• Title/Summary/Keyword: Compensation technique

Search Result 700, Processing Time 0.032 seconds

2.4 GHz WLAN InGaP/GaAs Power Amplifier with Temperature Compensation Technique

  • Yoon, Sang-Woong;Kim, Chang-Woo
    • ETRI Journal
    • /
    • v.31 no.5
    • /
    • pp.601-603
    • /
    • 2009
  • This letter presents a high performance 2.4 GHz two-stage power amplifier (PA) operating in the temperature range from $-30^{\circ}C$ to $+85^{\circ}C$ for IEEE 802.11g, wireless local area network application. It is implemented in InGaP/GaAs hetero-junction bipolar transistor technology and has a bias circuit employing a temperature compensation technique for error vector magnitude (EVM) performance. The technique uses a resistor made with a base layer of HBT. The design improves EVM performance in cold temperatures by increasing current. The implemented PA has a dynamic EVM of less than 4%, a gain of over 26 dB, and a current less than 130 mA below the output power of 19 dBm across the temperature range from $-30^{\circ}C$ to $+85^{\circ}C$.

Compensation of Power Fluctuations of PV Generation System by SMES Based on Interleaving Technique

  • Kim, Seung-Tak;Park, Jung-Wook
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.5
    • /
    • pp.1983-1988
    • /
    • 2015
  • This paper proposes the enhanced application of superconducting magnetic energy storage (SMES) for the effective compensation of power fluctuations based on the interleaving technique. With increases in demand for renewable energy based photovoltaic (PV) generation system, the output power fluctuations from PV generation system due to sudden changes in environmental conditions can cause serious problems such as grid voltage and frequency variations. To solve this problem, the SMES system is applied with its superior characteristics with respect to high power density, fast response for charge and discharge operations, system efficiency, etc. In particular, the compensation capability is effectively improved by the proposed interleaving technique based on its parallel structure. The dynamic performance of the system designed using the proposed method is evaluated with several case studies through time-domain simulations.

Temperature Compensation Technique for Steel Sleeve Packaged FBG Strain Sensor in Structural Monitoring (Steel Sleeve Packaged FBG 변형률센서를 이용한 구조물 모니터링에서의 온도보정 기술)

  • Jang, Il-Young;Yun, Ying-Wei;Ryu, Jeong-Su;Park, Jin-Young
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.805-808
    • /
    • 2008
  • Due to the fact that bare FBG sensors are very fragile, bare FBG sensor is not properly applied in practical infrastructures as it is not suitable to the rudeness of construction. Therefore packaged FBG sensors are developed for construction application. Since FBG senses strain and temperature simultaneously, temperature compensation for FBG strain sensors is indispensable. In this paper, temperature compensation techniques for steel sleeve packaged FBG sensors are brought forward. And its application on monitoring concrete beam was carried to test the feasibility of the temperature compensation technique. Temperature compensation technique used in this paper is feasible to be extended to structure health monitoring in civil engineering especially in large infrastructures etc.

  • PDF

Hardware temperature compensation technique for hot-wire anemometer by using photoconductive cell (광도전성저항을 이용한 열선유속계의 하드웨어적 온도보상에 관한 연구)

  • Lee, Sin-Pyo;Go, Sang-Geun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.11
    • /
    • pp.3666-3675
    • /
    • 1996
  • A new hardware temperature compensation method for hot-wire anemometer is investigated and an analog compensating circuit is proposed in this article. A photoconductive cell is introduced here as a variable resistor in the anemometer bridge and the linearized output of a thermistor is used to monitor the input of the photoconductive cell. In contrast with the conventional method, any type of temperature sensor can be used for compensation if once the output of thermometer varies linearly with temperature. So the present technique can diversify the compensating means from a conventional passive compensating resistance to currently available thermometers. Because the resistance of a photoconductive cell can be set precisely by adopting a stabilizing circuit whose operation is based on the integration function of the operational amplifier, the accuracy of compensation can be enhanced. As an example of linearized thermometer, thermistor sensor whose output is linearized by a series resistor was used to monitor the fluid temperature variation. Validation experiment is conducted in the temperature ranged from 30 deg. C to 60 deg. C and the velocity up to 40 m/s. It is found that the present technique can be adopted as a compensating circuit for anemometer and hot-wire type airflow meter.

Settlement Technique of Constrained On/Off Compensation Amount using Surplus Function in Electricity Market (잉여함수를 이용한 전력시장에서의 제약보상금액 정산기법)

  • 국경수;문영환;오태규
    • Journal of Energy Engineering
    • /
    • v.11 no.4
    • /
    • pp.324-331
    • /
    • 2002
  • ln competitive electricity market, useful technique would be required to calculate settlement amount for electric power traded between market participants and KPX since a number of market partici-pants would appear and trade electric power. Especially calculation of constrained on/off compensation amount can be complicated, and needs to be understood clearly by market participants to avoid unnecessary disputes. This paper presents a technique to settle more easily constrained on/off compensation amount using surplus function. In this technique, a surplus is calculated by each dispatched values and then the compen-sation amount is calculated by the difference of each surpluses. By doing this, settlement amount can be cal-culated by summing the trading amount and the compensation amount.

