• 제목/요약/키워드: Combustion Phenomena

검색결과 353건 처리시간 0.03초

내연기관 밸브회전 거동에 관한 해석적 연구 (An Analytic Study on the Valve Rotation Behavior of an Internal Combustion Engine)

  • 김도중;윤재원;김진웅;송진욱
    • 한국자동차공학회논문집
    • /
    • 제14권2호
    • /
    • pp.184-193
    • /
    • 2006
  • Rotation of intake and exhaust valves are very closely related to the long term durability of automotive engines. If the valves do not rotate even at a rated engine speed, it causes the uneven wear of the valve seat and valve head contact area, which eventually shortens the engine life. A principle of valve rotation mechanism was presumed based on some findings from experiments, and computer programs were developed to simulate the valve rotation phenomena. In this study we investigated the valve rotation mechanism by using the computer simulation models.

대형엔진용 액상분사식 LPG 연료공급 방식에 대한 기초연구 (1) (Fundamental Study on Liquid Phase LPG Injection System for Heavy-Duty Engine (I))

  • 김창업;오승묵;강건용
    • 한국자동차공학회논문집
    • /
    • 제9권4호
    • /
    • pp.85-91
    • /
    • 2001
  • LPG has been well known as a clean alternative fuel for vehicles. As a fundamental study on liquid phase LPG injection (hereafter LPLI) system application to heavy-duty engine, engine output and combustion performance were investigated with various operating conditions using a single cylinder engine equipped with the LPLI system. Experimental results revealed that no problems were occurred in application of the LPG fuel to heavy-duty engine, and that volumetric efficiency and engine output, by 10% approximately, were increased with the LPLI system. It was resulted from the decrease of the intake manifold temperature through liquid phase LPG fuel injection. These results provided an advantage in the decrease of the exhaust gas temperature, in the control of knocking phenomena, spark timing and compression ratio. The LPLI engine could normally operated under $\lambda$=1.5 or EGR 30% condition. The optimized swirl ratio for the heavy duty LPG engine was found around R_s$ = 2.0.

  • PDF

충격파관 시스템설계에 의한 분무의 착화현상 연구 (A Study on Ppray Ignition Phenomena Using Shock Tube Combustion System Design)

  • 정진도
    • 에너지공학
    • /
    • 제3권1호
    • /
    • pp.54-61
    • /
    • 1994
  • 계단형태의 고온발생장치로서, 고온의 흐름을 형성하고 난류유동이 없이 일정한 혼합기류를 만들 수 있는 2단격막구조 충격파관 장치를 이용하여, 혼합을 동반하지 않는 분무의 착화과정에 관한 실험을 수행하였다. 본 실험에서는 충격파관 속에 하향으로 설치된 초음파 분무기에 의해 자유낙하 상태에 있는 예혼합 분무주를 만들어서 반사충격파에 의해 순간적으로 단열압축시켜서 착화 현상을 관찰하였다. 고온영역과 저온영역에서 얻어진 활성화에너지는 큰 차이가 나며 본 연구에서 얻은 착화지연의 실험결과는 통상의 분무착화 실험인 전기로법, 급속압축기법, 고온기류속에 연료를 분사하는 방법과 다른 현상을 보였다. 그 대표적인 결과에 대한 예로는 착화지연에 대한 압력 의존성과 연료분사율의 영향이 일반적인 분무의 결과에 비해 적게 나타났다.

  • PDF

가스터어빈 연소기의 화염 안정화와 제어 (Flame Stabilization and Control in Gas Turbine Combustor)

  • 최경민
    • 한국분무공학회지
    • /
    • 제8권4호
    • /
    • pp.24-30
    • /
    • 2003
  • This paper presents the characteristics of lifted height and flame length from non-premixed jet flames in highly preheated air to investigate the detail combustion mechanism in the gas turbine or HCCI engine, etc. Special attention was paid to the effect of preheated air temperature, oxygen concentration and fuel injection flow rate on flame length and lifted hight. By using highly preheated air, stable flames were formed even in low oxygen concentration condition. The lifted height increased with decreasing preheated air temperature, where the flame length showed opposed phenomena. The flamelet model, which is thought to have very thin flamelet, is difficult to applicable to the present flame conditions which is formed In low oxygen concentration in highly preheated air.

  • PDF

Gas turbine Control using Neural-Network 2-DOF PID Controller

  • Kim, Dong-Hwa
    • 한국지능시스템학회:학술대회논문집
    • /
    • 한국퍼지및지능시스템학회 1998년도 춘계학술대회 학술발표 논문집
    • /
    • pp.61-66
    • /
    • 1998
  • Since a gas turbine is made use of generating electricity for peak time, it is a very important to operate a peak time load with safety. The main components of a gas turbine are the compressor, the combustion chamber and the turbine. So, there also must be modeled a component of gas turbines for the control with safety but it is not easy. In this paper we acquire a transfer function based on the operations data of Gun-san gas turbine and study to apply Neural-Network 2-DOF PID controler to control loop of gas turbine to reduce phenomena caused by integral and derivative actions through simulation. We obtained satisfactory results to disturbances of subcontrol loop such as, fuel flow, air flow, turbine extraction temperature.

