• Title/Summary/Keyword: Compact cable

Search Result 41, Processing Time 0.029 seconds

The effects of congestion cost reduction by the application of Superconducting cable (초전도케이블에 의한 전력계통의 혼잡비용 저감 효과)

  • Kim, Hyun-Houng;Lee, Geun-Jun
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.66-68
    • /
    • 2005
  • In Korea power system, the transfer capability of transmission line is limited by the voltage stability and it is difficult to construct new iron tower due to incremental interest for environmental problem and construction costs. Recently, HTS cable could be one of the countermeasures to solve the transfer limit because of it is transported to large power with compact size However, the characteristic of HTS cable have a various problem. This paper presents the effects of congestion cost reduction by the application of HTS (High-Temperature Superconducting) cable. In this paper, the transmission ability before and after application of HTS cable are examined in a viewpoint for voltage stability. therefore, the effects of congestion cost reduction by HTS cable.

  • PDF

Insulation Test for the 22.9 kV Class HTS Power Transmission Cable

  • J.W. Cho;Kim, H.J.;K.C. Seong;H.M. Jang;Kim, D.W.;Kim, S.H.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.5 no.3
    • /
    • pp.48-51
    • /
    • 2003
  • HTS power transmission cable is expected to transport large electric power with a compact size. We are developing a 3-core, 22.9 kV, 50 MVA class HTS power cable, and each core consists of a conductor and shield wound with Bi-2223 tapes, electrical insulation with laminated polypropylene paper (LPP) impregnated with liquid nitrogen. This paper describes the design and experimental results of the model cable for the 22.9 kV, 50 MVA class HTS power transmission cable. The model cable was used the SUS tapes instead of HTS tapes because of testing the electrical characteristics only. The model cable was 1.3 m long and electrical insulation thickness was 4.5 mm. The model cable was evaluated the partial discharge (PD), AC and Impulse withstand voltage in liquid nitrogen. The AC and Impulse withstands voltage and PD inception stress was satisfied with the standard of Korea Electric Power Corporation (KEPCO) in the test results. The 3-core 22.9 kV, 50 MVA class HTS power cable has been designed and manufactured based on these experimental results.

Design and Implementation of the Cable Rod Hydraulic Actuator for Robotic Revolute Joints (로봇의 회전관절을 위한 케이블 로드를 갖는 유압 구동기 설계 및 구현)

  • Kim, Jungyeong;Park, Sangdeok;Cho, Jungsan
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.33 no.9
    • /
    • pp.723-730
    • /
    • 2016
  • This paper presents a cable-driven hydraulic actuator named Cable Rod Hydraulic Actuator (CRHA). The cable actuating system is attractive for designing a compact joint in robotic applications since it can be installed remotely from the joint. Recently, cable rods have been used in pneumatic area for inertia reduction. However, designing cable rods in hydraulics is challenging because it is difficult to achieve flexibility and endurance simultaneously under high pressure conditions. In this paper, the cable rod, which consists of a cable and jacket, is proposed to meet both requirements. To design the CRHA, we determined the design parameters, such as cylinder size, and selected the cable rod's material by friction and leakage test. Finally, comparisons experiments about step and frequency responses with conventional hydraulic actuators were performed to assess feasibility for robotic joints, and the results show that the proposed system has good bandwidth and fast response as robotic joints.

Characteristics of 345KV O.F Cable employing PPLP(Polypropylene Laminated Paper) (PPLP 를 이용한 34SKV O.F Cable 의 제특성)

  • Park, J.G.;Kim, J.W.;Lee, E.J.;Kang, S.H.;Yu, I.K.
    • Proceedings of the KIEE Conference
    • /
    • 1989.07a
    • /
    • pp.415-417
    • /
    • 1989
  • In this paper we introduce electrical and mechanical properties of PPLP, an insulation system of Cellulose/Extruded Polypropylene/Cellulose Paper, and characteristics of 345KV O.F cable employing the PPLP. This cable shows dielectric loss less than 50% and has excellent impulse breakdown strength higher than 17%, respectively, compared with those of the conventional cables. Accordingly, a more compact cable with reduced thickness of the insulation layer, which has remarkable profits in economics, has been developed.

  • PDF

Test result of striated HTS compact cables for low AC loss

  • Kim, Y.;Kim, W.S.;Lee, J.K.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.15 no.2
    • /
    • pp.44-47
    • /
    • 2013
  • Large AC loss from the second generation (2G) high temperature superconducting (HTS) wires has been one of the major bottlenecks in power applications with HTS materials. Moreover, the large power applications also require the large current capacity from the HTS wires, which makes them produce larger AC losses. In order to reduce the AC loss from the HTS conductors with large current capacity, an HTS compact cable with some striations on the superconducting layers has been proposed. In this paper, we prepared some sample HTS compact conductors with striations, and measured their magnetization loss from the external magnetic field. We also made some slits on the superconducting layer of the HTS wire by laser cutting to reduce the aspect ratio of the superconducting layers. It would make the low eddy current loss and magnetic decoupling. Finally, the magnetization losses of the sample HTS compact conductors were measured and analyzed.

