• 제목/요약/키워드: Comfort Conditions

검색결과 454건 처리시간 0.029초

3차원 가상착의 시스템을 활용한 남성용 커버롤 도장 작업복의 작업동작 적합성 평가 (The Evaluation of the Work Motion Suitability of Men's Coverall Type Painting Work Clothes Using 3D Virtual Clothing Simulation)

  • 박진아
    • 패션비즈니스
    • /
    • 제24권4호
    • /
    • pp.63-84
    • /
    • 2020
  • It is essential to consider the heavy industrial working environment factors which are regarded as harmful to workers' health and safety and suitable work motion factors for the workers' motion while developing the work clothes for painting workers in the machinery and shipbuilding industries. This study suggests the use of 3D virtual clothing simulations as a solution to protect the human body from hazardous working conditions accompanying the development of painting work clothes and assessing the work motion performance associated with the comfort while workers wear them during the work clothes. The initial aim of the study is to examine a male avatar to run work motions simultaneously within a 3D virtual clothing simulator, secondly, to present the simulation images of coverall type men's painting work clothes with the application of two experimental painting work motions and one control motion to the avatar, and finally, to present the distance analysis images of the painting work clothes and the avatar body and air gap rates through the analysis of cross-sections of the avatar body while wearing the coverall work clothes according to the work motions. The results showed that the distance degree of painting work clothes to the avatar body for each part of the human body when performing painting work motions. Moreover, 3D virtual clothing simulations enabled the creation of a male model avatar to run painting work motions together and the painting work clothes developed were found to be suitable for the painting work motions.

온돌에서의 욕의 쾌적성에 관한 연구 (A Study on the Comfort, Physiological Responses and Microclimate in Beding Pad)

  • 이순원;권수애
    • 한국의류학회지
    • /
    • 제14권1호
    • /
    • pp.44-54
    • /
    • 1990
  • The purpose of this study was to investigate the effects of thickness of the sleeping pad on the physiological responses and the microclimate in the heating ondol room during sleeping time. The measuring points were skin temp., weight loss and body movement as physiological responses and the compression ratio, the temp. on/under the sleeping pad, the inside limp. of the sleeping quilts and subjective sence while 7 hours sleeping. Thickness of sleeping pads was 27.2 mm(A), 34.8 mm (B), 47.9 mm(C) used for 90 days and no used pad 60.7 mm(D). The floor surface temp. was keeping $29{\pm}1^{\circ}C$ while the environmental conditions was at $23{\pm}1^{\circ}C$ ($50{\pm}5\%$ R.H.) The results were as followings; 1) The mean compression ratio after using the sleeping pads for 45 days was about $70\%$ , and it wasn't increased any more thereafter 2) After 2 hours sleeping the temp. under the sleeping pads was shown that C and D were higher than A and B, and the temp. on the sleeping pads was shown that A and C pads were higher than B and D. But after 3-4 hours sleeping the skin temp. of legs was shown that B and D pads were higher than A and C. 3) Weight loss for C pad was significantly higher than others. Body movement and side position in tying was higher in A and C pads than B and D. 4) The inside temp. of quilt for A and C pads were higher in the early part of sleeping period than those of B and C pads and relative humidity was lower in C than others. 5) D pad was softer than others and fatigue degree was turned out to be lowest in D, the highest in A. From this point of view, we concluded that thickness of the sleeping Pad in the heating ondol room had different characteristic from that in no heating ondol room. And 35 mm used pad was turned out to be proper.

