• 제목/요약/키워드: Combined system

검색결과 5,700건 처리시간 0.057초

초단기 및 단기 다변수 시계열 결합모델을 이용한 24시간 부하예측 (24 hour Load Forecasting using Combined Very-short-term and Short-term Multi-Variable Time-Series Model)

  • 이원준;이문수;강병오;정재성
    • 전기학회논문지
    • /
    • 제66권3호
    • /
    • pp.493-499
    • /
    • 2017
  • This paper proposes a combined very-short-term and short-term multi-variate time-series model for 24 hour load forecasting. First, the best model for very-short-term and short-term load forecasting is selected by considering the least error value, and then they are combined by the optimal forecasting time. The actual load data of industry complex is used to show the effectiveness of the proposed model. As a result the load forecasting accuracy of the combined model has increased more than a single model for 24 hour load forecasting.

Analysis of Design and Part Load Performance of Micro Gas Turbine/Organic Rankine Cycle Combined Systems

  • Lee, Joon-Hee;Kim, Tong-Seop
    • Journal of Mechanical Science and Technology
    • /
    • 제20권9호
    • /
    • pp.1502-1513
    • /
    • 2006
  • This study analyzes the design and part load performance of a power generation system combining a micro gas turbine (MGT) and an organic Rankine cycle (ORC). Design performances of cycles adopting several different organic fluids are analyzed and compared with performance of the steam based cycle. All of the organic fluids recover greater MGT exhaust heat than the steam cycle (much lower stack temperature), but their bottoming cycle efficiencies are lower. R123 provides higher combined cycle efficiency than steam does. The efficiencies of the combined cycle with organic fluids are maximized when the turbine exhaust heat of the MGT is fully recovered at the MGT recuperator, whereas the efficiency of the combined cycle with steam shows an almost reverse trend. Since organic fluids have much higher density than steam, they allow more compact systems. The efficiency of the combined cycle, based on a MGT with 30 percent efficiency, can reach almost 40 percent. hlso, the part load operation of the combined system is analyzed. Two representative power control methods are considered and their performances are compared. The variable speed control of the MGT exhibits far better combined cycle part load efficiency than the fuel only control despite slightly lower bottoming cycle performance.

수학적 모델링 방법에 기초한 복합발전 공정의 정상상태 모사시스템 개발 (Process Modeling System of a Combined Cycle Plant for Steady State Simulation with Model Based Approach)

  • 김신혁;이시황;주용진;이상욱;손병모;오민
    • Korean Chemical Engineering Research
    • /
    • 제53권5호
    • /
    • pp.545-552
    • /
    • 2015
  • 복합발전 공정의 모델링 및 모사는 공정의 운전 및 설계 조건에 따른 공정변수의 변화를 정량적으로 예측하기 위한 중요한 접근방법이다. 본 연구에서는 현재 사용되는 복합발전공정의 정상상태 모사기의 단점을 보완하여, 사용자의 편의성과 개발자의 핵심기술 모델링을 가능하게 하는 공정 모델링 시스템을 개발하였다. 복합발전 공정의 주요 장치들을 분석하여 수학적 모델을 개발하였으며 이를 종합하여 모델라이브러리로 구성하였다. 또한 모사의 목적과 입수 가능한 자료에 따라 사용되는 모델의 상세도가 다르다는 점을 고려하여 주요장치에 대해 다른 상세도의 모델을 개발하였다. 복합발전 상업공정을 개발된 모델링 시스템을 사용하여 모델링과 모사를 수행하였으며 모사의 결과를 데이터자료와 비교 검증하였다. 검증의 모사결과와 자료데이터는 1% 내의 오차를 보였으며 개발된 모델링 시스템이 실제 공정에 응용될 수 있음을 보여주었다.

