• Title/Summary/Keyword: Comparison of images

Search Result 1,777, Processing Time 0.04 seconds

$^{18}F$-FDG PET/CT in Patients with Initially Diagnosed Adenoid Cystic Carcinoma of the Head and Neck: Clinicoplathologic Correlation (처음 진단된 두경부 선양낭성암종에서 $^{18}F$-FDG PET/CT: 임상상 및 병리소견과의 상관성)

  • Lee, Ji-Young;Choi, Joon-Young;Ko, Young-Hyeh;Baek, Chung-Hwan;Son, Young-Ik;Cho, Suk-Kyong;Cheon, Mi-Ju;Lee, Kyung-Han;Kim, Byung-Tae
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.5
    • /
    • pp.395-401
    • /
    • 2009
  • Purpose: We evaluated $^{18}F$-FDG PET/CT findings in initially diagnosed adenoid cystic carcinoma (ACC) of the head and neck in association with pathological subtype, staging, uptake comparison with squamous cell carcinoma (SqCC) and prognosis. Materials and Methods: The subjects were 16 patients with initially diagnosed ACC of head and neck who underwent pretreatment $^{18}F$-FDG PET/CT. Histological subtype (solid pattern vs. tubular/cribriform pattern), $SUV_{max}$ of size-matched SqCC of the head and neck as control group, disease-free survival (DFS) were compared with the $SUV_{max}$ of ACC of the head and neck. Results: Of total 16 patients, 6 had solid pattern and the remaining 10 had tubular/cribriform pattern. The $SUV_{max}$ were significantly higher in solid pattern group than in tubular/cribriform pattern group ($6.7{\pm}3.2$ vs. $4.2{\pm}0.9$, p=0.03). PET/CT found unexpected distant metastasis in 18.7% of patients (3/16) and changed the therapeutic plan in those patients. The $SUV_{max}$ of ACC was significantly lower than that of size-matched SqCC ($5.1{\pm}2.4$ vs. $13.6{\pm}6.0$, p<0.001). DFS was not significantly different according to the histological subtype. In contrast, patients with high $^{18}F$-FDG uptake ($SUV_{max}$ ${\geq}$6.0) had significantly shorter DFS than those with low $^{18}F$-FDG uptake ($SUV_{max}$ <6.0). Conclusion: $^{18}F$-FDG uptake of ACC of the head and neck is significantly associated with histological subtype and DFS. $^{18}F$-FDG PET/CT may be useful for detecting unexpected metastasis. Since $^{18}F$-FDG uptake of tubular/cribriform ACC compared with SqCC is relatively low, it is necessary to interpret PET images carefully in patients without alleged ACC.

Seasonal and Yearly Variations of Atmospheric Extinction Coefficient at Campus Station of Chungbuk National University Observatory from 2005 to 2007 (충북대학교 천문대 교내관측소에서 측정된 2005년부터 2007년까지의 대기소광계수의 계절별, 년도별 변화)

  • Kim, Chun-Hwey;Cha, Sang-Mok;Choi, Young-Jae;Song, Mi-Hwa;Park, Jang-Ho;Won, Jang-Hee;Yim, Jin-Sun;Cho, Myung-Shin;Park, Eun-Mi;Jeong, Jang-Hae
    • Journal of Astronomy and Space Sciences
    • /
    • v.25 no.2
    • /
    • pp.101-112
    • /
    • 2008
  • Systematic CCD observations of times of minimum lights for eclipsing binaries has been carried out from 2002 to 2007 at Campus Station of Chungbuk National University Observatory which is located in Cheongju city, Korea. As a by-product of our observations, photometric data for stars in CCD images taken from 2005 to 2007 were used to determine 1st order atmospheric extinction coefficient (hereafter AEC) and seasonal and yearly variations of the AECs were studied. Total nights used for determination of AECs were 57 days in 2005, 51 days in 2006, and 63 days in 2007. As a result the annual mean value of the AECs per air mass is calculated as $0.^m34{\pm}0.^m18$ for 2005, $0.^m38{\pm}0.^m19$ for 2006, and $0.^m45{\pm}0.^m20$ for 2007. These values show that the AECs and their standard deviations are two and four times, respectively, larger than those of normal observatories which are not located near large cities. Annual comparison between concentration of atmospheric fine dust and coefficient of atmospheric extinction show strong correlation between two quantities of which time variations show similar patterns. The AECs for the east sky show larger than those for the west sky. It can be easily understood by the reasonable possibility that air pollutants remain more in the east sky than in the west because the east area of Cheongju city has been more developed than the west one. In conclusion the atmospheric extinction of the night sky of Cheongju city has an annual trend of increase of $0.^m06\;airrnass^{-1}\; year^{-1}$ implying that it may take only about 13 years for Cheongju city to have 2 times brighter night sky than the present one. Our study highlights that variations of AEC can be used as an important indicator of air pollution to monitor night skies.

