• Title/Summary/Keyword: Combined transmission lines

Search Result 43, Processing Time 0.024 seconds

Indirect adaptive nonlinear control for power system stabilization (전력계통안정화를 위한 간접적응 비선형제어)

  • 이도관;윤태웅;이병준
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1997.10a
    • /
    • pp.454-457
    • /
    • 1997
  • As in most industrial processes, the dynamic characteristics of an electric power system are subject to changes. Amongst those effects which cause the system to be uncertain, faults on transmission lines are considered. For the stabilization of the power system, we present an indirect adaptive control method, which is capable of tracking a sudden change in the effective reactance of a transmission line. As the plant dynamics are nonlinear, an input-output feedback linearization method equipped with nonlinear damping terms is combined with an identification algorithm which estimates the effect of a fault. The stability of the resulting adaptive nonlinear system is investigated.

  • PDF

Power system stabilization via adaptive feedback linearization (비선형 적응제어를 이용한 전력계통 안정화)

  • 윤태웅;이도관
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.1221-1224
    • /
    • 1996
  • As in most industrial processes, the dynamic characteristics of an electric power system are subject to changes. Amongst those effects which cause the system to be uncertain, faults on transmission lines are considered. For the stabilization of the power system, we present an indirect adaptive control method, which is capable of tracking a sudden change in the effective reactance of a transmission line. As the plant dynamics are nonlinear, an input-output feedback linearization method is combined with an identification algorithm which estimates the effect of a fault.

  • PDF

A Study on the Digital Distance Relaying Algorithm Using Wavelet Transform in Combined Transmission Line with Underground Power Gables (웨이브렛 변환을 이용한 혼합송전계통에서의 디지털 거리계전 알고리즘에 관한 연구)

  • Jung, Che-Kyun;Hong, Dong-Suk;Lee, Jong-Beom
    • Proceedings of the KIEE Conference
    • /
    • 2001.11b
    • /
    • pp.383-386
    • /
    • 2001
  • Distance relay is tripped by the line impedance calculated at the relay point. Accordingly the accurate operation depends on the precise calculation of line impedance. Impedance can be accurately calculated in case of overhead line. However, in case of power cables or combined transmission lines, impedance can not be accurately calculated because cable systems have the sheath, grounding wires, and cable cover protection units (CCPUs). There are also several grounding systems in cable systems. Therefore, if there is a fault in cable system, these terms will severely be caused much error to calculation of impedance. Accordingly the proper compensation should be developed for the correct operation of the distance relay. This paper presents the distance calculating algorithm in combined transmission line with power cable using wavelet transform. In order to achieve such purpose, judgement method to discriminate the fault section in both sections was proposed using db1 coefficient summation. And also, error compensation factor was proposed for correct calculation of impedance in power cable.

  • PDF

Crosstalk Analysis of Bent Coupled Lines on a PCB (PCB상에 놓여 있는 굽은 결합 선로의 누화 해석)

  • Han, Jae-Kwon;Park, Dong-Chul
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.18 no.2 s.117
    • /
    • pp.191-198
    • /
    • 2007
  • The electromagnetic coupling between transmission lines in PCB design can degrade the performance of equipment operations. The coupling phenomenon is caused by electromagnetic fields generated by the currents on the transmission lines and the risers. In this paper, an improved method of crosstalk analysis for bent coupled lines on a PCB is proposed and investigated. In the previous cascading method combined with circuit-concept approach, bent coupled lines are devided into sections and each section is represented by ABCD matrix and then they are cascaded. In the proposed method, the crosstalk of bent coupled lines is calculated by the modified circuit-concept approach, where the coupled region is not restricted to the region projected by a generator line on a receptor line but is the total length of receptor line in calculating the forcing terms. Finally, the accuracy of the proposed approach is verified by comparing the calculated results with the measured ones for several bent coupled-line examples.

A Study on the Economic Analysis of LNG Combined Cycle Thermal Power Plant in Cost Based Pool Electricity Markets (변동비반영 발전경쟁시장에서 LNG-복합 화력발전소의 경제성 분석에 관한 연구)

  • Lee, Cheon-Ho;Han, Seok-Man;Chung, Koo-Hyung;Kang, Dong-Ju;Kim, Bal-Ho H.
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.8
    • /
    • pp.1327-1333
    • /
    • 2008
  • Since Cost Based Pool markets has been continued to power markets, Genco. needs economic analysis about investment in power plants. Particularly most Private Genco.s have presently a construction plan about LNG combined cycle thermal power plants. In this paper, we propose a economic analysis method of LNG combined cycle thermal power plants using Economic Dispatch and Optimal Power Flow in CBP markets. Also we develope computation model using it for decision making to build a plant. This method can consider a variation of power facility like power plants and transmission lines in CBP markets. Finally, this dissertation provides a relevant case study to confirm the effect of cost factor to economical efficiency.