소형 가스엔진 열병합발전 시스템의 안전관리 방안에 관한 연구 (A Study on the Safety Management Methods of Micro-Gas Engine Combined Heat and Power System)

  • 김소현;김민우;이은경;이정운
    • 한국가스학회지
    • /
    • 제22권6호
    • /
    • pp.76-89
    • /
    • 2018
  • 지속적인 산업 발전에 따른 에너지 수급의 불안정 및 환경오염 문제가 대두됨에 따라 이에 대한 해결 방안의 일환으로 열병합발전 시스템의 보급이 활발해지고 있다. 국내의 경우 가스엔진을 이용한 열병합발전기의 안전성능에 대한 검사기준이 미비하므로 이에 대한 연구가 필요한 실정이다. 본 연구에서는 20 kW급 가스엔진 열병합발전 시스템에 적용 가능한 안전성능 관련 표준화 연구 수행을 위해 열병합발전 시스템의 국내 외 기준에 대한 안전성능 및 구조/재료 평가기준을 분석하였다. 또한, 위험요소 분석 및 HAZOP (Hazard and Operability Studies)을 이용한 위험성평가를 수행하여 가스엔진 열병합발전 시스템의 안전성능 평가(안)을 도출하였으며, 평가항목으로는 안전성능 관련 엔진 시동, 배관 기밀 성능, 살수 및 온도 상승 성능, 연소 성능, 전기 효율, 열효율, 종합 효율, 습도 성능 등이 포함된다. 가스엔진 열병합발전 시스템의 구조 및 재료와 관련하여 가스 및 수배관, 가스 조절 및 차단밸브, 금속 또는 비금속 재료의 내구성, 내열성, 내한성에 대한 평가항목을 도출하였다.

가스터빈-연료전지 혼합형 고효율 발전시스템 (High Efficiency Gas Turbine-Fuel Cell Hybrid Power Generation System)

  • 이진근;양수석;손정락;송락현;조형희
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2001년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.347-353
    • /
    • 2001
  • A combined cycle, 'HYBRID', is emerging as a new power generation technology that is particularly suitable for the distributed power generation system, with high energy efficiency and low pollutant emission. Currently micro gas turbines and fuel cells are attracting a lot of attention to meet the future needs in the distributed power generation market. This hybrid system may have every advantages of both systems because a gas turbine is synergistically combined with a fuel cell into a unique combined cycle. The hybrid system is believed to become a leading runner in the distributed power generation market. This paper introduces a current plan associated with the development of the hybrid system which consists of a micro gas turbine and a solid-oxide fuel cell(SOFC).

  • PDF

전달함수를 이용한 동흡진기 설계에 대한 연구(I) (The Study of DVA used to Transfer Function (I))

  • 최정현;임병덕
    • 대한기계학회논문집A
    • /
    • 제27권9호
    • /
    • pp.1457-1462
    • /
    • 2003
  • The problem of reducing the level of vibrations in structures arises in various branches of technology. For the calculation of systems equipped with DVAs, the frequencies of the protected system's free vibrations are determined first. In most practical problems system have to be considered continuous systems. It is important to obtain the detailed information about not the first frequency and the mode but anothers corresponding to it. So, this paper describes the method to obtain the accurate information about the combined discrete system. This information is obtained from the combined system's receptance. This paper shows the convenience when design the dynamic vibration absorber with the combined system's receptance.

혼합배전계통에서 뇌과전압 해석을 통한 중성선과 가공지선 혼용 운전의 타당성 평가 (Suitability Evaluation on Joint Operation of Neutral Wire and Overhead Grounding Wire through Lightning Surge Analysis in Combined Distribution System)

  • 정석산;이종범;김용갑;송일근;김병숙
    • 전기학회논문지
    • /
    • 제59권12호
    • /
    • pp.2135-2142
    • /
    • 2010
  • This paper studies the validity about a joint operation of neutral wire and overhead grounding wire in combined distribution systems. The overhead grounding wire and neutral wire are currently installed separately and grounded by common. However there is no any ineffectiveness or electrical problem in case of the proposed system, such system can be operated at real distribution system. Therefore this paper describes the suitability of a joint operation through lightning surge analysis on combined distribution systems. Lightning surge analysis is carried out by EMTP/ATPDraw to obtain the overvoltage of overhead line and underground cable in various conditions such as locations and current types of lightning stroke. Overvoltage gained by the analysis show that the insulation strength of the joint operation case is not stable compare with the current operation case.