A Low-Dose High-Resolution SPECT System with CdTe for Small-Animal Imaging Applications: A GATE Simulation Study (GATE 시뮬레이션을 통한 고해상도 저선량용 소동물 영상화를 위한 CdTe 검출기 기반의 SPECT 기기 연구)

  • Park, Su-Jin;Yu, A Ram;Kim, Yeseul;Lee, Young-Jin;Kim, Hee-Joung
    • Progress in Medical Physics
    • /
    • v.24 no.3
    • /
    • pp.162-170
    • /
    • 2013
  • Dedicated single-photon emission computed tomography (SPECT) systems based on pixelated semiconductors are being developed for studying small animal models of human disease. To clarify the possibility of using a SPECT system with CdTe for a high resolution low-dose small animal imaging, we compared the quality of reconstructed images from pixelated CdTe detector to those from a small SPECT system with NaI(Tl). The CdTe detector was $44.8{\times}44.8$ mm and the pixels were $0.35{\times}0.35{\times}5$ mm. The intrinsic resolution of the detector was 0.35 mm, which is equal to the pixel size. GATE simulations were performed to assess the image quality of both SPECT systems. The spatial resolutions and sensitivities for both systems were evaluated using a 10 MBq $^{99m}Tc$ point source. The quantitative comparison with different injected dose was performed using a voxelized MOBY phantom, and the absorbed doses for each organ were evaluated. The spatial resolution of the SPECT with NaI(Tl) was about 1.54 mm FWHM, while that of the SPECT with a CdTe detector was about 1.32 mm FWHM at 30 mm. The sensitivity of NaI(Tl) based SPECT was 83 cps/MBq, while that of the CdTe detector based SPECT was 116 cps/MBq at 30 mm. The image statistics were evaluated by calculating the CNR of the image from both systems. When the injected activity for the striatum in the mouse brain was 160 Bq/voxel, the CNR of CdTe based SPECT was 2.30 while that of NaI(Tl) based SPECT was 1.85. The CNR of SPECT with CdTe was overall higher than that of the NaI(Tl) based SPECT. In addition, the absorbed dose was higher from SPECT with CdTe than those from NaI(Tl) based SPECT to acquire the same quantitative values. Our simulation results indicated that the SPECT with CdTe detector showed overall high performance compared to the SPECT with NaI(Tl). Even though the validation study is needed, the SPECT system with CdTe detector appeared to be feasible for high resolution low-dose small animal imaging.

