• 제목/요약/키워드: Comfort Evaluation

검색결과 684건 처리시간 0.025초

고속에서 한국형 고속철도 차량의 승차감 추정 (Estimation of Ride Comfort for Korean High Speed Train at High Speed)

  • 김영국;김석원;목진용;김상수;김기환
    • 한국철도학회논문집
    • /
    • 제10권2호
    • /
    • pp.146-152
    • /
    • 2007
  • The ride comfort is more important in the train speedup. Generally, it is defined as the vehicle vibration. There are many studies on evaluation method of ride comfort for railway. But the ride comfort for Korean high speed train(HSR 350x) has been assessed by statistical method according to UIC 513R. It is impossible for HSR 350x to run at constant speeds above 310km/h during 5 minutes required in UIC 513R because of the same operational condition as KTX and the design limitation of infrastructures. The ride indices data had been acquired from 80 to 310km/h through the on-line test. The present study has suggested the methodology for the estimation of the ride indices at high speed above 310km/h by using those obtained below 310km/h and reviewed the ride comfort for HSR 350x in these speeds.

Evaluation of Thermal Comfort on Protective Clothing Worn in an Radiation Power Plant

  • Kim, Eun-Joo;Han, Myung-Sook;Lee, Won-Ja
    • The International Journal of Costume Culture
    • /
    • 제3권1호
    • /
    • pp.30-40
    • /
    • 2000
  • The purpose of this research was to device thermal comfort model for radiation power plant workers in protective clothing. Three fabrics commonly used in protective workwear were made into coveralls of identical design and were evaluated by adult healthy males in four simulated work environment. It was investigated between the physiological response and subjects comfort according to environmental variance and clothing types. The of simulated work enviro mensent was controlled under four different humidity and temperature of each type. (Temperature 20±1℃, RH 40∼70%±5%, Temperature 30±1℃, RH 40∼70%±5%) An index of physiological response was connected with the thermal comfort designed. Mean skin temperature, skim temperature, Axillasy temperature ear canal temperature, clothing climate, total sweat, blood pressure, and R-R interval were be evaluated. Skin temperature difference ocurring during exercise and rest were significant only with respect to time and regions of the body, This despite physical differences in the three coveralls, particulary mass statistically experiment. Also, an index of subject wearing sensation was designed for thermal comfort after investigation determined the kind of clothes and the type of environment. As a result of this research, two types of multiple regressions was deviced to estimate thermal comfort of the protective clothing.

  • PDF

여름철 사무실내 온열환경 특성 및 쾌적성 평가 (Characteristics of Thermal Environments and Evaluation of Thermal Comfort in Office Building in Summer)

  • 이철희;배귀남;최항철;이춘식
    • 설비공학논문집
    • /
    • 제6권3호
    • /
    • pp.206-217
    • /
    • 1994
  • In this study, indoor thermal parameters were measured to investigate the characteristics of thermal environments and 212 occupants were questioned to evaluate Korean thermal comfort in office building in summer. Thermal and comfort sensations were estimated using PMV(Predicted Mean Vote) and ET* (New Effective Temperature) which are most widely used nowadays. Comparing this experimental result with international standards and that of other research, Korean thermal responses were discussed. It was found that TSV(Thermal Sensation Vote) is more sensitive than PMV to the variation of temperature and that the measured percentage of dissatisfied is higher than PPD(Predicted Percentage of Dissatisfied) in real office building environments. By regression analysis, the following regression equation has been obtained: TSV=0.461ET*-11.808 and neutral temperature is $25.6^{\circ}C$ in this case. Thermal comfort range based on 80% satisfaction is also $24.0{\sim}26.8^{\circ}C$, which is about $1^{\circ}C$ higher than that of ANSI/ASHRAE Standard.

  • PDF

주거 공간에서의 룸 에어컨디셔너 실내기 유형에 따른 온열쾌적성 및 에너지성능 평가 (Evaluation of Thermal Comfort and Energy Efficiency According to Indoor-Unit Types of Room Air-Conditioner in Housing Space)

  • 석호태;김동우;양정훈
    • 한국주거학회논문집
    • /
    • 제20권4호
    • /
    • pp.19-29
    • /
    • 2009
  • The purpose of this study is to evaluate the air diffusion performance of a range of indoor units for room airconditioners; the wall-mounted type, floor-standing type, and ceiling-mounted type. These types of units, which have been widely used in housing spaces, will be studied with respect to thermal comfort and the energy performance using CFD analysis. In this study, current air conditioning status and related problems in housing spaces are examined, and a CFD analysis is performed in order to compare and analyze the thermal comfort and energy efficiency across each type of indoor-unit using the PMV, ADPI, EUC and FCEI indexes. The analysis results collectively considering thermal comfort and energy performance indicated that the ceiling-mounted type 4-way indoor unit showed the best diffusion performance in terms of thermal comfort, and had the second best diffusion performance in terms of energy performance after the wall-mounted type under certain conditions.

