• 제목/요약/키워드: Common-cause failure

Search Result 247, Processing Time 0.036 seconds

Reoperation for prosthetic valve failure -clinical analysis of 15 cases- (인공심방판막실패에 대한 임상적 고찰)

  • 권오춘
    • Journal of Chest Surgery
    • /
    • v.19 no.4
    • /
    • pp.584-594
    • /
    • 1986
  • Despite the multivariate improvements in tissue treatment, material, and design of prosthetic heart valves in recent years, numerous complications that may lead to valve dysfunction remain a constant threat after valve replacement. Most common indications for prosthetic valve failure are primary valve failure, infective endocarditis, paravalvular leakage, and thromboembolism. From 1977 to 1986, 15 patients underwent reoperation for prosthetic valve failure in 278 cases of valve surgery. The etiology of prosthetic valve failure were primary valve failure in 12 patients [80 %], infective endocarditis in 2 patients [13.3 %], and a paravalvular leakage [6.7 %]. The average durations of implantation were 45.5 months; 53.9 months in primary valve failure, 16 months in infective endocarditis, and 4 months in paravalvular leakage. The rate of valve failure was high under age of 30 [11/15]. Calcifications and collagen disruption of prosthesis were main cause of primary valve failure in macro- & micropathology. Prosthesis used in reoperation were 5 tissue valves and 10 mechanical valves. Operative mortality were 13.3 % [2/15], due to intractable endocarditis and ventricular arrhythmia.

  • PDF

Adverse Events in Total Artificial Heart for End-Stage Heart Failure: Insight From the Food and Drug Administration Manufacturer and User Facility Device Experience (MAUDE)

  • Min Choon Tan;Yong Hao Yeo;Jia Wei Tham;Jian Liang Tan;Hee Kong Fong;Bryan E-Xin Tan;Kwan S Lee;Justin Z Lee
    • International Journal of Heart Failure
    • /
    • v.6 no.2
    • /
    • pp.76-81
    • /
    • 2024
  • Background and Objectives: Real-world clinical data, outside of clinical trials and expert centers, on adverse events related to the use of SyncCardia total artificial heart (TAH) remain limited. We aim to analyze adverse events related to the use of SynCardia TAH reported to the Food and Drug Administration (FDA)'s Manufacturers and User Defined Experience (MAUDE) database. Methods: We reviewed the FDA's MAUDE database for any adverse events involving the use of SynCardia TAH from 1/01/2012 to 9/30/2020. All the events were independently reviewed by three physicians. Results: A total of 1,512 adverse events were identified in 453 "injury and death" reports in the MAUDE database. The most common adverse events reported were infection (20.2%) and device malfunction (20.1%). These were followed by bleeding events (16.5%), respiratory failure (10.1%), cerebrovascular accident (CVA)/other neurological dysfunction (8.7%), renal dysfunction (7.5%), hepatic dysfunction (2.2%), thromboembolic events (1.8%), pericardial effusion (1.8%), and hemolysis (1%). Death was reported in 49.4% of all the reported cases (n=224/453). The most common cause of death was multiorgan failure (n=73, 32.6%), followed by CVA/other non-specific neurological dysfunction (n=44, 19.7%), sepsis (n=24, 10.7%), withdrawal of support (n=20, 8.9%), device malfunction (n=11, 4.9%), bleeding (n=7, 3.1%), respiratory failure (n=7, 3.1%), gastrointestinal disorder (n=6, 2.7%), and cardiomyopathy (n=3, 1.3%). Conclusions: Infection was the most common adverse event following the implantation of TAH. Most of the deaths reported were due to multiorgan failure. Early recognition and management of any possible adverse events after the TAH implantation are essential to improve the procedural outcome and patient survival.

Case Study of Intermittent Poor Acceleration Fault Diagnosis by Brake Switch Fault (브레이크 스위치 결함에 의한 간헐적인 가속불량 현상의 고장진단 사례연구)

  • Kim, Sung Mo;Jo, Haeng Deug
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.24 no.2
    • /
    • pp.203-210
    • /
    • 2015
  • This paper investigates the failure of a car with a 2.5-liter CRDi engine of the Hyundai Company. The failure is caused by intermittent poor acceleration while driving. To analyze the cause, we investigated the air intake volume, the fuel injection, and the air-fuel ratio, which were determined to be normal. The brake switch signal error was discovered while analyzing the function that limits the output of the engine. While investigating the cause, we discovered the corrosion of the pins on the connector of the brake switch. We determined that it was generated by soapy water flowing in the solar film. Therefore, the cause of the failure was the brake switch signal errors. Additionally, we determined that ECM was the normal fail-safe mode that implemented the override device for safety during normal acceleration. Based on these results, further solar film experiments must be conducted to fully elucidate the causes.

