• Title/Summary/Keyword: Commercial Buildings

Search Result 446, Processing Time 0.023 seconds

A Study on Characteristics of the Modern Warehouse in Gunsan and Its Value as Industrial Heritage (군산의 근대 창고건물 현황 및 산업유산으로서의 가치에 관한 연구)

  • Pak, Sung-Sine
    • Journal of architectural history
    • /
    • v.20 no.6
    • /
    • pp.21-39
    • /
    • 2011
  • This research is to analyze the modern warehouses in Gunsan during the Japanese Colonial Period. They were the spatial and urban symbol of City of Rice, Gunsan. The main purpose of this study is to survey the modern warehouses in the original center of city, to find their architectural characteristics and to set up a possibility of reuse. 7 existing warehouse buildings are located at Jangmi-Dong and Jooksung-Dong, and they have been built between 1935 and 1940. The warehouse buildings have a module of 6m and they are generally 12m wide, 24~48m long and 8m high. Their structure is composed of reinforced concrete and wooden truss. All warehouse buildings have a rectangular form. Now the diverse commercial programs occupy the original space. Modern warehouse in Gunsan has the spatial and symbolic value as industrial heritage. Therefore, it is necessary to respect the original value of modern warehouse and to create a reusing space for the current generation. It is also essential to verify restoring possibility of three symbolic warehouse buildings in the harbour that were demolished.

Study for Improvement of Domestic System through Regulation based on Comparison of Green Building Certification System Analysis - Focused on the G-SEED, BREEAM

  • Hyun, Eun-Mi;Kim, Yong-Sik
    • KIEAE Journal
    • /
    • v.15 no.1
    • /
    • pp.13-20
    • /
    • 2015
  • The main purpose of the green buildings by reducing energy consumption and carbon footprint of the building society, global as to ensure the sustainability of the building and the environment. These regulations and schemes are used to activate the green buildings were made on the basis of the relevant laws and regulations. Mainly in the research for the improvement of the domestic institutional assessment items, the analysis of the legislation was fundamentally focused on Scoring the incomplete state. The analysis based on the laws and regulations of the institution is the way to know the purpose and direction of the respective certification. This study was performed in the following order to target the new commercial buildings. First, the analysis of the geungeobeop G-SEED and BREEAM. Second, we analyze the content and method of building energy performance in the certification system. As a result, Green Building Act is broad in relation to the composition of the contents are building for the activation energy green building and EPI is dealt with in an abstract and presented the applicability of such documentary content of insulation and airtightness, efficient machine. In contrast, the UK has been directly limit the carbon footprint of buildings in the Building Regulations Part L and evaluate them in BREEAM. This analysis of the ways to reduce substantially the energy for domestic green building regulations should be addressed through the feed.

A Study on Environment-friendliness in Tokyo Regional Hospitals - Focused on the Sustainable Site and Transportation (일본 도쿄 지역 병원의 친환경성 분석 연구 - 토지이용 및 교통부분을 중심으로)

  • Lim, Yeonghwan
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.21 no.3
    • /
    • pp.57-67
    • /
    • 2015
  • Purpose: As the concerns for the environment are gradually prioritized, increasing interests of environment-friendly buildings are drawn. Numerous researches about healthcare buildings have been performed however, they were mainly focused on convenience or healing condition for medical treatments. The hospitals consume energy and generate $CO_2$ as twice as the residential or commercial buildings do. Various green building certification systems are globally arranged. But, it isn't easy to find certification criteria for the green hospital besides the US and UK's ones which are specially designed to evaluate environment-friendly medical buildings(Lim&Yoo, 2010). Methods: In this study, we investigates current conditions of Tokyo Regional hospitals in environment-friendly standpoint and also investigates the foreign certification criteria and systems for the green healthcare building and finds the possibility to apply them to Korean one. Results: Through this study, we found that the Tokyo regional hospitals can be environmentally improved by management plans and programs. Implications: Based on this analysis, Korean Green Building Certification for healthcare facilities will be developed in near future.