[ $^{99m}Tc-DISIDA$ ] Scintigraphic Diagnosis Of Extrahepatic Hepatocellular Carcinoma Metastasis : Comparison with Primary Hepatocellular Carcinoma ($^{99m}Tc-DISIDA$ 신티그래피를 이용한 간세포암 간외 전이의 진단 : 원발 간세포암과의 비교)

  • Chung, Soo-Kyo;Kim, Sung-Hoon;Baik, Joon-Hyun;Kim, Young-Joo;Chun, Kyung-Ah;Park, Seog-Hee;Bahk, Yong-Whee;Shin, Kyung-Sub
    • The Korean Journal of Nuclear Medicine
    • /
    • v.29 no.4
    • /
    • pp.484-491
    • /
    • 1995
  • It is well known that hepatobiliary agent are taken up by metastatic hepatocellular carcinoma(HCC) as well as primary HCC. But the reported cases of the extrahepatic metastasis of HCC diagnosed by hepatobiliary scintigraphy are for the most part hematogenous ones. The relation of the uptake pattern of hepatobiliary agent in the primary and metastatic HCC is also still remains unknown. So we undertook this study to evaluate the relation of the hepatobiliary scintigraphic patterns of primary and metastatic HCC with different metastatic routes. Nine patients with primary HCC and twelve cases of metastatic HCC including four lung metastases, one bone metastasis, one right atrial metastasis, one peritoneal wall metastasis, and five lymph node metastases were studied with $^{99m}Tc-DISIDA$ scintigraphy. The images were taken on 10, 30 minutes, 1, 2, 4-6 hours. The overall detection rates of hematogenous metastases(lung and bone) is 60%(3 of 5), direct metastasis(right atrium and peritoneal wall), 100%(2 of 2) and lymphatic metastases, 0%(0 of 5). In four of five metastatic cases demonstrated with hepatobiliary scintigraphy, biliary agent is also taken up by primary HCC lesions. And the appearing time of the radioactivity in the direct metastatic HCC lesioin is same as that of primary HCC and in the cases of hematogenous metastasis, earlier than that of primary HCC. Hepatobiliary scintigraphy is more useful in the diagnosis of the metastatic HCC than primary HCC, in the cases of hematogenous and direct metastasis.

  • PDF

Acute Cerebral Infarction in a Rabbit Model: Perfusion and Diffusion MR Imaging (가토의 급성 뇌경색에서 관류 및 확산강조 자기공명영상)

  • Heo Suk-Hee;Yim Nam-Yeol;Jeong Gwang-Woo;Yoon Woong;Kim Yun-Hyeon;Jeong Young-Yeon;Chung Tae-Woong;Kim Jeong;Park Jin-Gyoon;Kang Heoung-Keun;Seo Jeong-Jin
    • Investigative Magnetic Resonance Imaging
    • /
    • v.7 no.2
    • /
    • pp.116-123
    • /
    • 2003
  • Purpose : The present study was undertaken to evaluate the usefulness of cerebral diffusion (DWI) and perfusion MR imaging (PWI) in rabbit models with hyperacute cerebral ischemic infarction. Materials and Methods : Experimental cerebral infarction were induced by direct injection of mixture of Histoacryl glue, lipiodol, and tungsten powder into the internal cerebral artery of 6 New-Zealand white rabbits, and they underwent conventional T1 and T2 weighted MR imaging, DWI, and PWI within 1 hour after the occlusion of internal cerebral artery. The PWI scan for each rabbit was obtained at the level of lateral ventricle and 1cm cranial to the basal ganglia. By postprocessing using special imaging software, perfusion images including cerebral blood volume (CBV), cerebral blood flow (CBF), and mean transit time (MTT) maps were obtained. The detection of infarcted lesion were evaluated on both perfusion maps and DWI. MTT difference time were measured in the perfusion defect lesion and symmetric contralateral normal cerebral hemisphere. Results : In all rabbits, there was no abnormal signal intensity on T2WI. But on DWI, abnormal high signal intensity, suggesting cerebral infarction, were detected in all rabbits. PWI (rCBV, CBF and MTT map) also showed perfusion defect in all rabbits. In four rabbits, the calculated square of perfusion defect in MTT map is larger than that of CBF map and in two rabbits, the calculated size of perfusion defect in MTT map and CBF map is same. Any rabbits do not show larger perfusion defect on CBF map than MTT map. In comparison between CBF map and DWI, 3 rabbits show larger square of lesion on CBF map than on DWI. The others shows same square of lesion on both technique. The size of lesion shown in 6 MTT map were larger than DWI. In three cases, the size of lesion shown in CBF map is equal to DWI. But these were smaller than MTT map. The calculated square of lesion in CBF map, equal to that of DWI and smaller than MTT map was three. And in one case, the calculated square of perfusion defect in MTT map was largest, and that of DWI was smallest. Conclusion : DWI and PWI may be useful in diagnosing hyperacute cerebral ischemic infarction and in e-valuating the cerebral hemodynamics in the rabbits.