  • PDF

내측 블라인드의 하절기 일사열 차폐 성능 비교 (Comparing Solar Heat Shading Performances of Internal Blinds in the Summer)

  • 박은미;최동호;박민용;이경희
    • 한국태양에너지학회 논문집
    • /
    • 제34권6호
    • /
    • pp.75-83
    • /
    • 2014
  • Heat loss through windows and doors occupies 20 to 45% of the total heat loss in building. It accounts for a large proportion of the total heat loss in building. In order to suppress the amount of heat flow through the windows and doors were considered actions such as reinforcement of insulation performance of window, adoption of low-e glass, and installation of solar heat shading device. The Purpose of this study is to compare solar heat shading performances of 3 types of internal blinds in the summer. In order to verify the solar heat shading performances of the blinds, a roll blind, blind A(Venetian blind) and blind B(Daylight guiding venetian blind)were installed in the four rooms with the same environmental conditions. As a result of the experiment, the blind B, blind A, roll blind showed an excellent performance in that order. Its because the blind B is made of aluminum materials coated with special paints on surface. It doesn't converted to long wave by short wave light. and it is reflected to short wave to outside.

곡선부 최적 선형 설계기법에 관한 연구 (A Study on Optimum Design for Railway Alignment in Curve)

  • 엄주환;양신추;김은경
    • 한국철도학회논문집
    • /
    • 제12권4호
    • /
    • pp.597-603
    • /
    • 2009
  • 본 연구에서는 승차감을 목적함수로 하고 궤도부담력을 경계조건으로 하는 곡선부 평면선형의 최적설계 기법을 제시하였다. 평면선형 최적화시 중요한 변수인 곡선반경-완화곡선장은 엄주환 등(2009)에서 제시한 결정방법을 적용하였으며 승차감 평가방법은 영국 BSI(2006)에서 제시하는 곡선부 전용 승차감 평가방법인 $P_{CT}$방법을 활용하였다. 또한 한국형 고속전철 G7(KTX-II)모델을 이용한 차량/궤도선형 상호작용 해석을 수행하였다. 해석결과, 최적선형조건은 교각 I(곡선부 양 끝단 직선과 직선이 만나는 교차각) 크기 및 곡선반경-완화곡선장 조합에 따라 다름을 알 수 있었다. 또한 Kufver(1997) 등에서 제시하는 간략화 해석방법과 유사한 경향이 나타남을 알 수 있었으나, 대부분의 경우 동적해석결과 값이 크게 나타났다. 따라서 곡선부 최적선형 설계시 동적해석과 간략화 해석을 병행한다면 신속하고 신뢰성 높은 최적선형을 결정할 수 있을 것으로 판단된다.

상용차 시트용 X-형 구조 마그네틱 현가기구의 최적 설계 및 성능평가 (Optimal Design and Performance Evaluation of X-type Magnetic Spring Suspension for Commercial Vehicle Seat)

  • 곽이구;김홍건;송정상;신희재;서민강;김병주;안계혁;이혜민;한웅
    • 한국생산제조학회지
    • /
    • 제23권5호
    • /
    • pp.456-464
    • /
    • 2014
  • Commercial vehicle drivers typically feel more fatigued compared to general-public drivers. because they spend longer periods of time driving and experience more rough road conditions. This study showed that the application of a magnet, a linear spring, and a seat suspension with nonlinear characteristics was the optimal design to increase comfort while driving. The resonant frequency for the optimal design suspension was 2.8 Hz, and the stiffness was analyzed through displacement-load experiments. Vibration transmissibility was analyzed by suspension stiffness and the existing dynamic compression. The magnetic spring type was at 0.875. As a result, the X-type magnetic spring performed better than the existing spring at 0.729.