인체모델을 고려한 자동차 실내의 에어컨 토출구 위치 변화에 따른 냉방성능 및 온열쾌적성 평가 (Evaluation of Thermal Comfort and Cooldown Performance inside Automotive Cabin according to Air-conditioning Vent Location)

  • 서진원;박재홍;최윤호
    • 한국자동차공학회논문집
    • /
    • 제20권5호
    • /
    • pp.120-129
    • /
    • 2012
  • As the recent advancement of automobile industry, there has been a great interest in the thermal comfort of the passengers inside the cabin of an automobile. Thermal comfort is affected by temperature, velocities, and mean radiation temperature of air, thermal resistance of clothes and physical active level of human. The present study performed computational analysis to select the location of air-conditioning vent that improves thermal comfort inside the cabin. In order to do this, we considered various air vent positions, and thermal flow analysis of each case is performed using CFD for the cabin with four passengers. The thermal comfort is evaluated using the computational results and the optimum location of air vent is suggested.

자동차 에어컨 쾌적제어 알고리즘 개발을 위한 운전자 온열감성 평가 : 제 1 보-운전자의 에어컨 조작 선호도 (Comfort Control Algorithm Development of Car Air Conditioner using Thermal Comfort Evaluation of Driver : Part I - Air-conditioning Operating Preference of Driver)

  • 김민수;김동규;이기덕;금종수
    • 설비공학논문집
    • /
    • 제26권6호
    • /
    • pp.294-300
    • /
    • 2014
  • In this study, we investigated and evaluated the air conditioning operation of the driver according to the temperature difference between the inside and outside of a car parked outside during the summer. We suggest including a comfort mode to the car air conditioning system to improve the thermal comfort of the driver, in which the comfort can be maintained for a longer time. For the a result of our experiment, in the cases with temperature of above $45^{\circ}C$ inside of the car, the subjects preferred strong air blow with the face and the arms in the direction of the blow. In the cases with temperature of below $40^{\circ}C$ inside of the car, the subjects preferred lower volume of air blow. In the temperature below $28.1^{\circ}C$ inside of the car, the mean temperature on the skin of the driver reached the comfort zone.

천장형 시스템 에어컨의 토출방향 변화에 따른 실내 열쾌적성 평가 (Evaluation of Indoor Thermal Comfort for Ceiling Type System Air-Conditioner with Various Discharge Angles)

  • 이진형;김유재;최원석;박성관;윤백;김윤제
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.1180-1185
    • /
    • 2006
  • Modern people spend most of time at indoor space, such as office or classroom. Especially, occupants are exposed to the airtight indoor air quality (IAQ) for a long time, At present, many studies on the air-conditioning systems are more focused on the individual thermal comfort than the thermal efficiency due to increase of the concern of health. There are several factors which are influenced thermal comfort, such as temperature, humidity, convection and air movement, etc. Also, the individual factor, such as age, gender, Physical constitution and habit, should be considered. The 4-way cassette type air conditioner is known to bring out better performance about thermal comfort than the traditional one. This study is performed on the higher ceiling environment than the common buildings or classrooms. Also, this study analyzed on the Indoor thermal comfort by diffusing direction of 4-way cassette air conditioner with various discharge angles, $45^{\circ},\;50^{\circ},\;55^{\circ}$ and $60^{\circ}$. Using a commercial code, FLUENT, three-dimensional transient air thermal flow fields are calculated with appropriate wall boundary conditions and standard $k-{\epsilon}$ turbulence model. Results of velocity and temperature distributions are graphically depicted with various discharge angles.

