• Title/Summary/Keyword: Compact Heat exchanger

Search Result 78, Processing Time 0.032 seconds

A Study on Emission Characteristics of Inserting CO Tube (CO튜브 삽입에 따른 오염 물질 배출특성에 관한 연구)

  • Lee, Jae-Park;Kim, Jong-Min;Lee, Seung-Ro;Lee, Chang-Eon
    • Journal of Energy Engineering
    • /
    • v.19 no.3
    • /
    • pp.182-187
    • /
    • 2010
  • This study was the effect of inserting CO tube on $NO_x$ and CO emission characteristics in a compact combustion chamber. In detail, $NO_x$ and CO emission characteristics with changing of distance due to inserting CO tube between a burner and a main heat exchanger were investigated. For this study, the commercial program, FLUENT with GRI 2.11 detail reaction mechanism, was used for the numerical study and a commercial heat exchanger was tested for the experimental study. As results, when the CO tube was inserted between a burner and a main heat exchanger, it was verified that $NO_x$ and CO emissions was decreased simultaneously as CO tube was closed to a burner and the distance between CO tube and a main heat exchanger was increased.

A Study on the Helically Coiled Heat Exchanger of Small Diameter Tubes (극세관 헬리컬 코일형 열교환기에 관한 연구)

  • Kim, Ju-Won;Kim, Jeong-Hun;Kim, Jong-Su
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.11
    • /
    • pp.1492-1499
    • /
    • 2001
  • In order to develop the compact and flexible heat exchangers, we made the helically coiled heat exchangers. They can be manufactured with small diameter copper tubes without the need for fins; inner diameter=1.0 mm, straight tube length=1.5 m. The experiments were carried out with the following conditions; evaporation pressure=0.6 MPa, air velocity=0.7 ∼ 1.7 m/s, and working fluid=R-22. Pressure drop and heat transfer coefficient of heat exchangers were experimented according to the air velocity. The results of heat transfer coefficient show a 35% beneficial increase fur these heat exchangers over the other covered fin-tube heat exchangers. A cooling capacity of about 3 kW was obtained with an air velocity of 1.5 m/s. The distribution header has also been designed fur efficient distribution of refrigerant flow.

Effect of the CO Tube insert for Emission Characteristics in a Compact Combustion Chamber (컴팩트 연소실 내 CO튜브 삽입에 따른 오염물질 배출특성)

  • Lee, Jae-Park;Kim, Jong-Min;Lee, Seung-Ro;Jang, Gi-Hyun;Lee, Chang-Eon
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 2010.04a
    • /
    • pp.66-71
    • /
    • 2010
  • This study was the effect of CO tube insert for NOx and CO emission characteristics in a compact combustion chamber. In detail, NOx and CO emission characteristics with changing of distance due to inserting the CO tube between the burner and the main heat exchanger were investigated. For this study, the commercial program, FLUENT, and the GRI 2.11 detail reaction mechanism were used for the numerical study and a simple model heat exchanger was tested for the experimental study. As results, when the CO tube was inserted between the burner and the main heat exchanger, it was verified the simultaneous NOx and CO reduction method because of increasing the residence time and decreasing the flame temperature.

  • PDF

A Numerical Study for the Heat and Mass Transfer in Silica gel/Water Adsorption Chiller's Adsorber (흡착식 냉동기의 흡착탑에서 열 및 물질전달에 관한 수치적 연구)

  • Kwon, Oh-Kyung;Yun, Jae-Ho;Kim, Joung-Ha;Kim, Yong-Chan;Joo, Young-Ju
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.341-346
    • /
    • 2005
  • Nowadays, adsorption chillers have been receiving considerable attentions as they are energy-saving and environmental1y benign systems. A Fin & tube type heat exchanger in which adsorption/desorption take place is required more compact size. The adsorption chiller is expected to have high energy-efficiency in utilizing the waste heat exhausted from a process. The objectives of this paper are to investigate the effect of fin pitch of fin & tube on the adsorption performance and to develop an optimal design fin & tube heat exchanger in the silica gel/water adsorption chiller. Previous study concluded that optimal particle size selected 0.5mm, type HO silica gel, and fundamental heat transfer & mass transfer experiments carried out. From the numerical results, the adsorption rate for the fin pitch 2.5mm is the highest than that for the fin pitch 5mm, 7.5mm and 10mm. Also cooling water & hot water temperature affect the adsorption rate.

  • PDF

Heat Exchangers for Gas Turbine Cycles and Thermal Management (롤스로이스 기술개발 동향)

  • Stieger, Rory
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.04a
    • /
    • pp.465-465
    • /
    • 2011
  • Rolls-Royce is a global company producing advanced power systems for use on land, at sea and in the air. In order to develop competitive products and services, Rolls-Royce invests in technology, infrastructure and capability with much of the research carried out in a global network of University Technology Centres, such as the UTC in Thermal management at Pusan National University. Heat exchangers and thermal management play a critical role in today's gas turbine engines, maintaining the fuel and oil temperatures within the correct operational range. Future products are likely to place an increased duty on the thermal management system and thus require advances in heat exchanger design, installation and manufacturing. Heat exchangers further have the potential to play a vital role in Advanced Cycle Gas Turbine products. The Intercooled and recuperated WR21 marine gas turbine engine recently entered service with the Royal Navy and is delivering very attractive fuel burn in service. The development of an advanced cycle aero-engine is a significantly greater challenge, requiring better understanding of compact and light weight heat exchanger surfaces, novel installations and ducting systems and may required novel manufacturing techniques to achieve the volume, weight and cost necessary to realise a viable advanced cycle gas turbine aero-engine.