Wettability of denture relining materials under water storage over time

  • Jin, Na-Young;Lee, Ho-Rim;Lee, Hee-Su;Pae, Ahran
    • The Journal of Advanced Prosthodontics
    • /
    • 제1권1호
    • /
    • pp.1-5
    • /
    • 2009
  • STATEMENT OF PROBLEM. Poor wettability of denture relining materials may lead to retention problems and patient discomfort. PURPOSE. Purpose of this study is to compare and evaluate wettability of nine denture relining materials using contact angle measurements under air and water storage over time. MATERIAL AND METHODS. Nine denture relining materials were investigated in this study. Two heat-curing polymethyl-methacrylate(PMMA) denture base materials: Vertex RS, Lang, one self-curing polyethyl-methacrylate(PEMA) chairside reline resin: Rebase II, six silicone relining materials: Mucopren soft, Mucosoft, $Mollosil^{{R}}$ plus, Sofreliner Touch, GC $Reline^{TM}$ Ultrasoft, Silagum automix comfort were used in this experiment. Contact angles were measured using high-resolution drop shape analysis system(DSA 10-MK2, KRUESS, Germany) under three conditions(in air after setting, 1 hour water storage, and 24 hours water storage). Nine materials were classified into three groups according to material composition(Group 1: PMMA, Group 2: PEMA, Group 3: Silicone). Mean values of contact angles were compared using independent samples t-test and one-way ANOVA, followed by a Scheffe's post hoc analysis($\alpha$=0.01). RESULTS. Contact angles of materials tested after air and water storage increased in the following order: Group 1(PMMA), Group 2(PEMA), Group 3(Silicone). Heat-cured acrylic denture base resins had more wettability than silicone relining materials. Lang had the highest wettability after 24 hours of water storage. Silicone relining materials had lower wettability due to their hydrophobicity. Wettability of all denture relining materials, except Rebase II and $Mollosil^{{R}}$ plus, increased after 24 hours of water storage. CONCLUSIONS. Conventional heat-cured resin showed the highest wettability, therefore, it can be suggested that heat-cured acrylic resin is material of choice for denture relining materials.

Study on the Performances of Air Flow Fate Effect on a Structured Packed Tower at Adiabatic Condition in a Liquid Lithium Chloride Cooling System

  • Bakhtiar, Agung;Choi, K.H.;Kim, J.R.
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 추계학술발표대회 논문집
    • /
    • pp.404-408
    • /
    • 2009
  • The liquid desiccant air-conditioning system has been proposed as an alternative to the conventional vapor compression cooling systems to control air humidity. The complete system of liquid desiccant air-conditioning system is consisted two main components those are humidifier (regeneration) and dehumidifier. Humidifier part is connected to the load when summer season which is the air condition is hot and humid have to be turned into comfort condition on human. This paper purpose is performances study of air flow rate effect on a structured packed tower on cooling and dehumidifier system using liquid lithium chloride as the desiccant. Experimental apparatus used in this present study is consisted of three components those are load chamber, packed tower and chiller. Load chamber’s volume is $40m^3$, and packed tower dimension is cubic with length 0.4m occupied with packed column. Totally, 15 experimental has done using 5 times repeat on each variable of air velocity that varying on 2m/s, 3m/s and 4m/s with other conditions are controlled. Air inlet initial temperature and relative humidity are set respectively on $30^{\circ}C$ and 52%, desiccant flow rate is 0.63 kg/s, desiccant temperature is $10^{\circ}C$ and desiccant concentration is 0.4. The result of this study shows that averagely, the moisture removal rate and the heat transfer rate are influenced by the air velocity. Higher air velocity will increase the heat transfer and decreasing the moisture removal rate. At adiabatic condition the air velocity of 2 m/s respectively is having the higher moisture removal rate acceleration then the air velocity of 3m/s and 4 m/s until the steady state condition.

  • PDF

공동주택단지배치의 간극비와 바람장의 상관관계에 관한 연구 (A Study on Correlations of the Gap Ratio of Apartment Houses Arrangement and the Wind Field)

  • 문출성;오세규;조성우
    • KIEAE Journal
    • /
    • 제11권2호
    • /
    • pp.75-82
    • /
    • 2011
  • In Korea, the ratio of population in urban areas used to be only 50.1% in 1970, but with the value risen to 90.8% in 2009, urbanization is going on rapidly. Urbanization, which occurs by the rampantly planted buildings, has become major source of raising building density, changing wind direction and reducing wind amount, and such reductions are affecting even inside the building. In each year, among the total energy consumption in Korea, residential portion takes up significant ratio, and specifically the ratio of apartment house is shown to be highest. In order to solve such problem, many studies are being conducted for the improvement of natural ventilation performance. The natural ventilation performance of apartment house are significantly determined by the characteristics of external and internal structure, but in macroscopic perspective, the performance is established fundamentally by the layout characteristics of the main building of the apartment house in preparation for wind conditions. So far researches on raising the thermal comfort through elevation of ventilation performance have been conducted actively, but many of them propose only theoretical concepts deduced through wind path analysis, and do not include any indicator to measure ventilation performance simply only with area data from layout planning stage. Therefore, in this study, gap ratio a wind field measuring indicator was developed, and after the ventilation characteristics by layout types and main building uniformity were identified, the scope of gap ratio efficient for ventilation and that of uniformity were clarified, followed by verification through simulation.

