• 제목/요약/키워드: Common-cause failure

검색결과 247건 처리시간 0.03초

Immunogenicity of botulinum toxin

  • Wee, Syeo Young;Park, Eun Soo
    • Archives of Plastic Surgery
    • /
    • 제49권1호
    • /
    • pp.12-18
    • /
    • 2022
  • Botulinum toxin treatment is the most common non-surgical cosmetic treatment. Although there are many available treatments using botulinum toxin, their effects are temporary and repeated injections are required. These frequent injections can trigger an immunological response. In addition, botulinum toxin acts as an antigen in the body; thus, its effect disappears progressively due to this immunological reaction, which may cause treatment failure. Active botulinum toxin consists of a core neurotoxin and complexing proteins, the exact effects of which remain unclear. However, the complexing proteins are closely related to the immune response and the formation of neutralizing antibodies. Since neutralizing antibodies can lead to treatment failure, their formation should be prevented. Furthermore, various methods of detecting neutralizing antibodies have been used to predict treatment failure.

흉부손상 76례에 대한 임상적 관찰 (A clinical evaluation of 76 chest injuries)

  • 윤갑진
    • Journal of Chest Surgery
    • /
    • 제17권1호
    • /
    • pp.110-117
    • /
    • 1984
  • A clinical evaluation was performed on 76 cases of chest injury experienced at department of Chest Surgery, Capital Armed Forces General Hospital during the past 3 years period from January 1981 to August 1983. 1.The most common cause of the chest trauma was gun shot by which 26 cases were injured among 44 cases [57.9%] of penetrating injury. Remaining 32 cases [42.1%] were injured by non-penetrating blunt trauma. 2.Hemopneumothorax was observed in 60 cases [78.9%], those were caused by both penetrating [65%] and non-penetrating [35%] injuries. 3.Rib fracture was found in 58.7% of total cases and with rib fracture, clavicle fracture was combined at 19.6% and sternal fracture, at 8.7%. 4.Most common symptoms were chest pain and dyspnea, and most common signs were breath sound diminution and subcutaneous emphysema. 5.Common site of rib fracture was from 4th rib to 8th rib [69.4%]. 6.In 58 cases [76.3%], patients were treated with operation including open thoracotomy [25 cases]. 7.Overall mortality was 5.3%[4 cases] and causes of death were septic shock and respiratory failure.

  • PDF

식물 제제와 연관된 급성 독성 간염으로 인한 간이식 : 원인 제제와 손상 유형에 대한 후향적 분석 (Liver Transplantation for Acute Toxic Hepatitis due to Herbal Medicines and Preparations)

  • 손창환;차명일;오범진;여운형;이재호;김원;임경수
    • 대한임상독성학회지
    • /
    • 제6권2호
    • /
    • pp.110-116
    • /
    • 2008
  • Purpose: Acute toxic hepatitis is a common cause of acute liver failure (ALF). We investigated the causes, clinical manifestation, and outcomes of ALF patients who underwent liver transplantation due to acute toxic hepatitis caused by herbal medicines and preparations. Methods: Between January 1992 and May 2008, we retrospectively reviewed the medical records of 24 patients who were transplanted due to acute toxic hepatitis caused by herbal medicines and preparations. We applied the RUCAM score to patients with acute toxic hepatitis and assessed the relationship between herbal preparations and liver injury. We studied the patients' medication history, liver function tests, and clinical outcomes. Results: The type of liver injury was divided into three groups: hepatocellular type, 14 patients (58.3%); cholestatic type, 4 patients (16.7%); and mixed type, 6 patients (25%). Polygonum multiflorum Thunberg (3 cases) was the most common cause of acute toxic hepatitis, followed by Acanthopanax senticosus (2 cases), pumpkin juice (2 cases), Dictamnus dasycarpus Turcz (2 cases), Hovenia dulcis (1 case), Phellinus linteus (1 case), and Artemisia capillaries (1 case). One year survival after liver transplantation was 76%. Conclusion: We identified the herbal preparations leading to acute liver failure. Many patients consider herbal remedies to be completely free of unwanted side effects. However, we found that many herbal products have biological activities that can lead to severe hepatotoxicity.