  • PDF

Numerical Analysis of the Heat and Mass Transfer in a Fin Tube Type Adsorber (핀튜브형 흡착탑에서 열 및 물질전달 수치해석)

  • Kwon, Oh Kyung;Chung, Jae Dong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.8
    • /
    • pp.457-463
    • /
    • 2013
  • Nowadays, adsorption chillers have been receiving considerable attention, as they are energy saving and environmentally benign systems. A fin tube type heat exchanger in which adsorption/desorption takes place is required with more compact size. The adsorption chiller is expected to have high energy efficiency in utilizing the waste heat exhausted from a process. The objectives of this paper are to scrutinize the effect of design parameters on the adsorption performance, especially the fin pitch of the fin tube, and to develop an optimal design fin tube heat exchanger in a silica gel/water adsorption chiller. From the numerical results, the fin pitch of 2.5 mm shows the highest adsorption rate, compared to other fin pitches, such as 5 mm, 7.5 mm and 10mm. Also, the adsorption rate is affected by the cooling water and hot water temperature.

Experimental Investigation of Heat Transfer Enhancement in a Circular Duct with Circumferential Fins and Circular Disks

  • Taebeom Seo;Byun, Sang-Won;Jung, Myoung-Ryol
    • Journal of Mechanical Science and Technology
    • /
    • v.14 no.12
    • /
    • pp.1421-1428
    • /
    • 2000
  • The characteristics of heat transfer and pressure drop for fully developed turbulent flow in a tube with circumferential fins and circular were experimentally studied. The various spacing and sizes of circumferential fins and circular disks were selected as design parameters, while the effects of these parameters on heat transfer enhancement and pressure drop were investigated. In order to quantify the effect of heat transfer enhancement and the increase of pressure drop due to the fins and disks in a tube, the Nusselt numbers and the friction factors for various configurations and operating conditions were compared to those for a corresponding smooth tube. The results showed that the heat transfer rate was significantly enhanced by increasing the height of circumferential fins and decreasing the pitch of circumferential fins. On the other hand, the influence of the disk size and the fin-disk spacing were not significant. Based on the experimental results, a correlation for estimating the Nusselt number was suggested.

  • PDF

An Experimental Study on the Performance of Diffusion Bonding Heat Exchangers (확산접합 콤팩트 열교환기의 성능에 관한 실험적 연구)

  • Kwon, Oh-Kyung;Cha, Dong-An;Yun, Jae-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.33 no.1
    • /
    • pp.53-59
    • /
    • 2009
  • The objectives of this paper are to study the characteristics of heat transfer and pressure drop of the micro channel heat exchangers using diffusion bonding technology. Four types of heat exchangers are designed and manufactured, which are straight type, long dot type, splited wavy type and straight double side type. Heat transfer and pressure drop performance of each heat exchangers are measured in various operating conditions, and compared each other. The results show that the $(j/f)^{1/3}$ performance of splited wavy type and long dot type increases about 10.3% and 6.1% at the Reynolds number 470 compared to that of straight type, respectively. On the other hand, $(j/f)^{1/3}$ performance of straight double side type decreases 19.7%.

An Experimental Study on the Performance of Diffusion Bonding Heat Exchangers (확산접합 콤팩트 열교환기의 성능에 관한 실험적 연구)

  • Kwon, Oh-Kyung;Cha, Dong-An;Choi, Mi-Jin;Yun, Jae-Ho
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2304-2309
    • /
    • 2008
  • The objectives of this paper are to study the characteristics of heat transfer and pressure drop of the micro channel heat exchangers using diffusion bonding technology. Four types of heat exchangers are designed and manufactured, which are straight type, long dot type, splited wavy type and straight double side type. Heat transfer and pressure drop performance of each heat exchangers are measured in various operating conditions, and compared each other. The results show that the $(j/f)^{1/3}$ performance of splited wavy type and long dot type increases about 10.3% and 6.1% at the Reynolds number 470 compared to that of straight type, respectively. On the other hand, $(j/f)^{1/3}$ performance of straight double side type decreases 19.7%.

  • PDF

Development of a Compact Nuclear Hydrogen Coupled Components Test Loop (원자로수소생산을 위한 연결부품 실험용 소형 컴팩트 실험장치 개발)

  • Hong, S.D.;Kim, J.H.;Kim, C.S.;Kim, Y.W.;Lee, W.J.
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2850-2855
    • /
    • 2008
  • Very High Temperature Reactor (VHTR) has been selected as a high energy heat source for a nuclear hydrogen generation. The VHTR heat is transferred to a thermo-chemical hydrogen production process through an intermediate loop. Both Process Heat Exchanger and sulfuric acid evaporator provide the coupled components between the VHTR intermediate loop and hydrogen production module. A small scaled Compact Nuclear Hydrogen Coupled Components test loop is developed to simulate the VHTR intermediate loop and hydrogen production module. Main objective of the loop is to screening the candidates of NHDD (Nuclear Hydrogen Development and Demonstration) coupled components. The operating condition of the gas loop is a temperature up to $950^{\circ}C$ and a pressure up to 6.0MPa. The thermal and fluid dynamic design of the loop is dependent on the structures that enclose the gas flow, especially primary side that has fast gas velocity. We designed and constructed a small scale sulfuric acid experimental system which can simulate a part of the hydrogen production module also.

  • PDF