에어로빅복의 유니버설 디자인을 위한 동작 적합성 평가 (An Evaluation of Aerobic Exercise Wear Mobility as a Basic Criterion for Universal Design)

  • 손주희;최정화;강태진
    • 한국의류학회지
    • /
    • 제31권3호
    • /
    • pp.343-350
    • /
    • 2007
  • This study compared and studied the clothing mobility of two types of aerobic clothes - those made of currently popular stretch materials and those made of new stretch materials that were specially developed for this study. The focus of the comparison was on the range of joint movement during activity, and the physiological burden imposed on the body by the clothes. In total, 18 experiments were carried out under controlled conditions in an artificial climatic chamber with a temperature of $25{\pm}1^{\circ}C$, air humidity of $60{\pm}5^{\circ}C$ and negligible air movement. Each exercise program consisted of a 30-minute of aerobic workout and a 20-minute rest following the exercise. Measurements were taken to determine the following: physiological reactions (whole-body and local sweat rates), subjective sensations(of temperature, humidity, comfort, tightness, and clothing wetness), joint angle(measured with a goniometer), and so on. The results of the study us as follows: Material B excels in clothing mobility. Material C excels in sweat absorbency and drying speed. Material A was found to be the hottest material, while material C was found to be slightly hot through the analysis of the change in pre- and post-exercise bodyweight(= amount of sweat). Regarding the amount of evaporated sweat, material A>material C>material B. Material B produced the smallest amount of evaporated sweat. The wider the range of joint movement, the smaller the amount of sweat and the lower the average skin temperature.

A Study on the Shrinkage of Silk Fabric by $Ca(NO_3){_2}$ Solution

  • Choi, Se-Min;Shin, Yu-Ju;Kim, Jong-Jun;Jeon, Dong-Won
    • 패션비즈니스
    • /
    • 제13권3호
    • /
    • pp.136-148
    • /
    • 2009
  • The phenomenon of the shrinkage of silk fibers induced by inorganic salts including LiBr, $Ca(NO_3){_2}$, and $CaCl_2$, has been studied up to the present as one of the finishing methods of silk. It is expected that the shrinkage phenomenon may greatly contribute to the realization of the high sensibility of silk fibers. Especially the shrinkage enables the expression of three-dimensional appearance of silk fabrics along with the improvements in dimensional stability, resilience in stretching, and comfort. Numerous theoretical studies on the contraction phenomenon by $Ca(NO_3){_2}$ have been conducted so far. These studies have focused mostly on the silk fibers. It is difficult to find studies on silk fabrics. The negative aspects of the finishing are such as strength drop, yellowish discoloration, and fiber damage. These should also be considered as well as the positive aspects. In this study, the phenomenon of salt shrinkage is diversely reviewed by applying $Ca(NO_3){_2}$ solution for the silk fabrics as objects. The changes in the air permeability, thickness, and color were investigated with focus on the shrinkage of the silk fabrics according to the changes in treatment conditions. Some findings from this study are as follows: Within short period of time at the initiation of salt shrinkage, the salt shrinkage proceeds effectively. In the case of concentration of 47.4%, or 46.3% of $Ca(NO_3){_2}$ solution, appropriate treatment time seems to be 20seconds, or $2{\sim}8$minutes, respectively. Excessive shrinkage is obtained when lower liquor ratio is adopted. As a result, the condition is acting extremely disadvantageously against the thickness and yellow discoloration aspects.