• Title/Summary/Keyword: Common grounding

Search Result 64, Processing Time 0.034 seconds

A study on aerological disorders and performance evaluation of Korean air force pilots (한국 공군 조종사의 직업성 질환 실태 및 임무 수행도에 관한 연구)

  • 변승남;김철수;이동훈
    • Journal of the Ergonomics Society of Korea
    • /
    • v.15 no.2
    • /
    • pp.25-36
    • /
    • 1996
  • The purposes of the present study were: (1) to investigate aeromedical dissorders prevalent among ROK air force pilots and (2) to evaluate their detrimental effects on flight performance. The study examined the eight flight-induced disorders primarily responsible for permanent grounding and flying restrictions. According to the survey of 600 randomly selected pilots, 80.2% of the respondents have experienced low back pain, which was 20% higher than the lifetime prevalence in Swedish male workers. Bradyacusia ranked second (56.0%) resulting from continuous exposure to high aircraft noise. The cardiovascular disorders, the most common cause for permanent grounding of Canadian forces pilots, were found in 16.0% of the Korean pilots. Due to the high prevalence of the disorders, in 1993 the Korean pilots received medical treatments 10 times as many as factory workdes. Compared to the flight performance of Israeli and British pilots in wars, the flight performance of the Korean pilots was found to be inferior. Such poor performance can be attributable to the high incidence rates of disorders. Statistical analyses revealed that the aeromedical disorders were related to personal variables such as age, flight career- related factors, and fatigue. Cigarette smoking and drinking habit contributed to worsening back pain, barotitis media, and pulmonary disorders. More comprehensive research was recommended to identify health hazards, combined with intervention to minimize disorders that could lead to early termination of flight careers or excessive loss of flight time. This study further suggests that aeromedical institutions in Korean air force should be fostered more professionally and financially.

  • PDF

An Effective Installation Method of Lightning Protective Devices for Information and Communication Facilities (정보통신설비에 대한 뇌서지 보호소자의 효과적인 설치기법)

  • Lee, B.H.;Kang, S.M.;Eom, J.H.;Lee, D.M.;Lee, S.B.;Jeong, D.C.;Ahn, C.H.;Jeon, D.K.;Lee, K.O.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1754-1756
    • /
    • 2002
  • This paper deals with an effective installation method of lightning protective devices for information and communication facilities. Due to the potential difference between grounding of the AC power lines and communication lines, the equipments connected to the communication lines are easily damaged by lightning surges. So we have examined the behaviors of surge protective devices against lightning surges from the AC power lines and signal lines, and the coordination effects of SPD installation method were investigated. As a result, it was confirmed that the bypass arrester method and common grounding method were very effected.

  • PDF

An Effective Installation Method of lightning Protective Devices for Information and Communication Facilities (정보통신설비용 뇌서지 보호장치의 효과적인 설치기법)

  • 이복희;이동문;강성만;엄주홍;이승칠
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.5
    • /
    • pp.90-96
    • /
    • 2002
  • The AC power lines and signal lines of info-communication networks are muted on overhead poles and are exposed to lightning strikes. Due to the potential difference between groundings of the AC power lines and telecommunication lines, the electronic equipments connected to the telecommunication lines can easily be damaged by lightning surges. In this work, in order to develop the reliable ways to protect information and communication facilities from lightning surges, the reliability and performance of surge protective devices were experimentally investigated in actual-sized test circuit. The operation behaviors of surge protective devices against lightning surges from the AC power lines and telecommunication lines and the coordination effects of SPD installation method were evaluated. As a consequence, it was confirmed that the bypass arrester and common grounding system is very effective.

A Study on the Safety Grounding for Prevention of Electric Shock Hazard in Construction of Industrial Plant in Maritime Landfill Area (해상 매립 지역 산업 플랜트 건설 시 감전 재해 예방을 위한 안전 접지에 관한 연구)

  • Kim, Hong-Yong;Jang, Ung-Burm
    • Journal of the Society of Disaster Information
    • /
    • v.13 no.3
    • /
    • pp.305-312
    • /
    • 2017
  • In our society, the advanced, advanced, and information industries have continued to grow and now live in the era of the fourth industrial revolution. As the industry develops, the load of the users has also increased so much that it is deepened by the energy shortage phenomenon and the construction of additional energy facilities is required. Therefore, energy plant construction work is being actively carried out in the coastal area. In particular, it is common to build a plant in the ground by filling the coast with soil in other regions, reflecting the fact that Korea is lacking in the country when constructing power plants, gas and petrochemical plants. Current domestic grounding designs are designed or constructed to suit only the use of grounding resistors based on the electrical equipment design technical standards. However, in the case of a plant facility constructed in the untested buried soil, when the lightning current and the abnormal current are inputted, the facility operator or the user due to the elevation of the ground potential is seriously exposed to the risk of electric shock disaster. In this paper, we analyze the ground resistivity of the landfilled soil and use a computer program (CDEGS) based on KS C IEC 61936-1, We analyze the contact voltage and stratification voltage and propose a grounding design optimized for plant installation.