"Buildings Without Walls:" A Tectonic Case for Two "First" Skyscrapers

  • Leslie, Thomas
    • International Journal of High-Rise Buildings
    • /
    • v.9 no.1
    • /
    • pp.53-60
    • /
    • 2020
  • "A practical architect might not unnaturally conceive the idea of erecting a vast edifice whose frame should be entirely of iron, and clothing the frame--preserving it--by means of a casing of stone…that shell must be regarded only as an envelope, having no function other than supporting itself..." --Viollet-le-Duc, 1868. Viollet-le-Duc's recipe for an encased iron frame foresaw the separation of structural and enclosing functions into discrete systems. This separation is an essential characteristic of skyscrapers today, but at the time of his writing cast iron's brittle nature meant that iron frames could not, on their own, resist lateral forces in tall structures. Instead, tall buildings had to be braced with masonry shear walls, which often also served as environmental enclosure. The commercial availability of steel after the 1880s allowed for self-braced metal frames while parallel advances in glass and terra cotta allowed exterior walls to achieve vanishingly thin proportions. Two Chicago buildings by D.H. Burnham & Co. were the first to match a frame "entirely of iron" with an "envelope" supporting only itself. The Reliance Building (1895) was the first of these, but the Fisher Building (1896) more fully exploited this new constructive typology, eschewing brick entirely, to become the first "building without walls," a break with millennia of tall construction reliant upon masonry

The Energy Saving Effect and Economic Assessment of Office Building according to the Building Envelope Remodeling (사무소 건물의 외피 리모델링에 따른 에너지절감효과 및 경제성 분석)

  • Choi, Seon woo;Kim, Ji Yeon;Park, Hyo soon;Kim, Jun Tae
    • KIEAE Journal
    • /
    • v.12 no.6
    • /
    • pp.85-92
    • /
    • 2012
  • The Korean government has introduced building regulations with improved energy conservation measures, including higher insulation levels for building envelope. However, there are many existing buildings that tend to consume more energy for heating and cooling than new buildings, as they were built under the former regulations with relatively higher U-values of walls and glazing. In order to improve energy efficiency in existing buildings, green remodelling of building envelope and building services are required. For existing buildings, building services improvements have been achieved through energy service company(ESCO), but much attention has not been paid to building envelope improvements with various reasons, such as uncertainty of energy saving effect design issues and costs. The aim of this study is to evaluate the impact of building envelope improvements in a typical commercial building on its heating and cooling energy loads. The results show that the improvement of glazing with lower U-values has the highest energy saving effects, followed by wall, roof and floor, under the condition of same level of insulation improvements. However, high insulated glazing increased LCC because of higher initial investment costs.

Modelling of seismically induced storey-drift in buildings

  • Lam, Nelson;Wilson, John;Lumantarna, Elisa
    • Structural Engineering and Mechanics
    • /
    • v.35 no.4
    • /
    • pp.459-478
    • /
    • 2010
  • This paper contains detailed descriptions of a dynamic time-history modal analysis to calculate deflection, inter-storey drift and storey shear demand in single-storey and multi-storey buildings using an EXCEL spreadsheet. The developed spreadsheets can be used to obtain estimates of the dynamic response parameters with minimum input information, and is therefore ideal for supporting the conceptual design of tall building structures, or any other structures, in the early stages of the design process. No commercial packages, when customised, could compete with spreadsheets in terms of simplicity, portability, versatility and transparency. An innovative method for developing the stiffness matrix for the lateral load resistant elements in medium-rise and high-rise buildings is also introduced. The method involves minimal use of memory space and computational time, and yet allows for variations in the sectional properties of the lateral load resisting elements up the height of the building and the coupling of moment frames with structural walls by diaphragm action. Numerical examples are used throughout the paper to illustrate the development and use of the spreadsheet programs.

