• Title/Summary/Keyword: Common Glass

Search Result 181, Processing Time 0.022 seconds

Evaluation of Thermal Performance and Mechanical Properties in the Cryogenic Environment of Basalt Fiber Reinforced Polyurethane Foam (현무암 섬유 보강 폴리우레탄폼의 열적 성능 및 극저온 환경에서의 기계적 특성 평가)

  • Jeon, Sung-Gyu;Kim, Jeong-Dae;Kim, Hee-Tae;Kim, Jeong-Hyeon;Kim, Seul-Kee;Lee, Jae-Myung
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.59 no.4
    • /
    • pp.207-213
    • /
    • 2022
  • LNG CCS which is a special type of cargo hold operated at -163℃ for transporting liquefied LNG is composed of a primary barrier, plywood, insulation panel, secondary barrier, and mastic. Currently, glass fiber is used to reinforce polyurethane foam. In this paper, we evaluated the possibility of replacing glass fiber-reinforced polyurethane foam with basalt fiber-reinforced polyurethane foam. We conducted a thermal conductivity test to confirm thermal performance at room temperature. To evaluate the mechanical properties between basalt and glass-fiber-reinforced polyurethane foam which is fiber content of 5 wt% and 10 wt%, tensile and an impact test was performed repeatedly. All of the tests were performed at room temperature and cryogenic temperature(-163℃) in consideration of the temperature gradient in the LNG CCS. As a result of the thermal conductivity test, the insulating performance of glass fiber reinforced polyurethane foam and basalt fiber reinforced polyurethane foam presented similar results. The tensile test results represent that the strength of basalt fiber-reinforced polyurethane foam is superior to glass fiber at room temperature, and there is a clear difference. However, the strength is similar to each other at cryogenic temperatures. In the impact test, the strength of PUR-B5 is the highest, but in common, the strength decreases as the weight ratio of the two fibers increases. In conclusion, basalt fiber-reinforced polyurethane foam has sufficient potential to replace glass fiber-reinforced polyurethane foam.

Low Loss LTCC Materials in mm Wavelength Region with Use of Common Glass (공통 글라스를 이용한 mm 대역용 저손실 LTCC 소재)

  • Lee, Sung-Il;Yeo, Dong-Hun;Park, Zee-Hoon;Shin, Hyo-Soon;Hong, Youn-Woo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.330-330
    • /
    • 2010
  • 이동통신 시스템의 소형화, 경량화, 다기능화 추세에 따라 이동통신 부품도 단위 부피당 소자의 집적도를 증가시키기 위하여 고집적화 추세로 급진전되고 있다. 이에 따라 세라믹 공정 기술도 고집적 추세로 다층화 되고 있어 수동소자의 내장화에 대한 필요성이 증대되고 있다. 이를 위하여 다양한 유전율 대역의 이종소재간 접합을 시도하지만 de-lamination, 내부 crack 등의 결함들이 발생하므로 열팽창계수 조절이 용이한 동종의 글라스를 사용하는 것이 유용하다. 본 연구에서는 공통의 글라스를 개발한 후 다양한 필러들을 혼합하여 mm파 대역에서 다양한 유전율을 갖는 LTCC 소재를 개발함으로써, 수동소자의 내장화에 따른 이종접합시의 매칭성을 극대화하고자 하였다. 이를 위하여 CaO-$Al_2O_3-SiO_2-B_2O_3$계 공통글라스에 $CaZrO_3$, $1.3MgTiO_3$, $2La_2O_3TiO_2$ 필러를 혼합하여 소결체의 미세구조, 유전특성 및 열기계적 특성을 고찰하였다. 이때 유전율 6에서 20에 이르는 저손실 소재를 개발할 수 있었다.

  • PDF

Strength Characteristics and Non-Destructive Evaluation of Composites with Heat Damage (국부열손상을 받은 복합재료의 강도특성 및 비파괴평가)

  • Nam, Ki-Woo;Kim, Young-Un
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.173-178
    • /
    • 2002
  • Fourier transform has been one of the most common tools to study the frequency characteristics of signals. With the Fourier transform alone, it is difficult to tell whether signal's frequency contents evolve in time or not. Except for a few special cases, the frequency contents of most signals encountered in the real world change with time. Time-frequency methods are developed recently to overcome the drawbacks of Fourier transform, which can represent the information of signals in time and frequency at the same time. In this study, heat damage process of a carbon fiber reinforced plastic(CFRP) and glass fiber reinforced plastic(GFRP) under monotonic tensile loading was characterized by acoustic emission. Different kinds of specimens were used to determine the characteristics of Strength and AE signals. Time-frequency analysis methods were employed for the analysis of fracture mechanism in CFRP such as matrix cracking, debonding and fiber fracture.