Hybrid Compensation Technique on Low Elevation Angle Errors for Multibeam Surveillance Radar in Multipath Environment (다중경로 환경에서 다중빔 탐색레이더에 적용 가능한 표적 고각오차 혼성 보정 기법)

  • Kim, Kwan Sung;Chung, Myung Soo;Jung, Chang Sik
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.16 no.3
    • /
    • pp.365-372
    • /
    • 2013
  • The multibeam surveillance radar is a state-of-art of 3D radar technology. It applies the stacked beams realized by a digital beamformer. In this paper, a hybrid compensation technique on elevation angle errors for low elevation angle targets over the sea in multipath radar environments is proposed. The proposed method can be applied to stacked beam radars. Double null algorithm based on maximum likelihood method in 3-D beamspace domain works well unless the phase difference between the two rays(direct and specular path) is close to $0^{\circ}$ and the magnitude of reflection coefficient is close to 0. To overcome these problems, we propose a hybrid compensation technique which uses the selective double null algorithm and the beam-ratio compensation technique for low-elevation errors on a log scale. Results of computer simulation show that the proposed method outperform conventional monopulse method and double null algorithm only under various multipath environments.

Feed-Forward Compensation Technique in Stationary Reference Frame for the Enhanced Disturbance Rejection Performance in Parallel Operation of Double-Conversion UPSs (이중 변환 UPS의 병렬 운전 시 외란 저감 성능 향상을 위한 정지 좌표계 상의 전향 보상 기법)

  • Ryu, Hyo-Jun;Yoon, Young-Doo;Mo, Jae-Sung;Choi, Seung-Cheol;Woo, Tae-Gyeom
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.27 no.5
    • /
    • pp.367-375
    • /
    • 2022
  • Generally, a proportional-resonant controller is used to eliminate steady-state errors during the voltage-current control of a double-conversion uninterruptible power supply (UPS) in a stationary reference frame. Additionally, the feed-forward control compensating for the load current, which can be considered a disturbance of the voltage controller, can be used to improve the disturbance rejection performance. However, during the parallel operation of UPSs, circulating current can occur between UPS modules when performing both feed-forward control and droop control because feed-forward control reduces the circulating current impedance. This study proposes a feed-forward compensation technique that considers the impedance of circulating current. An additional feed-forward compensation technique is developed to enhance the disturbance rejection performance. The validity of the proposed feed-forward compensation technique is verified by the experiment results of the parallel operation of a 500 W double-conversion UPS module.

A Robust Harmonic Compensation Technique using Digital Lock-in Amplifier under the Non-Sinusoidal Grid Voltage Conditions for the Single Phase Grid Connected Inverters (디지털 록인 앰프를 이용한 비정현 계통 전압 하에서 강인한 단상계통 연계 인 버터용 고조파 보상법)

  • Khan, Reyyan Ahmad;Ashraf, Muhammad Noman;Choi, Woojin
    • Proceedings of the KIPE Conference
    • /
    • 2018.11a
    • /
    • pp.95-97
    • /
    • 2018
  • The power quality of Single Phase Grid-Connected Inverters (GCIs) has received much attention with the increasing number of Distributed Generation (DG) systems. However, the performance of single phase GCIs get degraded due to several factors such as the grid voltage harmonics, the dead time effect, and the turn ON/OFF of the switches, which causes the harmonics at the output of GCIs. Therefore, it is not easy to satisfy the harmonic standards such as IEEE 519 and P1547 without the help of harmonic compensator. To meet the harmonic standards a certain kind of harmonic controller needs to be added to the current control loop to effectively mitigate the low order harmonics. In this paper, the harmonic compensation is performed using a novel robust harmonic compensation method based on Digital Lock-in Amplifier (DLA). In the proposed technique, DLAs are used to extract the amplitude and phase information of the harmonics from the output current and compensate it by using a simple PI controller in the feedforward manner. In order to show the superior performance of the proposed harmonic compensation technique, it is compared with those of conventional harmonic compensation methods in terms of the effectiveness of harmonic elimination, complexity, and implementation. The validity of the proposed harmonic compensation techniques for the single phase GCIs is verified through the experimental results with a 5kW single phase GCI. Index Terms -Single Phase Grid Connected Inverter (SPGCI), Harmonic Compensation Method, Total Harmonic Distortion (THD) and Harmonic Standard.

  • PDF

Incorporation of IMM-based Feature Compensation and Uncertainty Decoding (IMM 기반 특징 보상 기법과 불확실성 디코딩의 결합)

  • Kang, Shin-Jae;Han, Chang-Woo;Kwon, Ki-Soo;Kim, Nam-Soo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.37 no.6C
    • /
    • pp.492-496
    • /
    • 2012
  • This paper presents a decoding technique for speech recognition using uncertainty information from feature compensation method to improve the speech recognition performance in the low SNR condition. Traditional feature compensation algorithms have difficulty in estimating clean feature parameters in adverse environment. Those algorithms focus on the point estimation of desired features. The point estimation of feature compensation method degrades speech recognition performance when incorrectly estimated features enter into the decoder of speech recognition. In this paper, we apply the uncertainty information from well-known feature compensation method, such as IMM, to the recognition engine. Applied technique shows better performance in the Aurora-2 DB.

An a-Si:H TFT Pixel Circuit with Novel Threshold Voltage Compensation Technique for AMOLED Displays

  • Shin, Min-Seok;Min, Ung-Gyu;Choi, Jung-Hwan;Song, Jun-Yong;Lee, Seung-Yong;Kwon, Oh-Kyong
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.1697-1700
    • /
    • 2006
  • A Novel pixel structure with a new threshold voltage compensation technique is proposed for large-size a-Si:H AMOLED panel application. The proposed pixel improves image quality with threshold voltage compensation and alleviates annealing technique for display-off time. Sensing the threshold voltage of driving TFT for 20-inch WUXGA panel is verified by the HSPICE simulation.

  • PDF