• Title/Summary/Keyword: Compensation Factor

Search Result 601, Processing Time 0.024 seconds

Harmonics Reduction in Load control and Management system

  • Thueksathit, W.;Tipsuwanporn, V.;Hemawanit, P.;Gulpanich, S.;Srisuwan, K.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.2283-2286
    • /
    • 2003
  • This paper presents conservation of electrical energy in building with harmonics analysis and compensation which occur in electrical system. We use load controlling and management system in order to adjust load factor of system.The maximum demand limiting and controlling are used ,then the system can acquire the prediction and compare it to the maximum demand set point.The electrical signal analysis based on FFT technique. The harmonics are compensated by using harmonic filters.This system consists computer which works as controller, processor , analysis and database unit together with digital power meter in form of multidrop network through serial communication via RS-485.The load control system uses PLC to control load via serial communication RS-485. The A/D converter is used for sampling the electrical signals via parallel port of computer.The harmonic filters are controlled by a computer.The data of measurement such as voltage, current, power, power factor, total harmonic distortion, energy, etc., can be saved as database and analysis. The load factor is adjusted by limiting and controlling maximum demand. The load factor adjustment can reduce the cost of electric consumption and energy generation together with harmonics compensation in order to increase high efficiency of electrical system.

  • PDF

Analysis of the Distribution STATCOM Operating Results for Improving Distribution System Power Quality (전력품질 향상을 위한 배전용 STATCOM 운전결과 분석)

  • 오관일;전영수;박상태;추진부
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.5 no.4
    • /
    • pp.377-385
    • /
    • 2000
  • This paper presents the test and operation results of the domestic demonstration of the reactive power compensation device called STATCOM (STATic COMpensator). The object of the paper is to describe the reliability of the unit based on the extensive operation databases. The custom power is similar in nature to the concept of FACTS(Flexibel AC Transmission System). By controlling reactive power, the technology offers utilities the opportunity for increased efficiency and their capabilities will permit transmission planners make the best use of their existing transmission resources. STATCOM is a custom power device in a way and can be used in a similar way for the dynamic compensation of power transmission systems, providing reactive power compensation, voltage regulation and mitigation of voltage flicker. It is shown that the STATCOM has clear advantages in areas such as; providing reactive power compensation and improving power factor.

  • PDF

Compensation of Arousal Level Criteria by a Modified KSS Scale (수정된 KSS 측도에 의한 각성도 평가기준 보상법)

  • 고한우;김연호
    • Journal of Biomedical Engineering Research
    • /
    • v.18 no.4
    • /
    • pp.477-484
    • /
    • 1997
  • In this paper, we proposed the compensation method to evaluate arousal level in different initial arousal states. Arousal level was measured by the relationship between IRI and Nz. Since Nz is affected by BI which is directly proportional to initial arousal state of subjects, the arousal level is underestimated To overcome this problem, we proposed the compensation method using modified Karolinska sleepiness scale, and determined compensation coefficients derived from this scale with five arousal levels. Applying these coefficients to portable arousal monitoring system, the proposed method in this paper could be useful for real-time evaluation and control of arousal level. As a result the developed system can detect and control the arousal state from initial drowsing sate.

  • PDF

Real-time hybrid testing using model-based delay compensation

  • Carrion, Juan E.;Spencer, B.F. Jr.
    • Smart Structures and Systems
    • /
    • v.4 no.6
    • /
    • pp.809-828
    • /
    • 2008
  • Real-time hybrid testing is an attractive method to evaluate the response of structures under earthquake loads. The method is a variation of the pseudodynamic testing technique in which the experiment is executed in real time, thus allowing investigation of structural systems with time-dependent components. Real-time hybrid testing is challenging because it requires performance of all calculations, application of displacements, and acquisition of measured forces, within a very small increment of time. Furthermore, unless appropriate compensation for time delays and actuator time lag is implemented, stability problems are likely to occur during the experiment. This paper presents an approach for real-time hybrid testing in which time delay/lag compensation is implemented using model-based response prediction. The efficacy of the proposed strategy is verified by conducting substructure real-time hybrid testing of a steel frame under earthquake loads. For the initial set of experiments, a specimen with linear-elastic behavior is used. Experimental results agree well with the analytical solution and show that the proposed approach and testing system are capable of achieving a time-scale expansion factor of one (i.e., real time). Additionally, the proposed method allows accurate testing of structures with larger frequencies than when using conventional time delay compensation methods, thus extending the capabilities of the real-time hybrid testing technique. The method is then used to test a structure with a rate-dependent energy dissipation device, a magnetorheological damper. Results show good agreement with the predicted responses, demonstrating the effectiveness of the method to test rate-dependent components.

