• 제목/요약/키워드: Comparison analysis

검색결과 17,655건 처리시간 0.038초

안전화 사이즈 설정을 위한 남성의 발에 관한 연구 (A Study on Men`s Foot for Size Establishment of Safety Shoes)

  • 임영문;신경진
    • 대한안전경영과학회:학술대회논문집
    • /
    • 대한안전경영과학회 2007년도 추계학술대회
    • /
    • pp.263-268
    • /
    • 2007
  • The main objective of this study is to provide numerical guideline for size establishment of safety shoes about adult men(over 20 years) compared to physical standards of nation (report published in 1997). The sample for this work was chosen from data which were collected and measured by Size Korea during two years (2003${\sim}$2004). In order to analyze and compare features of men's foot, analysis was performed about 1,685 subjects on 2 parts such as foot length and foot circumference. For the specific comparison on foot size, Mollison's comparison graph was used. The result of this study can be applied in manufacturing and design of shoes and socks. Also, it will enable us to have fruitful information on considerable items during manufacturing and design of safety shoes.

  • PDF

C-G Method를 이용한 지그재그 노면표시의 교통사고 감소효과 분석 (Estimation of Traffic Accident Effectiveness of Zig-zag Marking Using a Comparison Group Method)

  • 권성근;이영인;조성준
    • 한국도로학회논문집
    • /
    • 제14권6호
    • /
    • pp.149-158
    • /
    • 2012
  • PURPOSES : This research is to evaluate the effects of zig-zag marking. METHODS : Based on the literature review, This research adopt Comparison Group method which was developed by Hauer. RESULTS : The findings are as follows. Effectiveness of treatment at all site 1.06, intersection 0.92, median bus lane 1.93, school zone 0.50, below 6-lane 0.48, above 6-lane 1.19, cat vs person 0.57, car vs car 1.36, car only 1.29. CONCLUSIONS : Though the analysis, it was founded that zig-zag marking on the small scale road(below 6-lane) and school zone contribute to reduce traffic accidents(effectiveness of the treatment : 0.50, 0.48). But the accidents at large scale road and median bus lane where installed zig-zag marking demonstrated negative result.(effectiveness of the treatment indicates exceed 1.0).

Order Statistics를 적용한 Patchwork의 성능 개선 분석 (Performance Analysis of Order Statistics Patchwork)

  • 국효정;김용철
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2003년도 컴퓨터소사이어티 추계학술대회논문집
    • /
    • pp.163-166
    • /
    • 2003
  • In conventional patchwork, the difference of the mean values of two groups is compared for watermark detection. We propose two modified patchwork schemes based on order statistics, which achieves significant improvements over conventional patchwork. First, we propose that the mean comparison is replaced by the median comparison, to get PSNR improvement due to informed watermarking. Second, we propose a majority voting scheme of a sequential comparison of pixel pairs in a sorted order, which produces significantly lower BER. The performance improvements are mathematically analyzed and tested. In experimental results, PSNR is about 5㏈~10㏈ higher in the first method and BER is about 1/5~l/2 times lower in the second method than conventional patchwork.

  • PDF

항공기 날개 보의 중량경감용 천공 형상연구

  • 이시훈;공두현;신상준
    • EDISON SW 활용 경진대회 논문집
    • /
    • 제6회(2017년)
    • /
    • pp.304-310
    • /
    • 2017
  • In this paper, various webs of I-shaped beam used in aircraft spars are examined. Under the assumption that an aircraft spar is a cantilevered beam with a constant cross-section and is subjected to only bending, four kinds of webs are analyzed for three different sizes. To enable comparison, each hole has the same area and are subjected to the same load by using EDISON 2D Continuum analysis. While circular hole is the most often used, elliptic one is obtained with the minimum von-Mises stress by about 40% decreased. To verify the results gathered by EDISON, comparison was made with ANSYS and analytic predictions obtained with the stress intensity factor K. As comparison shows insignificant discrepancies, it is concluded that a well-designed beam with elliptic holes will be the most efficient spar regarding weight to rigidity ratio in terms of the bending stress.

