• 제목/요약/키워드: Combined wick

검색결과 3건 처리시간 0.016초

그루브수 증가에 따른 알루미늄 그루브 히트파이프의 성능향상에 관한 실험적 연구 (Experimental Study on the Performance Improvement of Aluminum Grooved Heat Pipe due to increased number of Grooves)

  • 홍진관;최상곤;김대성;정원복;변윤식;영권옥
    • 설비공학논문집
    • /
    • 제13권6호
    • /
    • pp.474-481
    • /
    • 2001
  • Aluminum/Freon22 grooved hat pipes which have 26 axial grooves in a cross-section were manufactured and tested. The performance test was conducted by varying filling ratio and tilt angle. Operation limit, thermal resistance, overall heat transfer coefficient were investigated. The experimental result was compared with previous study which conducted in the case of a heat pipe with combined wick. The experimental result shows that thermal resistance of this heat pipe is twice smaller than that of the heat pipe with combined wick and operation limit is increased about 75%, comparing with that of heat pipe with combined wick.

  • PDF

조합형 윅을 사용한 히트파이프의 작동특성에 관한 실험적 연구 (Experimental study on the working characteristic of a heat pipe with combined wick)

  • 홍진관;부준홍;정원복
    • 설비공학논문집
    • /
    • 제11권2호
    • /
    • pp.236-243
    • /
    • 1999
  • Aluminum/Freon-22 heat pipes were manufactured and tested which have a special wick geometry combining axial groove and screen mesh. There were 14 axial grooves in a cross-section and these were covered by two layers of 350 mesh screens to enhance the thermal performance. The performance test was conducted by varying the thermal load and tilt angle. Furthermore, the operation limits and overall heat transfer coefficient were investigated. The experimental results will be useful in a variety of applications, especially in design and manufacturing of a high-efficiency heat exchanger and energy recovery systems.

  • PDF

빗물 저류 시스템을 활용한 옥상 녹화의 온도 저감 효과 (The effect of Temperature Reduction of Green Roof using Rainwater Storage Tank)

  • 윤석환;김은섭;박정강;전윤호;강혜원;김상혁;김지연;강한민;함은경;이동근
    • 한국환경복원기술학회지
    • /
    • 제24권6호
    • /
    • pp.109-119
    • /
    • 2021
  • Thermal environment of city is getting worse due to severe urban heat island caused by climate change and urbanization. Green roof improves the urban thermal environment and save the cooling energy in buildings. This study presented a green roof combined with a storage system that stores rain-water and supplies water through a wick and evaluated the temperature reduction effect as surface temperature and amount of evapotranspiration. For about a week, the surface temperature using a infrared thermal imager and the evapotranspiration by recording change of module weight were measured at intervals of 30 minutes from sunrise to sunset. The results show that the mean surface temperature of the green roof was 15.4 degrees lower than that of the non-green roof from 12:00 P.M. to 14:00 P.M. There was no significant difference between mean surface temperature of green roof with and without storage system immediately after rain, but more than a week after rain, there was a difference with average of 2.49 degrees and maximum of 4.72 degrees. The difference in daily amount of evapotranspiration was measured to be 1.66 times on average. As drought stress increased over time, the difference in daily amount of evapotranspiration and surface temperature between with/without storage system increased simultaneously. The results of the study show a more excellent cooling effect of green roof combined with the rainwater storage system.