  • PDF

Environmental Modeling and Thermal Comfort in Buildings in Hot and Humid Tropical Climates

  • Muhammad Awaluddin Hamdy;Baharuddin Hamzah;Ria Wikantari;Rosady Mulyadi
    • Architectural research
    • /
    • 제25권4호
    • /
    • pp.73-84
    • /
    • 2023
  • Indoor thermal conditions greatly affect the health and comfort of humans who occupy the space in it. The purpose of this research is to analyze the influence of water and vegetation elements as a microclimate modifier in buildings to obtain thermal comfort through the study of thermal environment models. This research covers two objects, namely public buildings and housing in Makassar City, South Sulawesi Prov-ince - Indonesia. Quantitative methods through field surveys and measurements based on thermal and personal variables. Data analysis based on ASHRAE 55 2020 standard. The data was processed with a parametric statistical approach and then simulated with the Computational Fluid Dynamics (CFD) simulation method to find a thermal prediction model. The model was made by increasing the ventilation area by 2.0 m2, adding 10% vegetation with shade plant characteristics, moving water features in the form of fountains and increasing the pool area by 15% to obtain PMV + 0.23, PPD + 8%, TSV-1 - +0, Ta_25.7℃, and relative humidity 63.5 - 66%. The evaluation shows that the operating temperature can analyze the visitor's comfort temperature range of >80% and comply with the ASHRAE 55-2020 standard. It is concluded that water elements and indoor vegetation can be microclimate modifiers in buildings to create desired comfort conditions and adaptive con-trols in buildings such as the arrangement of water elements and vegetation and ventilation systems to provide passive cooling effects in buildings.

A Method to Protect Mine Workers in Hot and Humid Environments

  • Sunkpal, Maurice;Roghanchi, Pedram;Kocsis, Karoly C.
    • Safety and Health at Work
    • /
    • 제9권2호
    • /
    • pp.149-158
    • /
    • 2018
  • Background: Work comfort studies have been extensively conducted, especially in the underground and meteorological fields resulting in an avalanche of recommendations for their evaluation. Nevertheless, no known or universally accepted model for comprehensively assessing the thermal work condition of the underground mine environment is currently available. Current literature presents several methods and techniques, but none of these can expansively assess the underground mine environment since most methods consider only one or a few defined factors and neglect others. Some are specifically formulated for the built and meteorological climates, thus making them unsuitable to accurately assess the climatic conditions in underground development and production workings. Methods: This paper presents a series of sensitivity analyses to assess the impact of environmental parameters and metabolic rate on the thermal comfort for underground mining applications. An approach was developed in the form of a "comfort model" which applied comfort parameters to extensively assess the climatic conditions in the deep, hot, and humid underground mines. Results: Simulation analysis predicted comfort limits in the form of required sweat rate and maximum skin wettedness. Tolerable worker exposure times to minimize thermal strain due to dehydration are predicted. Conclusion: The analysis determined the optimal air velocity for thermal comfort to be 1.5 m/s. The results also identified humidity to contribute more to deviations from thermal comfort than other comfort parameters. It is expected that this new approach will significantly help in managing heat stress issues in underground mines and thus improve productivity, safety, and health.

달리기 동호인들의 상해예방을 위한 맞춤형 발 보장구의 평가연구 (The Evaluation of Custom Foot Orthotics for Injury Prevention of Joggers)

  • 김로빈
    • 한국운동역학회지
    • /
    • 제16권1호
    • /
    • pp.19-30
    • /
    • 2006
  • The purpose of this study was to examine the effect of foot orthotics on the overall comfort and muscle activity during running. The subjects were 10 members from the joggers' club which consisted of 2 women and 8 men. These individuals ran on the treadmill by 4.0m/s speed with and without the custom foot orthotics. The data concerning the overall comfort was collected by a questionairre that examined the overall comfort, heel cushioning, forefoot cushioning, medio-lateral control, arch height, heel cup fit, shoe heel width, forefoot width, and shoe length The MegaWin ver. 2.1(Mega Electronics lid, Ma. Finland) was used to gain electromyography signals of the muscle activity; Tibialis anterior, medial gastronemius, lateral gastronemius, vastus lateralis, vastus medialis, biceps femoris, and rectus femoris were measured. The results of the study were as follows. 1. During running the overall comfort was higher for the foot arthotic condition than the nonorthotic condition. Among the inquiries the overall comfort showed the biggest difference comparing the two conditions. and the shoe heel width showed the highest score for contort. 2 The muscle activity of the biceps femoris, and vastus lateralis in the stance period decreased. due to the foot orthotics. The muscle activity of the vastus medialis in the swing period also decreased and the muscle activity tibialis anterior in the stance and swing stance decreased as well During running, orthotics showed positive result in foot comfort. The foot comfort related to decreased stress, muscle activity, and foot arch strain. Overall comfort and the adequate decrease of muscle activity were associated with injury prevention and the best method to prevent injury semms to be the maintenance of foot comfort.