  • PDF

A Pilot Study for the Remote Monitoring of IMRT Using a Head and Neck Phantom (원격 품질 보증 시스템을 사용한 세기변조 방사선치료의 예비 모니터링 결과)

  • Han, Young-Yih;Shin, Eun-Hyuk;Lim, Chun-Il;Kang, Se-Kwon;Park, Sung-Ho;Lah, Jeong-Eun;Suh, Tae-Suk;Yoon, Myong-Geun;Lee, Se-Byeong;Ju, Sang-Gyu;Ahn, Yong-Chan
    • Radiation Oncology Journal
    • /
    • v.25 no.4
    • /
    • pp.249-260
    • /
    • 2007
  • Purpose: In order to enhance the quality of IMRT as employed in Korea, we developed a remote monitoring system. The feasibility of the system was evaluated by conducting a pilot study. Materials and Methods: The remote monitoring system consisted of a head and neck phantom and a user manual. The phantom contains a target and three OARs (organs at risk) that can be detected on CT images. TLD capsules were inserted at the center of the target and at the OARs. Two film slits for GafchromicEBT film were located on the axial and saggital planes. The user manual contained an IMRT planning guide and instructions for IMRT planning and the delivery process. After the manual and phantom were sent to four institutions, IMRT was planed and delivered. Predicted doses were compared with measured doses. Dose distribution along the two straight lines that intersected at the center of the axial film was measured and compared with the profiles predicted by the plan. Results: The measurements at the target agreed with the predicted dose within a 3% deviation. Doses at the OARs that represented the thyroid glands showed larger deviations (minimum 3.3% and maximum 19.8%). The deviation at OARs that represented the spiral cord was $0.7{\sim}1.4%$. The percentage of dose distributions that showed more than a 5% of deviation on the lines was $7{\sim}27%$ and $7{\sim}14%$ along the horizontal and vertical lines, respectively. Conculsion: Remote monitoring of IMRT using the developed system was feasible. With remote monitoring, the deviation at the target is expected to be small while the deviation at the OARs can be very large. Therefore, a method that is able to investigate the cause of a large deviation needs to be developed. In addition, a more clinically relevant measure for the two-dimensional dose comparison and pass/fail criteria need to be further developed.

Comparison Evaluation of Image Quality with Different Thickness of Aluminum added Filter using GATE Simulation in Digital Radiography (GATE 시뮬레이션을 사용한 알루미늄 부가필터 두께에 따른 Digital Radiography의 영상 화질 비교 평가)

  • Oh, Minju;Hong, Joo-Wan;Lee, Youngjin
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.1
    • /
    • pp.81-86
    • /
    • 2019
  • In X-ray image, the role of filtration through the filter is to reduce the exposure of the patient by using photon which is useful in formation of the image, and at the same time, enhance the contrast of the image. During interaction between photon and object, low energy X-rays are absorbed from the site of a few cm of the first patient's tissue, and high energy X-rays are the one which form the image. Therefore, the radiation filter absorbs low energy X-ray in order to lower the exposure of the patient and improve the quality of the image. The purpose of this study is to compare the effect on the image quality by differences of added filter through simulation image and actual radiation image. For that purpose, we used Geant4 Application for Tomographic Emission (GATE) as a tool for Monte Carlo simulation. We set actual size, shape and material of Polymethylmethacrylate (PMMA) Phantom on GATE and differentiated the parameter of added filter. Also, we took image of PMMA phantom with same parameter of added filter by digital radiography (DR). Than we performed contrast-to-noise ratio (CNR) evaluation on both simulation image and actual DR image by Image J. Finally, we observed the effect on image quality due to different thickness of added filter, and compared two images' CNR evaluation's transitions of change. The result of this experiment showed decreasing in the progress of CNR on both DR and simulation image. It is ultimately caused by decreasing in contrast on image. In theory, contrast decrease with kVp increased. Given that condition, this study found out that filter makes not only decreasing total dose by absorbing low energy of X-ray, but also increasing average energy of X-ray.