  • PDF

체중 10kg이하 심실중격결손증 환아의 임상적 고찰 (A Clinical Analysis of Ventricular Septal Defect Infants Weighting Less Than 10kg of Body Weght)

  • 손제문
    • Journal of Chest Surgery
    • /
    • 제27권8호
    • /
    • pp.650-655
    • /
    • 1994
  • The author analyzed 99patients with VSD weighting less than 10kg of body weight who underwent surgical correction from 1981 to 1992 at cardiovascular department of Hanyang University hospital. Patients occupied 29.3% of total cases who were underwent surgical corrections for congenital heart diseases during that time. Of the 99 patients, 51 patients were male [52%] and 48 patients[48%] were female. Age ranged from 28 days to 36 months with mean age of 13.6 months. Mean body weight was 7.53kg. According to Kirklin`s anatomical classification, type II defect was most common [61.6%]. Associated anomaly was found in 48 patients [48.5%]. Patent foramen ovale was most commonly associated cardiac anomaly [14.1%] and followed by atrial septal defect [12.1%], patent ductus arteriosus [10.1%]. Cardiac catheterization data were analyzed. The most common range of Qp/Qs, Rp/Rs, Pp/Ps were above 3.0, 0.1 - 0.25, and above 0.75 respectively. Among the indications of surgical correction, there were pulmonary hypertention in 69 patients, congestive heart failure in 44 patients, frequent respiratory infection in 47 patients, growth retardation in 33 patients. The most common surgical approach and method for VSD closure were right atriotomy[48.3%] and dacron patch closure[93.3%]. Complication rate was 13.1% [13 cases], and overall mortality was 17.1% [17 cases]. The cause of death consisted of low cardiac output syndrome[11 cases], acute renal failure[3 cases], sepsis[2 cases] and pulmonary insufficiency[1 case] in order of frequency.

  • PDF

흉부 손상의 임상적 고찰 (Clinical Evaluation of Chest Trauma)

  • 김용한
    • Journal of Chest Surgery
    • /
    • 제25권9호
    • /
    • pp.968-975
    • /
    • 1992
  • A clinical analysis was performed on 404 cases of the chest trauma who were admitted and treated at department of thoracic and cardiovascular surgery, Chung Ang University, Yong San Hospital during the past 8 years from July 1984 to April 1992. The results were as follows. 1. The sex ratio was 3: 1 with male predominence. 2. The common age groups were 3rd, 4th, 5th and 6th decades. 3. The most common chief complaint was chest pain[58.2%]. 4. Of 404 cases of chest trauma, 50 cases were resulted from penetrating injuries whereas 354 cases were from non penetrating injuries. The most common cause of the non penetrating injuries was traffic accident[234/354, 66.1%] and of the penetrating injuries were stab wound[47/50, 94%]. 5. The left thorax was the preferred site of chest trauma. 6. The range of hospital stay was from less than 1 week to over 6 weeks and the average duration was about 2 weeks. 7. The common chest trauma was rib fracture[51.6%] and others were simple contusion [18.8%], hemothorax[14.6%], hemopneumothorax[14.9%] and pneumothorax[8.7i]. The rib fracture was prevalent between 4th to 9th rib laterally. 8. There were 92 cases of associated injuries which were bone fracture[66/92, 71.7%], head injury[17/92, 18.5%] and abdominal injury[9/92, 9.8%]. 9. The methods of treatment were conservative management[58.6%], closed tho-racostomy[23.3%], open thoracotomy[3.4%] and others. 10. There were 28 cases[6.9%] of complication, such as pneumonia, atelectasis, emp-yema, respiratory failure and others. 11. The overall mortality was 2.5%[10 cases] and causes of death were hypovolemic shock, acute renal failure, adult respiratory distress syndrome, sepsis and multiple organ failure.

  • PDF

Simplified Machine Diagnosis Techniques Using ARMA Model of Absolute Deterioration Factor with Weight

  • Takeyasu, Kazuhiro;Ishii, Yasuo
    • Industrial Engineering and Management Systems
    • /
    • 제8권4호
    • /
    • pp.247-256
    • /
    • 2009
  • In mass production industries such as steel making that have large equipment, sudden stops of production process due to machine failure can cause severe problems. To prevent such situations, machine diagnosis techniques play important roles. Many methods have been developed focusing on this subject. In this paper, we propose a method for the early detection of the failure on rotating machine, which is the most common theme in the machine failure detection field. A simplified method of calculating autocorrelation function is introduced and is utilized for ARMA model identification. Furthermore, an absolute deterioration factor such as Bicoherence is introduced. Machine diagnosis can be executed by this simplified calculation method of system parameter distance with weight. Proposed method proved to be a practical index for machine diagnosis by numerical examples.