일체형 곡물 건조/저장 시스템 개발을 위한 Straight Type Sweeping Auger의 이송 특성 분석에 관한 연구 (A Study on the Conveying Characteristic Analysis of Straight Type Sweeping Auger for Development of Combined Grain Drying and Storage System)

  • 최갑용
    • 한국산학기술학회논문지
    • /
    • 제10권3호
    • /
    • pp.521-528
    • /
    • 2009
  • 본 연구는 일체형 곡물 건조/저장 시스템에 채용되고 있는 Straight Type Sweeping Auger에 대한 성능과 적합성 검사를 실험을 통하여 검증하였다. 일체형 곡물 건조/저장 시스템의 핵심 기술은 선입선출을 가능토록 하는 Sweeping Auger의 설계기술에 있다. 바람직한 Sweeping Auger의 설계방향을 제시하기 위하여 Straight Type Sweeping Auger가 곡물 속에서 회전할 때 원주면에서 유동하는 곡물의 거동을 알아보기 위한 실험을 실시하고 결과 분석을 통하여 원인규명을 하였다.

복합열병합 시스템에 대한 열과 전기의 원가산정 (Cost Accounting of Heat and Electricity of a Combined Cycle Cogeneration System)

  • 김덕진;이근휘
    • 설비공학논문집
    • /
    • 제17권6호
    • /
    • pp.560-568
    • /
    • 2005
  • The cost accounting of electricity and heat produced from an energy system is important in evaluating the economical efficiency and deciding the reasonable sale price. The OECOPC method, suggested by the author, was applied to a 650 MW combined cycle cogeneration system having 4 operating modes, and each unit cost of electricity and heat products was calculated. In case that a fuel cost is ${\\}400/kg$ and there are no direct and indirect cost, they were calculated as follows; electricity cost of ${\\}23,700/GJ$ at gas-turbine mode, electricity cost of ${\\}15,890/GJ$ at combined cycle mode, electricity cost of ${\\}14,146/GJ$ and heat cost of ${\\}6,466/GJ$ at cogeneration mode, and electricity cost of ${\\}14,387/GJ$ and heat cost of ${\\}4,421/GJ$ at combined cycle cogeneration mode. Further, these unit costs are applied to account benefit on this system. Since the suggested OECOPC method can be applied to any energy system, it is expected to contribute to cost accounting of various energy systems.

벽체-감쇠 복합시스템을 갖는 건물의 지진취약도 분석 (Seismic Fragility Analysis of Buildings With Combined Shear Wall-Damper System)

  • 라지불 이슬람;수딥타 차크라보르티;공병진;김두기
    • 한국지진공학회논문집
    • /
    • 제27권2호
    • /
    • pp.91-99
    • /
    • 2023
  • Structural vibration induced by earthquake hazards is one of the most significant concerns in structure performance-based design. Structural hazards evoked from seismic events must be properly identified to make buildings resilient enough to withstand extreme earthquake loadings. To investigate the effects of combined earthquake-resistant systems, shear walls and five types of dampers are incorporated in nineteen structural models by altering their arrangements. All the building models were developed as per ACI 318-14 and ASCE 7-16. Seismic fragility curves were developed from the incremental dynamic analyses (IDA) performed by using seven sets of ground motions, and eventually, by following FEMA P695 provisions, the collapse margin ratio (CMR) was computed from the collapse curves. It is evident from the results that the seismic performance of the proposed combined shear wall-damper system is significantly better than the models equipped with shear walls only. The scrutinized dual seismic resisting system is expected to be applied practically to ensure a multi-level shield for tall structures in high seismic risk zones.