  • PDF

정밀전력계의 교정과 시험을 위한 전력표준시스템 (Power Standard System for the Calibration and Test of Precision Power Meters)

  • 박영태;유권상;유광민;장석명
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제51권11호
    • /
    • pp.622-627
    • /
    • 2002
  • The power comparison techniques have implemented power measurements, in which a power comparator is used to balance ac against a dc power obtained from known values. The developed power standard system using the comparison techniques consists of dc sources, ac source, control switches, resistive voltage dividers, resistive shunts and a power comparator. The total uncertainty of the power standard system was proved by analysis of the component instruments. Its expanded(k=2) uncertainty is evaluated to be less than 30 uW/VA at unit power factor and 42 uW/VA at power factor 0.5

풍력발전단지의 예측이용율과 실제이용율 비교분석에 관한 연구 (Comparison between Expected and Actual Capacity Factors of a Wind Farm)

  • 고병욱;문승재;유호선
    • 플랜트 저널
    • /
    • 제7권1호
    • /
    • pp.40-48
    • /
    • 2011
  • This study shows the comparison between expected and actual capacity factors of a wind farm through wind resource analyzation. The expected capacity factor comes from an 'automatic weather system' run by the Korean national weather service and a 'meteorological mast' run by a project owner. Based on this comparison and analysis, the importance of meteorological mast micro-siting and selection of wind turbine class and type, will be studied along with presenting important implications for wind farm expansion and development.

  • PDF

Comparison of Three Antibiotic Susceptibility Tests for Viridans Group Streptococci

  • Kim, Yeon-Hee;Lee, Si-Young
    • International Journal of Oral Biology
    • /
    • 제36권4호
    • /
    • pp.163-166
    • /
    • 2011
  • Oral viridans streptococci are recognized as one of the etiological agents of a variety of infectious diseases such as dental caries and infective endocarditis. Although antimicrobial susceptibility tests for these fastidious bacterial species are now established and standardized, a comparison between the broth microdilution and broth macrodilution tests has not previously been performed. This comparison was performed in the present study using the tests adopted by the Clinical and Laboratory Standards Institute (CLSI) and seven clinical isolates of oral viridans streptococcal strains. A modified broth macrodilution susceptibility test method was also included in this analysis, in which the media was not supplemented with horse blood. The susceptibility interpretation category agreements were measured at 83% (broth microdilution versus broth macrodilution) and 71% (broth microdilution versus modified broth macrodilution). The interpretation category agreement between the broth macrodilution and modified broth macrodilution tests was also 83%. These data indicate that the interpretation of antibiotic susceptibility test results for oral viridans streptococci are influenced by the methods used.

한전 계통의 안정 해석을 위한 계통 등가화에 관한 연구 (Dynamic Equivalents of the KEPCO System for the stability Analysis)

  • 이한민;이병준;권세혁;노규민;장병훈
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제50권1호
    • /
    • pp.6-12
    • /
    • 2001
  • This paper deals with the development of dynamic equivalents of the Korea Electric Corporation (KEPCO) systems. The weak coupling method is chosen for the most suitable coherency identification to represent the characteristics of the KEPCO system by the dynamic characteristic comparison of several coherency identification methods. Also, this paper shows the detail aggregation of generator groups makes a better representation of the dynamic and static characteristics of the original system than the classical aggregation. The simulation results of the developed KEPCO equivalent system are presented in comparison with the original system to illustrate the validity of the equivalent system are presented in comparison with the original system to illustrate the validity of the equivalent system.

  • PDF

Analysis and Comparison of Usability Models and Techniques Measuring User Performance Interacting with Websites

  • Abdulhak, Sami Abduljalil;Kang, Dae-Ki
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2011년도 추계학술대회
    • /
    • pp.210-212
    • /
    • 2011
  • Human Computer Interaction is rapidly growing in different aspects and areas. One of the areas that grab many scholars and researchers interest is usability. Usability is a main factor and critical pillar of products success and acceptance. In this paper, we deeply analyze the current usability models that measure the user performance during the interaction with products. Then, we fairly compare between each model to discover and present the strength and weakness of each model for supporting developer and business organization with guidelines during the development process of the products before launching the actual and final one. Decomposing comparison between each model is performed based on specific criteria. Comparison is tabulated, graphically depicted, and analytically decomposed.

  • PDF

단상 SRM용 컨버터 특성비교 (Comparison of Converter Topologies for Single Phase Switched Reluctance Motor)

  • 김태형;석승훈;;이동희;안진우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 춘계학술대회 논문집 에너지변화시스템부문
    • /
    • pp.139-142
    • /
    • 2009
  • Comparison of three converter topologies for single phase switched reluctance motor is proposed in this paper. Due to the limitation of do-link voltage, conventional asymmetric converter is difficult to build up enough phase current in the high speed operation. In order to solve this problem, boost converter is used to improve the performance. Two active boost converters are reviewed: one is series-connected type, another is parallel-connected. Otherwise, a novel active boost converter is proposed. The comparison of these converters is based on the voltage raring of capacitor, stability and converter topology. Because the converter selection depends on the motor design, the single phase 6/6 SRM is considered in this paper. Some simulations results are executed. And the results verified the analysis in this paper.

  • PDF