Ring Hybrid Coupler with Compact Size and Wide Bandwidth (넓은 대역폭을 가지는 소형 링 하이브리드)

  • Kim, Ui-Jung;Kim, Seung-Hwan;Kim, Ell-Kou;Lee, Young-Soon;Kim, Young;Yoon, Young-Chul
    • Journal of Advanced Navigation Technology
    • /
    • v.13 no.2
    • /
    • pp.194-200
    • /
    • 2009
  • This paper introduces a ring hybrid coupler using shunt capacitors, high impedance lines and CRLH-TLs (Composite Right/Left-Handed Transmission Lines) with size reduction and bandwidth enhancement. The reduced method of line length uses to combine a short length high impedance line and shunt capacitors. Also, there is combined CRLH meta-material so as to obtain wide bandwidth of transmission line using nonlinear phase characteristic of CRLH-TL that consists of series capacitors and shunt inductors. The implemented ring hybrid coupler shows a novel design with compact size that is smaller than 10% and bandwidth is larger than 60% of conventional ring hybrid coupler.

  • PDF

Optimal Design of Nonuniform Transmission Lime Sections for Wide-Band Impedance Matching (광대역 임피이던스정합용 불균일군차선로의 최적설계)

  • 박송배
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.11 no.6
    • /
    • pp.38-43
    • /
    • 1974
  • A design problem is studied for a nonuniform transmission line (NUTL) section to be inserted between an arbitrary source impedance and an arbitary load impedance for the purpose of impedance matching or providing a minimum input reflection coefficient over a frequency ranee as wide as possible. A special class of NUTL's, yet comprehensive enough to include almost all smoothly varying lines, are considered. Power series expansions of the ABCD parameters of such lines are used in the calculation of the input reflection coefficient. The design problem is formulated as a nonlinear programming problem withnonlinear constraints and is solved by a combined use of the sequential unconstrained minimization technique and tile Fletcher-Powell method. As a result, a line section was obtained which shows a marked improvement over any one hitherto published as a wide-band impedance matching device.

  • PDF

The Cause of CCPU's failure and Improved Configuration Method in Combined Transmission Lines (실 계통의 혼합송전선로에서 CCPU파괴 원인과 그 대책)

  • Ha, C.W.;Kim, J.N.;Lee, S.K.;Heo, H.D.
    • Proceedings of the KIEE Conference
    • /
    • 2001.11b
    • /
    • pp.210-212
    • /
    • 2001
  • The protection of underground cables against transient overvoltages resulting from lightning and other causes is important in cable-tine which is connected with overhead line and underground cable. This paper investigates the failure of CCPU(Cable covering Protection Unit) and presents improved configuration method of CCPU in underground cable system EMTP(Electromagnetic Transient Program) is used in order to study the overvoltages and modeling of components of the system such as overhead lines, underground cables, CCPUs and towers in presented.

  • PDF

A 90°-Bent Spur-Line Combined CRLH ZOR Bandpass Filter for the Channel of the UWB Communication System

  • Lee, Changhyeong;Kahng, Sungtek
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.2
    • /
    • pp.928-935
    • /
    • 2018
  • In this paper, a compact fully printable bandpass filter is suggested for a low-frequency channel 3.2 GHz ~ 3.7 GHz in the Ultra-Wideband (UWB) communication system. It is featured with a small geometry of $0.5{\lambda}_g/15$ and a low insertion loss despite using FR4 as a cheap substrate of a high dielectric loss. This is made possible by generating zeroth-order-resonance (ZOR) from one cell comprising two series resonances obviously separated from one shunt resonance as a third-order bandpass filter. Especially, the series resonance elements are combined with spur-lines bent by 90 degrees, which makes the port-impedance matched well and eliminates spurious hikes in the stopband, while the overall size remains almost unchanged. The design is carried out by setting up the equivalent circuit and the circuit simulation is checked by the full-wave EM analysis. The structure is manufactured and measured to show that the circuit modeling and EM simulation results agree with the measured data.

A Study on the Characteristics of Microwave Transmission Lines Having Defected Ground Structures and Lumped Elements (결함접지구조와 집중소자를 지닌 초고주파 전송선로의 전기적 특성 연구)

  • Lim Jong-Sik;Bae Ju-Seok;Choi Kwan-Sun;Ahn Dal
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.7 no.4
    • /
    • pp.616-624
    • /
    • 2006
  • In this paper, the transfer characteristics of high frequency transmission line having defected ground structure (DGS) and lumped elements are described. When a DGS, which is a kind of periodic structure, is inserted into a transmission line, its equivalent inductance and capacitance elements are added to the characteristics of the standard transmission line. This generates resonance, 3dB cut-off frequency, low-pass, band rejection, and band pass characteristics, and causes a slow-wave and enlarged electrical length of the transmission line. In addition, if the DGS is combined by a lumped element such as resistor, capacitor, and inductor, the resonant and cut-off frequencies moves up or down and other changes occur in the transmission characteristics. The variation of the transmission characteristics is described with the qualitative prediction and measured data.

  • PDF