Reliability Analysis on Firewater Supply Facilities based on the Probability Theory with Considering Common Cause Failures (소방수 공급설비에 대한 공통원인고장을 고려한 확률론적 신뢰도 분석)

  • Ko, Jae-Sun;Kim, Hyo
    • Fire Science and Engineering
    • /
    • v.17 no.4
    • /
    • pp.76-85
    • /
    • 2003
  • In this study, we write down the definitions, their causes and the techniques of analysis as a theoretical consideration of common cause failures, and investigate the limitation and the importance of the common cause failures by applying to the analysis on the fire protection as a representative safety facility. As you can know in the reliability analysis, most impressive cause is the malfunctions of pumping operations; especially the common cause failure of two pumps is dominant. In other words, it is possible to assess system-reliability as twice as actual without CCF From these, CCF is extraordinarily important and the results are highly dependent on the CCF factor. And although it would increase with multiple installations, the reliability are not defined as linear with those multiplications. In addition, the differences in results due to the models for analysis are not significant, whereas the various sources of data produce highly different results. Therefore, we conclude that the reliabilities are dependent on the quality of the usable data much better than the variety of models. As a result, the basic and engineering device for the preventions of CCF of the multiple facilities is to design it as reliably as to design the fire-water pump. That is to say, we must assess those reliabilities using PFD whether they are appropriate to SIL (Safety Integrity Level) which is required for the reliability in SIS (Safety Instrumented System). The result of the analysis on the reliability of the fire-water supply with CCF shows that PFD is 3.80E-3, so that it cannot be said to be designed as safely as in the level of SIL5. However, without CCF, PFD is 1.82E-3 which means that they are designed as unsafely as before.

A rapid modeling method and accuracy criteria for common-cause failures in Risk Monitor PSA model

  • Zhang, Bing;Chen, Shanqi;Lin, Zhixian;Wang, Shaoxuan;Wang, Zhen;Ge, Daochuan;Guo, Dingqing;Lin, Jian;Wang, Fang;Wang, Jin
    • Nuclear Engineering and Technology
    • /
    • v.53 no.1
    • /
    • pp.103-110
    • /
    • 2021
  • In the development of a Risk Monitor probabilistic safety assessment (PSA) model from the basic PSA model of a nuclear power plant, the modeling of common-cause failure (CCF) is very important. At present, some approximate modeling methods are widely used, but there lacks criterion of modeling accuracy and error analysis. In this paper, aiming at ensuring the accuracy of risk assessment and minimizing the Risk Monitor PSA models size, we present three basic issues of CCF model resulted from the changes of a nuclear power plant configuration, put forward corresponding modeling methods, and derive accuracy criteria of CCF modeling based on minimum cut sets and risk indicators according to the requirements of risk monitoring. Finally, a nuclear power plant Risk Monitor PSA model is taken as an example to demonstrate the effectiveness of the proposed modeling method and accuracy criteria, and the application scope of the idea of this paper is also discussed.

Categorization of Motor Operated Valve Safety Significance for Its Periodic Safety Verification (모터구동 밸브 주기적 안전성 확인을 위한 중요도 분류)

  • Sung, Tae-Young;Kim, Kil-Yoo;Kang, Dae-Il
    • Journal of the Korean Society of Safety
    • /
    • v.17 no.2
    • /
    • pp.92-99
    • /
    • 2002
  • Safety-related motor operated valve(MOV) safety significance for Ulchin Unit 3 was categorized. The safety evaluation of MOV of domestic nuclear power plants affects the generic data used for the quantification of MOV common cause failure(CCF) events in Ulchin Units 3&4 PSA. Therefore, in this paper, MGL(multiple greek letter)parameter ${\beta}$, used for the evaluation of MOV CCF probabilities in Ulchin Units 3&4 probabilistic safety assessment(PSA), was re-estimated and the MOV safety significance was categorized. The re-estimation results of MGL parameter show that the value of(is decreased by 30% compared with the current value used in Ulchin Unit 3&4 PSA. The categorization results of MOV safety significance using the changed value of MGL parameter(show that the number of HSSCs(high safety significant components) is decreased by 54.5% compared with those using the current value of it used in Ulchin Units 3&4 PSA.

Nutritional approach to failure to thrive

  • Jeong, Su-Jin
    • Clinical and Experimental Pediatrics
    • /
    • v.54 no.7
    • /
    • pp.277-281
    • /
    • 2011
  • Failure to thrive (FTT) is a term generally used to describe an infant or child whose current weight or rate of weight gains is significantly below that expected of similar children of the same age, sex and ethnicity. It usually describes infants in whom linear growth and head circumference are either not affected, or are affected to a lesser degree than weight. FTT is a common problem, usually recognized within the first 1-2 years of life, but may present at any time in childhood. Most cases of failure to thrive involve inadequate caloric intake caused by behavioral or psychosocial issues. The most important part of the outpatient evaluation is obtaining an accurate account of a child's eating habits and caloric intake. Routine laboratory testing rarely identifies a cause and is not generally recommended. FTT, its evaluation, and its therapeutic interventions are best approached by a multi-disciplinary team includes a nutritionist, a physical therapist, a psychologist and a gastroenterologist. Long term sequelae involving all areas of growth, behavior and development may be seen in children suffering from FTT. Early detection and early intervention by a multidisciplinary team will minimize its long term disadvantage. Appropriate nutritional counseling and anticipatory guidance at each well child visit may help prevent some cause of FTT.