  • PDF

IR 불꽃화재감지기 개발

  • 권오승;이복영;박상태
    • 방재기술
    • /
    • 통권29호
    • /
    • pp.39-45
    • /
    • 2000
  • All objects emit thermal radiation and this radiation is the basis of the techniques used to detect flames. The usual phenomena occurring in the initial stage of a fire are generally invisible products of a combustion and visible smoke. Liquid or gaseous materials do not undergo a smoldering stage such fires develop very rapidly. Also, the heat generated by the initial flames is usually not sufficient to active a heat detector. In this case the most effective criterion for automatic fire detection is the flame. In fire regulation of korea, the compulsory standard provided that a flame detector shall be installed a place of the attachment hight of detector is higher than 20 m, chemical plants, hangar, refinery, etc.. The result of the research and development are discriminated between a flame and other radiant emitters, developed PZT pyroelectric element is based on the use of photo-voltanic cell, developed IR band-pass filter that only allow a 4.3 radiation wavelength to reach the sensors and developed IR flame detector.

  • PDF

Numerical Analysis of Solid Propellant Ignition ~Numerical Formulation Assessment~

  • Shimada, Toru;Novozhilov, Boris V.
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2004년도 제22회 춘계학술대회논문집
    • /
    • pp.528-531
    • /
    • 2004
  • For a simple one-dimensional ignition problem a mathematical model is described to investigate the difficulties in numerical simulations. Some computation results are obtained and comparison is made with analytical solution. Discussions are made on topics such as 1) coordinate transformation, 2) gas-phase and solid-phase analysis; (divergence form of the governing system, a finite-volume discretization, implicit time integration, upwind split flux, spatial accuracy improvement are described. Mass, reagent mass, and energy conservations are solved.), and 3) method to determine quantities on the burning surface (matching). Results obtained for small values of the non-dimensional pressure show a steady-combustion and good agreement with the analytical solution. Numerical instability appeared for larger values of the pressure, discussion on the cause of the problem is made. This effort is a part of a study of flame spread phenomena on solid propellant surface.

  • PDF

화재 성장 모델이 객차내 화재 특성에 미치는 영향에 관한 수치해석적 연구 (A Numerical Study of the Effect off Fire Growth Model on Fire Characteristics in a Carriage)

  • 김성찬;유홍선;최영기;김동현
    • 한국철도학회논문집
    • /
    • 제7권3호
    • /
    • pp.180-185
    • /
    • 2004
  • The present study investigates the effect of fire growth model on fire development characteristics in a carriage. The parallel processing version of FDS code is used to simulate the fire driven flow in a carriage and two types of fire growth model which are flame spread model and t$^2$ model are examined for the same geometrical condition. The heat release rates(HRR) of both model are similar each other until 30 s after ignition, but the flame spread model predicts 5 times higher than those of the t$^2$ fire model during the quasi-steady fire period. Maximum heat release rate in the case of flame spread model reaches about to 12 MW at 100 s after fire ignition. Also, various database of fire properties for combustible materials and more elaborate combustion model considering the flame spreading phenomena are required for better predictions of fire development characteristics using numerical simulation.

격납용기내에서 분무형 나트륨화재 현상 해석 (Analysis of spray sodium fire phenomena in the containment vessel)

  • 조병렬;권선길;황성태
    • 한국안전학회지
    • /
    • 제11권2호
    • /
    • pp.79-88
    • /
    • 1996
  • A hypothetical accident in the containment vessel of liquid metal reactor could cause a pressure, temperature rise, and a strong aerosol release. The computer codes relating to the modelization of these accident make it necessary to use various input parameter, among which is the dynamic shape factor of aerosols produced. Combustion experiments of sodium spray fire carried out in a closed vessel, which was vertical cylinder made of 1.2m in diameter and 1.8m hight with a volume of 1.7$m^3$. The results of theoretical analysis presented here was compared to data obtained from experiments. The experimental results were summarized as follows. 1) The aerodynamic diameter and geometric diameter of aerosols are decreasing with increasing of injection pressure and injection temperature of sodium 2) The dynamic shape factor of aerosol is proportional to the aerodynamic diameter for a given particle. 3) The correspondence between the aerodynamic diameter and geometric diameter can be as $D_{ae}=0.70 D_{ge}$. 4) Peak pressure rose with increase in pressure and temperature of injection sodium, being more sensitive to the injection pressure than the injection temperature.

  • PDF

면적비 변화에 따른 튜브 내 고압 수소 자발점화현상 연구 (A study of area-ratio effect on self-ignition of high pressure hydrogen gas released in to a tube)

  • 윤희;이상윤;정만철;정인석;이형진
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2015년도 제51회 KOSCO SYMPOSIUM 초록집
    • /
    • pp.147-150
    • /
    • 2015
  • When high-pressure gas is suddenly leaked out into the air, unexpected ignition occurs without any external ignition source. Until now, there have been investigations on self-ignition of hydrogen by supplying high-pressure hydrogen gas into a tube. However the mechanism of hydrogen ignition is still unclear. This paper describes the area-ratio effect on hydrogen ignition by inserting a brass plate. The results show that the ignition phenomena differ as the area-ratio changed. Also, the rupture pressure for self-ignition has to be higher.

  • PDF