Assessment of the Synovial Inflammation in Rheumatoid Arthritis with $^{99m}Tc$-labelled Polyclonal Human IgG(HIG): Prospective Comparison with Gadolinium Enhanced MRI ($^{99m}Tc$-labelled HIG 스캔을 이용한 류마티스 관절염 환자에서 활막염증의 평가 : 조영증강 자기공명영상과의 전향적인 비교)

  • Ryu, Young-Hoon;Lee, Jong-Doo;Suh, Jin-Suck;Park, Chang-Yun;Jeon, Pyoung;Na, Jae-Beom;Lee, Soo-Kon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.29 no.1
    • /
    • pp.84-91
    • /
    • 1995
  • Many clinical and laboratory tests have been employed to evaluate disease activity in rheumatioid arthritis. $^{99m}Tc$-labelled polyclonal IgG(HIG) has been demonstrated to accumulate in focal sites of infection or inflammation in both animals and human subjects. The purpose of this study was to distinguish arthritis with active inflammation from those without active inflammation and to correlate relative intensities of $^{99m}Tc$-labelled HIG uptake of the rheumatoid arthritis with clinical and MR indices of the joint inflammation. This study included twelve patients with active rheumatoid arthritis, two with ankylosing spondylitis and one with degenerative osteoarthritis without active inflammation. A Whole-body and spot images were obtained 4 hours after intravenous injection of 20mCi of $^{99m}Tc$-labelled HIG. Scintigrams were assessed visually by 3 experienced radiologists, and graded as normal or mildly and markedly increased uptake within the joints, and the degree of uptake was compared with clinical and radiologic severity of synovial inflammation. MRI studies were done on the involved joints consisted of wrist(n = 11), knee(n = 2) and hip joint(n= 2). Active synovitis was defined when marked elevation of ESR and gadolinium enhancement of synovium on MRI were demonstrated. Markedly increased radiotracer uptake was seen in 10 of 11 rheumatoid arthritic patients with active synovitis whereas normal or mildly increased uptakes were noted in others, including rheumatoid arthritic patient(n=1) and non-rheumatoid patients(n = 3) without active synovitis. This study showed that the localization of involved joints in rheumatoid arthritis could be detected with $^{99m}Tc$-labelled HIG and that the degree of uptake correlated well with the degree and activity of inflammation. In conclusion, $^{99m}Tc$-labelled HIG scan is a useful method in the evaluation of active inflammation in rheumatoid arthritis.

  • PDF

A Study on the Effect of Using Sentiment Lexicon in Opinion Classification (오피니언 분류의 감성사전 활용효과에 대한 연구)