A Study on comnon-mode-driven shield for capacitive coupling active electrode (용량성 결합 능동 전극의 공통 모드 구동 차폐)

  • Lim, Yong-Gyu
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.13 no.4
    • /
    • pp.201-206
    • /
    • 2012
  • The indirect-contact ECG measurement is a newly developed method for unconstrained and nonconscious measurement in daily life. This study introduced a new method of electrode circuit design developed for reducing the 60Hz power line noise observed at the indirect-contact ECG measurement. By the introduced common-mode-driven shielding, the voltage of the electrical shield surrounding the capacitive coupling electrode is maintained at the same as the common mode voltage. Though the method cannot reduce the level of common mode voltage itself, that reduces effectively the differential mode noise converted from the common mode voltage by the difference of cloth impedance between the two capacitive coupling electrode. The experiment results using the actual indirect-contact ECG showed that the 60Hz power line noise was reduced remarkably though the reduction ratio was smaller than the expected by the theory. Especially, the reduction ratio became large for the large difference of cloth. It is expected that the introduced method is useful for reducing the power line noise under condition of poor electrical grounding.

A Study on the Countermeasure and the Effect of Countermeasure about Trouble-Examples by Noise in Plants (플랜트에서의 노이즈장해 사례별 대책과 그 효과에 대한 연구)

  • 유상봉;정태호;이기홍
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.15 no.5
    • /
    • pp.75-80
    • /
    • 2001
  • This paper represents the analysis and countermeasure about the causes of various trouble-examples by the noise in plants. These kinds of troubles came out the mis-operation and damage in various kinds of operating-facilities. The cause-analysis is following as: 1) the inappropriate-applications of protection devices installed to protect the noise. 2) the causes of voltage difference in separate ground systems. Therefore, To resolve the noise problems in plants, This paper proposed the two kind solutions to a problem. 1) The installation of appropriate noise protection devices and 2) The organization of equal-voltage by the common grounding system.

  • PDF

A Study on the Detail Conception of Korean Electrical Safety System Based on Comparing with Developed Countries by the Microscopic Analysis of Electricity Accidents (국내 전기안전시스템의 미시적 재해분석을 통한 선진국 전기안전시스템과 비교를 기반으로 한 국내전기안전시스템의 개념적 설계)

  • Park, Dong-Jun;Kim, Jung-Hoon;Park, Jung-Wook
    • Proceedings of the KIEE Conference
    • /
    • 2007.11b
    • /
    • pp.322-324
    • /
    • 2007
  • In this paper conceptual design methodologies of electric safety systems are proposed by micro and macro views. As a pre-study electric accidents of Korea were analyzed microscopically, which could be categorized into 11 types by the occurrence frequency. These types are caused by common problems, which are educations, live works, dealing by the public, and grounding systems. And the korean electric safety system is analyzed macroscopically according to stages of the system comparing with that of developed countries.

  • PDF

Foundation Research for Reinforced Concrete Substitution Grounding Electrode (철근콘크리트 대용접지극에 관한 기초 연구)

  • Kim, Sung-Sam;Lee, Chung-Sik;Koh, Hee-Seog
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.305-308
    • /
    • 2004
  • There are ground facility of maintenance in house electric facility of infra maintenance electric home appliances having used multifariousness in house, that use electric energy of common source for equipment. The body of building such as the reinforced concrete construction is structurally united, and the electric resistance is also small. It is possible that those foundations have contacted the ground at large surface area and that it substitutes the building construction body for the earth electrode. This is called "the structure earthing". This method has been defined at electrical facilities technical standards and KS in our country, and it has been used in various quarters practically. However, in our country, there is no example of using the foundation of the house as substitution earth electrode practically, and the means of the evaluation as electrode has not been established either. Then, in this paper, basic research for utilizing foundation of the house as substitution earth electrode is carried out.

  • PDF

Analysis on the Effects of the Induced Noise Voltage with the Grounded or Non-grounded Cable Sheath in the Power Inducting Situation (전력 유도 발생 시 케이블 쉬스 접지 여부에 따른 유도 잡음 전압 영향 분석)

  • Lee, Sang-Mu;Choi, Mun-Hwan;Cho, Pyoung-Dong
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2007.08a
    • /
    • pp.285-288
    • /
    • 2007
  • This article presents the change characteristics of induced noise whether the sheath layer of the cable is grounded or not. As what affects the induced noise, there are power influence or longitudinal transverse voltages and its weighted filtered voltage. The sheath ground is basicaly predicted to have the effects of alleviation on the power influence. But practically the effects may not happen in the case of common cable's sheath layer. Rather there are cases that the ground of sheath affects so that the noise level could increase. So we need to scrutinize the effects of the sheath gorund in the measures for the protection against electromagnetic induction by powerline or traction line system. And the evaluation of using the designated shielding purpose cable is needed.

  • PDF

Single-Phase Transformerless PV Power Conditioning Systems with Low Leakage Current and Active Power Decoupling Capability

  • Nguyen, Hoang Vu;Park, Do-Hyeon;Lee, Dong-Choon
    • Journal of Power Electronics
    • /
    • v.18 no.4
    • /
    • pp.997-1006
    • /
    • 2018
  • This paper proposes a transformerless photovoltaic (PV) power converter system based on the DC/AC boost inverter, which can solve the leakage current and second-order ripple power issues in single-phase grid-connected PV inverters. In the proposed topology, the leakage current can be decreased remarkably since most of the common-mode currents flow through the output capacitor, by-passing parasitic capacitors, and grounding resistors. In addition, the inherent ripple power component in the single-phase grid inverter can be suppressed without adding any extra components. Therefore, bulky electrolytic capacitors can be replaced by small film capacitors. The effectiveness of the proposed topology has been verified by simulation and experimental results for a 1-kW PV PCS.