PD measuring on MV XLPE Calble by Using UWB Antenna (UWB 안테나를 이용한 MV급 전력케이블의 부분방전 측정 연구)

  • Yang, Sang-Hyun;Lim, Kwang-Jin;Lee, Yong-Sung;Park, Noh-Joon;Park, Dae-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.267-268
    • /
    • 2008
  • This paper presents compact low frequency ultra-wide band(UWB) sensor design and studying of the partial discharge diagnosis by sensing electromagnetic pulse emitted from the partial discharge source with new designed UWB sensor. In this study, we designed new type of compact low frequency UWB sensor based on microstrip antenna technology to detect both low frequency and high frequency band of partial discharge signal. And experiments of offline PD testing on in medium voltage (22.9kV) underground cable and mention the comparative results with the traditional HFCT as a reference sensor in the laboratory. In the series of comparative test, the calibration signal injection test provided with conventional IEC 60270 method and high voltage injection testing are included.

  • PDF

Development of Cable for Towed Array Sonar System (예인 음탐기용 케이블 개발)

  • Yang, Seung-Yun;Kim, Jung-Suk;Kim, Chul-Min;Lee, Jin-Hee
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.19 no.5
    • /
    • pp.559-566
    • /
    • 2016
  • Cables for Towed Array Sonar System(TASS) were developed. In order to verify the performance of cables, environmental and operational conditions as well as functional requirements were investigated during design stage. Double armored high and low voltage integrated cable for towed body and two kinds of cables, armored and light weight power and optic hybrid cables for towed array sensor system were developed by modeling and simulation. Customized manufacturing process and test method, such as foam extrusion and dynamic fatigue test were applied to this development. In conclusion, underwater towed hybrid cable with high tensile strength and compact structure were developed.

Reliability Test Recommendations of Transmission Level HTS Power Cable (송전급 초전도케이블 신뢰성평가를 위한 시험방법)

  • Park, J.;Yang, B.;Kang, J.;Cho, J.;Lee, S.;Shim, K.;Kim, S.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.12 no.3
    • /
    • pp.29-33
    • /
    • 2010
  • For last 10 years, there are big progress and many efforts in the development of HTS power equipments by some country including South Korea. Especially HTS cable system is the strongest candidate among them from the viewpoint of applying to real grid, because of the feature of it, compact and large capacity. In South Korea, transmission level 154kV, the world top voltage class, HTS cable system was installed and has been tested in KEPCO Gochang Underground Cable Test Field since the early of 2010 in order to meet test requirements made by KEPCO, the only grid company in South Korea. The type test of it will be completed by October 2010 and subsequently long-term load cycle test will be performed during 6 months. Also in the near future, KEPCO has a plan to demonstrate transmission level HTS cable system in real grid, in order to meet practical requirements and confirm the feasibility of it. This paper says the test plan of transmission level 154kV HTS cable system and the way how to test it.

A Study on Capacity and Voltage Class to supply HTS Power Transmission Cable to Metropolitan Area (고온초전도 케이블의 대도시 계통 적용을 위한 송전용량과 전압계급의 검토)

  • 최상봉;김대경;정성환;성기철;김학만;김태현;김종율
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2002.02a
    • /
    • pp.211-214
    • /
    • 2002
  • It becomes difficult and high in cost to construct new ducts and/or tunnels for power cable in Metropolitan area. This paper presents the possible application of a HTS superconducting power cable for transmitting electric power in metropolitan areas, reflecting its important distinction such as compactness for installation in underground ducts and considerably economical efficiency comparable to present underground cables. In this paper, review of transmission capacity and voltage class of compact HTS cable which should be applied to existing ducts was performed.

  • PDF

Development of ultra high voltage-large capacity O.F cable (초고압 대용량 O.F 케이블의 개발)

  • Kang, S.H.;Lee, K.J.;Kim, C.S.;Choi, Y.H.
    • Proceedings of the KIEE Conference
    • /
    • 1991.07a
    • /
    • pp.265-267
    • /
    • 1991
  • In this paper, we describe the development of 345kv OF cables to contain also the cable employing new insulation paper, PPLP (Poly propylene Laminated paper). The cables all show very excellent properties, especially PPLP cable has less the dielectric loss and better the impulse & A.C strength than the one employing the conventional paper. Therefore, according to use PPLP cable, it seems to be several advantages such as the compact of system, the increasing capacity, and the decreasing energy loss etc.

  • PDF