A Safety Assessment Methodology for a Digital Reactor Protection System

  • Lee Dong-Young;Choi Jong-Gyun;Lyou Joon
    • International Journal of Control, Automation, and Systems
    • /
    • 제4권1호
    • /
    • pp.105-112
    • /
    • 2006
  • The main function of a reactor protection system is to maintain the reactor core integrity and the reactor coolant system pressure boundary. Generally, the reactor protection system adopts the 2-out-of-m redundant architecture to assure a reliable operation. This paper describes the safety assessment of a digital reactor protection system using the fault tree analysis technique. The fault tree technique can be expressed in terms of combinations of the basic event failures such as the random hardware failures, common cause failures, operator errors, and the fault tolerance mechanisms implemented in the reactor protection system. In this paper, a prediction method of the hardware failure rate is suggested for a digital reactor protection system, and applied to the reactor protection system being developed in Korea to identify design weak points from a safety point of view.

ESD에 의한 반도체소자의 손상특성 (Damage and Failure Characteristics of Semiconductor Devices by ESD)

  • 김두현;김상렬
    • 한국안전학회지
    • /
    • 제15권4호
    • /
    • pp.62-68
    • /
    • 2000
  • Static electricity in electronics manufacturing plants causes the economic loss, yet it is one of the least understood and least recognized effects haunting the industry today. Today's challenge in semiconductor devices is to achieve greater functional density pattern and to miniaturize electronic systems of being more fragile by electrostatic discharges(ESD) phenomena. As the use of automatic handling equipment for static-sensitive semiconductor components is rapidly increased, most manufacturers need to be more alert to the problem of ESD. One of the most common causes of electrostatic damage is the direct transfer of electrostatic charge from the human body or a charged material to the static-sensitive devices. To evaluate the ESD hazards by charged human body and devices, in this paper, characteristics of electrostatic attenuation in domestic semiconductor devices is investigated and the voltage to cause electronic component failures is investigated by field-induced charged device model(FCDM) tester. The FCDM simulator provides a fast and inexpensive test that faithfully represents ESD hazards in plants. Also the results obtained in this paper can be used for the prevention of semiconductor failure from ESD hazards.

  • PDF

자동차 워셔펌프의 통기구 유무에 따른 작동내구 특성 분석 (Analysis Study on Durability Properties of Washer Pump with Vent Hole)

  • 이상훈;위신환;김성우;김규로
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제13권1호
    • /
    • pp.45-53
    • /
    • 2013
  • In this paper, we analyze the failure mechanism of the washer pump to find what is the failure cause in the road environment. The statistics show the field common failure mode is inner corrosion. The failure mechanism is assumed that the inner part of washer pump is corroded due to inflow of moisture through vent hole. To prevent the failure, we can think a method that is covering the vent hole. In general, the vent hole is designed to play an important role in an automobile parts. So, we need to prove the vent hole is not necessary. The first purpose of this paper is to make sure that the vent hole does not affect the durability of washer pump using the analysis of operating condition. The second purpose is to compare the durability properties if the vent hole is covered.

Analysis of failed mechanical thrombectomy with a focus on technical reasons: Ten years of experience in a single institution

  • Sinho Park;Dong Hoon Lee;Jae Hoon Sung;Seung Yoon Song
    • Journal of Cerebrovascular and Endovascular Neurosurgery
    • /
    • 제25권1호
    • /
    • pp.13-18
    • /
    • 2023
  • Objective: Mechanical thrombectomy (MT) is an effective treatment for patients suffering from acute ischemic stroke secondary to large vessel occlusion. However, recanalization failure rates of interventions were about 20% in literature studies. We report our experience of unsuccessful MT with a focus on technical reasons. Methods: From December 2010 to June 2021, six hundred eight patients with acute ischemic stroke due to large artery occlusion received MT using a stent retriever with or without an aspiration catheter in our institution. We divided the reasons for failure into six categories. We analyzed the reasons for failure by dividing our experience time into 3 periods. Results: A total of 608 cases of thrombectomy for large vessel occlusion were identified in the study period. The successful recanalization rate was 90.4%. In most of the cases (20/57, 35%), the thrombus persisted despite several passes, and the second most common cause was termination of the procedure even after partial recanalization (10/57, 18%). Similar proportions of in-stent occlusion, distal embolization, and termination due to vessel rupture were observed. On analysis of three periods, the successful recanalization rate improved over time. Conclusions: MT fails due to various reasons, and intracranial artery stenosis is the main cause of MT failure. With the development of rescue techniques, the failure rate has gradually decreased. Further development of new devices and techniques could improve the recanalization rates.