A Study on Hidden Node Margin to Protect DTV Service in Korea (국내 DTV 서비스 보호를 위한 은닉 노드 마진 연구)

  • Kang, Kyu-Min;Cho, Sang-In;Jeong, Byung-Jang
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.12
    • /
    • pp.1165-1171
    • /
    • 2011
  • In this paper, we investigate hidden node problem to effectively utilize TV band devices(TVBDs) in the TV white space(TVWS), and also to protect digital television(DTV) service in Korea. Firstly, we classify the radio propagation environment into an urban area, a basin area, and a coastal area based on geographical characteristics. Thereafter, we measure and analyze local shape based hidden node attenuation at eight segmented positions in each geographic area. Because commercial buildings as well as residential and commercial buildings in Korea are located in closer proximity to each other than in other countries, hidden node margin should be more than 38 dB in order to safely protect DTV service in Korea.

Derivation of preliminary derived concentration guideline level (DCGL) by reuse scenario for Kori Unit 1 using RESRAD-BUILD

  • Park, Sang June;Byon, Jihyang;Ban, Doo Hyun;Lee, Suhee;Sohn, Wook;Ahn, Seokyoung
    • Nuclear Engineering and Technology
    • /
    • v.52 no.6
    • /
    • pp.1231-1242
    • /
    • 2020
  • The Kori Unit 1 will be decommissioned after a permanent shutdown in June 2017. South Korea has a 0.1 mSv/yr exposure limit standard for limited or unlimited site release. This is South Korea's first commercial NPP; therefore, if the containment building is reused as a memorial hall, it will contribute to the improvement of public understanding and enhance the public's acceptance of NPPs. Also, existing Kori Unit 1 nuclear power plant manpower resources can be reused after decommissioning and resident staff and memorial hall visitors can activate nearby commercial areas. Therefore, such a reuse scenario may also prevent an economic recession. The exposure dose was calculated using the following scenarios: worker in the containment building, visitor in the containment building, and worker in buildings other than the containment building. The exposure dose in the buildings was calculated by the RESRAD-BUILD developed by the Argonne National Laboratory (ANL). The preliminary exposure dose and derived concentration guideline level (DCGL) were derived.

Development of Building Integrated PV(BIPV) module for the replacement of commercial building envelope materials (건물외피용 태양광발전 BIPV 모듈 개발 연구)

  • Yoon, Jongho;Kim, J.I;Lee, K.S.;Yu, G.J.
    • KIEAE Journal
    • /
    • v.4 no.3
    • /
    • pp.113-119
    • /
    • 2004
  • As Building Integrated Photovoltaic(BIPV) system replaces the conventional building finishing materials with PV modules, two function of electricity generation and building envelope can be expected. Therefore BIPV can be a good alternative technology for the 21 century environment-friendly buildings. The objective of this paper is to develope BIPV modules for a commercial buildings of which structure is mainly light-weight, curtain wall system. Two types of module are developed for a opaque part and a transparent part of building envelope. Current technology level and market status of Korea determines the configuration of developed BIPV modules. Architectural considerations for the integration of PV module to building envelope such as building structure, construction type, safety, regulation, maintenance etc. have been carefully reflected from the early stage of BIPV module design. Especially the survey result of current building envelope materials determines the size of unit BIPV modules and a unique cladding method for PV module installation is developed. Trial product of BIPV modules and cladding hardwares are manufactured and sample construction details for a demonstration building are proposed.

Analysis on Luminous Environment and Subjective Image of Two Different Commercial Streets at Night - Focused on View Point of Pedestrian - (야간상업가로의 조명물리량 및 이미지 분석 - 보행자 시점을 기준으로 -)

  • Shin, Ju Young;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.7 no.4
    • /
    • pp.31-38
    • /
    • 2007
  • Streetscape plays on important role in urban cities. Characteristics of streets is basically defined by the building facade, signs, plants and paving during the daytime. However at night, street receives a new appearance due to the shop light from the buildings, exterior lightings, signboards and street light, and it creates most of the image of the streets. This study aims to analyze the luminous environment and its subjective image of two different pedestrian's commercial streets. Insa-dong street and Myungdong street were chosen for the study. Horizontal illuminance and luminance on building surface, advertisement billboards and pedestrian road were measured. Thirty students were asked to rate the five scaled questionnaire on their subjective images of the streets. Statistical analysis including profile, correlation and T-test are conducted and some findings are discussed