  • PDF

NDE of Low-Velocity Impact Damage in GFRP Using Infrared Thermography Techniques

  • Kim, Ghiseok;Lee, Kye-Sung;Hur, Hwan;Kim, Sun-Jin;Kim, Geon-Hee
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.35 no.3
    • /
    • pp.206-214
    • /
    • 2015
  • In this study, low-velocity impact damage (LVID) in glass fiber reinforced plastic (GFRP) was investigated using pulse thermography (PT) and lock-in thermography (LIT) techniques. The main objective of this study was to evaluate the detection performance of each technique for LVID in GFRP. Unidirectional and cross-ply GFRPs were prepared with four energy levels using a drop weight impact machine and they were inspected from the impact side, which may be common in actual service conditions. When the impacted side was used for both inspection and thermal loading, results showed that the suggested techniques were able to identify the LVID which is barely visible to the naked eye. However, they also include limitations that depend on the GFRP thickness at the location of the delamination produced by the lowest impact energy of five joule.

Novel Application of Platinum Ink for Counter Electrode Preparation in Dye Sensitized Solar Cells

  • Kim, Sang Hern;Park, Chang Woo
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.3
    • /
    • pp.831-836
    • /
    • 2013
  • Platinized counter electrode is common in most of the dye sensitized solar cell (DSSC) researches because of its high catalytic activity and corrosion stability against iodine in the electrolyte. Platinum (Pt) film coating on fluorine doped tin oxide (FTO) glass surface by using alcoholic solution of hexachloroplatinic acid ($H_2PtCl_6$), paste containing Pt precursors or sputtering are widely used techniques. This paper presents a novel application of Pt ink containing nanoparticles for making platinized counter electrode for DSSC. The characteristics of Pt films coated on FTO glass surface by different chemical methods were compared along with the performance parameters of the DSSCs made by using the films as counter electrodes. The samples coated with Pt inks were sintered at $300^{\circ}C$ for 30 minutes whereas Pt-film and Pt-paste were sintered at $400^{\circ}C$ for 30 minutes. The Pt ink diluted in n-hexane was found to a promising candidate for the preparation of platinized counter electrode. The ink may also be applicable for DSSC on flexible substrates after optimization its sintering temperature.

Optimal Design of FRP Taper Spring Using Response Surface Analysis (반응표면분석법을 이용한 FRP Leaf Spring의 최적설계)

  • 임동진;이윤기;김민호;윤희석
    • Composites Research
    • /
    • v.17 no.2
    • /
    • pp.1-8
    • /
    • 2004
  • The present paper is concerned with the optimum design of taper spring, in which the static spring rate of the fiber-reinforcement composite material spring is fitted to that of the steel leaf spring. The thickness and width of springs were selected as design variables. The object functions of the regression model were obtained through the analysis with a common analytic program. After regression coefficients were calculated to get functions of the regression model, optimal solutions were calculated with DOT. E-glass/epoxy and carbon/epoxy were used as fiber reinforcement materials in the design, which were compared and analyzed with the steel leaf spring. The result of the static spring rates show that optimized composite leaf springs agree with steel leaf spring within 1%.

Relationship of the U-Factor and Chemical Structure with Applied Metal and Polymer Material Assembly in Curtain Wall Frame

  • Park, Tongso
    • Korean Journal of Materials Research
    • /
    • v.31 no.8
    • /
    • pp.450-457
    • /
    • 2021
  • From measured thermal conductivity and modeling by simulation, this study suggests that U-factors are highly related to materials used between steel and polymer. The objective and prospective point of this study are to relate the relationship between the U-factor and the thermal conductivity of the materials used. For the characterization, EDX, SEM, a thermal conductive meter, and computer simulation utility are used to analyze the elemental, surface structural properties, and U-factor with a simulation of the used material between steel and polymer. This study set out to divide the curtain wall system that makes up the envelope into an aluminum frame section and entrance frame section and interpret their thermal performance with U-factors. Based on the U-factor thermal analysis results, the target curtain wall system is divided into fix and vent types. The glass is 24 mm double glazing (6 mm common glass +12 mm Argon +6 mm Low E). The same U-factor of 1.45 W/m2·K is applied. The interpretation results show that the U-factor and total U-value of the aluminum frame section are 1.449 and 2.343 W/m2·K, respectively. Meanwhile, those of the entrance frame section are 1.449 and 2.