Effect of the Signal-to-Noise Power Spectra Ratio On MTF compensated EOC images

  • Kang, Chi-Ho;Choi, Hae-Jin
    • Proceedings of the KSRS Conference
    • /
    • 2002.10a
    • /
    • pp.202-207
    • /
    • 2002
  • EOC (Electro-Optical Camera) of KOMPSAT-1 (Korea Multi-Purpose SATellite) has been producing land imageries of the world since January 2000. After image data are acquired by EOC, they are transmitted from satellite to ground via X-band RF signal. Then, EOC image data are generated and pass through radiometric and geometric corrections to generate standard products of EOC images. After radiometric correction on EOC image data, Modulation Transfer Function (MTF) compensation is applicable on EOC images with user's request for better image quality. MTF compensation is concerned with filtering EOC images to minimize the effect of degradations. For Image Receiving and Processing System (IRPE) at KOMPSAT Ground Station (KGS), Wiener filter is used in MTF compensation for EOC images. If the Pointing Spread Function (PSF) of EOC system is known, signal-to-noise power spectra ratio is the only factor in the determination of Wiener filter. In this paper, MTF compensation in IRPE at KGS is introduced and MTF compensated EOC 1R images are generated using Wiener filters with various signal-to-noise power spectra ratios. MTF compensated EOC 1R images are correlated with EOC 1R images for observing linearities between them. As a result, the effect of signal-to-noise power spectra ratio is shown on MTF compensated EOC 1R images.

  • PDF

Study on Simulation and Calculation Method of Thermal Error Compensation System for a Ball Screw Feed Drive (볼 스크류 이송장치 열 에러 보상 시스템의 시뮬레이션 및 계산 방법에 관한 연구)

  • Xu, Zhe Zhu;Choi, Chang;Kim, Lae-Sung;Baek, Kwon-In;Lyu, Sung-ki
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.16 no.2
    • /
    • pp.88-93
    • /
    • 2017
  • Due to the requirement of the development of the precision manufacturing industry, the accuracy of machine tools has become a key issue in this field. A critical factor that affects the accuracy of machine tools is the feed system, which is generally driven by a ball screw. Basically, to improve the performance of the feed drive system, which will be thermally extended lengthwise by continuous usage, a thermal error compensation system that is highly dependent on the feedback temperature or positioning data is employed in the machine tool system. Due to the overdependence on measuring technology, the cost of the compensation system and low productivity level are inevitable problems in the machine tool industry. This paper presents a novel feed drive thermal error compensation system method that could compensate for thermal error without positioning or temperature feedback. Regarding this thermal error compensation system, the heat generation of components, principal of compensation, thermal model, mathematic model, and calculation method are discussed. As a result, the test data confirm the correctness of the developed feed drive thermal error compensation system very well.

Mathatical Analysis for Efficiency of Power Factor Correction System Using IP3003 (타려식 형광등 안정기용 구동 반도체 IP3102의 온도 보상 설계법)

  • Joo, Sung-Juni;Chang, Cheon-Seop
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.05a
    • /
    • pp.152-156
    • /
    • 2007
  • We introduce the IP3102 which is developed by Interpion Semiconductor co. LTD. for the CFL ballaster. The IP3102 has thermal compensation function. In this paper, we present the temperature compensation design technique and its implementation in the IP3102. The experimental results is also presented in this paper.

  • PDF

ESTIMATION OF REQUIRED CAPACITY OF SHUNT TYPE ACTIVE POWER FILTER WITH A THYRISTOR CONVERTER LOAD

  • Jeong, Seung-Gi;Kim, Dong-Ha
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.802-807
    • /
    • 1998
  • The main drawback of parallel type active power filters (APF) is the large capacity required for harmonic compensation. This paper evaluates the APF capacity requirement of harmonic/reactive power compensation for thyristor converter load. Theoretically achievable maximum power factor under partial load is evaluated. And it is shown that the APF capacity can be considerably reduced while slightly sacrificing the filtering performance by deliberately limiting the peak current of the APF.

  • PDF

A study on compensation of arousal level criteria (각성도 평가기준 보상법에 대한 연구)

  • Ko, H.W.;Kim, Y.H.;Lee, G.K.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.11
    • /
    • pp.86-89
    • /
    • 1996
  • This paper describes compensation method to evaluate arousal level in different initial arousal state. Arousal level was measured by the relationship between IRI and Nz. The value of Nz is affected by BI which is variable with initial drowsiness. we introduced a correction factor to compensate these differences.

  • PDF

Development of Scale on Selection, Optimization, Compensation(SOC) Model as Successful Aging Strategies of Korean Elderly (한국노인의 성공적 노화 전략으로서의 선택·최적화·보상(SOC) 척도 개발에 관한 연구)

  • Sohn, Eui-Seong
    • 한국노년학
    • /
    • v.31 no.2
    • /
    • pp.381-400
    • /
    • 2011
  • The purpose of this study is to develop the scale on Selection, Optimization, Compensation(SOC) model as successful aging strategies of Korean Elderly. In first phase of the study, 64 pilot items were collected from researcher's indepth interviews with a purposive sample group of 24 elderly people(16 items) and original SOC scale(48 items). To analyze the factor structure and to verify the validity of the scale, 592 questionnaires collected from survey were divided randomly into 300 developmental samples and 292 validity samples. The items were examined exploratory with developmental samples and confirmatory factor analysis with developmental samples. Two factor analysis supported four factor structure of the SOC consisted of 20 items. Four factors are as follows: 'Elective Selection', 'Loss-Based Selection', 'Opimization', 'Compensation'. The cronbach's alpha estimate of the scale was .930. This scale of four factor model exhibited good fit, assessed by overall fit measure criteria(TLI=.939, CFI=.947, RMSEA=.058). The result of analysis by item response theory for SOC scale is satisfatory. Also, SOC scale was significantly related to the two successful aging scales for Korean elderly and life satisfation scale(SWLS). These results proved the validity of the scale.