Angiodysplasia in a Child with Chronic Renal Failure: Endoscopic Hemostatic Therapy (소아 만성 신부전 환자에서 발생한 위혈관 이형성증의 Hemoclipping에 의한 지혈 치료 1례)

  • Lee, Yun-Jin;Kim, Young-Mi;Kim, Su-Young;Park, Jae-Hong
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.6 no.2
    • /
    • pp.192-196
    • /
    • 2003
  • Angiodysplasia is the most common vascular abnormality of the gastrointestinal tract and probably the most frequent cause of recurrent lower intestinal bleeding in otherwise healthy elderly patients. Also, it is an important cause of hemorrhage in chronic renal failure observed in up to 19~32% of patients. Bleeding due to gastric angiodysplasia is treated by various endoscopic approaches, including argon and Nd : YAG laser photocoagulation, monopolar or bipolar electrocoagulation, heater probe, injection sclerotherapy, band ligation or hemoclipping. A 15-year-old boy, who had undergone hemodialysis for chronic renal failure for about 10 years, was admitted due to melena and progressive anemia. A gastroduodenoscopy revealed a cherry red and fern-like lesion with oozing on the posterior wall at junction of gastric body and fundus. Endoscopic hemoclipping therapy was performed. However, melena recurred four days later. Argon plasma coagulation and hemoclipping therapy were performed again. Since then, no recurrence of bleeding has been observed.

  • PDF

Laparoscopic Surgery for Intussusception in Children (소아 장중첩증에 대한 복강경 수술의 경험)

  • Yoon, Doo Hwan;Nam, So-Hyun
    • Advances in pediatric surgery
    • /
    • v.19 no.2
    • /
    • pp.66-72
    • /
    • 2013
  • Intussusception is common cause of intestinal obstruction in children. Most of intussusceptions can be treated with non-operative reduction using air or barium. However, about 10% patients need operative treatment due to failure of reduction, peritonitis, and recurrence after reduction. We introduce our experience of laparoscopic surgery for intussusception. From April 2010 to March 2013, we reviewed 57 children who diagnosed intussusception. Twelve patients underwent an operation. The cause of operation was 7 of failure of air reduction and 5 of recurrence after air reduction. Median age was 21.5 months (range: 5.0~57.7 months) and 11 children (91.7%) underwent successful laparoscopic reduction. Median operating time was 50 minutes (range: 30~20 minutes) and median hospital days was 4.5 days (range: 3~8 days). One patient had a leading point as a heterotopic pancreas and underwent bowel resection through conversion. There was neither intra-operative nor postoperative complication. Laparoscopic reduction for intussusception can bring an excellent cosmetic effect with high success rate.

Studies on the Acute Toxicity and Histological Changes in Fish Exposed to Furrural (Furfural 어류급성독성 및 조직병리에 관한 연구)

  • 이철우;최성수;최필선;이상협;이길철;박광식
    • Environmental Analysis Health and Toxicology
    • /
    • v.12 no.3_4
    • /
    • pp.55-59
    • /
    • 1997
  • Furfural, an organic solvent, is widely used as synthetic component material in producing chemical products. However, furfural has been reported that it shows strong toxicities to human being showing intense stimulus to skin, eyes, mucous membrane and nerve system. It is also known to cause anemia, liver cirrhosis, kidney failure and genetic toxicity in the human being working in the exposed area. LD$_{50}$ of furfural for peritoneal injected mouse has been known around 20mg/kg, but the acute toxicity on aquatic organisms such as fish, daphnid or algae are not well known, compared to those on rodents. In this experiment, we studied on the fish toxicity of furfural using Japanese Medaka (Orvzias latipes) and Common Carp (Cvprinus carpio). We also observed histological changes in the fish organs. The LC$_{50}$ were 12. Smg/L in Japanese Medaka and 21.8 mg/L in Common Carp, respectively. When Common Carps were exposed to 120mg/L of furfural concentration for 30 minutes, blood congestion in gills and lysis of secondary lamella were shown. Though the muscle of caudal fin was not completely eroded, its epidermic cells were shown to be necrotic in various parts. Tissue atrophy and cell necrosis were also shown in the liver of Common Carps exposed to furfural. From these results, furfural seems to cause histological damages on liver, an internal organ as well as on external organs such as gills and fins eventhough the fish were exposed for a short-term.

  • PDF