Early CT Findings of Coronavirus Disease 2019 (COVID-19) in Asymptomatic Children: A Single-Center Experience

  • Lan Lan;Dan Xu;Chen Xia;Shaokang Wang;Minhua Yu;Haibo Xu
    • Korean Journal of Radiology
    • /
    • v.21 no.7
    • /
    • pp.919-924
    • /
    • 2020
  • Objective: The current study reported a case series to illustrate the early computed tomography (CT) findings of coronavirus disease 2019 (COVID-19) in pediatric patients. Materials and Methods: All pediatric patients who were diagnosed with COVID-19 and who underwent CT scan in Zhongnan Hospital of Wuhan University from January 20, 2020 to February 28, 2020 were included in the current study. Data on clinical and CT features were collected and analyzed. Results: Four children were included in the current study. All of them were asymptomatic throughout the disease course (ranging from 7 days to 15 days), and none of them showed abnormalities in blood cell counts. Familial cluster was the main transmission pattern. Thin-section CT revealed abnormalities in three patients, and one patient did not present with any abnormal CT findings. Unilateral lung involvement was observed in two patients, and one patient showed bilateral lung involvement. In total, five small lesions were identified, including ground-glass opacity (n = 4) and consolidation (n = 1). All lesions had ill-defined margins with peripheral distribution and predilection of lower lobe. Conclusion: Small patches of ground-glass opacity with subpleural distribution and unilateral lung involvement were common findings on CT scans of pediatric patients in the early stage of the disease.

Picture Quality Compensation for PDP-TV in Shutter-Glass type 3D Image (셔터 글래스 방식 3D 영상에서의 PDP-TV 화질 보상)

  • Choi, Seog-Gweon;Lee, In-Soo;Kim, Kwang-Tae
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.2
    • /
    • pp.133-140
    • /
    • 2014
  • 3D stereoscopic display is becoming increasingly common. Most stereoscopic displays still require the viewers to wear 3D glasses to watch 3D contents. As it is widely known, especially in shutter glass method, 3D glasses normally cause to reduce the perceived colorfulness and sharpness considerably as well as brightness. In this paper, we have estimated and analyzed the degradation of perceptual brightness in 3D images viewed through the shutter glasses by using CIECAM02 model. This study focuses on loss of colorfulness and sharpness when PDP-TV is watched at 3D mode in shutter-glass type 3D-TV. We analyze perceptual colorfulness and sharpness of 3D display with glasses and propose a method to compensate 3D colorfulness and sharpness for the best 3D experience.

False Aneurysm of Common Carotid Artery by Trauma (외상에 의한 가경동맥루 1례 보고)

  • Oh, Bong-Seok;Choi, Jong-Beom;Lee, Dong-Jun
    • Journal of Chest Surgery
    • /
    • v.14 no.1
    • /
    • pp.67-70
    • /
    • 1981
  • Aneurysms of the extracranial carotid artery are rare. This is a case report of the rapidly expanding false carotid aneurysm at left common carotid artery, which was repaired surgically with internal shunt This 20 year old male patient had a large pulsatile mass on left lateral aspect of neck at the time of admission. About 1 month before admission, he had received a trauma on left neck by glass piece and noted massive blood loss. And its skin of lesion was sutured simply at local clinic and well healed. 10 days before the admission, he had the sudden onset of the adult thumb sized and pulsatile mass and the mass had been enlarged more and more to the adult first-sized one. The cervical film showed a egg-sized and soft tissue mass. There was systolic bruit on the mass. The diagnosis was confirmed with the angiogram of left carotid artery and this showed the man`s thumb tip-sized extravasation at the point 2 Cm below the bifurcation of Internal and external carotid arteries. The emergency operation was performed by the internal shunt with carotid artery. The aneurysm was enclosed with the adventitia and carotid sheath, and the intima and media were Intact and had the opening of 0.5 cm in diameter. The opening was sutured by the one-hand mattress suture method and firmed with the Aron Alpha-A "Sankyo." The postoperative course was uneventful and the patient was discharged with good general condition.

  • PDF