  • Kim, Seungwoo;Kim, Namgyu
    • Journal of Intelligence and Information Systems
    • /
    • v.20 no.1
    • /
    • pp.133-148
    • /
    • 2014
  • Recently, with the advent of various information channels, the number of has continued to grow. The main cause of this phenomenon can be found in the significant increase of unstructured data, as the use of smart devices enables users to create data in the form of text, audio, images, and video. In various types of unstructured data, the user's opinion and a variety of information is clearly expressed in text data such as news, reports, papers, and various articles. Thus, active attempts have been made to create new value by analyzing these texts. The representative techniques used in text analysis are text mining and opinion mining. These share certain important characteristics; for example, they not only use text documents as input data, but also use many natural language processing techniques such as filtering and parsing. Therefore, opinion mining is usually recognized as a sub-concept of text mining, or, in many cases, the two terms are used interchangeably in the literature. Suppose that the purpose of a certain classification analysis is to predict a positive or negative opinion contained in some documents. If we focus on the classification process, the analysis can be regarded as a traditional text mining case. However, if we observe that the target of the analysis is a positive or negative opinion, the analysis can be regarded as a typical example of opinion mining. In other words, two methods (i.e., text mining and opinion mining) are available for opinion classification. Thus, in order to distinguish between the two, a precise definition of each method is needed. In this paper, we found that it is very difficult to distinguish between the two methods clearly with respect to the purpose of analysis and the type of results. We conclude that the most definitive criterion to distinguish text mining from opinion mining is whether an analysis utilizes any kind of sentiment lexicon. We first established two prediction models, one based on opinion mining and the other on text mining. Next, we compared the main processes used by the two prediction models. Finally, we compared their prediction accuracy. We then analyzed 2,000 movie reviews. The results revealed that the prediction model based on opinion mining showed higher average prediction accuracy compared to the text mining model. Moreover, in the lift chart generated by the opinion mining based model, the prediction accuracy for the documents with strong certainty was higher than that for the documents with weak certainty. Most of all, opinion mining has a meaningful advantage in that it can reduce learning time dramatically, because a sentiment lexicon generated once can be reused in a similar application domain. Additionally, the classification results can be clearly explained by using a sentiment lexicon. This study has two limitations. First, the results of the experiments cannot be generalized, mainly because the experiment is limited to a small number of movie reviews. Additionally, various parameters in the parsing and filtering steps of the text mining may have affected the accuracy of the prediction models. However, this research contributes a performance and comparison of text mining analysis and opinion mining analysis for opinion classification. In future research, a more precise evaluation of the two methods should be made through intensive experiments.

Effect of conservative therapy and Mandibular condylar bone change on Adolescents with osteoarthritis of TMJ (청소년 측두하악관절 골관절염의 보존적 치료효과 및 관절면의 변화 비교)

  • Jeon, Hye-Mi;Kim, Kyung-Hee;Ok, Soo-Min;Heo, Jun-Young;Jeong, Sung-Hee;Ko, Myung-Yun;Ahn, Young-Woo
    • Journal of Oral Medicine and Pain
    • /
    • v.38 no.4
    • /
    • pp.357-366
    • /
    • 2013
  • This study is designed to evaluate the treatment outcome of occlusal stabilizing splint and to assess follow-up study of condylar bony changes using cone beam computed tomography(CBCT) in adolescents patients (12-19 years) with TMJ osteoarthritis(OA). 167 eroded condyles in 149 subjects were chosen among the patients who presented to the Department of Oral Medicine of Pasan National University Hospital, diagnosed as TMJ osteoarthritis by clinical exam, x-ray and CBCT from 2009 to 2012. They were treated conservatively with physical therapy, medication, behavioral therapy and occlusal stabilizing splint therapy. After average 9 months, CBCT was retaken and subjective symptoms and clinical findings were investigated. Condyle bony changes were classified by unchanged, less severe and more severe. The obtained results were as follow: 1. Pain, Noise, LOM(Limitation of motion) and MCO(Maximum comfortable opening) measurement of TMJ OA patients were markedly improved after conservative treatment. 2. In the occlusal stabilizing splint therapy group, Pain and LOM were statistically significant improved than non-occlusal stabilizing splint therapy group. 3. In the acute occlusal stabilizing splint therapy group, Pain and LOM were remarkably improved. 4. In comparison of CBCT1 and CBCT2 images, the transition of bone changes to lesser severe was most commonly in joint with erosive change. 5. In the non-occlusal stabilizing splint therapy group, the transition of condylar bone changes from erosion to more severe was many than occlusal stabilizing splint therapy group.