zirconia surveyed crown으로 전환하는 간단하고 편리한 CAD/CAM 기술을 보고하고 있다. 항암치료를 받고 있는 환자의 기존 metal-ceramic surveyed crown 외형, 형태학적 특성, 레스트 시트를 complete contour zirconia surveyed crown으로 제작하는 복제 기법에 대해 보고한다.

치과기공사국가시험 문항개발기준안연구 (Research for the Standard Model of the Items of the National Qualification Examination for the Dental Technician)

  • 이덕혜;정인성;한창식
    • 대한치과기공학회지
    • /
    • 제23권2호
    • /
    • pp.75-93
    • /
    • 2002
  • This research was preformed for the purpose of preparing the items of standard model of the national dental technician test base on the duty analysis of the dental technician. The results of the duty analysis for the dental technician follows. 1. The dental technician is a profession to make the oral function smooth through the dental supplement and equipment in a scientific method and the skilled technique. 2. The duty of the dental technician are determined as A. preparation for manufacture B. manufacture C. management of the place of the dental technology D. self-development. A. The field of "the preparation for manufacture" are determined as 1. to confirm work authorization 2. To confirm the working model, B. The field of "In manufacture" are determined as 1. to manufacture the temporary crown 2. to manufacture the inlay and crown & bridge prosthesis 3. to manufacture the porcelain fused metal crown prosthesis 4. to manufacture the all ceramic crown prosthesis 5. to manufacture the temporary denture prosthesis 6. to manufacture the partial denture prosthesis 7. to manufacture the complete denture prosthesis 8. to manufacture the attachment prosthesis 9. to manufacture implant prosthesis 10. to manufacture the removable orthodontic device, 11. to manufacture the fixed orthodontic device, 12. to manufacture the orthodontic study cast C. The field of "in management of the dental lab." are determined as 1. management 2. to control the dental lab. D. The field of "In the self-development" are determined as 1. to improve the professionalism 2. self-control. 3. The developing items selected under the duty evaluation of the dental technician are l7s in the manufacture preparation, 1,011s in the manufacture, 7s in the management for the dental technology, 5s in self-development, and in all together 1,040s

  • PDF

구치부 심미수복, 풀지르코니아 크라운의 파절원인과 그 해결방안 (Factors affecting fracture of full contour monolithic zirconia dental prosthesis in laboratory process)

  • 이수영
    • 대한심미치과학회지
    • /
    • 제23권2호
    • /
    • pp.77-79
    • /
    • 2014
  • There are several factors affected fractures of full contour zirconia (FCZ) dental prosthesis in laboratory process. First, residual moisture can cause zirconia cracks. Complete dry is requisite before zirconia sintering to prevent zirconia cracks. Second, slow cooling rate is essential to prevent cracks during zirconia sintering process. Cracks in bridge pontic area, thick dental implant prosthesis can be prevented by slow cooling rate such as 3 degree Celsius per minute during zirconia sintering. Third, slow heating rate and slow cooling rate during staining and glazing procedure is necessary to inhibit thermal shock of sintered dental zirconia. Lower preheat temperature of porcelain furnace is recommended. Finally, using diamond disc to open embrasure can lead cracks.

CarboMedies 기계판막의 임상적 연구 (Clinical Experience of Carbomedics Valve)

  • 김병열
    • Journal of Chest Surgery
    • /
    • 제27권12호
    • /
    • pp.995-1001
    • /
    • 1994
  • The CarboMedics valve prosthesis is a relatively new. low profile bileaflet prosthesis. During a 6 year period from Aug. 1988 to July 1994. 158 patients had CarboMedics prostheses implanted in the mitral [n=94], aortic [n=25], or aortic and mitral [n=39] in National Medical Center. Hospital mortality was 9.4% and the main cause of death was low output syndrome. Follow up was 96% complete, with 365.4 patient-years and a mean follow up of 30 months [ range 1 to 72 months ] . The overall actuarial 6 year survival rate was 91.61 3.47% and actuarial 6year freedom from all valve related complications was 73.9 7.67%. The linearized incidence of vavle related complications was as follows: thromboembolism 1.37%/patient-year ; valve thrombosis 0.82%/ patient-year ; anticoagulant related hemorrhage 0.85%/patient-year ; perivalvular leakage 0.55%/paitent-year: prosthetic valve endocarditis 0.82%/patient-year ; reoperation 1.37%/patient-year. There were no instances of structural failure. We conclude that the Carbomedics valve has a low rate of complications that further improves the quality of life in patients with heart valve prostheses.

  • PDF